JGJoan Glaunès

Joan Glaunès

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joan Glaunès has a total of 111 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    How to Register a Live onto a Liver ? Partial Matching in the Space of Varifolds

    by Pierre-Louis Antonsanti, Thomas Benseghir, Vincent Jugnon, Mario Ghosn, Perrine Chassat, Joan Glaunès, Irène Kaltenmark

    Partial shapes correspondences is a problem that often occurs in computer vision (occlusion, evolution in time...). In medical imaging, data may come from different modalities and be acquired under different conditions which leads to variations in shapes and topologies. In this paper we use an asymmetric data dissimilarity term applicable to various geometric shapes like sets of curves or surfaces, assessing the embedding of a shape into another one without relying on correspondences. It is designed as a data attachment for the Large Deformation Diffeomorphic Metric Mapping (LDDMM) framework, allowing to compute a meaningful deformation of one shape onto a subset of the other. We refine it in order to control the resulting non-rigid deformations and provide consistent deformations of the shapes along with their ambient space. We show that partial matching can be used for robust multi-modal liver registration between a Computed Tomography (CT) volume and a Cone Beam Computed Tomography (CBCT) volume. The 3D imaging of the patient CBCT at point of care that we call __live__ is truncated while the CT pre-intervention provides a full visualization of the __liver__. The proposed method allows the truncated surfaces from CBCT to be aligned non-rigidly, yet realistically, with surfaces from CT with an average distance of $2.6mm(+/- 2.2)$. The generated deformations extend consistently to the liver volume, and are evaluated on points of interest for the physicians, with an average distance of $5.8mm (+/- 2.7)$ for vessels bifurcations and $5.13mm (+/- 2.5)$ for tumors landmarks. Such multi-modality volumes registrations would help the physicians in the perspective of navigating their tools in the patient's anatomy to locate structures that are hardly visible in the CBCT used during their procedures.Our code is available at https://github.com/plantonsanti/PartialMatchingVarifolds.


  • Open Access

    How to Register a Live onto a Liver ? Partial Matching in the Space of Varifolds

    by Pierre-Louis Antonsanti, Thomas Benseghir, Vincent Jugnon, Mario Ghosn, Perrine Chassat, Irène Kaltenmark, Joan Glaunès

    Partial shapes correspondences is a problem that often occurs in computer vision (occlusion, evolution in time...). In medical imaging, data may come from different modalities and be acquired under different conditions which leads to variations in shapes and topologies. In this paper we use an asymmetric data dissimilarity term applicable to various geometric shapes like sets of curves or surfaces, assessing the embedding of a shape into another one without relying on correspondences. It is designed as a data attachment for the Large Deformation Diffeomorphic Metric Mapping (LDDMM) framework, allowing to compute a meaningful deformation of one shape onto a subset of the other. We refine it in order to control the resulting non-rigid deformations and provide consistent deformations of the shapes along with their ambient space. We show that partial matching can be used for robust multi-modal liver registration between a Computed Tomography (CT) volume and a Cone Beam Computed Tomography (CBCT) volume. The 3D imaging of the patient CBCT at point of care that we call live is truncated while the CT pre-intervention provides a full visualization of the liver. The proposed method allows the truncated surfaces from CBCT to be aligned non-rigidly, yet realistically, with surfaces from CT with an average distance of 2.6mm(+/- 2.2). The generated deformations extend consistently to the liver volume, and are evaluated on points of interest for the physicians, with an average distance of 5.8mm (+/- 2.7) for vessels bifurcations and 5.13mm (+/- 2.5) for tumors landmarks. Such multi-modality volumes registrations would help the physicians in the perspective of navigating their tools in the patient's anatomy to locate structures that are hardly visible in the CBCT used during their procedures. Our code is available at https://github.com/plantonsanti/PartialMatchingVarifolds.

  • Partial Matching in the Space of Varifolds

    by Pierre-Louis Antonsanti, Joan Glaunès, Thomas Benseghir, Vincent Jugnon, Irène Kaltenmark


  • Considerations Regarding Individualization of Head-Related Transfer Functions

    by C.T. Jin, R. Zolfaghari, X. Long, A. Sebastian, S. Hossain, J. Glaunes, A. Tew, M. Shahnawaz, A. Sarti

    This paper provides some considerations regarding using individualized head-related transfer functions for rendering binaural spatial audio over headphones. It briefly considers the degree of benefit that individualization may provide. It then examines the degree of variation existing within the ear morphology across listeners within the Sydney-York Morphological and Recording of Ears (SYMARE) database using kernel principal component analysis and the large deformation diffeomorphic metric mapping framework. The degree of variation across listeners in the directivity patterns associated with head-related transfer functions is also analyzed as a function of frequency. The variation in ear morphology is related to the variation in the directivity patterns using simple linear regression.


  • Surface Matching Using Normal Cycles

    by Pierre Roussillon, Joan Alexis Glaunès


  • Kernel principal component analysis of the ear morphology

    by Reza Zolfaghari, Nicolas Epain, Craig Jin, Joan Alexis Glaunès, Anthony Tew

    This paper describes features in the ear shape that change across a population of ears and explores the corresponding changes in ear acoustics. The statistical analysis conducted over the space of ear shapes uses a kernel principal component analysis (KPCA). Further, it utilizes the framework of large deformation diffeomorphic metric mapping and the vector space that is constructed over the space of initial momentums, which describes the diffeomorphic transformations from the reference template ear shape. The population of ear shapes examined by the KPCA are 124 left and right ear shapes from the SYMARE database that were rigidly aligned to the template (population average) ear. In the work presented here we show the morphological variations captured by the first two kernel principal components, and also show the acoustic transfer functions of the ears which are computed using fast multipole boundary element method simulations.


  • Generating a morphable model of ears

    by Reza Zolfaghari, Nicolas Epain, Craig T. Jin, Joan Glaunes, Anthony Tew

    This paper describes the generation of a morphable model for external ear shapes. The aim for the morphable model is to characterize an ear shape using only a few parameters in order to assist the study of morphoacoustics. The model is derived from a statistical analysis of a population of 58 ears from the SYMARE database. It is based upon the framework of large deformation diffeomorphic metric mapping (LDDMM) and the vector space that is constructed over the space of initial momentums describing the diffeomorphic transformations. To develop a morphable model using the LDDMM framework, the initial momentums are analyzed using a kernel based principal component analysis. In this paper, we examine the ability of our morphable model to construct test ear shapes not included in the principal component analysis.


  • Kernel Metrics on Normal Cycles and Application to Curve Matching

    by Pierre Roussillon, Joan Alexis Glaunès

    In this work we introduce a new dissimilarity measure for shape registration using the notion of normal cycles, a concept from geometric measure theory which allows us to generalize curvature for nonsmooth subsets of the Euclidean space. Our construction is based on the definition of kernel metrics on the space of normal cycles which take explicit expressions in a discrete setting. This approach is closely similar to previous works based on currents and varifolds [M. Vaillant and J. Glaunès, Surface matching via currents, in Information Processing in Medical Imaging, G. E. Christensen and M. Sonka, eds., Lecture Notes in Comput. Sci. 3565, Springer, Berlin, 2005, pp. 381--392; N. Charon and A. Trouvé, SIAM J. Imaging Sci., 6 (2013), pp. 2547--2580]. We derive the computational setting for discrete curves in $\mathbb{R}^3$, using the large deformation diffeomorphic metric mapping framework as the model for deformations. We present synthetic and real data experiments and compare them with the currents and v...


  • Open Access

    Incomplete Hippocampal Inversion: A Comprehensive MRI Study of Over 2000 Subjects

    by Claire Cury, Roberto Toro, Fanny Cohen, Clara Fischer, Amel Mhaya, Jorge Samper-González, Dominique Hasboun, Jean-François Mangin, Tobias Banaschewski, Arun L W Bokde, et al.

    The incomplete-hippocampal-inversion (IHI), also known as malrotation, is an atypical anatomical pattern of the hippocampus, which has been reported in healthy subjects in different studies. However, extensive characterization of IHI in a large sample has not yet been performed. Furthermore, it is unclear whether IHI are restricted to the medial-temporal lobe or are associated with more extensive anatomical changes. Here, we studied the characteristics of IHI in a community-based sample of 2008 subjects of the IMAGEN database and their association with extra-hippocampal anatomical variations. The presence of IHI was assessed on T1-weighted anatomical magnetic resonance imaging (MRI) using visual criteria. We assessed the association of IHI with other anatomical changes throughout the brain using automatic morphometry of cortical sulci. We found that IHI were much more frequent in the left hippocampus (left: 17%, right: 6%, χ2-test, p<10-28). Compared to subjects without IHI, subjects with IHI displayed morphological changes in several sulci located mainly in the limbic lobe. Our results demonstrate that IHI are a common left-sided phenomenon in normal subjects and that they are associated with morphological changes outside the medial temporal lobe.