SRSerge Riffard

Serge Riffard

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Serge Riffard has a total of 102 co-authors. Here are the top co-authors by number of shared publications:

  • Françoise Girardot

    Université de Lyon, Université Jean Monnet, CNRS, EVS-ISTHME UMR 5600, F-42023 Saint-Etienne, France

    6 shared publications
  • Bruno Pozzetto

    CHU de Saint-Etienne, Département des agents infectieux et d'hygiène, Saint-Etienne, France; Centre International de Recherche en Infectiologie (CIRI), Equipe GIMAP, Inserm U1111, CNRS UMR5308, ENS de Lyon, Université Claude Bernard - Lyon 1, Université Jean Monnet de Saint-Etienne, Saint-Etienne, France

    4 shared publications
  • Florence Grattard

    A GIMAP EA 3064 (Groupe Immunité des Muqueuses et Agents Pathogènes) , University of Lyon , Saint-Etienne , France

    4 shared publications
  • Jerome Etienne

    4 shared publications
  • Séverine Allegra

    Université de Lyon, Université Jean Monnet, CNRS, EVS-ISTHME UMR 5600, F-42023 Saint-Etienne, France

    4 shared publications
  • Thibaut Epalle

    Groupe Immunité des Muqueuses et Agents Pathogènes (GIMAP) EA 3064, SFR 143, University of Lyon, 42023, Saint-Etienne, France

    4 shared publications

Latest Publications

  • Deposition pattern of aerosolized Legionella using an ex vivo human-porcine respiratory model

    by Sophie Perinel, Valérie Forest, Mathilde Landraud, Jérémie Pourchez, Françoise Girardot, Serge Riffard, Magalie Stauffert, Jean-Michel Vergnon, Séverine Allegra


  • Open Access

    Experimental human-like model to assess the part of viable Legionella reaching the thoracic region after nebulization

    by Jérémie Pourchez, Lara Leclerc, Françoise Girardot, Serge Riffard, Nathalie Prevot, Séverine Allegra

    The incidence of Legionnaires’ disease (LD) in European countries and the USA has been constantly increasing since 1998. Infection of humans occurs through aerosol inhalation. To bridge the existing gap between the concentration of Legionella in a water network and the deposition of bacteria within the thoracic region (assessment of the number of viable Legionella), we validated a model mimicking realistic exposure through the use of (i) recent technology for aerosol generation and (ii) a 3D replicate of the human upper respiratory tract. The model’s sensitivity was determined by monitoring the deposition of (i) aerosolized water and Tc99m radio-aerosol as controls, and (ii) bioaerosols generated from both Escherichia coli and Legionella pneumophila sg 1 suspensions. The numbers of viable Legionella prior to and after nebulization were provided by culture, flow cytometry and qPCR. This study was designed to obtain more realistic data on aerosol inhalation (vs. animal experimentation) and deposition at the thoracic region in the context of LD. Upon nebulization, 40% and 48% of the initial Legionella inoculum was made of cultivable and non-cultivable cells, respectively; 0.7% of both populations reached the filter holder mimicking the thoracic region in this setup. These results are in agreement with experimental data based on quantitative microbial risk assessment methods and bring new methods that may be useful for preventing LD.


  • Open Access

    Characterization of aerosols containing Legionella generated upon nebulization

    by Séverine Allegra, Lara Leclerc, Pierre André Massard, Françoise Girardot, Serge Riffard, Jérémie Pourchez

    Legionella pneumophila is, by far, the species most frequently associated with Legionnaires’ disease (LD). Human infection occurs almost exclusively by aerosol inhalation which places the bacteria in juxtaposition with alveolar macrophages. LD risk management is based on controlling water quality by applying standardized procedures. However, to gain a better understanding of the real risk of exposure, there is a need (i) to investigate under which conditions Legionella may be aerosolized and (ii) to quantify bacterial deposition into the respiratory tract upon nebulization. In this study, we used an original experimental set-up that enables the generation of aerosol particles containing L. pneumophila under various conditions. Using flow cytometry in combination with qPCR and culture, we determined (i) the size of the aerosols and (ii) the concentration of viable Legionella forms that may reach the thoracic region. We determined that the 0.26–2.5 μm aerosol size range represents 7% of initial bacterial suspension. Among the viable forms, 0.7% of initial viable bacterial suspension may reach the pulmonary alveoli. In conclusion, these deposition profiles can be used to standardize the size of inoculum injected in any type of respiratory tract model to obtain new insights into the dose response for LD.


  • Monitoring of Legionella pneumophila viability after chlorine dioxide treatment using flow cytometry

    by Pascale Mustapha, Thibaut Epalle, Séverine Allegra, Françoise Girardot, Olivier Garraud, Serge Riffard


  • Characterisation of electrochemical immunosensor for detection of viable not-culturable forms of Legionellla pneumophila in water samples

    by Dejla Sboui, Mina Souiri, Stephanie Reynaud, Sabine Palle, Manel Ben Ismail, Thibaut Epalle, Ridha Mzoughi, Françoise Girardot, Séverine Allegra, Serge Riffard, et al.

    Legionella pneumophila may cause a fatal pneumonia in humans known as Legionnaires’ disease (LD). The strategies of L. pneumophila to adapt to and resist stressful environmental conditions include the ability to enter into a VBNC (viable but not culturable) state. The detection of L. pneumophila in environmental samples benefits from the use of standardised methods: for detection and enumeration following membrane filtration (AFNOR T90-431, ISO 11731) and detection and quantification by polymerase chain reaction PCR (AFNOR T90-471, ISO 12869). Culture is hampered by its inability to detect VBNC forms and PCR is unable to discriminate between live and dead bacteria. The present immunosensor was obtained by the immobilisation of a monoclonal anti-L. pneumophila antibody (MAb) on an indium-tin oxide (ITO) electrode by the self-assembled monolayers (SAMs) method using an aminosilane. The immunosensor was characterised by wettability (contact angle measurement), atomic force microscopy (AFM), confocal laser scanning microscopy (CLSM), and electrochemical impedance spectroscopy (EIS). A limit of detection of 10 bacteria per mL was observed on artificial samples.


  • Viable but Not Culturable Forms of Legionella pneumophila Generated After Heat Shock Treatment Are Infectious for Macrophage-Like and Alveolar Epithelial Cells After Resuscitation on Acanthamoeba polyphaga

    by Thibaut Epalle, Françoise Girardot, Séverine Allegra, Cécile Maurice-Blanc, Olivier Garraud, Serge Riffard

    Legionella pneumophila, the causative agent of legionellosis is transmitted to human through aerosols from environmental sources and invades lung’s macrophages. It also can invade and replicate within various protozoan species in environmental reservoirs. Following exposures to various stresses, L. pneumophila enters a non-replicative viable but non-culturable (VBNC) state. Here, we evaluated whether VBNC forms of three L. pneumophila serogroup 1 strains (Philadelphia GFP 008, clinical 044 and environmental RNN) infect differentiated macrophage-like cell lines (U937 and HL-60), A549 alveolar cells and Acanthamoeba polyphaga. VBNC forms obtained following shocks at temperatures ranging from 50 to 70 °C for 5 to 60 min were quantified using a flow cytometric assay (FCA). Their loss of culturability was checked on BCYE agar medium. VBNC forms were systematically detected upon a 70 °C heat shock for 30 min. When testing their potential to resuscitate upon amoebal infection, VBNC forms obtained after 30 min at 70 °C were re-cultivated except for the clinical strain. No resuscitation or cell lysis was evidenced when using U937, HL-60, or A549 cells despite the use of various contact times and culture media. None of the strains tested could infect A. polyphaga, macrophage-like or alveolar epithelial cells after a 60-min treatment at 70 °C. However, heat-treated VBNC forms were able to infect macrophage-like or alveolar epithelial cells following their resuscitation on A. polyphaga. These results suggest that heat-generated VBNC forms of L. pneumophila (i) are not infectious for macrophage-like or alveolar epithelial cells in vitro although resuscitation is still possible using amoeba, and (ii) may become infectious for human cell lines following a previous interaction with A. polyphaga.


  • AFM, CLSM and EIS characterization of the immobilization of antibodies on indium–tin oxide electrode and their capture of Legionella pneumophila

    by Mina Souiri, Nesrine Blel, Dejla Sboui, Lotfi Mhamdi, Thibaut Epalle, Ridha Mzoughi, Serge Riffard, Ali Othmane


  • Longitudinal Evaluation of the Efficacy of Heat Treatment Procedures against Legionella spp. in Hospital Water Systems by Using a Flow Cytometric Assay

    by Severine Allegra, Florence Grattard, Françoise Girardot, Serge Riffard, Bruno Pozzetto, Philippe Berthelot

    Legionella spp. are frequently isolated in hospital water systems. Heat shock (30 min at 70°C) is recommended by the World Health Organization to control its multiplication. The aim of the study was to evaluate retrospectively the efficacy of heat treatments by using a flow cytometry assay (FCA) able to identify viable but nonculturable (VBNC) cells. The study included Legionella strains (L. pneumophila [3 clusters] and L. anisa [1 cluster]) isolated from four hot water circuits of different hospital buildings in Saint-Etienne, France, during a 20-year prospective surveillance. The strains recovered from the different circuits were not epidemiologically related, but the strains isolated within a same circuit over time exhibited an identical genotypic profile. After an in vitro treatment of 30 min at 70°C, the mean percentage of viable cells and VBNC cells varied from 4.6% to 71.7%. The in vitro differences in heat sensitivity were in agreement with the observed efficacy of preventive and corrective heating measures used to control water contamination. These results suggest that Legionella strains can become heat resistant after heating treatments for a long time and that flow cytometry could be helpful to check the efficacy of heat treatments on Legionella spp. and to optimize the decontamination processes applied to water systems for the control of Legionella proliferation.


  • Open Access

    Evaluation of an immunomagnetic separation assay in combination with cultivation to improveLegionella pneumophilaserogroup 1 recovery from environmental samples

    by S. Allegra, F. Girardot, F. Grattard, P. Berthelot, J.H. Helbig, B. Pozzetto, S. Riffard

    Aims: Legionella isolation from environmental samples is often difficult because of the presence of heterotrophic‐associated bacteria that frequently overgrow when using standard culture (ISO 11731, 1998; NF T90‐431, 2003) methods. To improve Legionella pneumophila recovery from complex water samples (water from cooling towers, biofilms), we evaluated an immunomagnetic separation (IMS) assay using a monoclonal antibody raised against the lipopolysaccharide of Leg. pneumophila sg1 in combination with culture. Methods and Results: This study was conducted on 51 environmental specimens. The comparison between IMS‐culture and standard culture (ISO 11731, 1998; NF T90‐431, 2003) methods was made using ISO 17994, 2004 criteria for establishing equivalence between microbiological methods based on the upper and lower (XH and XL) values of the relative difference (95% confidence limit) and D as maximum acceptable deviation (value of the confidence limit). Conclusions: We found that the average performance of IMS culture was higher than the reference method. Significance and Impact of the Study: Thus, this IMS‐culture assay is particularly well adapted to the detection of Leg. pneumophila sg1 in environmental samples with high levels of interfering microflora.