Claudio Fania has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Accuracy of the KOROT P3 Accurate automated auscultatory blood pressure measuring device for professional use in people with extra-large arms

    by Claudio Fania, Antonella Giletto, Alice Niero, Paolo Palatini

    Objective: To determine the accuracy of the KOROT P3 Accurate (previously InBody BPBIO480KV) monitor, an automated auscultatory blood pressure (BP) measuring device developed for professional use, in people with extra-large arms according to the ISO81060-2 2018 protocol. Methods: The KOROT P3 Accurate was tested in 37 subjects with upper-arm circumference ranging from >42 to 53 cm using a mercury sphygmomanometer coupled to a 20 × 40 cm tronco-conical cuff as the reference standard. Results: The mean BP difference between the device and the observers’ reference measurements was 1.2 ± 2.0 mmHg for systolic BP and 1.0 ± 2.0 mmHg for diastolic BP. These data were in agreement with criterion 1 of the protocol standard requirements (≤5 ± 8 mmHg). Also criterion 2 was satisfied being the standard deviations ± 1.7 mmHg for systolic BP and ± 1.6 for diastolic BP, well below the maximum values required by the protocol (±6.84/6.87 mmHg). Scatterplots of device-reference systolic and diastolic BP differences showed similar accuracy across the range of participants’ BP, arm circumference and upper-arm slant angle. Conclusions: These data show that the KOROT P3 Accurate monitor satisfied the ISO 81060-2:2018 standard requirements in a special population of people with extra-large arms ranging from >42 to 53 cm.


  • Open Access

    OVERWEIGHT OR OBESITY DOES NOT CARRY AN INCREASED RISK OF ADVERSE OUTCOME IN YOUNG TO MIDDLE AGE PEOPLE WITHOUT METABOLIC ABNORMALITIES

    by Paolo Palatini, Francesca Saladini, Lucio Mos, Claudio Fania, Francesca Battista, Andrea Ermolao, Guido Garavelli, Marcello Rattazzi

    Objective: Overweight or obesity (OvOb) is a risk factor for the development of cardiometabolic complications. However, according to some investigators, OvOb developed without hypertension and insulin resistance may be considered as a benign phenotype. The aim of the present study was to investigate the prognostic significance of OvOb (BMI> = 25 kg/m2) without concomitant metabolic abnormalities in young-to-middle-age subjects screened for stage 1 hypertension. Design and method: We examined 1208, 18-to-45-year-old participants from the HARVEST study. Mean age was 33.1 ± 8.6 years and BP 145.5 ± 10.6/93.5 ± 5.7 mmHg. Participants were classified into four groups according to whether they had OvOb or not (0/1) and had normal (group 0) or at least one abnormal (group 1) metabolic syndrome parameter (glucose, triglyceride, HDL-cholesterol, and average 24-hour BP). The predictive role of OvOb/metabolic group for incident hypertension and cardiovascular or renal events (MACE) was evaluated in Cox survival analyses, adjusting for other risk factors and several confounders. Results: ObOv was present in 51.1% of the participants and at least one metabolic abnormality was present in 74.5%. Among the subjects with OvOb, 20.2% had no metabolic abnormalities, 40.5% had one metabolic abnormality, and 39.3% had two or more metabolic abnormalities. During a median follow-up of 17.4 years, 80.6% of the participants developed hypertension requiring pharmacological treatment and 8.9% had a MACE. In adjusted Cox models, OvOb participants with at least one metabolic abnormality had an increased risk of incident hypertension (HR, 1.43; 95%CI,1.12 - 1.81, p = 0.003) and MACE (2.34,1.03 - 5.36, p = 0.043) compared to those with normal metabolic parameters. Among the participants with normal BMI, a similar metabolic-related increase in risk was found for the hypertension outcome (HR, 1.52;95%CI,1.21 - 1.92, p = 0.0003), but not for MACE (1.64,0.70 - 3.81, p = 0.25). In a Cox model in the whole population, when controlled for each other the metabolic group (0/1) was a predictor of hypertension (p < 0.0001) and MACE (p = 0.028) whereas the ObOv group was not (p>0.05). Conclusions: These data show that in young-to-middle-age people, an abnormal metabolic profile is an important predictor of future hypertension needing treatment and MACE. OvOb without metabolic abnormalities does not carry an increased risk of adverse outcomes.

  • Open Access

    Reproducibility and Predictive Value of White-Coat Hypertension in Young to Middle-Age Subjects

    by Paolo Palatini, Lucio Mos, Francesca Saladini, Olga Vriz, Claudio Fania, Andrea Ermolao, Francesca Battista, Marcello Rattazzi

    (1) Aim. The aim of the study was to investigate the reproducibility of white-coat hypertension (WCH) and its predictive capacity for hypertension needing antihypertensive treatment (HT) in young to middle-age subjects. (2) Methods. We investigated 1096 subjects from the HARVEST. Office and 24 h blood pressures (BP) were measured at baseline and after 3 months. The reproducibility of WCH was evaluated with kappa statistics. The predictive capacity of WCH was tested in multivariate Cox models (N = 1050). (3) Results. Baseline WCH was confirmed at 3-month assessment in 33.3% of participants. Reproducibility was fair (0.27, 95%CI 0.20–0.37) for WCH, poor (0.14, 95%CI 0.09–0.19) for office hypertension, and moderate (0.47, 95%CI 0.41–0.53) for ambulatory hypertension. WCH assessed either at baseline or after 3 months (unstable WCH) was not a significant predictor of HT during 17.4 years of follow-up. However, participants who had WCH both at baseline and after 3 months (stable WCH) had an increased risk of HT compared to the normotensives (Hazard ratio, 1.50, 95%CI 1.06–2.1). (4) Conclusions. These results show that WCH has limited reproducibility. WCH diagnosed with two BP assessments but not with one showed an increased risk of future HT. Our data indicate that WCH should be identified with two sets of office and ambulatory BP measurements.


  • Short-Term but not Long-Term Blood Pressure Variability Is a Predictor of Adverse Cardiovascular Outcomes in Young Untreated Hypertensives

    by Francesca Saladini, Claudio Fania, Lucio Mos, Olga Vriz, Andrea Mazzer, Paolo Spinella, Guido Garavelli, Andrea Ermolao, Marcello Rattazzi, Paolo Palatini

    Background: Whether blood pressure variability (BPV) measured with ambulatory monitoring (short-term BPV) or computed from office visits (long-term BPV) are related to each other and carry similar prognostic information is not well known. We investigated the independent determinants of short-term and long-term BPVs and their predictive capacity for the development of major adverse cardiovascular and renal events (MACEs) in a cohort of young hypertensive participants. Methods: Long-term BPV was calculated as visit-to-visit SD and average real variability from office blood pressure (BP) measured during 7 visits, within 1 year. Short-term BPV was calculated as weighted 24-hour SD and coefficient of variation. Hazard ratios (HRs) for risk of MACE were computed from multivariable Cox regressions. Results: 1,167 participants were examined; mean age was 33.1 ± 8.5 years. Variables independently associated with 24-hour systolic SD were 24-hour systolic BP, low physical activity, smoking, baseline office pulse pressure, systolic BP dipping, and diastolic white coat effect, while those associated with long-term BPV were mean systolic BP, age, female gender, and baseline office heart rate. During a median follow-up of 17.4 years 75 MACEs occurred. In Cox analysis only short-term BPV resulted a significant predictor of MACE (HR, 1.31 (1.07–1.59); P = 0.0086), while no index of long-term BPV was independently associated with outcome. Conclusions: In young hypertensive subjects only short-term BPV resulted a significant predictor of MACE on top of traditional ambulatory BP monitoring parameters. Whether reduction of short-term BPV with therapy may reduce the cardiovascular risk independently from the effects on 24-hour BP is a matter for future research.


  • Accuracy of the WatchBP O3 device for ambulatory blood pressure monitoring according to the new criteria of the ISO81060-2 2018 protocol

    by Claudio Fania, Ilaria Lazzaretto, Umberto Fontana, Paolo Palatini

    Objective: The aim of the study was to determine the accuracy of the Microlife WatchBP O3 monitor for ambulatory blood pressure (BP) measurement according to the new ISO81060-2 2018 protocol. Methods: The WatchBP O3 was first tested in 97 subjects from the general population (mean age, 71.3 years; 48 men) using four cuffs of different sizes. In a second study, 36 subjects (mean age, 72.9 years; 18 men) underwent stress testing on a cycle ergometer in order to increase their heart rate by 15% or more. Results: In the general population, the mean device–observer difference was 1.3 ± 3.2 mmHg for systolic BP and was 0.7 ± 3.2 mmHg for diastolic BP. These data were in agreement with criterion 1 of the protocol standard requirements (≤5 ± 8 mmHg). Also, criterion 2 was satisfied being the SDs of the 97 participants well below the maximum values required by the protocol (6.82 and 6.90 mmHg, respectively). During the ambulatory monitoring study, the average heart rate increase was 20.3% (range 15.4–28.9%). The mean device–observer difference was 1.5 ± 2.8 mmHg for systolic BP and was 1.7 ± 2.6 mmHg for diastolic BP. Also, these data were in agreement with criterion 1 of the protocol. Conclusions: These data show that the Microlife WatchBP O3 monitor satisfied the ISO 81060-2:2018 standard requirements for a general population across a wide range of arm sizes and that also the protocol criteria for validation of devices intended for ambulatory BP monitoring were fulfilled.


  • Effect of the shape of the cuff on blood pressure measurement in people with large arms

    by Paolo Palatini, Elisabetta Benetti, Claudio Fania, Andrea Ermolao, Paolo Spinella, Francesca Battista, Andrea Gasperetti, Francesca Saladini

    Purpose: Previous data suggest that tronco-conical cuffs should be used for accurate blood pressure (BP) measurement in the obese. However, not only arm size but also its shape may affect the accuracy of BP measurement when a cylindrical cuff is used. Methods: In 197 subjects with arm circumference >32 cm, and 157 subjects with arm circumference ≤ 32 cm, the upper-arm was considered as formed from two truncated cones and the frustum slant angles of the proximal (upper angle) and distal (middle angle) truncated cones were measured. Five cylindrical and five tronco-conical cuffs of appropriate size in relation to arm circumference were used. Results: In the group with large arm, the upper slant angle was greater than the middle angle (86.5 ± 1.7° versus 84.7 ± 2.3°), whereas in the group with normal arm the two angles were similar. In the former group, the cylindrical cuff overestimated BP by 2.5 ± 5.4/1.7 ± 4.7 mmHg, whereas in the latter negligible between-cuff BP discrepancies were found. In the whole sample, BP discrepancies between the cylindrical and the tronco-conical cuffs correlated with both arm size and shape, considered as the difference between the upper and middle slant angles (all p < 0.0001). Among the participants with large arm, the between-cuff BP discrepancies increased progressively with increasing upper-middle angle difference (3.75 ± 0.38/2.78 ± 0.32 mmHg for the top tertile, p < 0.001/<0.001). Conclusions: These data indicate that in people with large upper arms, the tronco-conical shape of the arm is more pronounced on the lower than the upper half, a feature that amplifies the BP measurement error when cylindrical cuffs are used.


  • Short-term blood pressure variability outweighs average 24-h blood pressure in the prediction of cardiovascular events in hypertension of the young

    by Paolo Palatini, Francesca Saladini, Lucio Mos, Claudio Fania, Adriano Mazzer, Susanna Cozzio, Giuseppe Zanata, Guido Garavelli, Tiziano Biasion, Paolo Spinella, et al.

    The association of short-term blood pressure (BP) variability (BPV) with cardiovascular events (CVEs) is controversial. Aim of this study was to investigate whether BPV measured as weighted 24-h SD was associated with CVE in a prospective cohort study of young patients screened for stage 1 hypertension. We performed 24-h ambulatory BP monitoring in 1206 participants aged 33.1 ± 8.5 years, untreated at baseline examination. Participants were divided into two categories with low (<12.8 mmHg) or high (≥12.8 mmHg) SBPV. Hazard ratios for CVE associated with BPV expressed either as continuous or categorical variable were computed from multivariable Cox models. During 15.4 ± 7.4 years of follow-up there were 69 fatal and nonfatal CVE. In multivariable Cox models, high SBPV was an independent predictors of CVE [2.75 (1.65–4.58); P = 0.0001] and of coronary events [3.84 (2.01–7.35), P < 0.0001]. Inclusion in the model of development of hypertension requiring treatment during the follow-up, did not reduce the strength of the associations. Addition of SBPV to fully adjusted models had significant impact on risk reclassification and integrated discrimination (relative integrated discrimination improvement for BPV as continuous variable: 13.5%, P = 0.045, and for BPV as categorical variable: 26.6%, P = 0.001). When the coefficient of variation was used as BPV metric similar results were obtained. Of note, in all Cox models average 24-h BP was no longer an independent predictor of outcome after BPV was included. Short-term BPV adds to the risk stratification for cardiovascular events in young-to-middle-age patients screened for stage 1 hypertension over and above traditional 24-h ambulatory monitoring indexes.


  • Validation of the Hingmed WBP-02A device for ambulatory blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010

    by Claudio Fania, Leonardo Vezzù, Ilaria Lazzaretto, Paolo Palatini

    The objective of this study was to determine the accuracy of the Hingmed WBP-02A device for ambulatory blood pressure (BP) monitoring according to the International Protocol of the European Society of Hypertension (ESH-IP). Device evaluation was carried out in 33 patients. The mean age was 69.8±13.8 years, the mean systolic BP was 137.6±27.0 mmHg (range: 96–172), the mean diastolic BP was 86.7±20.1 mmHg (range: 48–124) and the mean arm circumference was 30.1±6.2 cm (range: 20–43). The protocol requirements were followed precisely. Four different cuffs, small, standard, large, and extra-large were used. The device comfortably passed all ESH-IP requirements, as 84 out of 99 device–observer systolic BP differences and 97 of 99 diastolic BP differences were within ±5 mmHg thereby fulfilling the standards of the protocol. Device–observer BP differences were unrelated to arm circumference. These data show that the Hingmed WBP-02A device for ambulatory BP monitoring met the requirements for validation by the ESH-IP and can be recommended for clinical use in the adult population.


  • Only troncoconical cuffs can provide accurate blood pressure measurements in people with severe obesity

    by Paolo Palatini, Elisabetta Benetti, Claudio Fania, Francesca Saladini

    Objective: Rectangular (cylindrical) cuffs and bladders are currently used for blood pressure (BP) measurement at the upper arm. However, large arms have a troncoconical shape, which make cylindrical cuffs potentially unsuitable. Aim of this study was to investigate the effect of the shape of the cuff on BP measurement in very obese participants. Methods: In 33 participants with upper arm mid-circumference at least 42 cm and 33 participants of control, cylindrical and troncoconical cuffs of appropriate size were compared. In addition, in the obese participants, the pressure transmitted to the arm under the cuffs was measured at five cuff pressure levels using a paper-thin pressure sensor. Results: In all obese participants, the upper arm shape was troncoconical (mean ± SD slant angle, 84.1 ± 1.4°). In this group, SBP and DBP differences between the troncoconical and the cylindrical cuff were −5.3 ± 4.0 and −3.0 ± 4.3 mmHg, respectively (P < 0.001/=0.01 versus controls). In the obese participants of the top BP quintile, the between-cuff SBP difference was −9.1 ± 5.1 mmHg. Arm slant angle was an independent predictor of the between-cuff SBP discrepancy (P = 0.003). When the cylindrical cuff was used, measurement with the pressure sensor showed a marked disagreement between the pressure in the cuff and the pressure transmitted to the arm (mean difference, −10.2 ± 5.2 mmHg) a difference, which increased with increasing level of the pressure pumped in the cuff. Conclusion: In very obese people, cylindrical cuffs overestimate BP chiefly in people with high SBP and thus only troncoconical cuffs should be used.


  • Clinical characteristics and risk of hypertension needing treatment in young patients with systolic hypertension identified with ambulatory monitoring

    by Paolo Palatini, Francesca Saladini, Lucio Mos, Claudio Fania, Adriano Mazzer, Edoardo Casiglia

    The clinical significance of isolated systolic hypertension (ISH) in youth is controversial. One main confounding factor is the strong white-coat effect often observed in ISH patients. The aim of this study was to investigate the risk of hypertension needing pharmacological treatment in ISH identified with ambulatory 24-h blood pressure (24-h BP). We examined 1206, 18–45-year-old participants from the Hypertension and Ambulatory Recording VEnetia STudy. Based on 24-h BP, 269 participants were normotensive, 209 had ISH, 277 had isolated diastolic hypertension, and 451 had systolic–diastolic hypertension. The predictive role of ISH for incident hypertension was evaluated in Cox survival analyses, adjusting for risk factors and confounders. ISH participants were more frequently young men active in sports, with lower heart rate and cholesterol. During a 6.9-year follow-up, 61.1% of participants developed hypertension. ISH participants had a nonsignificant increase in risk of hypertension compared with normotensive (reference group). In contrast, participants with diastolic hypertension (1.44; 1.13–1.85) or systolic–diastolic hypertension (2.04; 1.59–2.64) had a significant increase in risk. When the ISH participants were divided according to whether 24-h mean BP was normal (<97 mmHg) or high, ISH patients with normal mean BP had no increase in risk (1.01; 0.73–1.40), whereas those with high mean BP had a significant increase in risk (1.70; 1.16–2.49). These data obtained with ambulatory BP monitoring show that in ISH people younger than 45 years, only mean BP is a predictor of future hypertension needing treatment, whereas the ISH status per se does not necessarily imply an increase in risk.