Milan Boublík
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Milan Boublík has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Bohuslav Gaš
Berlin) Christian Klampfl (Linz)
2 shared publications Vlastimil Hruška
Agilent Technologies Deutschland GmbH & Co. KG, Liquid Phase Separations Division, Waldbronn, Germany
2 shared publications- Anastasiia Murmiliuk
Università degli Studi di Milano
1 shared publication Gabriela Kučerová
1 shared publicationJana Svobodová
Agilent Technologies Deutschland GmbH & Co. KG, Liquid Phase Separations Division, Waldbronn, Germany
1 shared publicationJana Šteflová
Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Albertov 6, Prague 2, 128 43, Czech Republic; Agilent Technologies GmbH, Waldbronn, Germany
1 shared publication
Latest Publications
- 24 November 2020
- Published by Royal Society of Chemistry (RSC) in Molecular Systems Design & Engineering
- Vol. 6 (2) , 122-131
Quantitative prediction of charge regulation in oligopeptides
Charge regulation in the peptide Glu5–His5 as a model weak ampholyte: simulations predict deviations from the ideal ionization of free aminoacids, in quantitative agreement with experiments.
- 24 November 2020
- Published by Royal Society of Chemistry (RSC) in Molecular Systems Design & Engineering
- Vol. 6 (2) , 122-131
Quantitative prediction of charge regulation in oligopeptides
Charge regulation in the peptide Glu5–His5 as a model weak ampholyte: simulations predict deviations from the ideal ionization of free aminoacids, in quantitative agreement with experiments.
- 6 November 2019
- Published by Wiley in Electrophoresis
- Vol. 41 (7-8) , 493-501
Determination of thermodynamic acidity constants and limiting ionic mobilities of weak electrolytes by capillary electrophoresis using a new free software AnglerFish
Thermodynamic acidity constants (acid or acid-base dissociation constants, sometimes called also as ionization constants) and limiting ionic mobilities (both of them at defined temperature, usually 25 degrees C) are the fundamental physicochemical characteristics of a weak electrolyte, that is, weak acid or weak base or ampholyte. We introduce a novel method for determining the data of a weak electrolyte by the nonlinear regression of effective electrophoretic mobility versus buffer composition dependence when measured in a set of BGEs with various pH. To correct the experimental data for zero ionic strength we use the extended Debye-Huckel model and Onsager-Fuoss law with no simplifications. Contrary to contemporary approaches, the nonlinear regression is performed on limiting mobility data calculated by PeakMaster's correction engine, not on the raw experimental mobility data. Therefore, there is no requirement to perform all measurements at a constant ionic strength of the set of BGEs. We devised the computer program AnglerFish that performs the necessary calculations in a user-friendly fashion. All thermodynamic pKa values and limiting electrophoretic mobilities for arbitrarily charged substances having any number of ionic forms are calculated by one fit. The user input consists of the buffer composition of the set of BGEs and experimentally measured effective mobilities of the inspected weak electrolyte.
- 6 November 2019
- Published by Wiley in Electrophoresis
- Vol. 41 (7-8) , 493-501
Determination of thermodynamic acidity constants and limiting ionic mobilities of weak electrolytes by capillary electrophoresis using a new free software AnglerFish
Thermodynamic acidity constants (acid or acid-base dissociation constants, sometimes called also as ionization constants) and limiting ionic mobilities (both of them at defined temperature, usually 25 degrees C) are the fundamental physicochemical characteristics of a weak electrolyte, that is, weak acid or weak base or ampholyte. We introduce a novel method for determining the data of a weak electrolyte by the nonlinear regression of effective electrophoretic mobility versus buffer composition dependence when measured in a set of BGEs with various pH. To correct the experimental data for zero ionic strength we use the extended Debye-Huckel model and Onsager-Fuoss law with no simplifications. Contrary to contemporary approaches, the nonlinear regression is performed on limiting mobility data calculated by PeakMaster's correction engine, not on the raw experimental mobility data. Therefore, there is no requirement to perform all measurements at a constant ionic strength of the set of BGEs. We devised the computer program AnglerFish that performs the necessary calculations in a user-friendly fashion. All thermodynamic pKa values and limiting electrophoretic mobilities for arbitrarily charged substances having any number of ionic forms are calculated by one fit. The user input consists of the buffer composition of the set of BGEs and experimentally measured effective mobilities of the inspected weak electrolyte.
- 1 November 2019
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1085, 126-135
Online preconcentration of weak electrolytes at the pH boundary induced by a system zone in capillary zone electrophoresis
- 1 November 2019
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1085, 126-135
Online preconcentration of weak electrolytes at the pH boundary induced by a system zone in capillary zone electrophoresis
- 8 March 2018
- Published by Wiley in Electrophoresis
- Vol. 39 (11) , 1390-1398
Enhancement of the conductivity detection signal in capillary electrophoresis systems using neutral cyclodextrins as sweeping agents
Conductivity detection is a universal detection technique often encountered in electrophoretic separation systems, especially in modern chip‐electrophoresis based devices. On the other hand, it is sparsely combined with another contemporary trend of enhancing limits of detection by means of various preconcentration strategies. This can be attributed to the fact that a preconcentration experimental setup usually brings about disturbances in a conductivity baseline. Sweeping with a neutral sweeping agent seems a good candidate for overcoming this problem. A neutral sweeping agent does not hinder the conductivity detection while a charged analyte may preconcentrate on its boundary due to a decrease in its effective mobility. This study investigates such sweeping systems theoretically, by means of computer simulations, and experimentally. A formula is provided for the reliable estimation of the preconcentration factor. Additionally, it is demonstrated that the conductivity signal can significantly benefit from slowing down the analyte and thus the overall signal enhancement can easily overweight amplification caused solely by the sweeping process. The overall enhancement factor can be deduced a priori from the linearized theory of electrophoresis implemented in the PeakMaster freeware. Sweeping by neutral cyclodextrin is demonstrated on an amplification of a conductivity signal of flurbiprofen in a real drug sample. Finally, a possible formation of unexpected system peaks in systems with a neutral sweeping agent is revealed by the computer simulation and confirmed experimentally.
- 8 March 2018
- Published by Wiley in Electrophoresis
- Vol. 39 (11) , 1390-1398
Enhancement of the conductivity detection signal in capillary electrophoresis systems using neutral cyclodextrins as sweeping agents
Conductivity detection is a universal detection technique often encountered in electrophoretic separation systems, especially in modern chip‐electrophoresis based devices. On the other hand, it is sparsely combined with another contemporary trend of enhancing limits of detection by means of various preconcentration strategies. This can be attributed to the fact that a preconcentration experimental setup usually brings about disturbances in a conductivity baseline. Sweeping with a neutral sweeping agent seems a good candidate for overcoming this problem. A neutral sweeping agent does not hinder the conductivity detection while a charged analyte may preconcentrate on its boundary due to a decrease in its effective mobility. This study investigates such sweeping systems theoretically, by means of computer simulations, and experimentally. A formula is provided for the reliable estimation of the preconcentration factor. Additionally, it is demonstrated that the conductivity signal can significantly benefit from slowing down the analyte and thus the overall signal enhancement can easily overweight amplification caused solely by the sweeping process. The overall enhancement factor can be deduced a priori from the linearized theory of electrophoresis implemented in the PeakMaster freeware. Sweeping by neutral cyclodextrin is demonstrated on an amplification of a conductivity signal of flurbiprofen in a real drug sample. Finally, a possible formation of unexpected system peaks in systems with a neutral sweeping agent is revealed by the computer simulation and confirmed experimentally.
- 4 August 2017
- Published by Springer Nature in Chemical Papers
- Vol. 72 (1) , 139-147
The effect of buffer concentration and cation type in the mobile phase on retention of amino acids and dipeptides in hydrophilic interaction liquid chromatography
- 4 August 2017
- Published by Springer Nature in Chemical Papers
- Vol. 72 (1) , 139-147
The effect of buffer concentration and cation type in the mobile phase on retention of amino acids and dipeptides in hydrophilic interaction liquid chromatography