Ionel Ciucanu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ionel Ciucanu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Adrian Chiriac
Department of Chemistry, West University of Timisoara, Strada Pestalozzi 16, RO-1900 Timisoara, Romania, Department of Organic Chemistry, University of Agriculture Sciences, Calea Aradului 118, RO-1900 Timisoara, Romania, and Ecole des Mines d'Albi, Campus Jarlard, F 81013 Albi Cedex 09, France
3 shared publicationsAdrian Caprita
Department of Chemistry, West University of Timisoara, Strada Pestalozzi 16, RO-1900 Timisoara, Romania, Department of Organic Chemistry, University of Agriculture Sciences, Calea Aradului 118, RO-1900 Timisoara, Romania, and Ecole des Mines d'Albi, Campus Jarlard, F 81013 Albi Cedex 09, France
2 shared publications- Catherine E. Costello
Center for Biomedical Mass Spectrometry, Boston University, Boston, MA, United States of America
1 shared publication - Cristian Ionuţ Ciucanu
Faculty of Medicine, University of Medicine and Pharmacy “Victor Babes” of Timişoara, Timişoara, Romania
1 shared publication Francisc Kerek
1 shared publicationGheorghe Dehelean
“Vasile Goldis” Western University of Arad
1 shared publication
Latest Publications
- Open Access
- 4 September 2025
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 49 (21) , 6162-6167
Rapid and Esthetic Wound Healing in Surgery by Applying a Powdered Mixture of Mannose and Calcium Propionate
Background: Wound healing is a current problem in surgery. Wounds most commonly occur from surgery, accidents, and burns. The purpose of this study was to reduce bleeding time and wound healing time as well as prevent or mitigate scarring by applying D-mannose with calcium propionate mixtures directly to the wound in powder form. Methods: This study was a placebo, randomized, double-blind, crossover experiment involving a single group of twenty-five subjects. The number of incisions made was equal to the number of treatments required. Each subject had one incision per day. Only one treatment was applied to each wound. By the end, each subject was treated with all test mixtures and the placebo substance. Results: The results show that the bleeding time can be reduced to about 50% compared to D-mannose when treating the wound with a mixture containing 20-60 moles of D-mannose per 1 mole of powdered calcium propionate. The wound healing time was reduced by about 40% compared to D-mannose. No visible scarring was observed after 40 days on skin treated with the mannose and calcium propionate mixture. Conclusions: Bleeding time can be reduced by approximately 50% when the wound is treated with a mixture containing 40 moles of D-mannose per 1 mole of calcium propionate and wound healing time by approximately 40% compared to D-mannose. Both substances contribute to the destruction of pathogens and to the processes of new tissue formation, which accelerates the healing process. Treatment with this powdered mixture prevents skin scarring. Level of Evidence I: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
- 4 September 2025
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 49 (21) , 6162-6167
Open AccessRapid and Esthetic Wound Healing in Surgery by Applying a Powdered Mixture of Mannose and Calcium Propionate
Background: Wound healing is a current problem in surgery. Wounds most commonly occur from surgery, accidents, and burns. The purpose of this study was to reduce bleeding time and wound healing time as well as prevent or mitigate scarring by applying D-mannose with calcium propionate mixtures directly to the wound in powder form. Methods: This study was a placebo, randomized, double-blind, crossover experiment involving a single group of twenty-five subjects. The number of incisions made was equal to the number of treatments required. Each subject had one incision per day. Only one treatment was applied to each wound. By the end, each subject was treated with all test mixtures and the placebo substance. Results: The results show that the bleeding time can be reduced to about 50% compared to D-mannose when treating the wound with a mixture containing 20-60 moles of D-mannose per 1 mole of powdered calcium propionate. The wound healing time was reduced by about 40% compared to D-mannose. No visible scarring was observed after 40 days on skin treated with the mannose and calcium propionate mixture. Conclusions: Bleeding time can be reduced by approximately 50% when the wound is treated with a mixture containing 40 moles of D-mannose per 1 mole of calcium propionate and wound healing time by approximately 40% compared to D-mannose. Both substances contribute to the destruction of pathogens and to the processes of new tissue formation, which accelerates the healing process. Treatment with this powdered mixture prevents skin scarring. Level of Evidence I: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
- 11 June 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (16) , 6571-6576
Droplets-based microextraction assisted SPME for GC-MS analysis of polar compounds such as clopyralid in water
The performance of liquid phase microextraction with droplets of organic solvent that assists solid phase microextraction with fiber was assessed for GC-MS analysis of polar compounds in water.
- 11 June 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (16) , 6571-6576
Droplets-based microextraction assisted SPME for GC-MS analysis of polar compounds such as clopyralid in water
The performance of liquid phase microextraction with droplets of organic solvent that assists solid phase microextraction with fiber was assessed for GC-MS analysis of polar compounds in water.
- 4 July 2012
- Published by Wiley in Journal of Separation Science
- Vol. 35 (13) , 1651-1658
Solid phase microextraction assisted by droplets‐based liquid–liquid microextraction for analysis of volatile aromatic hydrocarbons in water by gas chromatography
A new technique for the analysis of volatile aromatic hydrocarbons by combining liquid–liquid microextraction with solid phase microextraction has been developed. The analytes were extracted from aqueous samples by an immobilized polydimethylsiloxane fiber assisted by the droplets of an appropriate organic solvent. Benzene, toluene, ethylbenzene, and o‐xylene were used as target analytes. The main factors potentially affecting the microextraction such as the nature and the volume of organic solvent, polydimethylsiloxane (PDMS) swelling, extraction time, agitation, temperature, and salts were optimized. The method requires a very low consumption of organic solvent. The relative enrichment factor is in the range of 7.1–32.4 for extraction in the presence of dichloromethane at an optimum volume of 18 μL mL−1 of aqueous sample. This enhancement over regular polydimethylsiloxane fiber is primarily the result of the fiber swelling and of a stable thin layer of organic solvent attached to the surface of the PDMS fiber. The limit of detection ranges from 0.02 to 0.65 ng mL−1 for the target compounds using a 7‐μm bonded polydimethylsiloxane coating and a flame ionization detector. The validity of this method is demonstrated by the analysis of a real waste water sample.
- 4 July 2012
- Published by Wiley in Journal of Separation Science
- Vol. 35 (13) , 1651-1658
Solid phase microextraction assisted by droplets‐based liquid–liquid microextraction for analysis of volatile aromatic hydrocarbons in water by gas chromatography
A new technique for the analysis of volatile aromatic hydrocarbons by combining liquid–liquid microextraction with solid phase microextraction has been developed. The analytes were extracted from aqueous samples by an immobilized polydimethylsiloxane fiber assisted by the droplets of an appropriate organic solvent. Benzene, toluene, ethylbenzene, and o‐xylene were used as target analytes. The main factors potentially affecting the microextraction such as the nature and the volume of organic solvent, polydimethylsiloxane (PDMS) swelling, extraction time, agitation, temperature, and salts were optimized. The method requires a very low consumption of organic solvent. The relative enrichment factor is in the range of 7.1–32.4 for extraction in the presence of dichloromethane at an optimum volume of 18 μL mL−1 of aqueous sample. This enhancement over regular polydimethylsiloxane fiber is primarily the result of the fiber swelling and of a stable thin layer of organic solvent attached to the surface of the PDMS fiber. The limit of detection ranges from 0.02 to 0.65 ng mL−1 for the target compounds using a 7‐μm bonded polydimethylsiloxane coating and a flame ionization detector. The validity of this method is demonstrated by the analysis of a real waste water sample.
- 1 February 2007
- Published by Elsevier in Analytica Chimica Acta
- Vol. 585 (1) , 81-85
Per-O-methylation of neutral carbohydrates directly from aqueous samples for gas chromatography and mass spectrometry analysis
- 1 February 2007
- Published by Elsevier in Analytica Chimica Acta
- Vol. 585 (1) , 81-85
Per-O-methylation of neutral carbohydrates directly from aqueous samples for gas chromatography and mass spectrometry analysis
- 1 August 2006
- Published by Elsevier in Analytica Chimica Acta
- Vol. 576 (2) , 147-155
Per-O-methylation reaction for structural analysis of carbohydrates by mass spectrometry
- 1 August 2006
- Published by Elsevier in Analytica Chimica Acta
- Vol. 576 (2) , 147-155
Per-O-methylation reaction for structural analysis of carbohydrates by mass spectrometry
- 1 December 2003
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 125 (52) , 16213-16219
Elimination of Oxidative Degradation during the per-O-Methylation of Carbohydrates
The possible oxidative degradation mechanism occurring during the per-O-methylation of carbohydrates in dimethyl sulfoxide with methyl iodide in the presence of base is described. Evidence is presented that this process occurs only under anhydrous conditions when there is a long reaction time between the carbohydrate dissolved in dimethyl sulfoxide and methyl iodide, followed by reaction with the base. Under these specific conditions, the oxidative degradation of alditols, and cyclic carbohydrates, with and without a free hemiacetal group, is observed. The reaction between carbohydrate and methyl iodide in dimethyl sulfoxide can result in a complete oxidative degradation depending on the type of carbohydrate and the time of reaction. The oxidative degradation can be accelerated by replacing methyl iodide with dimethyl sulfate. Mass spectrometric identification of the degradation products of d-glucitol indicates simultaneous oxidation processes at all the hydroxyl groups, with site dependent rates of their reactivity. This oxidative process is not a characteristic of the methylation of carbohydrates in dimethyl sulfoxide with methyl iodide in the presence of solid sodium hydroxide and can be totally avoided by treating the carbohydrate with powdered sodium hydroxide before introduction of methyl iodide under nonanhydrous conditions, or by adding a trace of water in dimethyl sulfoxide before methyl iodide, or by using N,N-dimethylacetamide as the solvent. The degradation of the per-O-methylated carbohydrates in the liquid−liquid extraction process is also taken into account, and it is found that the degradation process can be avoid by neutralization of the base before extraction, by using benzene or tetrachloromethane as extraction solvent, and by drying the final organic extract.
- 1 December 2003
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 125 (52) , 16213-16219
Elimination of Oxidative Degradation during the per-O-Methylation of Carbohydrates
The possible oxidative degradation mechanism occurring during the per-O-methylation of carbohydrates in dimethyl sulfoxide with methyl iodide in the presence of base is described. Evidence is presented that this process occurs only under anhydrous conditions when there is a long reaction time between the carbohydrate dissolved in dimethyl sulfoxide and methyl iodide, followed by reaction with the base. Under these specific conditions, the oxidative degradation of alditols, and cyclic carbohydrates, with and without a free hemiacetal group, is observed. The reaction between carbohydrate and methyl iodide in dimethyl sulfoxide can result in a complete oxidative degradation depending on the type of carbohydrate and the time of reaction. The oxidative degradation can be accelerated by replacing methyl iodide with dimethyl sulfate. Mass spectrometric identification of the degradation products of d-glucitol indicates simultaneous oxidation processes at all the hydroxyl groups, with site dependent rates of their reactivity. This oxidative process is not a characteristic of the methylation of carbohydrates in dimethyl sulfoxide with methyl iodide in the presence of solid sodium hydroxide and can be totally avoided by treating the carbohydrate with powdered sodium hydroxide before introduction of methyl iodide under nonanhydrous conditions, or by adding a trace of water in dimethyl sulfoxide before methyl iodide, or by using N,N-dimethylacetamide as the solvent. The degradation of the per-O-methylated carbohydrates in the liquid−liquid extraction process is also taken into account, and it is found that the degradation process can be avoid by neutralization of the base before extraction, by using benzene or tetrachloromethane as extraction solvent, and by drying the final organic extract.
- 8 September 2003
- Published by Elsevier in Analytica Chimica Acta
- Vol. 491 (2) , 163-171
Membrane in tandem with a helical sorbent trap as continuous sampling technique of the polyvinyl chloride thermo-oxidative degradation products for their on-line gas chromatographic monitoring
- 8 September 2003
- Published by Elsevier in Analytica Chimica Acta
- Vol. 491 (2) , 163-171
Membrane in tandem with a helical sorbent trap as continuous sampling technique of the polyvinyl chloride thermo-oxidative degradation products for their on-line gas chromatographic monitoring
- 22 January 2003
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (4) , 736-741
Helical Sorbent Microtrap for Continuous Sampling by a Membrane and Trap Interface for On-Line Gas Chromatographic Monitoring of Volatile Organic Compounds
A helical sorbent microtrap consisting of a helical sorbent fixed inside a silicosteel capillary tube is presented. The main parameters that affect the safe sampling time of the helical sorbent microtrap in continuous sampling by a membrane and trap interface for on-line gas chromatographic monitoring of organic volatiles in gaseous samples are examined, taking into account the helical configuration of the sorbent, the presence of the membrane in system, and the properties of the analytes. Thermal desorption of analytes from the helical sorbent trap was also examined having regard to the influence of the turbulent flow generated by the helical sorbent in the heat transfer and the effect of thermal backward flow on the peak shape. The practical application of the helical sorbent microtrap in a membrane and trap interface was demonstrated by on-line gas chromatographic monitoring of four volatile organic compounds in the fume hood air and of volatile organic compounds from a diesel engine exhaust. The limit of detection was in the picogram per milliliter range, depending on the time of trapping and the parameters that affect the permeation through the membrane.
- 22 January 2003
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (4) , 736-741
Helical Sorbent Microtrap for Continuous Sampling by a Membrane and Trap Interface for On-Line Gas Chromatographic Monitoring of Volatile Organic Compounds
A helical sorbent microtrap consisting of a helical sorbent fixed inside a silicosteel capillary tube is presented. The main parameters that affect the safe sampling time of the helical sorbent microtrap in continuous sampling by a membrane and trap interface for on-line gas chromatographic monitoring of organic volatiles in gaseous samples are examined, taking into account the helical configuration of the sorbent, the presence of the membrane in system, and the properties of the analytes. Thermal desorption of analytes from the helical sorbent trap was also examined having regard to the influence of the turbulent flow generated by the helical sorbent in the heat transfer and the effect of thermal backward flow on the peak shape. The practical application of the helical sorbent microtrap in a membrane and trap interface was demonstrated by on-line gas chromatographic monitoring of four volatile organic compounds in the fume hood air and of volatile organic compounds from a diesel engine exhaust. The limit of detection was in the picogram per milliliter range, depending on the time of trapping and the parameters that affect the permeation through the membrane.
- 5 October 2002
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (21) , 5501-5506
Helical Sorbent for Fast Sorption and Desorption in Solid-Phase Microextraction-Gas Chromatographic Analysis
A new technique for solid-phase microextraction (SPME) of analytes using a helical solid sorbent followed by thermal desorption into a gas chromatographic injector is reported. The main factors that affect the mass transport of analytes in sorption and thermal desorption process using a poly(dimethylsiloxane) (PDMS) helical sorbent are described. The sorption and thermal desorption were achieved in a few seconds, being very close by the theoretical prediction. Both processes were very fast by the reduction of the thickness of boundary layer between sorbent and gaseous sample as a result of a turbulent rotational flow of the headspace air on the surface of sorbent, which is generated by the helical configuration of the sorbent. The thermal desorption was also reduced by improving heat transfer into a thin boundary layer and by increasing the temperature of the heat transporter (carrier gas). The sorption and desorption with PDMS helical sorbent were compared with those of the PDMS silica rod. The extraction time was as much as 15 times faster with the PDMS helical sorbent than with the PDMS silica rod. The desorption with the PDMS helical sorbent was very fast, giving narrow peaks without tailing and a high efficiency of separation in comparison with PDMS silica rod.
- 5 October 2002
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (21) , 5501-5506
Helical Sorbent for Fast Sorption and Desorption in Solid-Phase Microextraction-Gas Chromatographic Analysis
A new technique for solid-phase microextraction (SPME) of analytes using a helical solid sorbent followed by thermal desorption into a gas chromatographic injector is reported. The main factors that affect the mass transport of analytes in sorption and thermal desorption process using a poly(dimethylsiloxane) (PDMS) helical sorbent are described. The sorption and thermal desorption were achieved in a few seconds, being very close by the theoretical prediction. Both processes were very fast by the reduction of the thickness of boundary layer between sorbent and gaseous sample as a result of a turbulent rotational flow of the headspace air on the surface of sorbent, which is generated by the helical configuration of the sorbent. The thermal desorption was also reduced by improving heat transfer into a thin boundary layer and by increasing the temperature of the heat transporter (carrier gas). The sorption and desorption with PDMS helical sorbent were compared with those of the PDMS silica rod. The extraction time was as much as 15 times faster with the PDMS helical sorbent than with the PDMS silica rod. The desorption with the PDMS helical sorbent was very fast, giving narrow peaks without tailing and a high efficiency of separation in comparison with PDMS silica rod.
- 1 July 2002
- Published by Elsevier in Journal of Chromatography A
- Vol. 964 (1-2) , 1-9
Continuous permeation of analytes through a thin poly(dimethylsiloxane) membrane followed by sorbent trapping for their gas chromatographic monitoring
- 1 July 2002
- Published by Elsevier in Journal of Chromatography A
- Vol. 964 (1-2) , 1-9
Continuous permeation of analytes through a thin poly(dimethylsiloxane) membrane followed by sorbent trapping for their gas chromatographic monitoring