BDBowen Du

Bowen Du

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bowen Du has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Short-Term Impact of a Portable Air Cleaner on Cognitive Performance

    by M. Rafsan Nahian, Bowen Du, Alexander Y. Mendell, Zoe Hoskin, Reza Daneshazarian, Melisa Gumus, Athanasios Bourganos, Michael Mack, Jeffrey A. Siegel

    Portable air cleaners (PACs) are commonly used to remove airborne particulate matter (PM) from indoor environments. This study evaluated the impact of a PAC on cognitive performance among 62 participants in an office environment by using a computer-based cognitive test battery of six tasks. Participants were exposed to PM from an essential oil diffuser with unscented oil and tap water during both air cleaner and placebo conditions in a balanced design. PM concentrations were 2.4 to 4 times lower when using the PAC compared to the placebo condition. Despite the significant reduction in PM levels, no significant improvement in cognitive scores was observed during PAC operation. However, using a mixed-effects model with outliers removed, a significant improvement in the feature match task was observed. When the PAC achieved a higher reduction in PM2.5 concentration, cognitive scores improved for three out of six tasks when compared to a smaller reduction in PM2.5, although the effect was not statistically significant. There was also no ordering effect between initial and subsequent placements of participants in either condition. Overall, these results indicate that although PACs effectively reduce PM, their impact on cognitive performance remains uncertain and may vary with PM source type, concentration, exposure duration, task demands, and other contextual factors.

  • Open Access

    Indoor air quality in swiss primary schools: impacts of mechanical ventilation and seasonal variation

    by Bowen Du, Joan F. Rey, Matias Cesari, Claude-Alain Roulet, Philippe Favreau, Vincent Perret, Guillaume Suarez, Corinne Hager Jörin, Joëlle Goyette Pernot, Dusan Licina


  • Estimating Air Change Rate in Mechanically Ventilated Classrooms Using a Single CO2 Sensor and Automated Data Segmentation

    by Bowen Du, Ibrahim Reda, Dusan Licina, Costa Kapsis, Dahai Qi, José A. Candanedo, Tianyuan Li

    With a growing emphasis on indoor air quality (IAQ) in educational environments, CO2 monitoring in classrooms has become commonplace. CO2 data can be used to estimate outdoor air change rate (ACH) based on the mass balance principle, which can be further linked to human health, performance, and building energy consumption. This study used a novel machine learning method to automatically segment CO2 concentration time series data into build-up, equilibrium, and decay periods, and then estimated classroom ACH using the corresponding CO2 mass balance equations. This method, applied to 40 classrooms in two mechanically ventilated K-6 schools, generated up to ten ACH estimates per day per classroom. A comparison with ACH calculated using the mechanical ventilation rates with 100% outdoor air reported by the building automation system during the study period reveals a slight underestimation by the decay and build-up methods, while the equilibrium method produced closer estimates. These differences may be attributed to uncertainties in occupancy, activity, CO2 emission rates, and air mixing. This research underscores the potential of leveraging CO2 data for more comprehensive IAQ assessments and highlights the challenges associated with accurately estimating ACH in real-world settings.


  • Prediction of mould growth rate within building envelopes: development and validation of an improved model

    by Lingjie Zeng, Yuqing Chen, Mingyao Ma, Bowen Du, Jun Gao, Guoqing Cao, Jingguang Li

    Mould growth is a common problem in building envelopes. This issue is usually caused by poor design and construction of walls and results from the difference between indoor and outdoor climatic conditions. Mould spores produced by mouldy walls may diffuse into the air, thereby affecting indoor air quality and threatening occupant health. Therefore, it is important to predict the risk of mould growth in building envelopes under various conditions. This study selected three buildings from a traditional community in Shanghai, China. First, the mould species in these building envelopes were identified. Based on the identification results, the growth rate of the corresponding genera was extracted from the literature to establish an isoline model that describes mould growth on the agar surface. In addition, the mould growth rate between and outside the isoline areas was predicted by modifying the Sautour model to relevant air temperature and humidity conditions. According to the results of the proposed model, the critical temperature and humidity that allow the growth of representative moulds from the buildings selected for this study can be expressed as φ =0.002633·cosh[0.10083·( θ -30)]+0.7153. The accuracy of the above model was verified experimentally, and the maximum relative error of the growth rate was within 25%.


  • The impact of emissions from an essential oil diffuser on cognitive performance

    by Bowen Du, Heather Schwartz‐Narbonne, Marlie Tandoc, Emily M. Heffernan, Michael L. Mack, Jeffrey A. Siegel

    Essential oil products are increasingly used in indoor environments and have been found to negatively contribute to indoor air quality. Moreover, the chemicals and fragrances emitted by those products may affect the central nervous system and cognitive function. This study uses a double-blind between-subject design to investigate the cognitive impact of exposure to the emissions from essential oil used in an ultrasonic diffuser. In a simulated office environment where other environmental parameters were maintained constant, 34 female and 25 male university students were randomly allocated into four essential oil exposure scenarios. The first two scenarios contrast lemon oil to pure deionized water, while the latter two focus on different levels of particulate matter differentiated by HEPA filters with non-scented grapeseed oil as the source. Cognitive function was assessed using a computer-based battery consisting of five objective tests that involve reasoning, response inhabitation, memory, risk-taking, and decision-making. Results show that exposure to essential oil emissions caused shortened reaction time at the cost of significantly worse response inhabitation control and memory sensitivity, indicating potentially more impulsive decision-making. The cognitive responses caused by scented lemon oil and non-scented grapeseed oil were similar, as was the perception of odor pleasantness and intensity.


  • Volatile organic compound and particulate matter emissions from an ultrasonic essential oil diffuser

    by Heather Schwartz‐Narbonne, Bowen Du, Jeffrey A. Siegel

    Ultrasonic essential oil diffusers (EODs) are a popular type of indoor scenting source. We performed a chamber study in which we measured the emissions from EODs used with lemon, lavender, eucalyptus, and grapeseed oils. Over the course of 15 min, the most abundant VOCs released from lemon, lavender, eucalyptus, and grapeseed oils were 2.6 ± 0.7 mg of d‐limonene, 3.5 ± 0.4 mg of eucalyptol, 1.0 ± 0.1 mg of linalyl acetate, and 0.2 ± 0.02 mg of linalyl acetate, respectively. Each oil had a unique particulate matter (PM) emission profile in terms of size, number density, and rate. The dominant size ranges of the PM were 10–100 nm for lemon oil, 50–100 nm for lavender oil, 10–50 nm for lemon oil, and above 200 nm for grapeseed oil. PM1 emission rates of approximately 2 mg/h, 0.1 mg/h, and 3 mg/h, were observed for lemon, lavender/eucalyptus, and grapeseed oils, respectively. A fivefold increase in PM1 emission was measured when the EOD with eucalyptus oil was filled with tap water as opposed to deionized water. Modeling suggests that reasonable use cases of EODs can contribute substantially to primary and secondary PM in indoor environments, but this potential varies depending on the oil and water types used.


  • Indoor CO 2 concentrations and cognitive function: A critical review

    by Bowen Du, Marlie C. Tandoc, Michael L. Mack, Jeffrey A. Siegel

    Poor indoor air quality indicated by elevated indoor CO2 concentrations has been linked with impaired cognitive function, yet current findings of the cognitive impact of CO2 are inconsistent. This review summarizes the results from 37 experimental studies that conducted objective cognitive tests with manipulated CO2 concentrations, either through adding pure CO2 or adjusting ventilation rates (the latter also affects other indoor pollutants). Studies with varied designs suggested that both approaches can affect multiple cognitive functions. In a subset of studies that meet objective criteria for strength and consistency, pure CO2 at a concentration common in indoor environments was only found to affect high‐level decision‐making measured by the Strategic Management Simulation battery in non‐specialized populations, while lower ventilation and accumulation of indoor pollutants, including CO2, could reduce the speed of various functions but leave accuracy unaffected. Major confounding factors include variations in cognitive assessment methods, study designs, individual and populational differences in subjects, and uncertainties in exposure doses. Accordingly, future research is suggested to adopt direct air delivery for precise control of CO2 inhalation, include brain imaging techniques to better understand the underlying mechanisms that link CO2 and cognitive function, and explore the potential interaction between CO2 and other environmental stimuli.