HNHossein Nejadi-Koti

Hossein Nejadi-Koti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hossein Nejadi-Koti has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Jawad Faiz

    Center of Excellence on Applied Electromagnetic Systems, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Iran

    6 shared publications
  • A. H. Exiri

    Center of Excellence on Applied Electromagnetic Systems School of Electrical and Computer Engineering, University of Tehran, Tehran, Iran

    2 shared publications
  • Amir Hossein Exiri

    Center of Excellence on Applied Electromagnetic Systems, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran

    1 shared publication
  • J. Faiz

    University of Tehran; School of Electrical and Computer Engineering, College of Engineering, Tehran, Iran

    1 shared publication
  • Jawad Faiz

    University of Tehran

    1 shared publication
  • Mehran Keravand

    Center of Excellence on Applied Electromagnetic Systems, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Iran

    1 shared publication

Latest Publications

  • Inductance-based Inter-Turn Fault Detection in Permanent Magnet Synchronous Machine Using Magnetic Equivalent Circuit Model

    by Jawad Faiz, Jawad Faiz, Hossein Nejadi-Koti, Hossein Nejadi-Koti, Amir Hossein Exiri, Amir Hossein Exiri

    This paper presents an inductance-based method for detection of inter-turn fault in permanent magnet synchronous machines (PMSM). The reason for using inductance for fault detection and its severity estimation is the obvious impact of the fault on the inductances. This fault reduces the effective number of turns and therefore inductances. The PMSM is modeled using magnetic equivalent circuit (MEC). This method takes into account the impacts of stator teeth, rotor yoke, and stator winding distribution precisely. So, it is shown that the MEC method is superior to other analytical methods such as winding function. The governing equations in different parts of the machine are proposed, and the MEC equations of the PMSM are developed. First, healthy and faulty PMSM is simulated using MEC for different severities of the fault. In the 2nd stage, the required analytical equations for self-inductance and mutual inductance estimation are extracted, and the impact of the fault severity upon these inductances is determined. Finally, inter-turn short-circuit fault is detected, and its severity is determined using the amplitude of the inductance of the faulty phase. Simulation results and the proposed fault diagnosis method are validated using finite elements method.


  • Uniform demagnetization fault diagnosis in permanent magnet synchronous motors by means of cogging torque analysis

    by Hossein Nejadi-Koti, Jawad Faiz, Nabeel A. O. Demerdash

    A demagnetization fault in permanent magnet type motors is a common fault that can lead to deterioration of the machine performance, and would introduce secondary problems. Detection of this type of fault, and establishing diagnosis methods to detect such a fault, requires knowledge of a motor working principles and its structure. Moreover, a uniform demagnetization type of fault is extremely hard to detect, because it results-in no asymmetry in the output/terminal signals, and hence, motor current signal analysis (MCSA) methods fail to diagnose such faults. In this paper, internal permanent magnet synchronous motors (IPMSMs) with two different rotor configurations are studied/simulated using a two-dimensional finite element (2D-FE) method, by means of which the cogging torque signal is computed under healthy and faulty conditions. Uniform demagnetization is studied and a proper fault diagnosis index is introduced which can successfully detect this type of fault.


  • Significance of rotor slots number on induction motor operation under broken bars

    by W. Abu Elhaija, V. Ghorbanian, J. Faiz, H. Nejadi-Koti

    This paper investigates the effect of the rotor slots (bars) number of a three phase squirrel cage induction motor on the motor performance under broken bar fault condition. Two motors have been investigated at full load condition in healthy bars, one broken bar and two broken bars operations. The first motor has 24 stator slots and is investigated with rotor slots 20, 29 and 32 and the second motor has 36 slots and is investigated with rotor slots 28 and 44. The above-mentioned rotor slots numbers have been selected based on manufacturer's database. The effect of rotor slots numbers on motor performance with broken bars fault has been observed by analyzing the stator current emerging frequency components, steady state copper losses, slip at full load and steady state bar currents. Recommendation for the safest stator and rotor slots combinations has been provided based on simulated key performance indicators.


  • Finite element analysis of healthy and faulty permanent magnet synchronous motors used in hybrid vehicles

    by Jawad Faiz, H. Nejadi-Koti, Mehran Keravand

    Precise simulation of permanent magnet synchronous motors (PMSM) is the most important part in many cases particularly in their fault diagnosis and optimal control. This paper introduces different simulation methods of PMSM where finite elements method (FEM) is chosen as computation tools. The logic and problem solving is investigated and positive and negative points are described. Then, the trend of simulation using FEM is explained and a PMSM used in hybrid vehicles is simulated under healthy and faulty conditions and the results are discussed. Finally, short circuit fault in a PMSM is diagnosed using the stator phase currents.

  • Comprehensive review on inter‐turn fault indexes in permanent magnet motors

    by Jawad Faiz, Hossein Nejadi‐Koti, Zahra Valipour

    Inter‐turn fault (ITF) of stator winding is a very sensitive and critical fault in permanent magnet motors. If this fault is not diagnosed on‐time, it can quickly expand and generate serious damage and even full damage to the motor. So, realisation of this fault, its impact on the motors and finally its diagnosis methods are essential and has high priorityfor users of the motors. This study presents the trend of the negative impacts of the fault on the performance of the machine. Available indexes for this fault detection are introduced and described in details. By analysing these indexes, their merits and drawbacks, limitations and ambiguous points are extracted. Finally, these indexes are compared and the best and worst indexes are introduced. Moreover, one of the most used index and the simplest one will be simulated in order to show capability of a new current‐based ITF diagnosis index.


  • Current-based inter-turn short circuit fault modeling in permanent magnet synchronous machine using magnetic equivalent circuit model

    by Jawad Faiz, A. H. Exiri, H. Nejadi-Koti

    Stator current signal analysis is used to diagnosis inter-turn short circuit fault in permanent magnet synchronous machines (PMSM). The PMSM is modeled using magnetic equivalent circuit (MEC). This method takes into account the impacts of stator teeth, rotor yoke and stator winding distribution precisely. First healthy and faulty PMSM is simulated for different fault severities. In the 2nd step, inter-turn short circuit fault is detected and its severity is determined using the amplitude of the side band components of the stator current. Finally, the frequency components of the extended Park vector magnitude are employed as the 2nd index for fault detection. This index is independent of the load and only depends on the fault severity.


  • Simulation of permanent magnet synchronous motors under short circuit fault

    by Jawad Faiz, A. H. Exiri, H. Nejadi-Koti

    In this paper short circuit fault in permanent magnet synchronous motors (PMSMs) is proposed. The reasons for breakdown of insulation system of the PMSMs are presented and impacts of the fault upon its performance are discussed. First a healthy PMSM is simulated using magnetic equivalent circuit. This method takes into account the impacts of stator teeth, rotor yoke and stator winding distribution. The turn-to-turn fault as incipient fault and also coil-to-coil, phase-to-earth, two-phase-to-earth and three-phase-to-earth faults are proposed and their impacts on the different operational signals of the machine are investigated.


  • Demagnetization Fault Indexes in Permanent Magnet Synchronous Motors—An Overview

    by Jawad Faiz, H. Nejadi-Koti

    Demagnetization fault is the most widespread fault in permanent magnet synchronous motors (PMSMs). Diagnosing this fault and extracting appropriate indexes for the PMSM are proposed and discussed in this paper. The index-extracting techniques and their advantages, disadvantages, and significant ambiguities are proposed, and it is emphasized how these ambiguities can be eliminated. This can help the newcomers to this field as well as designers and manufacturers of protection and fault diagnosis industry. In light of this information, the readers will have a full view on different aspects of each index. An optimum index can be chosen based on the sensitivity of application and the cost of index implementation.