Qingze Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qingze Liu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Aiping Liu
University of Science and Technology of China
2 shared publications - Xu Zhang
School of Microelectronics, University of Science and Technology of China, Hefei, China
2 shared publications - Xun Chen
University of Science and Technology of China
2 shared publications - Ruobing Qian
Epilepsy Center, Department of Neurosurgery, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China
1 shared publication Xiang Chen
Department of Electronic Science and Technology, University of Science and Technology of China, Hefei 230027, China
1 shared publication- Xiang Chen
School of Microelectronics, University of Science and Technology of China, Hefei, Anhui 230002, P. R. China
1 shared publication
Latest Publications
- 3 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
Muscle Artifact Removal Toward Mobile SSVEP-Based BCI: A Comparative Study
Steady-state visual evoked potential (SSVEP) serves as one of the extensively utilized paradigms for brain–computer interface (BCI). SSVEP-based BCI has advantages of good classification accuracy, high information transfer rate (ITR), and little user training. However, there exist few studies investigating SSVEP-based BCI in the mobile situation, where electroencephalography (EEG) data are inevitably contaminated by muscle activities, and meanwhile, a limited number of channels are preferred. In this study, two major muscle artifact removal schemes are investigated in the dynamic scenario. One scheme adopts state-of-the-art blind source separation (BSS) methods without electromyogram (EMG) reference, while the other utilizes auxiliary EMG channels as a reference in the denoising process. To evaluate the performance of two schemes, we have tested them on real EEG data collected from ten subjects. The results demonstrate that, in the few-channel condition of SSVEP data, there are classification accuracy improvements of 9.93% for the canonical correlation analysis (CCA) indicator and 15.72% for the task-related component analysis (TRCA) indicator after processed by recursive least-squares (RLS) filtering with auxiliary EMG, and in the single-channel condition, there are classification accuracy improvements of 22.00% for the CCA indicator and 24.42% for the TRCA indicator after RLS filtering, averaged across all the subjects and data lengths. However, the BSS-based methods fail to improve the classification accuracies of SSVEP. Thus, it is of necessity to mount additional EMG channels for effective muscle activity suppression. This study provides an insightful suggestion for future real-life BCI applications.
- 3 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
Muscle Artifact Removal Toward Mobile SSVEP-Based BCI: A Comparative Study
Steady-state visual evoked potential (SSVEP) serves as one of the extensively utilized paradigms for brain–computer interface (BCI). SSVEP-based BCI has advantages of good classification accuracy, high information transfer rate (ITR), and little user training. However, there exist few studies investigating SSVEP-based BCI in the mobile situation, where electroencephalography (EEG) data are inevitably contaminated by muscle activities, and meanwhile, a limited number of channels are preferred. In this study, two major muscle artifact removal schemes are investigated in the dynamic scenario. One scheme adopts state-of-the-art blind source separation (BSS) methods without electromyogram (EMG) reference, while the other utilizes auxiliary EMG channels as a reference in the denoising process. To evaluate the performance of two schemes, we have tested them on real EEG data collected from ten subjects. The results demonstrate that, in the few-channel condition of SSVEP data, there are classification accuracy improvements of 9.93% for the canonical correlation analysis (CCA) indicator and 15.72% for the task-related component analysis (TRCA) indicator after processed by recursive least-squares (RLS) filtering with auxiliary EMG, and in the single-channel condition, there are classification accuracy improvements of 22.00% for the CCA indicator and 24.42% for the TRCA indicator after RLS filtering, averaged across all the subjects and data lengths. However, the BSS-based methods fail to improve the classification accuracies of SSVEP. Thus, it is of necessity to mount additional EMG channels for effective muscle activity suppression. This study provides an insightful suggestion for future real-life BCI applications.
- Open Access
- 31 December 2019
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2019, 1-13
Removal of EMG Artifacts from Multichannel EEG Signals Using Combined Singular Spectrum Analysis and Canonical Correlation Analysis
Electroencephalography (EEG) signals collected from human scalps are often polluted by diverse artifacts, for instance electromyogram (EMG), electrooculogram (EOG), and electrocardiogram (ECG) artifacts. Muscle artifacts are particularly difficult to eliminate among all kinds of artifacts due to their complexity. At present, several researchers have proved the superiority of combining single-channel decomposition algorithms with blind source separation (BSS) to make multichannel EEG recordings free from EMG contamination. In our study, we come up with a novel and valid method to accomplish muscle artifact removal from EEG by using the combination of singular spectrum analysis (SSA) and canonical correlation analysis (CCA), which is named as SSA-CCA. Unlike the traditional single-channel decomposition methods, for example, ensemble empirical mode decomposition (EEMD), SSA algorithm is a technique based on principles of multivariate statistics. Our proposed approach can take advantage of SSA as well as cross-channel information. The performance of SSA-CCA is evaluated on semisimulated and real data. The results demonstrate that this method outperforms the state-of-the-art technique, EEMD-CCA, and the classic technique, CCA, under multichannel circumstances.
- 31 December 2019
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2019, 1-13
Open AccessRemoval of EMG Artifacts from Multichannel EEG Signals Using Combined Singular Spectrum Analysis and Canonical Correlation Analysis
Electroencephalography (EEG) signals collected from human scalps are often polluted by diverse artifacts, for instance electromyogram (EMG), electrooculogram (EOG), and electrocardiogram (ECG) artifacts. Muscle artifacts are particularly difficult to eliminate among all kinds of artifacts due to their complexity. At present, several researchers have proved the superiority of combining single-channel decomposition algorithms with blind source separation (BSS) to make multichannel EEG recordings free from EMG contamination. In our study, we come up with a novel and valid method to accomplish muscle artifact removal from EEG by using the combination of singular spectrum analysis (SSA) and canonical correlation analysis (CCA), which is named as SSA-CCA. Unlike the traditional single-channel decomposition methods, for example, ensemble empirical mode decomposition (EEMD), SSA algorithm is a technique based on principles of multivariate statistics. Our proposed approach can take advantage of SSA as well as cross-channel information. The performance of SSA-CCA is evaluated on semisimulated and real data. The results demonstrate that this method outperforms the state-of-the-art technique, EEMD-CCA, and the classic technique, CCA, under multichannel circumstances.