Jens Höfflin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jens Höfflin has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Jan Gerrit Korvink
Institute of Microstructure Technology Karlsruhe Institute of Technology Eggenstein‐Leopoldshafen Germany
5 shared publications - Ulrike Wallrabe
Department of Microsystems Engineering (IMTEK) Laboratory for Microactuators Albert‐Ludwigs‐Universität Freiburg Freiburg Germany
2 shared publications - Vlad Badilita
Karlsruhe Institute of Technology
2 shared publications Aldric H. Bouffard
Department of Stem Cell and Regenerative Biology and the Harvard Stem Cell Institute Harvard University Cambridge MA USA
1 shared publication- Alexander Kreymerman
Spencer Center for Vision Research, Byers Eye Institute, Stanford University, Palo Alto, CA 94303, USA
1 shared publication Ali Moazenzadeh
Laboratory for Microactuators, IMTEK–Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
1 shared publication
Latest Publications
- Open Access
- 2 July 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (13) , e033155
P53 Activation Promotes Maturational Characteristics of Pluripotent Stem Cell‐Derived Cardiomyocytes in 3‐Dimensional Suspension Culture Via FOXO‐FOXM1 Regulation
Background: Current protocols generate highly pure human induced pluripotent stem cell–derived cardiomyocytes (hiPSC‐CMs) in vitro that recapitulate characteristics of mature in vivo cardiomyocytes. Yet, a risk of arrhythmias exists when hiPSC‐CMs are injected into large animal models. Thus, understanding hiPSC‐CM maturational mechanisms is crucial for clinical translation. Forkhead box (FOX) transcription factors regulate postnatal cardiomyocyte maturation through a balance between FOXO and FOXM1. We also previously demonstrated that p53 activation enhances hiPSC‐CM maturation. Here, we investigate whether p53 activation modulates the FOXO/FOXM1 balance to promote hiPSC‐CM maturation in 3‐dimensional suspension culture. Methods and Results: Three‐dimensional cultures of hiPSC‐CMs were treated with Nutlin‐3a (p53 activator, 10 μM), LOM612 (FOXO relocator, 5 μM), AS1842856 (FOXO inhibitor, 1 μM), or RCM‐1 (FOXM1 inhibitor, 1 μM), starting 2 days after onset of beating, with dimethyl sulfoxide (0.2% vehicle) as control. P53 activation promoted hiPSC‐CM metabolic and electrophysiological maturation alongside FOXO upregulation and FOXM1 downregulation, in n=3 to 6 per group for all assays. FOXO inhibition significantly decreased expression of cardiac‐specific markers such as TNNT2. In contrast, FOXO activation or FOXM1 inhibition promoted maturational characteristics such as increased contractility, oxygen consumption, and voltage peak maximum upstroke velocity, in n=3 to 6 per group for all assays. Further, by single‐cell RNA sequencing of n=2 LOM612‐treated cells compared with dimethyl sulfoxide, LOM612‐mediated FOXO activation promoted expression of cardiac maturational pathways. Conclusions: We show that p53 activation promotes FOXO and suppresses FOXM1 during 3‐dimensional hiPSC‐CM maturation. These results expand our understanding of hiPSC‐CM maturational mechanisms in a clinically‐relevant 3‐dimensional culture system.
- 2 July 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (13) , e033155
Open AccessP53 Activation Promotes Maturational Characteristics of Pluripotent Stem Cell‐Derived Cardiomyocytes in 3‐Dimensional Suspension Culture Via FOXO‐FOXM1 Regulation
Background: Current protocols generate highly pure human induced pluripotent stem cell–derived cardiomyocytes (hiPSC‐CMs) in vitro that recapitulate characteristics of mature in vivo cardiomyocytes. Yet, a risk of arrhythmias exists when hiPSC‐CMs are injected into large animal models. Thus, understanding hiPSC‐CM maturational mechanisms is crucial for clinical translation. Forkhead box (FOX) transcription factors regulate postnatal cardiomyocyte maturation through a balance between FOXO and FOXM1. We also previously demonstrated that p53 activation enhances hiPSC‐CM maturation. Here, we investigate whether p53 activation modulates the FOXO/FOXM1 balance to promote hiPSC‐CM maturation in 3‐dimensional suspension culture. Methods and Results: Three‐dimensional cultures of hiPSC‐CMs were treated with Nutlin‐3a (p53 activator, 10 μM), LOM612 (FOXO relocator, 5 μM), AS1842856 (FOXO inhibitor, 1 μM), or RCM‐1 (FOXM1 inhibitor, 1 μM), starting 2 days after onset of beating, with dimethyl sulfoxide (0.2% vehicle) as control. P53 activation promoted hiPSC‐CM metabolic and electrophysiological maturation alongside FOXO upregulation and FOXM1 downregulation, in n=3 to 6 per group for all assays. FOXO inhibition significantly decreased expression of cardiac‐specific markers such as TNNT2. In contrast, FOXO activation or FOXM1 inhibition promoted maturational characteristics such as increased contractility, oxygen consumption, and voltage peak maximum upstroke velocity, in n=3 to 6 per group for all assays. Further, by single‐cell RNA sequencing of n=2 LOM612‐treated cells compared with dimethyl sulfoxide, LOM612‐mediated FOXO activation promoted expression of cardiac maturational pathways. Conclusions: We show that p53 activation promotes FOXO and suppresses FOXM1 during 3‐dimensional hiPSC‐CM maturation. These results expand our understanding of hiPSC‐CM maturational mechanisms in a clinically‐relevant 3‐dimensional culture system.
- Open Access
- 5 January 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (1) , e0146384
Heteronuclear Micro-Helmholtz Coil Facilitates µm-Range Spatial and Sub-Hz Spectral Resolution NMR of nL-Volume Samples on Customisable Microfluidic Chips
We present a completely revised generation of a modular micro-NMR detector, featuring an active sample volume of ∼ 100 nL, and an improvement of 87% in probe efficiency. The detector is capable of rapidly screening different samples using exchangeable, application-specific, MEMS-fabricated, microfluidic sample containers. In contrast to our previous design, the sample holder chips can be simply sealed with adhesive tape, with excellent adhesion due to the smooth surfaces surrounding the fluidic ports, and so withstand pressures of ∼2.5 bar, while simultaneously enabling high spectral resolution up to 0.62 Hz for H2O, due to its optimised geometry. We have additionally reworked the coil design and fabrication processes, replacing liquid photoresists by dry film stock, whose final thickness does not depend on accurate volume dispensing or precise levelling during curing. We further introduced mechanical alignment structures to avoid time-intensive optical alignment of the chip stacks during assembly, while we exchanged the laser-cut, PMMA spacers by diced glass spacers, which are not susceptible to melting during cutting. Doing so led to an overall simplification of the entire fabrication chain, while simultaneously increasing the yield, due to an improved uniformity of thickness of the individual layers, and in addition, due to more accurate vertical positioning of the wirebonded coils, now delimited by a post base plateau. We demonstrate the capability of the design by acquiring a 1H spectrum of ∼ 11 nmol sucrose dissolved in D2O, where we achieved a linewidth of 1.25 Hz for the TSP reference peak. Chemical shift imaging experiments were further recorded from voxel volumes of only ∼ 1.5nL, which corresponded to amounts of just 1.5 nmol per voxel for a 1 M concentration. To extend the micro-detector to other nuclei of interest, we have implemented a trap circuit, enabling heteronuclear spectroscopy, demonstrated by two 1H/13C 2D HSQC experiments.
- 5 January 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (1) , e0146384
Open AccessHeteronuclear Micro-Helmholtz Coil Facilitates µm-Range Spatial and Sub-Hz Spectral Resolution NMR of nL-Volume Samples on Customisable Microfluidic Chips
We present a completely revised generation of a modular micro-NMR detector, featuring an active sample volume of ∼ 100 nL, and an improvement of 87% in probe efficiency. The detector is capable of rapidly screening different samples using exchangeable, application-specific, MEMS-fabricated, microfluidic sample containers. In contrast to our previous design, the sample holder chips can be simply sealed with adhesive tape, with excellent adhesion due to the smooth surfaces surrounding the fluidic ports, and so withstand pressures of ∼2.5 bar, while simultaneously enabling high spectral resolution up to 0.62 Hz for H2O, due to its optimised geometry. We have additionally reworked the coil design and fabrication processes, replacing liquid photoresists by dry film stock, whose final thickness does not depend on accurate volume dispensing or precise levelling during curing. We further introduced mechanical alignment structures to avoid time-intensive optical alignment of the chip stacks during assembly, while we exchanged the laser-cut, PMMA spacers by diced glass spacers, which are not susceptible to melting during cutting. Doing so led to an overall simplification of the entire fabrication chain, while simultaneously increasing the yield, due to an improved uniformity of thickness of the individual layers, and in addition, due to more accurate vertical positioning of the wirebonded coils, now delimited by a post base plateau. We demonstrate the capability of the design by acquiring a 1H spectrum of ∼ 11 nmol sucrose dissolved in D2O, where we achieved a linewidth of 1.25 Hz for the TSP reference peak. Chemical shift imaging experiments were further recorded from voxel volumes of only ∼ 1.5nL, which corresponded to amounts of just 1.5 nmol per voxel for a 1 M concentration. To extend the micro-detector to other nuclei of interest, we have implemented a trap circuit, enabling heteronuclear spectroscopy, demonstrated by two 1H/13C 2D HSQC experiments.
- 19 May 2015
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 25 (6)
Ink-jet printing technology enables self-aligned mould patterning for electroplating in a single step
We present a new self-aligned, mask-free micro-fabrication method with which to form thick-layered conductive metal micro-structures inside electroplating moulds. Seed layer patterning for electroplating was performed by ink-jet printing using a silver nano-particle ink deposited on SU-8 or Ordyl SY permanent resist. The silver ink contact angle on SU-8 was adjusted by oxygen plasma followed by a hard bake. Besides functioning as a seed layer, the printed structures further served as a shadow mask during patterning of electroplating moulds into negative photoresist. The printed silver tracks remained in strong adhesion to the substrate when exposed to the acidic chemistry of the electroplating bath. To demonstrate the process, we manufactured rectangular, low-resistivity planar micro-coils for use in magnetic resonance microscopy. MRI images of a spring onion with an in-plane resolution down to 10 µm × 10 µm were acquired using a micro-coil on an 11.7 T MRI scanner.
- 19 May 2015
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 25 (6)
Ink-jet printing technology enables self-aligned mould patterning for electroplating in a single step
We present a new self-aligned, mask-free micro-fabrication method with which to form thick-layered conductive metal micro-structures inside electroplating moulds. Seed layer patterning for electroplating was performed by ink-jet printing using a silver nano-particle ink deposited on SU-8 or Ordyl SY permanent resist. The silver ink contact angle on SU-8 was adjusted by oxygen plasma followed by a hard bake. Besides functioning as a seed layer, the printed structures further served as a shadow mask during patterning of electroplating moulds into negative photoresist. The printed silver tracks remained in strong adhesion to the substrate when exposed to the acidic chemistry of the electroplating bath. To demonstrate the process, we manufactured rectangular, low-resistivity planar micro-coils for use in magnetic resonance microscopy. MRI images of a spring onion with an in-plane resolution down to 10 µm × 10 µm were acquired using a micro-coil on an 11.7 T MRI scanner.
- 4 May 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (12) , 2584-2587
Electrifying the disk: a modular rotating platform for wireless power and data transmission for Lab on a disk application
We present a design for wireless power transfer, via inductively coupled coils, to a spinning disk. The rectified and stabilised power feeds an Arduino-compatible microcontroller (μC) on the disc, which in turn drives and monitors various sensors and actuators. The platform, which has been conceived to flexibly prototype such systems, demonstrates the feasibility of a wireless power supply and the use of a μC circuit, for example for Lab-on-a-disk applications, thereby eliminating the need for cumbersome slip rings or batteries, and adding a cogent and new degree of freedom to the setup. The large number of sensors and actuators included demonstrate that a wide range of physical parameters can be easily monitored and altered. All devices are connected to the μC via an I2C bus, therefore can be easily exchanged or augmented by other devices in order to perform a specific task on the disk. The wireless power supply takes up little additional physical space and should work in conjunction with most existing Lab-on-a-disk platforms as a straightforward add-on, since it does not require modification of the rotation axis and can be readily adapted to specific geometrical requirements.
- 4 May 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (12) , 2584-2587
Electrifying the disk: a modular rotating platform for wireless power and data transmission for Lab on a disk application
We present a design for wireless power transfer, via inductively coupled coils, to a spinning disk. The rectified and stabilised power feeds an Arduino-compatible microcontroller (μC) on the disc, which in turn drives and monitors various sensors and actuators. The platform, which has been conceived to flexibly prototype such systems, demonstrates the feasibility of a wireless power supply and the use of a μC circuit, for example for Lab-on-a-disk applications, thereby eliminating the need for cumbersome slip rings or batteries, and adding a cogent and new degree of freedom to the setup. The large number of sensors and actuators included demonstrate that a wide range of physical parameters can be easily monitored and altered. All devices are connected to the μC via an I2C bus, therefore can be easily exchanged or augmented by other devices in order to perform a specific task on the disk. The wireless power supply takes up little additional physical space and should work in conjunction with most existing Lab-on-a-disk platforms as a straightforward add-on, since it does not require modification of the rotation axis and can be readily adapted to specific geometrical requirements.
- 1 April 2015
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 45 (2) , 97-105
Subthreshold CMOS transistors are largely immune to magnetic field effects when operated above 11 T
We report on measurements of n‐channel field‐effect transistor structures with multiple drain/source contacts, fabricated in a commercial complementary metal‐oxide‐semiconductor (CMOS) technology, at high magnetic field strengths. The focus lies on field dependent effects such as the Hall effect to better understand how these key electronic devices behave when their embedding circuits are immersed in strong magnetic fields. In addition, measurement results of relevant electrical parameters for circuit design, i.e., the saturation current of IDS as well as the slope of IDS and threshold voltage Vt will be shown. The results are in agreement with theory and it is possible to predict the Hall voltage as well as the channel resistance. This allows to simulate noise behavior of amplifiers using silicon MOSFETs in high magnetic fields. The measurements show that, electrically, CMOS transistors operated in subthreshold mode are largely immune to magnetic field effects when operated above 11 T. © 2015 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 45B: 97–105, 2015
- 1 April 2015
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 45 (2) , 97-105
Subthreshold CMOS transistors are largely immune to magnetic field effects when operated above 11 T
We report on measurements of n‐channel field‐effect transistor structures with multiple drain/source contacts, fabricated in a commercial complementary metal‐oxide‐semiconductor (CMOS) technology, at high magnetic field strengths. The focus lies on field dependent effects such as the Hall effect to better understand how these key electronic devices behave when their embedding circuits are immersed in strong magnetic fields. In addition, measurement results of relevant electrical parameters for circuit design, i.e., the saturation current of IDS as well as the slope of IDS and threshold voltage Vt will be shown. The results are in agreement with theory and it is possible to predict the Hall voltage as well as the channel resistance. This allows to simulate noise behavior of amplifiers using silicon MOSFETs in high magnetic fields. The measurements show that, electrically, CMOS transistors operated in subthreshold mode are largely immune to magnetic field effects when operated above 11 T. © 2015 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 45B: 97–105, 2015
- 25 March 2014
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 24 (4)
Microfluidic integration of wirebonded microcoils for on-chip applications in nuclear magnetic resonance
- 25 March 2014
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 24 (4)
Microfluidic integration of wirebonded microcoils for on-chip applications in nuclear magnetic resonance