Muhammad Afzal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Muhammad Afzal has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ghulam Destgeer
Control and Manipulation of Microscale Living Objects, Center for Translational Cancer Research (TranslaTUM), Munich Institute of Biomedical Engineering (MIBE), Munich Institute of Integrated Materials, Energy and Process Engineering (MEP), Department of Electrical Engineering, School of Computation, Information and Technology (CIT), Technical University of Munich (TUM), Einsteinstraße 25, Munich 81675, Germany
5 shared publications - Hyung Jin Sung
Korea Advanced Institute of Science and Technology
5 shared publications Husnain Ahmed
Department of Mechanical Engineering, KAIST, Daejeon 34141, Korea
4 shared publicationsJinsoo Park
Department of Mechanical Engineering, KAIST, Daejeon 34141, Korea
3 shared publications- Jinsoo Park
Chonnam National University
2 shared publications Ali Hashmi
Institut de Biologie du Développement de Marseille (IBDM), France
1 shared publication
Latest Publications
- 30 September 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (21) , 3922-3929
Acoustofluidic generation of droplets with tunable chemical concentrations
An acoustofluidic device to generate droplets with tunable chemical concentrations.
- 30 September 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (21) , 3922-3929
Acoustofluidic generation of droplets with tunable chemical concentrations
An acoustofluidic device to generate droplets with tunable chemical concentrations.
- Open Access
- 11 March 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (14) , 7916-7921
Microparticle self-assembly induced by travelling surface acoustic waves
We present an acoustofluidic method based on travelling surface acoustic waves (TSAWs) for the self-assembly of microparticles inside a microfluidic channel.
- 11 March 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (14) , 7916-7921
Open AccessMicroparticle self-assembly induced by travelling surface acoustic waves
We present an acoustofluidic method based on travelling surface acoustic waves (TSAWs) for the self-assembly of microparticles inside a microfluidic channel.
- 28 January 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 114 (4) , 043702
Surface acoustic wave-based micromixing enhancement using a single interdigital transducer
The realization of efficient mixing of samples inside a microfluidic channel is essential for performing numerous biological assays in miniaturized total analysis systems. The low Reynolds number flows at the microscale create laminar streams inside the microchannel, limiting flow mixing to a molecular diffusion level. In this paper, we propose a simple and efficient acoustofluidic mixing technique inside a single-layered polydimethylsiloxane (PDMS) microfluidic channel. The proposed surface acoustic wave (SAW)-based system composed of a straight interdigitated transducer (IDT) is positioned beneath the PDMS microchannel. Fluorescein dye dissolved in deionized water (sample fluid) and deionized water (sheath fluid) was introduced through the first and second inlets of the PDMS microchannel, respectively. Their flow rates were controlled such that the sample fluid with fluorescein dye was hydrodynamically focused close to the bottom of the microchannel by the sheath fluid. High-frequency (140 MHz) SAWs, generated from the IDT placed right beneath the first outlet, mixed the two fluids under the influence of strong acoustic streaming flows. The mixed samples were then collected at the two outlet ports for further analysis of the mixing efficiency. The developed acoustofluidic mixing device required an input voltage of 12 Vpp at a total flow rate of 50 μl/min to realize complete mixing. At a similar applied voltage, the throughput of the proposed device could be further increased to 200 μl/min with a mixing efficiency of >90%.
- 28 January 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 114 (4) , 043702
Surface acoustic wave-based micromixing enhancement using a single interdigital transducer
The realization of efficient mixing of samples inside a microfluidic channel is essential for performing numerous biological assays in miniaturized total analysis systems. The low Reynolds number flows at the microscale create laminar streams inside the microchannel, limiting flow mixing to a molecular diffusion level. In this paper, we propose a simple and efficient acoustofluidic mixing technique inside a single-layered polydimethylsiloxane (PDMS) microfluidic channel. The proposed surface acoustic wave (SAW)-based system composed of a straight interdigitated transducer (IDT) is positioned beneath the PDMS microchannel. Fluorescein dye dissolved in deionized water (sample fluid) and deionized water (sheath fluid) was introduced through the first and second inlets of the PDMS microchannel, respectively. Their flow rates were controlled such that the sample fluid with fluorescein dye was hydrodynamically focused close to the bottom of the microchannel by the sheath fluid. High-frequency (140 MHz) SAWs, generated from the IDT placed right beneath the first outlet, mixed the two fluids under the influence of strong acoustic streaming flows. The mixed samples were then collected at the two outlet ports for further analysis of the mixing efficiency. The developed acoustofluidic mixing device required an input voltage of 12 Vpp at a total flow rate of 50 μl/min to realize complete mixing. At a similar applied voltage, the throughput of the proposed device could be further increased to 200 μl/min with a mixing efficiency of >90%.
- 18 June 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (14) , 8546-8552
Sheathless Focusing and Separation of Microparticles Using Tilted-Angle Traveling Surface Acoustic Waves
The sheathless focusing and separation of microparticles is an important pre-processing step in various biochemical assays in which enriched sample isolation is critical. Most previous microfluidic particle separation techniques have used a sheath flow to achieve efficient sample focusing. The sheath flow diluted the analyte, and required additional microchannels and accurate flow control. We demonstrated a tilted angle travelling surface acoustic wave (taTSAW)-based sheathless focusing and separation of particles in a continuous flow. The proposed device consisted of a piezoelectric substrate with a pair of interdigitated transducers (IDTs) deposited at two different angles relative to the flow direction. A Y-shaped polydimethylsiloxane (PDMS) microchannel having one inlet and two outlet ports was positioned on top of the IDTs such that the acoustic energy coupling into the fluid was maximized and wave attenuation by the PDMS walls was minimized. The two IDTs independently produced high-frequency taTSAWs, which propagated at ±30° with respect to the flow direction and imparted a direct acoustic radiation force onto the target particles. A sample mixture containing 4.8 and 3.2 µm particles was focused and then separated by the actuation of the IDTs at 194 and 136 MHz frequencies, respectively, without using an additional sheath flow. The proposed taTSAW-based particle separation device offered a high purity > 99% at the both outlets over a wide range of flow speeds (up to 83.3 mm/s).
- 18 June 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (14) , 8546-8552
Sheathless Focusing and Separation of Microparticles Using Tilted-Angle Traveling Surface Acoustic Waves
The sheathless focusing and separation of microparticles is an important pre-processing step in various biochemical assays in which enriched sample isolation is critical. Most previous microfluidic particle separation techniques have used a sheath flow to achieve efficient sample focusing. The sheath flow diluted the analyte, and required additional microchannels and accurate flow control. We demonstrated a tilted angle travelling surface acoustic wave (taTSAW)-based sheathless focusing and separation of particles in a continuous flow. The proposed device consisted of a piezoelectric substrate with a pair of interdigitated transducers (IDTs) deposited at two different angles relative to the flow direction. A Y-shaped polydimethylsiloxane (PDMS) microchannel having one inlet and two outlet ports was positioned on top of the IDTs such that the acoustic energy coupling into the fluid was maximized and wave attenuation by the PDMS walls was minimized. The two IDTs independently produced high-frequency taTSAWs, which propagated at ±30° with respect to the flow direction and imparted a direct acoustic radiation force onto the target particles. A sample mixture containing 4.8 and 3.2 µm particles was focused and then separated by the actuation of the IDTs at 194 and 136 MHz frequencies, respectively, without using an additional sheath flow. The proposed taTSAW-based particle separation device offered a high purity > 99% at the both outlets over a wide range of flow speeds (up to 83.3 mm/s).
- 30 November 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (24) , 13313-13319
Acoustic Wave-Driven Functionalized Particles for Aptamer-Based Target Biomolecule Separation
We developed a hybrid microfluidic device that utilized acoustic waves to drive functionalized microparticles inside a continuous flow microchannel and to separate particle-conjugated target proteins from a complex fluid. The acoustofluidic device is composed of an interdigitated transducer that produces high-frequency surface acoustic waves (SAW) and a polydimethylsiloxane (PDMS) microfluidic channel. The SAW interacted with the sample fluid inside the microchannel and deflected particles from their original streamlines to achieve separation. Streptavidin-functionalized polystyrene (PS) microparticles were used to capture aptamer (single-stranded DNA) labeled at one end with a biotin molecule. The free end of the customized aptamer15 (apt15), which was attached to the microparticles via streptavidin–biotin linkage to form the PS–apt15 conjugate, was used to capture the model target protein, thrombin (th), by binding at exosite I to form the PS–apt15–th complex. We demonstrated that the PS–apt15 conjugate selectively captured thrombin molecules in a complex fluid. After the PS–apt15–th complex was formed, the sample fluid was pumped through a PDMS microchannel along with two buffer sheath flows that hydrodynamically focused the sample flow prior to SAW exposure for PS–apt15–th separation from the non-target proteins. We successfully separated thrombin from mCardinal2 and human serum using the proposed acoustofluidic device.
- 30 November 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (24) , 13313-13319
Acoustic Wave-Driven Functionalized Particles for Aptamer-Based Target Biomolecule Separation
We developed a hybrid microfluidic device that utilized acoustic waves to drive functionalized microparticles inside a continuous flow microchannel and to separate particle-conjugated target proteins from a complex fluid. The acoustofluidic device is composed of an interdigitated transducer that produces high-frequency surface acoustic waves (SAW) and a polydimethylsiloxane (PDMS) microfluidic channel. The SAW interacted with the sample fluid inside the microchannel and deflected particles from their original streamlines to achieve separation. Streptavidin-functionalized polystyrene (PS) microparticles were used to capture aptamer (single-stranded DNA) labeled at one end with a biotin molecule. The free end of the customized aptamer15 (apt15), which was attached to the microparticles via streptavidin–biotin linkage to form the PS–apt15 conjugate, was used to capture the model target protein, thrombin (th), by binding at exosite I to form the PS–apt15–th complex. We demonstrated that the PS–apt15 conjugate selectively captured thrombin molecules in a complex fluid. After the PS–apt15–th complex was formed, the sample fluid was pumped through a PDMS microchannel along with two buffer sheath flows that hydrodynamically focused the sample flow prior to SAW exposure for PS–apt15–th separation from the non-target proteins. We successfully separated thrombin from mCardinal2 and human serum using the proposed acoustofluidic device.