BABaqer A Alhabeeb

Baqer A Alhabeeb

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Baqer A Alhabeeb has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • C. C. Ngo

    California State University, Fullerton, CA

    2 shared publications
  • Abdalrazzaq Ajaj

    Department of Mechanical Engineering, College of Engineering, University of Kerbala, Kerbala, Iraq

    1 shared publication
  • Benoit Michel

    INSA Lyon, CNRS, CETHIL, UMR5008, 69621 Villeurbanne, France

    1 shared publication
  • H N Mohammed

    Department of Mechanical Engineering, College of Engineering, University of Kerbala, Kerbala, Iraq

    1 shared publication
  • Hayder N Mohammed

    Department of Mechanical Engineering / College of Engineering / University of Kerbala, Kerbala, Iraq

    1 shared publication
  • K Almusawi

    Department of Mechanical Engineering, College of Engineering, University of Kerbala, Kerbala, Iraq

    1 shared publication

Latest Publications

  • Open Access

    Comparative Assessment of Primary Nozzle Throat Design Methods for Two-phase Ejectors

    by B. Alhabeeb, B. Michel, R. Revellin

    Two-phase ejectors are a promising technology for improving the performance of direct expansion vapor compression refrigeration systems, particularly in transcritical applications. Extensive studies have been conducted on modeling, simulation, and experimental investigation of two-phase ejectors. Among the available approaches, zero-dimensional (0-D) models provide a valuable compromise between simplicity and predictive capability. They remain essential for preliminary ejector design, even when more advanced approaches such as one-dimensional (1-D) models or computational fluid dynamics (CFD), are used. However, significant uncertainty remains in the estimation of the two-phase speed of sound and the choking conditions at the primary nozzle throat, which strongly influences the predicted throat geometry. This study presents a comparative assessment of primary nozzle throat design methods used in two-phase ejector models. Thirteen approaches reported in the literature and a newly proposed method based solely on mass and energy conservation equations were evaluated against published experimental data in terms of throat diameter and throat pressure. The results reveal significant discrepancies among the different approaches, with deviations ranging from -12% to +574% for the throat diameter and from -73% to +21% for the throat pressure. In contrast, the proposed approach showed comparable stability under the tested conditions, predicting the throat diameter with deviations ranging from -8% to +15%, and the throat pressure with a deviation of +7%, respectively. Furthermore, the method consistently generates a convergent-divergent nozzle configuration over a wide range of operating conditions, including variations in primary and secondary pressures and primary nozzle efficiency using R1234yf and CO2 as working fluids

  • Open Access

    Thermal insulators based on abundant waste materials

    by B A Alhabeeb, H N Mohammed, S A Alhabeeb

    Any airconditioned zone must be thermally insulated from its surroundings to maintain the desired temperature. Thermal insulators thus play a significant role in reducing heat transfer between airconditioned areas and their surroundings to save energy. Thermal insulators are usually made from materials with low thermal conductivity, and to reduce the cost of such insulators, this study investigated the use of waste organic materials as thermal insulators. This study is the second part of a project that aims to achieve an optimised insulator from both the thermal and economic perspectives. To achieve this, the heat conductivity of five different samples made from hair, grass, date seed, and date palm fibre were examined. The all samples were made with industrial white glue as a binder. The heat flow method was employed to determine their thermal conductivity, with results that showed that all samples offered thermal resistance to heat transfer in the range 0.0530 to 0.1068 W/mK. The best thermal resistance was provided by the sample made from hair and fibres. The current study supports sustainability by encouraging the use of waste organic materials in thermal insulators.


  • Open Access

    Investigating New Thermal Insulators Based on Cheap Natural Organic and Waste Materials: Part 1

    by Baqer A Alhabeeb, Hayder N Mohammed

    Thermal insulation is a very important way to save energy in buildings or any other thermal application. For buildings, thermal insulation minimizes the heat transfer rate between a conditioning zone and its surroundings. For thermal applications, such as thermal storage tanks, it keeps heat or cold stored for later use. The current study is part of a project investigating thermal insulators made from cheap natural, organic and waste materials. The thermal conductivity of six different specimens of thermal insulator, made from used water cotton filter, chicken feather, walnut shell, sunflower seed husk, sawdust and ash, was measured experimentally. Industrial white glue was used as a binder to prepare the specimens. The sawdust and ash, of which the thermal conductivities are known, were chosen to validate the geometry of the specimens as well as the measurements of the testing device. The results showed that all types provide good thermal resistance performance. In particular, the insulator made from used water cotton filter was the best. It provided 0.0277 W/m k, which is a very practical value of the thermal conductivity in thermal insulation applications. This study will contribute significantly to sustainability by recycling wastes or using abundant natural and cheap materials in thermal insulators.


  • Open Access

    Experimental evaluation of coupled heat and mass transfer in geothermal water cooling tower

    by B A Alhabeeb, K Almusawi, Abdalrazzaq Ajaj

    This research aims to study for the first time the thermal behavior of counter flow cooling tower using low temperature groundwater source for air cooling in domestic and agriculture fields under Kerbala climate. The thermal behavior of both water and air was analyzed experimentally in term of their temperatures for different mass flow rates with one type of packing. The experiments were conducted between 27 April and 12 June 2017. During these five weeks, the outdoor temperature and the average borehole water temperature at depth of 9 m ranges were 28 °C to 42°C and 22 °C to 26°C respectively. The analyses have shown that the evaporative cooling tower used in the present study provides conditioned air in or very close to the comfortable levels. Also, the study has shown that the effectiveness of the evaporative cooling tower is basically affected by airstream velocity.


  • Numerical Study on Natural Convection From a Row of Heated Pipes Embedded in an Air-Filled Cavity

    by C. C. Ngo, B. A. Alhabeeb

    Heat transfer from a buried pipe has been a subject of great interest due to its many important engineering applications, which include the underground pipelines for oil and gas transport and the power cables. The problem considered in the present study has applications related to a radiant underfloor heating system in residence and industry. In the existing literature, heat transfer from a buried pipe has been considered for various heat transfer modes and configurations. For example, analytical solutions are readily available for heat conduction from one single cylindrical heat source or multiple heat sources, and the heat transfer results are often expressed in terms of the conduction shape factor. As for heat convection from an array of pipes, most of the existing studies have been focused on external crossflow with forced convection from a bundle of pipes with either aligned or staggered pipe arrangement. This area of research has received much attention due to its important industrial applications in the design of boilers and heat exchangers. On the other hand, studies involved natural convection from an array of pipes are relatively limited. The problem considered in the present study is related to the simulation of underfloor piping systems suspended in the joist space beneath the subfloor. Natural convective heat transfer from a row of horizontal heated pipes embedded in a closed cavity filled with air has been numerically examined in this study. A two-dimensional steady-state model has been developed using ANSYS Fluent for the numerical simulation. A parametric study has been performed to investigate the effects of pipe spacing, pipe depth and pipe temperature on the flow patterns and heat transfer rates. The heat transfer mechanism from the heated pipes to the top surface of the air-filled cavity is revealed through the plots of streamlines and isotherms. The present numerical model has been developed and validated using a parallel experimental study. From the radiant underfloor heating application perspective, the results showed that a radiant heating system with pipes embedded at a shallow burial depth and placed closer together resulted with a more desired surface temperature distribution.


  • Experimental Study on Radiant Floor Heating System

    by C. C. Ngo, B. A. Alhabeeb, M. Balestrieri

    Radiant floor heating systems have become popular due to their advantages over conventional heating systems in residential, commercial and industrial spaces. They are also used for snow and ice melting and turf conditioning applications. This paper presents a general study focuses on the design of radiant floor heating systems and investigates the effect of design parameters such as pipe spacing (ranging from 4 in. to 12 in.), pipe depth (ranging from 2.5 in. to 6.5 in.) and pipe temperature (45 °C, 65 °C and 85 °C) on the performance of radiant floor heating system embedded in different mediums (air, gravel and sand). The experimental results showed that a radiant heating system with pipes embedded at a shallow burial depth and placed closer together resulted with a more desired floor temperature distribution. The average floor temperature was also higher when the piping system was embedded in an air-filled space instead of a porous medium such as gravel or sand.