Hamed Rasouli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hamed Rasouli has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Alagan Anpalagan
WiNCORE Laboratory, Ryerson University, Toronto M5B 2K3, Canada
6 shared publications- Alagan Anpalagan
Department of Electrical, Computer and Biomedical Engineering, Toronto Metropolitan University, Toronto, ON M5B 2K3, Canada
3 shared publications Gagik Badalians Gholikandi
2 shared publicationsHamed Dadkhah
Faculty of Engineering, Department of Civil Engineering, University of Mohaghegh Ardabili, Ardabil, Iran
2 shared publications- Mohtasham Mohebbi
Faculty of Engineering, University of Mohaghegh Ardabili, Ardabil, Iran
2 shared publications Ebrahim Ghaderi
1 shared publication
Latest Publications
- 1 December 2018
- Published by Elsevier in Biomass and Bioenergy
- Vol. 119, 75-89
Simultaneous effective sludge stabilization and direct electricity generation by merging microbial fuel cell (MFC) and Fered-Fenton reactor: An experimental study
- 1 December 2018
- Published by Elsevier in Biomass and Bioenergy
- Vol. 119, 75-89
Simultaneous effective sludge stabilization and direct electricity generation by merging microbial fuel cell (MFC) and Fered-Fenton reactor: An experimental study
- 23 March 2018
- Published by SAGE Publications in Journal of Vibration and Control
- Vol. 24 (23) , 5693-5704
Modified H2/LQG control algorithm for designing a multi-objective semi-active base isolation system
This paper proposes a modified version of H2/Linear Quadratic Gaussian (H2/LQG) control algorithm (MH2/LQG) to design effective semi-active base isolation systems with a supplemental magneto-rheological (MR) damper for simultaneously controlling the base drift and acceleration of a structure. In the proposed MH2/LQG control algorithm, the weighting parameter defined in the semi-active control law is considered variable during the seismic loading and is adjusted at each time step to prevent the device from applying excessive damping force to the structure. As a result, the supplemental control system is designed not only to reduce the base drift of the isolated structure but also to restrict increases that may occur in accelerations imparted to the superstructure due to excessive damping forces. As a numerical example to illustrate the proposed method, an isolated four-story structure is subjected to different earthquake records and the semi-active base isolation system is designed using both H2/LQG and MH2/LQG control algorithms. The results show the effectiveness of the proposed MH2/LQG control algorithm in designing semi-active base isolation systems which can provide a proper simultaneous control of the base drift and floor accelerations. In addition, comparing the performance of the MH2/LQG and multi-objective H2/LQG control algorithms shows that while the two design procedures work similarly in mitigating the maximum base drift, the MH2/LQG control algorithm is more effective in reducing the maximum floor acceleration.
- 23 March 2018
- Published by SAGE Publications in Journal of Vibration and Control
- Vol. 24 (23) , 5693-5704
Modified H2/LQG control algorithm for designing a multi-objective semi-active base isolation system
This paper proposes a modified version of H2/Linear Quadratic Gaussian (H2/LQG) control algorithm (MH2/LQG) to design effective semi-active base isolation systems with a supplemental magneto-rheological (MR) damper for simultaneously controlling the base drift and acceleration of a structure. In the proposed MH2/LQG control algorithm, the weighting parameter defined in the semi-active control law is considered variable during the seismic loading and is adjusted at each time step to prevent the device from applying excessive damping force to the structure. As a result, the supplemental control system is designed not only to reduce the base drift of the isolated structure but also to restrict increases that may occur in accelerations imparted to the superstructure due to excessive damping forces. As a numerical example to illustrate the proposed method, an isolated four-story structure is subjected to different earthquake records and the semi-active base isolation system is designed using both H2/LQG and MH2/LQG control algorithms. The results show the effectiveness of the proposed MH2/LQG control algorithm in designing semi-active base isolation systems which can provide a proper simultaneous control of the base drift and floor accelerations. In addition, comparing the performance of the MH2/LQG and multi-objective H2/LQG control algorithms shows that while the two design procedures work similarly in mitigating the maximum base drift, the MH2/LQG control algorithm is more effective in reducing the maximum floor acceleration.
- 9 October 2017
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 29 (7) , 1315-1332
A genetic algorithm–based design approach for smart base isolation systems
This article presents a new approach for designing effective smart base isolation systems composed of a low-damping linear base isolation and a semi-active magneto-rheological damper. The method is based on transforming the design procedure of the hybrid base isolation system into a constrained optimization problem. The magneto-rheological damper command voltages have been determined using H2/linear quadratic Gaussian and clipped-optimal control algorithms. Through a sensitivity analysis to identify the effective design parameters, base isolation and control algorithm parameters have been taken as design variables and optimally determined using genetic algorithm. To restrict increases in floor accelerations, the objective function of the optimization problem has been defined as minimizing the maximum base drift while putting specific constraint on the acceleration response. For illustration, the proposed method has been applied to design a semi-active hybrid isolation system for a four-story shear building under earthquake excitation. The results of numerical simulations show the effectiveness, simplicity, and capability of the proposed method. Furthermore, it has been shown that using the proposed method, the acceleration of the isolated structure can also be incorporated into design process and practically controlled with a slight sacrifice of control effectiveness in reducing the base drift.
- 9 October 2017
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 29 (7) , 1315-1332
A genetic algorithm–based design approach for smart base isolation systems
This article presents a new approach for designing effective smart base isolation systems composed of a low-damping linear base isolation and a semi-active magneto-rheological damper. The method is based on transforming the design procedure of the hybrid base isolation system into a constrained optimization problem. The magneto-rheological damper command voltages have been determined using H2/linear quadratic Gaussian and clipped-optimal control algorithms. Through a sensitivity analysis to identify the effective design parameters, base isolation and control algorithm parameters have been taken as design variables and optimally determined using genetic algorithm. To restrict increases in floor accelerations, the objective function of the optimization problem has been defined as minimizing the maximum base drift while putting specific constraint on the acceleration response. For illustration, the proposed method has been applied to design a semi-active hybrid isolation system for a four-story shear building under earthquake excitation. The results of numerical simulations show the effectiveness, simplicity, and capability of the proposed method. Furthermore, it has been shown that using the proposed method, the acceleration of the isolated structure can also be incorporated into design process and practically controlled with a slight sacrifice of control effectiveness in reducing the base drift.
- 1 October 2017
- Published by Elsevier in Process Safety and Environmental Protection
- Vol. 111, 627-634
Nitrate reduction using hybrid system consisting of zero valent magnesium powder/activated carbon (Mg0/AC) from water
- 1 October 2017
- Published by Elsevier in Process Safety and Environmental Protection
- Vol. 111, 627-634
Nitrate reduction using hybrid system consisting of zero valent magnesium powder/activated carbon (Mg0/AC) from water
- 1 February 2017
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 5 (1) , 1174-1185
Harvesting direct electricity from municipal waste-activated sludge simultaneous with its aerobic stabilization process: Investigation and optimization
- 1 February 2017
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 5 (1) , 1174-1185
Harvesting direct electricity from municipal waste-activated sludge simultaneous with its aerobic stabilization process: Investigation and optimization
- 27 February 2015
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 24 (4)
DGA-based approach for optimal design of active mass damper for nonlinear structures considering ground motion effect
This paper presents an effective method to design active mass dampers (AMDs) for mitigating the seismic response of nonlinear frames. The method is based on using the Newmark-based instantaneous optimal control algorithm for designing AMD, as well as using distributed genetic algorithm (DGA) for optimization of the active control system. To this end, an optimization problem has been defined which considers the parameters of the active control system as design variables and minimization of the maximum required control force of AMD as the objective function with some constraints defined on the maximum stroke length of AMD. Also, the effect of design excitation on performance of AMD under testing earthquakes has been studied. To assess the capabilities of the proposed method, a numerical example has been worked out where an AMD has been designed to control the response of an eight-story nonlinear shear building frame with hysteretic bilinear elasto–plastic behavior under white noise and real earthquake excitations. The designed control systems have been tested under a number of scaled and real earthquakes including both near and far-field earthquakes. Controller’s robustness against variations of structural parameters has also been assessed. The results of numerical simulations show the effectiveness, simplicity and capability of the proposed method in designing AMDs for nonlinear frames. Also comparing the performance of AMD system with that of passive tuned mass damper and active tendon control shows that the AMD has been more effective in reducing the seismic response of nonlinear frames under design and different testing earthquakes.
- 27 February 2015
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 24 (4)
DGA-based approach for optimal design of active mass damper for nonlinear structures considering ground motion effect
This paper presents an effective method to design active mass dampers (AMDs) for mitigating the seismic response of nonlinear frames. The method is based on using the Newmark-based instantaneous optimal control algorithm for designing AMD, as well as using distributed genetic algorithm (DGA) for optimization of the active control system. To this end, an optimization problem has been defined which considers the parameters of the active control system as design variables and minimization of the maximum required control force of AMD as the objective function with some constraints defined on the maximum stroke length of AMD. Also, the effect of design excitation on performance of AMD under testing earthquakes has been studied. To assess the capabilities of the proposed method, a numerical example has been worked out where an AMD has been designed to control the response of an eight-story nonlinear shear building frame with hysteretic bilinear elasto–plastic behavior under white noise and real earthquake excitations. The designed control systems have been tested under a number of scaled and real earthquakes including both near and far-field earthquakes. Controller’s robustness against variations of structural parameters has also been assessed. The results of numerical simulations show the effectiveness, simplicity and capability of the proposed method in designing AMDs for nonlinear frames. Also comparing the performance of AMD system with that of passive tuned mass damper and active tendon control shows that the AMD has been more effective in reducing the seismic response of nonlinear frames under design and different testing earthquakes.
- 19 August 2014
- Published by Springer Nature in Wireless Personal Communications
- Vol. 79 (3) , 2271-2290
Cooperative Subcarrier Allocation and Power Allocation in the Downlink of an Amplify-and-Forward OFDM Relaying System
- 19 August 2014
- Published by Springer Nature in Wireless Personal Communications
- Vol. 79 (3) , 2271-2290
Cooperative Subcarrier Allocation and Power Allocation in the Downlink of an Amplify-and-Forward OFDM Relaying System
- 1 January 2014
- Published by Inderscience Publishers in International Journal of Autonomous and Adaptive Communications Systems
- Vol. 7 (1/2) , 75-90
Performance of power allocation schemes in an amplify-and-forward single-relay system with diversity at destination
Different strategies can be followed to achieve efficient power allocation in wireless systems. While optimising the average received SNR would directly result in an optimised average BER and outage probability in a direct wireless communication link, it is not clear whether we can achieve an optimised average BER and/or outage probability in a relaying system by optimising the average received SNR. In this paper, the problem of power allocation in a single-relay amplify-and-forward wireless system with maximal ratio combining (MRC) at the destination terminal is investigated via optimising three different objective functions: average SNR, average BER and outage probability. The average SNR, average BER and outage probability expressions are first derived as a function of source and relay transmit powers and variance of the channel gains. Based on these expressions, closed-form expressions are derived for optimum transmit power allocation between source and relay. It is observed that the BER-based and outage-based power allocation schemes achieve performance improvement over the SNR-based scheme when the relay is closer to the source; however, all the three schemes perform equally when the relay is close to the destination.
- 1 January 2014
- Published by Inderscience Publishers in International Journal of Autonomous and Adaptive Communications Systems
- Vol. 7 (1/2) , 75-90
Performance of power allocation schemes in an amplify-and-forward single-relay system with diversity at destination
Different strategies can be followed to achieve efficient power allocation in wireless systems. While optimising the average received SNR would directly result in an optimised average BER and outage probability in a direct wireless communication link, it is not clear whether we can achieve an optimised average BER and/or outage probability in a relaying system by optimising the average received SNR. In this paper, the problem of power allocation in a single-relay amplify-and-forward wireless system with maximal ratio combining (MRC) at the destination terminal is investigated via optimising three different objective functions: average SNR, average BER and outage probability. The average SNR, average BER and outage probability expressions are first derived as a function of source and relay transmit powers and variance of the channel gains. Based on these expressions, closed-form expressions are derived for optimum transmit power allocation between source and relay. It is observed that the BER-based and outage-based power allocation schemes achieve performance improvement over the SNR-based scheme when the relay is closer to the source; however, all the three schemes perform equally when the relay is close to the destination.
- 1 January 2012
- Published by Springer Nature
- p. 46-57
Green Cooperative Transmission Scheme for Estimate-and-Forward Relay Based Wireless Communication Systems
- 1 January 2012
- Published by Springer Nature
- p. 46-57
Green Cooperative Transmission Scheme for Estimate-and-Forward Relay Based Wireless Communication Systems
- 1 July 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23766492,p. 749-753
Performance of power allocation schemes in a two-hop AF relay system with faded direct link
Though power allocation has been studied extensively in the literature, as energy efficiency becomes more important in “green” wireless communication, we revisit to study the differences in SNR vs BER-based power allocation (PA) for relay communication when the direct link is severely faded. The average SNR and average BER expressions are first derived for an amplify-and-forward relaying protocol with Rayleigh fading channels. Based on the derived expressions at the destination through two-hop communication, closed-form expressions for optimum transmit power are obtained at the source and the relay. It is observed that the higher the total transmit power is, the bigger portion of it should be allocated to the relay independent of its location. For a given end-to-end BER, optimally selected relay's location is relatively more closer to the source if BER-based PA is employed than that of the SNR-based PA. It is also noted that the BER-based power allocation scheme can achieve 1dB performance improvement over the SNR-based counterpart when relay is centrally located and is in the higher transmit power regime resulting in energy saving, for a two-hop wireless system with no avail of direct communication between transceivers.
- 1 July 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23766492,p. 749-753
Performance of power allocation schemes in a two-hop AF relay system with faded direct link
Though power allocation has been studied extensively in the literature, as energy efficiency becomes more important in “green” wireless communication, we revisit to study the differences in SNR vs BER-based power allocation (PA) for relay communication when the direct link is severely faded. The average SNR and average BER expressions are first derived for an amplify-and-forward relaying protocol with Rayleigh fading channels. Based on the derived expressions at the destination through two-hop communication, closed-form expressions for optimum transmit power are obtained at the source and the relay. It is observed that the higher the total transmit power is, the bigger portion of it should be allocated to the relay independent of its location. For a given end-to-end BER, optimally selected relay's location is relatively more closer to the source if BER-based PA is employed than that of the SNR-based PA. It is also noted that the BER-based power allocation scheme can achieve 1dB performance improvement over the SNR-based counterpart when relay is centrally located and is in the higher transmit power regime resulting in energy saving, for a two-hop wireless system with no avail of direct communication between transceivers.