Adrián Moisés García-Lara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Adrián Moisés García-Lara has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Fabian Equihua Guillen
Facultad de Ingeniería Mecánica y Eléctrica, Universidad Autónoma de Coahuila, Av. Barranquilla S/N, Col. Guadalupe, Monclova 25750, Mexico
5 shared publications C. Montero-Ocampo
CINVESTAV IPN Unidad Saltillo Carretera Saltillo, Monterrey Km 13, Apdo. Postal 663, C.P. 25000, 25903 Saltillo, COAH, Mexico
4 shared publications- Laura Guadalupe Castruita Avila
Facultad de Ingeniería Mecánica y Eléctrica, Universidad Autónoma de Coahuila, Barranquilla S/N, Guadalupe, Monclova 25720, Mexico
4 shared publications - Jesús Emilio Camporredondo Saucedo
Facultad de Ciencias Químicas, Universidad Autónoma de Coahuila, Blvd. Venustiano Carranza 935, República, Saltillo 25280, Mexico
3 shared publications J. E. Camporredondo-Saucedo
Facultad de Ingeniería Mecánica y Eléctrica, Universidad Autónoma de Coahuila, Avenida Barranquilla s/n, Colonia Guadalupe, C.P. 25750, 25760 Monclova, COAH, Mexico
2 shared publications- Odin Ramírez-Fernández
Research Department, Universidad Tecnológica de México (UNITEC México), Campus en Línea, Col. Anáhuac, Ciudad de México 11320, Mexico
2 shared publications
Latest Publications
- 8 May 2026
- Published by IOP Publishing in Biomedical Materials
- Vol. 21 (3)
Resource-efficient decellularization of human iliac arteries using a 3D-printed radial-flow bioreactor: CFD-guided design and experimental validation
Vascular bypass and reconstruction often rely on synthetic or allogeneic grafts, which may exhibit limited long-term patency and adverse host responses. Decellularized extracellular matrix (ECM) scaffolds offer a promising alternative; however, conventional perfusion protocols are frequently reagent-intensive and technically demanding. This study introduces a 3D-printed radial-flow bioreactor designed for the decellularization of human iliac arteries with reduced detergent consumption. Arteries were perfused radially for 8 days using a 1% w·v⁻¹ sodium dodecyl sulfate solution, followed by deoxyribonuclease I treatment and phosphate-buffered saline washes. Decellularization efficacy was quantified by nuclear density using 4′,6-diamidino-2-phenylindole staining, and residual DNA was measured by fluorometric quantification. The radial-flow bioreactor achieved approximately 97% nuclear reduction using 70 mL of detergent solution, compared to 250 mL required by a benchmark perfusion setup. Residual DNA content was reduced to 40 ± 5.2 ng·mg⁻¹, while collagen and elastin retention remained high. Computational fluid dynamics (CFD) revealed a uniform wall shear stress distribution along the luminal surface (mean wall shear stress ≈ 0.97 Pa) and a minimal pressure drop (ΔP ≈ 116 Pa) under simulated conditions. These findings provide a mechanistic rationale for the observed performance and support further device optimization. Overall, the proposed radial-flow bioreactor provides a resource-efficient and experimentally validated approach for human iliac artery decellularization.
- 8 May 2026
- Published by IOP Publishing in Biomedical Materials
- Vol. 21 (3)
Resource-efficient decellularization of human iliac arteries using a 3D-printed radial-flow bioreactor: CFD-guided design and experimental validation
Vascular bypass and reconstruction often rely on synthetic or allogeneic grafts, which may exhibit limited long-term patency and adverse host responses. Decellularized extracellular matrix (ECM) scaffolds offer a promising alternative; however, conventional perfusion protocols are frequently reagent-intensive and technically demanding. This study introduces a 3D-printed radial-flow bioreactor designed for the decellularization of human iliac arteries with reduced detergent consumption. Arteries were perfused radially for 8 days using a 1% w·v⁻¹ sodium dodecyl sulfate solution, followed by deoxyribonuclease I treatment and phosphate-buffered saline washes. Decellularization efficacy was quantified by nuclear density using 4′,6-diamidino-2-phenylindole staining, and residual DNA was measured by fluorometric quantification. The radial-flow bioreactor achieved approximately 97% nuclear reduction using 70 mL of detergent solution, compared to 250 mL required by a benchmark perfusion setup. Residual DNA content was reduced to 40 ± 5.2 ng·mg⁻¹, while collagen and elastin retention remained high. Computational fluid dynamics (CFD) revealed a uniform wall shear stress distribution along the luminal surface (mean wall shear stress ≈ 0.97 Pa) and a minimal pressure drop (ΔP ≈ 116 Pa) under simulated conditions. These findings provide a mechanistic rationale for the observed performance and support further device optimization. Overall, the proposed radial-flow bioreactor provides a resource-efficient and experimentally validated approach for human iliac artery decellularization.
- 16 September 2025
- Published by Elsevier in Engineering Analysis with Boundary Elements
- Vol. 180
Space–time meshfree finite pointset method for thermal problems with moving heat sources
- 16 September 2025
- Published by Elsevier in Engineering Analysis with Boundary Elements
- Vol. 180
Space–time meshfree finite pointset method for thermal problems with moving heat sources
- 10 July 2025
- Published by SAGE Publications in Technology and Health Care
Design and structural deformation assessment of three-dimensional printed dental implants by means of finite element analysis
Background: The increasing demand for dental implants necessitates the exploration of advanced materials and manufacturing techniques. Three-dimensional (3D) printing has emerged as a viable method for producing custom dental implants, allowing for intricate designs and improved patient-specific fits. This study focuses on the design and structural deformation assessment of 3D-printed dental implants using Finite Element Analysis (FEA). By simulating the mechanical behavior of these implants under realistic loading conditions, we aim to evaluate their performance and predict potential failure points, ultimately enhancing their reliability and longevity in clinical applications. Objective: The primary objective of this study is to conduct a comprehensive design and structural deformation assessment of three-dimensional (3D) printed dental implants using Finite Element Analysis (FEA). Specifically, the study aims to: Evaluate stress distribution and deformation patterns in three 3D-printed dental implant designs under simulated physiological loading. Compare the stiffness, strength, and elastic behavior of PEEK and CFR-PEEK under occlusal forces. Identify failure points in implants and bone–implant interfaces by analyzing high stress concentrations. Predict the biomechanical behavior of a novel dental implant by determining its elastic modulus through finite element analysis (FEA). Methods: Three models 3D were designed to understand stress distribution with different structures using PEEK as biomaterial, with 4 test conditions modeled and compared. An occlusal load was applied (230 N at 90˚ and 30˚) on the implants. Isotropic, linear elastic, and homogeneous were considerate as properties of the components. Results: Under axial loads, all models stayed within physiological stress limits, while under 30° oblique loading, Model 3 showed the lowest stress, strain, and pressure. Conclusions: FEA results indicate that 3D-printed dental implants, particularly the optimized Model 3, maintain safe stress levels under axial and oblique loads, supporting their potential for immediate loading. However, due to numerical limitations, experimental validation remains necessary to advance implant designs that optimize bone regeneration and material efficiency.
- 10 July 2025
- Published by SAGE Publications in Technology and Health Care
Design and structural deformation assessment of three-dimensional printed dental implants by means of finite element analysis
Background: The increasing demand for dental implants necessitates the exploration of advanced materials and manufacturing techniques. Three-dimensional (3D) printing has emerged as a viable method for producing custom dental implants, allowing for intricate designs and improved patient-specific fits. This study focuses on the design and structural deformation assessment of 3D-printed dental implants using Finite Element Analysis (FEA). By simulating the mechanical behavior of these implants under realistic loading conditions, we aim to evaluate their performance and predict potential failure points, ultimately enhancing their reliability and longevity in clinical applications. Objective: The primary objective of this study is to conduct a comprehensive design and structural deformation assessment of three-dimensional (3D) printed dental implants using Finite Element Analysis (FEA). Specifically, the study aims to: Evaluate stress distribution and deformation patterns in three 3D-printed dental implant designs under simulated physiological loading. Compare the stiffness, strength, and elastic behavior of PEEK and CFR-PEEK under occlusal forces. Identify failure points in implants and bone–implant interfaces by analyzing high stress concentrations. Predict the biomechanical behavior of a novel dental implant by determining its elastic modulus through finite element analysis (FEA). Methods: Three models 3D were designed to understand stress distribution with different structures using PEEK as biomaterial, with 4 test conditions modeled and compared. An occlusal load was applied (230 N at 90˚ and 30˚) on the implants. Isotropic, linear elastic, and homogeneous were considerate as properties of the components. Results: Under axial loads, all models stayed within physiological stress limits, while under 30° oblique loading, Model 3 showed the lowest stress, strain, and pressure. Conclusions: FEA results indicate that 3D-printed dental implants, particularly the optimized Model 3, maintain safe stress levels under axial and oblique loads, supporting their potential for immediate loading. However, due to numerical limitations, experimental validation remains necessary to advance implant designs that optimize bone regeneration and material efficiency.
- Open Access
- 1 January 2020
- Published by Universidad Francisco de Paula Santander in Respuestas
- Vol. 25 (1) , |84-194
Magnetorheological fluids: synthesis, properties and applications
The magnetorheological fluids have the ability to modify their viscosity quickly by subjecting it to a magnetic field, a quality that classifies them in the category of intelligent materials. Such fluids include three main components; the base fluid that is generally mineral or synthetic oil, magnetizable particles which are dispersed in the base fluid and the additives or stabilizers that prevent agglomeration and sedimentation of the particles, as well as the degradation induced by the carrier medium. The main challenge of these fluids is to maintain the rheological response to the magnetic field, as well as avoid the chemical and microstructural instability of the magnetoreological fluids. In the present investigation an exhaustive bibliographic review was carried out to understand the main aspects of these types of materials, their properties as well as the main applications in the different branches of industry and medicine. The most recent contributions focused on the chemical stability of magnetic particles through the application of surface coatings are discussed.
- 1 January 2020
- Published by Universidad Francisco de Paula Santander in Respuestas
- Vol. 25 (1) , |84-194
Open AccessMagnetorheological fluids: synthesis, properties and applications
The magnetorheological fluids have the ability to modify their viscosity quickly by subjecting it to a magnetic field, a quality that classifies them in the category of intelligent materials. Such fluids include three main components; the base fluid that is generally mineral or synthetic oil, magnetizable particles which are dispersed in the base fluid and the additives or stabilizers that prevent agglomeration and sedimentation of the particles, as well as the degradation induced by the carrier medium. The main challenge of these fluids is to maintain the rheological response to the magnetic field, as well as avoid the chemical and microstructural instability of the magnetoreological fluids. In the present investigation an exhaustive bibliographic review was carried out to understand the main aspects of these types of materials, their properties as well as the main applications in the different branches of industry and medicine. The most recent contributions focused on the chemical stability of magnetic particles through the application of surface coatings are discussed.
- Open Access
- 1 January 2014
- Published by Hindawi Limited in Journal of Chemistry
- Vol. 2014, 1-13
Arsenic Removal from Natural Groundwater by Electrocoagulation Using Response Surface Methodology
Contamination of natural groundwater by arsenic (As) is a serious problem that appears in some areas of Northern Central Mexico (NCM). In this research, As was removed from NCM wells groundwater by the electrocoagulation (EC) technique. Laboratory-scale arsenic electroremoval experiments were carried out at continuous flow rates between 0.25 and 1.00Lmin−1 using current densities of 5, 10, and 20Am−2. Experiments were performed under galvanostatic conditions during 5min, at constant temperature and pH. The response surface methodology (RSM) was used for the optimization of the processing variables (flow rate and current density), response modeling, and predictions. The highest arsenic removal efficiency from underground water (99%) was achieved at low flow rates (0.25Lmin−1) and high current densities (20Am−2). The response models developed explained 93.7% variability for As removal efficiency.
- 1 January 2014
- Published by Hindawi Limited in Journal of Chemistry
- Vol. 2014, 1-13
Open AccessArsenic Removal from Natural Groundwater by Electrocoagulation Using Response Surface Methodology
Contamination of natural groundwater by arsenic (As) is a serious problem that appears in some areas of Northern Central Mexico (NCM). In this research, As was removed from NCM wells groundwater by the electrocoagulation (EC) technique. Laboratory-scale arsenic electroremoval experiments were carried out at continuous flow rates between 0.25 and 1.00Lmin−1 using current densities of 5, 10, and 20Am−2. Experiments were performed under galvanostatic conditions during 5min, at constant temperature and pH. The response surface methodology (RSM) was used for the optimization of the processing variables (flow rate and current density), response modeling, and predictions. The highest arsenic removal efficiency from underground water (99%) was achieved at low flow rates (0.25Lmin−1) and high current densities (20Am−2). The response models developed explained 93.7% variability for As removal efficiency.
- 1 January 2014
- Published by Springer Nature in Journal of Iron and Steel Research International
- Vol. 21 (1) , 46-51
Development of Mathematical Model for Control Wear in Backup Roll for Hot Strip Mill
- 1 January 2014
- Published by Springer Nature in Journal of Iron and Steel Research International
- Vol. 21 (1) , 46-51
Development of Mathematical Model for Control Wear in Backup Roll for Hot Strip Mill
- 3 December 2013
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 23 (1) , 268-274
Simple Heat Treatment for Production of Hot-Dip Galvanized Dual Phase Steel Using Si-Al Steels
- 3 December 2013
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 23 (1) , 268-274
Simple Heat Treatment for Production of Hot-Dip Galvanized Dual Phase Steel Using Si-Al Steels
- 1 December 2009
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 172 (2-3) , 1617-1622
Energy and electrode consumption analysis of electrocoagulation for the removal of arsenic from underground water
- 1 December 2009
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 172 (2-3) , 1617-1622
Energy and electrode consumption analysis of electrocoagulation for the removal of arsenic from underground water
- 1 October 2009
- Published by IWA Publishing in Water Science & Technology
- Vol. 60 (8) , 2153-2160
An empirical model for treatment of arsenic contaminated underground water by electrocoagulation process employing a bipolar cell configuration with continuous flow
Arsenic (As) was removed electrochemically from underground water (GW) by electrocoagulation (EC) process employing a bipolar cell configuration with continuous flow using iron electrodes. A kinetic model derived from the Lagergren equation was applied to specify the kinetics of the arsenic removal reaction. Elucidation of the effect of the liquid flow rate on the treatment time and on the simulation results of the model was achieved. The results showed that treatment times decreased from 10.50 min to 0.75 min as the flow rate decreased from 3.500 to 0.875 L min−1 and the current density varied from 15 to 45 A m−2 respectively. The used sorption kinetic model successfully describes the arsenic removal by this process. The coefficients of determination were found to be very high in all cases (R2>0.99) indicating a good fit of the experimental data to Lagergren model.
- 1 October 2009
- Published by IWA Publishing in Water Science & Technology
- Vol. 60 (8) , 2153-2160
An empirical model for treatment of arsenic contaminated underground water by electrocoagulation process employing a bipolar cell configuration with continuous flow
Arsenic (As) was removed electrochemically from underground water (GW) by electrocoagulation (EC) process employing a bipolar cell configuration with continuous flow using iron electrodes. A kinetic model derived from the Lagergren equation was applied to specify the kinetics of the arsenic removal reaction. Elucidation of the effect of the liquid flow rate on the treatment time and on the simulation results of the model was achieved. The results showed that treatment times decreased from 10.50 min to 0.75 min as the flow rate decreased from 3.500 to 0.875 L min−1 and the current density varied from 15 to 45 A m−2 respectively. The used sorption kinetic model successfully describes the arsenic removal by this process. The coefficients of determination were found to be very high in all cases (R2>0.99) indicating a good fit of the experimental data to Lagergren model.
- 9 May 2009
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 205 (1-4) , 237-244
Improvement of Arsenic Electro-Removal from Underground Water by Lowering the Interference of other Ions
- 9 May 2009
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 205 (1-4) , 237-244
Improvement of Arsenic Electro-Removal from Underground Water by Lowering the Interference of other Ions