Jean-François Chateaux
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jean-François Chateaux has a total of 109 co-authors. Here are the top co-authors by number of shared publications:
P. Morin
INL Institut des Nanotechnologies de Lyon , Villeurbanne , France ; CNRS UMR5270 , Villeurbanne , France ; Université de Lyon , Lyon , France
6 shared publicationsMohamed Braiek
5 shared publicationsA. Briguet
CREATIS-LRMN, CNRS, UMR 5220, Villeurbanne F-69621, France
4 shared publicationsAnne-Laure Deman
Université de Lyon, Institut des Nanotechnologies de Lyon INL-UMR5270, Université Lyon 1, Villeurbanne F-69622, France
4 shared publicationsNicole Jaffrezic-Renault
4 shared publications- Nicoleta Baxan
National Heart and Lung Institute, Faculty of Medicine, Imperial College London, London, UK
4 shared publications
Latest Publications
- 1 October 2018
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 117, 669-677
Xurography-based microfluidic algal biosensor and dedicated portable measurement station for online monitoring of urban polluted samples
- 1 October 2018
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 117, 669-677
Xurography-based microfluidic algal biosensor and dedicated portable measurement station for online monitoring of urban polluted samples
- 1 February 2018
- Published by Elsevier in Microelectronic Engineering
- Vol. 187-188, 43-49
A conductometric creatinine biosensor prepared through contact printing of polyvinyl alcohol/polyethyleneimine based enzymatic membrane
- 1 February 2018
- Published by Elsevier in Microelectronic Engineering
- Vol. 187-188, 43-49
A conductometric creatinine biosensor prepared through contact printing of polyvinyl alcohol/polyethyleneimine based enzymatic membrane
- 27 October 2017
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 21 (11) , 170
Anisotropic composite polymer for high magnetic force in microfluidic systems
- 27 October 2017
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 21 (11) , 170
Anisotropic composite polymer for high magnetic force in microfluidic systems
- Open Access
Recent Advances in Electrospun Nanofiber Interfaces for Biosensing Devices
Electrospinning has emerged as a very powerful method combining efficiency, versatility and low cost to elaborate scalable ordered and complex nanofibrous assemblies from a rich variety of polymers. Electrospun nanofibers have demonstrated high potential for a wide spectrum of applications, including drug delivery, tissue engineering, energy conversion and storage, or physical and chemical sensors. The number of works related to biosensing devices integrating electrospun nanofibers has also increased substantially over the last decade. This review provides an overview of the current research activities and new trends in the field. Retaining the bioreceptor functionality is one of the main challenges associated with the production of nanofiber-based biosensing interfaces. The bioreceptors can be immobilized using various strategies, depending on the physical and chemical characteristics of both bioreceptors and nanofiber scaffolds, and on their interfacial interactions. The production of nanobiocomposites constituted by carbon, metal oxide or polymer electrospun nanofibers integrating bioreceptors and conductive nanomaterials (e.g., carbon nanotubes, metal nanoparticles) has been one of the major trends in the last few years. The use of electrospun nanofibers in ELISA-type bioassays, lab-on-a-chip and paper-based point-of-care devices is also highly promising. After a short and general description of electrospinning process, the different strategies to produce electrospun nanofiber biosensing interfaces are discussed.
Open AccessRecent Advances in Electrospun Nanofiber Interfaces for Biosensing Devices
Electrospinning has emerged as a very powerful method combining efficiency, versatility and low cost to elaborate scalable ordered and complex nanofibrous assemblies from a rich variety of polymers. Electrospun nanofibers have demonstrated high potential for a wide spectrum of applications, including drug delivery, tissue engineering, energy conversion and storage, or physical and chemical sensors. The number of works related to biosensing devices integrating electrospun nanofibers has also increased substantially over the last decade. This review provides an overview of the current research activities and new trends in the field. Retaining the bioreceptor functionality is one of the main challenges associated with the production of nanofiber-based biosensing interfaces. The bioreceptors can be immobilized using various strategies, depending on the physical and chemical characteristics of both bioreceptors and nanofiber scaffolds, and on their interfacial interactions. The production of nanobiocomposites constituted by carbon, metal oxide or polymer electrospun nanofibers integrating bioreceptors and conductive nanomaterials (e.g., carbon nanotubes, metal nanoparticles) has been one of the major trends in the last few years. The use of electrospun nanofibers in ELISA-type bioassays, lab-on-a-chip and paper-based point-of-care devices is also highly promising. After a short and general description of electrospinning process, the different strategies to produce electrospun nanofiber biosensing interfaces are discussed.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2017 (1557170X) , 3584-3587
Determination of Red Blood Cell fatigue using electrodeformation
In this work, we used electrodeformation (ED) [1] as a new strategy to evaluate the fatigue of healthy human Red Blood Cells (RBCs). Using dielectrophoresis (DEP) forces, we submitted RBCs to a series of elongation and relaxation cycles to model their mechanical stress in the blood circulation and we used their relaxation time as a marker to evaluate their fatigue. In this paper, we first investigated the dependency of the RBC mechanical response upon the experimental parameters, such as the viscosity η out of the external medium, the amplitude ΔV of the applied voltage, the duration of the solicitation t sol , the number of solicitations N as well as the resting time t rest between two solicitations. The impact of these parameters was evaluated through the analysis of both RBC deformation index D and relaxation time τ. Finally, the optimization of these parameters was used to monitor RBC fatigue.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2017 (1557170X) , 3584-3587
Determination of Red Blood Cell fatigue using electrodeformation
In this work, we used electrodeformation (ED) [1] as a new strategy to evaluate the fatigue of healthy human Red Blood Cells (RBCs). Using dielectrophoresis (DEP) forces, we submitted RBCs to a series of elongation and relaxation cycles to model their mechanical stress in the blood circulation and we used their relaxation time as a marker to evaluate their fatigue. In this paper, we first investigated the dependency of the RBC mechanical response upon the experimental parameters, such as the viscosity η out of the external medium, the amplitude ΔV of the applied voltage, the duration of the solicitation t sol , the number of solicitations N as well as the resting time t rest between two solicitations. The impact of these parameters was evaluated through the analysis of both RBC deformation index D and relaxation time τ. Finally, the optimization of these parameters was used to monitor RBC fatigue.
- 1 November 2016
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 235, 27-32
A conductometric sensor for potassium detection in whole blood
- 1 November 2016
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 235, 27-32
A conductometric sensor for potassium detection in whole blood
- 1 September 2015
- Published by AIP Publishing in Biomicrofluidics
- Vol. 9 (5) , 054104
Dielectrophoretic capture of low abundance cell population using thick electrodes
Enrichment of rare cell populations such as Circulating Tumor Cells (CTCs) is a critical step before performing analysis. This paper presents a polymeric microfluidic device with integrated thick Carbon-PolyDimethylSiloxane composite (C-PDMS) electrodes designed to carry out dielectrophoretic (DEP) trapping of low abundance biological cells. Such conductive composite material presents advantages over metallic structures. Indeed, as it combines properties of both the matrix and doping particles, C-PDMS allows the easy and fast integration of conductive microstructures using a soft-lithography approach while preserving O2 plasma bonding properties of PDMS substrate and avoiding a cumbersome alignment procedure. Here, we first performed numerical simulations to demonstrate the advantage of such thick C-PDMS electrodes over a coplanar electrode configuration. It is well established that dielectrophoretic force ( ) decreases quickly as the distance from the electrode surface increases resulting in coplanar configuration to a low trapping efficiency at high flow rate. Here, we showed quantitatively that by using electrodes as thick as a microchannel height, it is possible to extend the DEP force influence in the whole volume of the channel compared to coplanar electrode configuration and maintaining high trapping efficiency while increasing the throughput. This model was then used to numerically optimize a thick C-PDMS electrode configuration in terms of trapping efficiency. Then, optimized microfluidic configurations were fabricated and tested at various flow rates for the trapping of MDA-MB-231 breast cancer cell line. We reached trapping efficiencies of 97% at 20 μl/h and 78.7% at 80 μl/h, for 100 μm thick electrodes. Finally, we applied our device to the separation and localized trapping of CTCs (MDA-MB-231) from a red blood cells sample (concentration ratio of 1:10).- 1 September 2015
- Published by AIP Publishing in Biomicrofluidics
- Vol. 9 (5) , 054104
Dielectrophoretic capture of low abundance cell population using thick electrodes
Enrichment of rare cell populations such as Circulating Tumor Cells (CTCs) is a critical step before performing analysis. This paper presents a polymeric microfluidic device with integrated thick Carbon-PolyDimethylSiloxane composite (C-PDMS) electrodes designed to carry out dielectrophoretic (DEP) trapping of low abundance biological cells. Such conductive composite material presents advantages over metallic structures. Indeed, as it combines properties of both the matrix and doping particles, C-PDMS allows the easy and fast integration of conductive microstructures using a soft-lithography approach while preserving O2 plasma bonding properties of PDMS substrate and avoiding a cumbersome alignment procedure. Here, we first performed numerical simulations to demonstrate the advantage of such thick C-PDMS electrodes over a coplanar electrode configuration. It is well established that dielectrophoretic force ( ) decreases quickly as the distance from the electrode surface increases resulting in coplanar configuration to a low trapping efficiency at high flow rate. Here, we showed quantitatively that by using electrodes as thick as a microchannel height, it is possible to extend the DEP force influence in the whole volume of the channel compared to coplanar electrode configuration and maintaining high trapping efficiency while increasing the throughput. This model was then used to numerically optimize a thick C-PDMS electrode configuration in terms of trapping efficiency. Then, optimized microfluidic configurations were fabricated and tested at various flow rates for the trapping of MDA-MB-231 breast cancer cell line. We reached trapping efficiencies of 97% at 20 μl/h and 78.7% at 80 μl/h, for 100 μm thick electrodes. Finally, we applied our device to the separation and localized trapping of CTCs (MDA-MB-231) from a red blood cells sample (concentration ratio of 1:10).- Open Access
- 30 July 2015
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 162 (10) , B275-B281
One-Step Fabrication of Electrospun Photo-Cross-Linkable Polymer Nanofibers Incorporating Multiwall Carbon Nanotubes and Enzyme for Biosensing
Herein, we report the easy and rapid fabrication of water-stable electrospun nanofibers from blends of the photochemically cross-linkable polyvinyl alcohol styrylpyridinium polymer (PVA-SbQ), carboxylated multiwall carbon nanotubes (MWCNT-COOHs) and glucose oxidase (GOx) for electrochemical biosensor application. Different electrospinning parameters including flow rate, applied voltage, distance between tip and collector, polymer concentration and MWCNT-COOHs content in the electrospun solution were tailored to produce PVA-SbQ/MWCNT-COOH nanofibers with minimal beading and enhanced electrical properties. Optimal PVA-SbQ and MWCNT-COOHs concentrations were 6.7 wt% and 5 wt% with respect to the total solution and polymer mass, respectively. The nanofibers were rendered water insoluble via exposure to UV irradiation for 10 min. The electrochemical properties of electrospun PVA-SbQ/MWCNT-COOH nanofibrous mats were characterized by cyclic voltammetry and electrochemical impedance spectroscopy. Scanning electron microscopy and transmission electron microscopy were used to characterize the morphology of the nanofibers. GOx, used as model enzyme, was further incorporated into the PVA-SbQ/MWCNT-COOH mixture before electrospinning. The obtained biosensor enabled successful detection of glucose by cyclic voltammetry. The resulting novel glucose biosensor revealed very good storage and operational stabilities, a low limit of detection (2 μM) and a wide linear range (up to at least 4 mM).
- 30 July 2015
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 162 (10) , B275-B281
Open AccessOne-Step Fabrication of Electrospun Photo-Cross-Linkable Polymer Nanofibers Incorporating Multiwall Carbon Nanotubes and Enzyme for Biosensing
Herein, we report the easy and rapid fabrication of water-stable electrospun nanofibers from blends of the photochemically cross-linkable polyvinyl alcohol styrylpyridinium polymer (PVA-SbQ), carboxylated multiwall carbon nanotubes (MWCNT-COOHs) and glucose oxidase (GOx) for electrochemical biosensor application. Different electrospinning parameters including flow rate, applied voltage, distance between tip and collector, polymer concentration and MWCNT-COOHs content in the electrospun solution were tailored to produce PVA-SbQ/MWCNT-COOH nanofibers with minimal beading and enhanced electrical properties. Optimal PVA-SbQ and MWCNT-COOHs concentrations were 6.7 wt% and 5 wt% with respect to the total solution and polymer mass, respectively. The nanofibers were rendered water insoluble via exposure to UV irradiation for 10 min. The electrochemical properties of electrospun PVA-SbQ/MWCNT-COOH nanofibrous mats were characterized by cyclic voltammetry and electrochemical impedance spectroscopy. Scanning electron microscopy and transmission electron microscopy were used to characterize the morphology of the nanofibers. GOx, used as model enzyme, was further incorporated into the PVA-SbQ/MWCNT-COOH mixture before electrospinning. The obtained biosensor enabled successful detection of glucose by cyclic voltammetry. The resulting novel glucose biosensor revealed very good storage and operational stabilities, a low limit of detection (2 μM) and a wide linear range (up to at least 4 mM).
- Open Access
- 3 July 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , 11814
All-organic electrostrictive polymer composites with low driving electrical voltages for micro-fluidic pump applications
This paper focuses on the improvement of a relaxor ferroelectric terpolymer, i.e., poly (vinylidene fluoride-trifluoroethylene-chlorofluoroethylene) [P(VDF-TrFE-CFE)], filled with a bis(2-ethylhexyl) phthalate (DEHP). The developed material gave rise to a significantly increased longitudinal electrostrictive strain, as well as an increased mechanical energy density under a relatively low electric field. These features were attributed to the considerably enhanced dielectric permittivity and a decreased Young modulus as a result of the introduction of only small DEHP plasticizer molecules. In addition, the plasticizer-filled terpolymer only exhibited a slight decrease of the dielectric breakdown strength, which was a great advantage with respect to the traditional polymer-based electrostrictive composites. More importantly, the approach proposed herein is promising for the future development and scale-up of new high-performance electrostrictive dielectrics under low applied electrical fields through modification simply by blending with a low-cost plasticizer. An experimental demonstration based on a flexible micro-fluidic application is described at the end of this paper, confirming the attractive characteristics of the proposed materials as well as the feasibility of integrating them as micro-actuators in small-scale devices.
- 3 July 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , 11814
Open AccessAll-organic electrostrictive polymer composites with low driving electrical voltages for micro-fluidic pump applications
This paper focuses on the improvement of a relaxor ferroelectric terpolymer, i.e., poly (vinylidene fluoride-trifluoroethylene-chlorofluoroethylene) [P(VDF-TrFE-CFE)], filled with a bis(2-ethylhexyl) phthalate (DEHP). The developed material gave rise to a significantly increased longitudinal electrostrictive strain, as well as an increased mechanical energy density under a relatively low electric field. These features were attributed to the considerably enhanced dielectric permittivity and a decreased Young modulus as a result of the introduction of only small DEHP plasticizer molecules. In addition, the plasticizer-filled terpolymer only exhibited a slight decrease of the dielectric breakdown strength, which was a great advantage with respect to the traditional polymer-based electrostrictive composites. More importantly, the approach proposed herein is promising for the future development and scale-up of new high-performance electrostrictive dielectrics under low applied electrical fields through modification simply by blending with a low-cost plasticizer. An experimental demonstration based on a flexible micro-fluidic application is described at the end of this paper, confirming the attractive characteristics of the proposed materials as well as the feasibility of integrating them as micro-actuators in small-scale devices.