Naru Yoneda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Naru Yoneda has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Osamu Matoba
Kobe University
22 shared publications - Takanori Nomura
Wakayama University
16 shared publications - Yusuke Saita
Wakayama University
11 shared publications - Manoj Kumar
Amity School of Physical Sciences, Amity University Punjab, Sector 82A, Mohali 140306, India
7 shared publications Osamu Matoba
6 shared publicationsYusuke Saita
Faculty of Systems Engineering, Wakayama University, 930 Sakaedani, Wakayama, 640-8510, Japan
6 shared publications
Latest Publications
- 23 October 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (22) , 41769
Depth estimation in fluorescence microscopy using degree of polarization
Accurate axial depth estimation in fluorescence microscopy remains challenging in non-interferometric systems due to weak signals and strong background noise. Here, we investigate the depth-dependent behavior of the degree of polarization (DOP) and demonstrate its applicability for axial localization under low signal-to-noise ratio conditions. By formulating a noise-aware model based on the cross-spectral density matrix that explicitly incorporates unpolarized background fluorescence and detector noise, we explain the experimentally observed degradation of DOP with defocus. Polarization-resolved fluorescence experiments show that the measured DOP exhibits a maximum near the geometrical focus and gradually decays toward zero at larger defocus distances. Based on a calibrated DOP–defocus relationship, reliable depth estimation of fluorescent beads is achieved without interferometric or phase-sensitive measurements. Furthermore, combining DOP information from multiple axial planes improves robustness and enables accurate depth reconstruction of multi-layer samples, showing improved depth-estimation accuracy over the representative comparison methods under the tested conditions
- 23 October 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (22) , 41769
Depth estimation in fluorescence microscopy using degree of polarization
Accurate axial depth estimation in fluorescence microscopy remains challenging in non-interferometric systems due to weak signals and strong background noise. Here, we investigate the depth-dependent behavior of the degree of polarization (DOP) and demonstrate its applicability for axial localization under low signal-to-noise ratio conditions. By formulating a noise-aware model based on the cross-spectral density matrix that explicitly incorporates unpolarized background fluorescence and detector noise, we explain the experimentally observed degradation of DOP with defocus. Polarization-resolved fluorescence experiments show that the measured DOP exhibits a maximum near the geometrical focus and gradually decays toward zero at larger defocus distances. Based on a calibrated DOP–defocus relationship, reliable depth estimation of fluorescent beads is achieved without interferometric or phase-sensitive measurements. Furthermore, combining DOP information from multiple axial planes improves robustness and enables accurate depth reconstruction of multi-layer samples, showing improved depth-estimation accuracy over the representative comparison methods under the tested conditions
- 24 September 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (20) , 37419
Experimental benchmarking of the incoherent transport of intensity equation using spatial axial shearing incoherent digital holography
This paper presents an experimental benchmarking framework for evaluating phase retrieval consistency between the transport of intensity equation (TIE) and spatial axial shearing–based Incoherent Digital Holography (IDH) in fluorescence imaging. While TIE provides a non-interferometric, intensity-based approach for phase retrieval, its quantitative reliability under incoherent imaging conditions remains insufficiently validated against coherence-based techniques. Using a unified switchable experimental platform that ensures identical imaging conditions, we directly compare phase distributions retrieved by TIE and IDH from the same fluorescent objects. The IDH system employs spatial axial shearing and four-step phase shifting to reconstruct the complex spatial coherence function, providing a coherence-guided benchmark for comparison. Experimental results demonstrate strong agreement in the spatial extent and curvature of the retrieved phase profiles, while statistical analysis further confirms good consistency between the two methods across multiple fluorescent bead measurements. Under paraxial propagation conditions (Fresnel number ( N F > 1), TIE reconstructions show close agreement with both IDH and the conventional fluorescence reference image, whereas coherence-guided IDH remains more robust at larger defocus distances. The proposed benchmarking framework provides an experimental basis for assessing the reliability and limitations of TIE-based phase retrieval in incoherent fluorescence imaging.
- 24 September 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (20) , 37419
Experimental benchmarking of the incoherent transport of intensity equation using spatial axial shearing incoherent digital holography
This paper presents an experimental benchmarking framework for evaluating phase retrieval consistency between the transport of intensity equation (TIE) and spatial axial shearing–based Incoherent Digital Holography (IDH) in fluorescence imaging. While TIE provides a non-interferometric, intensity-based approach for phase retrieval, its quantitative reliability under incoherent imaging conditions remains insufficiently validated against coherence-based techniques. Using a unified switchable experimental platform that ensures identical imaging conditions, we directly compare phase distributions retrieved by TIE and IDH from the same fluorescent objects. The IDH system employs spatial axial shearing and four-step phase shifting to reconstruct the complex spatial coherence function, providing a coherence-guided benchmark for comparison. Experimental results demonstrate strong agreement in the spatial extent and curvature of the retrieved phase profiles, while statistical analysis further confirms good consistency between the two methods across multiple fluorescent bead measurements. Under paraxial propagation conditions (Fresnel number ( N F > 1), TIE reconstructions show close agreement with both IDH and the conventional fluorescence reference image, whereas coherence-guided IDH remains more robust at larger defocus distances. The proposed benchmarking framework provides an experimental basis for assessing the reliability and limitations of TIE-based phase retrieval in incoherent fluorescence imaging.
- Open Access
- 12 August 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 204
Optimization of reconstructed image quality in 3D computational fluorescence microscopy with electrically tunable spatial axial shearing by complex coherence function
- 12 August 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 204
Open AccessOptimization of reconstructed image quality in 3D computational fluorescence microscopy with electrically tunable spatial axial shearing by complex coherence function
- 5 June 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (20) , 38501
Heterodyne Interferometric Sound-Field Imaging with Full-Field Lock-In Detection
Interference-based sound-field imaging techniques, such as digital holography, have a maximum measurable frequency limited by the frame rate of image sensors according to the sampling theorem. In this study, we propose heterodyne interferometric sound-field Imaging (HISI), which combines optical heterodyne interferometry with full-field lock-in detection to visualize high-frequency sound field beyond the Nyquist frequency. The principle is verified through both simulations and experiments, demonstrating that the sound fields can be reconstructed from a down-converted signal recorded at a frame rate one order of magnitude lower than the original frequency. The proposed HISI overcomes the conventional frequency limitations in sound-field recording and further extends the achievable measurement duration and field of view.
- 5 June 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (20) , 38501
Heterodyne Interferometric Sound-Field Imaging with Full-Field Lock-In Detection
Interference-based sound-field imaging techniques, such as digital holography, have a maximum measurable frequency limited by the frame rate of image sensors according to the sampling theorem. In this study, we propose heterodyne interferometric sound-field Imaging (HISI), which combines optical heterodyne interferometry with full-field lock-in detection to visualize high-frequency sound field beyond the Nyquist frequency. The principle is verified through both simulations and experiments, demonstrating that the sound fields can be reconstructed from a down-converted signal recorded at a frame rate one order of magnitude lower than the original frequency. The proposed HISI overcomes the conventional frequency limitations in sound-field recording and further extends the achievable measurement duration and field of view.
- Open Access
- 1 June 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (6)
Enhancing quantum imaging efficiency by BiBO crystal-based entangled light source
Quantum imaging utilizing entangled photon pairs takes advantage of their strong quantum correlations to surpass the limitations of classical imaging techniques in terms of spatial resolution and signal-to-noise ratio. However, due to the low brightness of entangled photon sources, an enormous number of intensity images (∼107) is required for imaging in previous studies in order to acquire images with a sufficient signal-to-noise ratio, posing a challenge for practical implementation. A BiBO crystal, known for its large nonlinear optical coefficient, is considered a promising high-brightness entangled photon source. However, its performance has not been quantitatively evaluated in the context of quantum imaging systems, particularly regarding its impact on imaging performance. Here, we investigate the potential of a BiBO crystal as a light source for high-efficiency quantum imaging by performing parallel intensity correlation measurements and implementing quantum image distillation as an example in comparison with a commonly used BBO crystal. The results demonstrate that the use of the BiBO crystal enables more efficient quantum imaging compared to the conventional BBO crystal.
- 1 June 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (6)
Open AccessEnhancing quantum imaging efficiency by BiBO crystal-based entangled light source
Quantum imaging utilizing entangled photon pairs takes advantage of their strong quantum correlations to surpass the limitations of classical imaging techniques in terms of spatial resolution and signal-to-noise ratio. However, due to the low brightness of entangled photon sources, an enormous number of intensity images (∼107) is required for imaging in previous studies in order to acquire images with a sufficient signal-to-noise ratio, posing a challenge for practical implementation. A BiBO crystal, known for its large nonlinear optical coefficient, is considered a promising high-brightness entangled photon source. However, its performance has not been quantitatively evaluated in the context of quantum imaging systems, particularly regarding its impact on imaging performance. Here, we investigate the potential of a BiBO crystal as a light source for high-efficiency quantum imaging by performing parallel intensity correlation measurements and implementing quantum image distillation as an example in comparison with a commonly used BBO crystal. The results demonstrate that the use of the BiBO crystal enables more efficient quantum imaging compared to the conventional BBO crystal.
- Open Access
Mesoscopic cortical activities associated with pupil-linked perceptions inferred via explainable machine learning
Pupil dilation reflects arousal-related neural processes and is closely linked to sensory perception, attention, and cognitive state, but the mesoscopic cortical dynamics that accompany stimulus-evoked dilation remain unclear. Here, we combined simultaneous pupillometry and wide-field Ca2+imaging in mice with explainable machine learning to identify cortical activity patterns predictive of pupil dilation. Cortical activity was recorded during hindpaw somatosensory stimulation, visual pattern change, and visual contextual stimulation using an visual oddball paradigm; spontaneous pupil dilation was additionally analyzed using a public resting-state dataset. To reduce multicollinearity in wide-field imaging signals, cortical activity was decomposed into independent components, which were used as inputs to recurrent neural network (RNN) decoders. Models reliably predicted sensory-evoked pupil dilation above shuffled-label controls when sessions with pre-existing pupil dilation were excluded, indicating that stimulus-evoked dilation was associated with distinct cortical activity patterns. Feature attribution using SHapley Additive exPlanations (SHAP) and spatial back-mapping revealed condition-dependent cortical signatures. Activity around the retrosplenial cortex and higher-order visual areas contributed to predictions during somatosensory and visual pattern stimulation, whereas secondary motor cortex activity was prominent during visual contextual stimulation. Spontaneous pupil dilation required lower-frequency cortical signals for decoding, suggesting partly distinct dynamics from sensory-evoked dilation. These findings demonstrate that explainable machine learning can extract candidate cortical activity patterns associated with pupil-linked arousal from high-dimensional wide-field Ca2+ imaging data. Because feature importance does not establish causality, the identified regions provide hypothesis-generating targets for future circuit manipulation studies.
Open AccessMesoscopic cortical activities associated with pupil-linked perceptions inferred via explainable machine learning
Pupil dilation reflects arousal-related neural processes and is closely linked to sensory perception, attention, and cognitive state, but the mesoscopic cortical dynamics that accompany stimulus-evoked dilation remain unclear. Here, we combined simultaneous pupillometry and wide-field Ca2+imaging in mice with explainable machine learning to identify cortical activity patterns predictive of pupil dilation. Cortical activity was recorded during hindpaw somatosensory stimulation, visual pattern change, and visual contextual stimulation using an visual oddball paradigm; spontaneous pupil dilation was additionally analyzed using a public resting-state dataset. To reduce multicollinearity in wide-field imaging signals, cortical activity was decomposed into independent components, which were used as inputs to recurrent neural network (RNN) decoders. Models reliably predicted sensory-evoked pupil dilation above shuffled-label controls when sessions with pre-existing pupil dilation were excluded, indicating that stimulus-evoked dilation was associated with distinct cortical activity patterns. Feature attribution using SHapley Additive exPlanations (SHAP) and spatial back-mapping revealed condition-dependent cortical signatures. Activity around the retrosplenial cortex and higher-order visual areas contributed to predictions during somatosensory and visual pattern stimulation, whereas secondary motor cortex activity was prominent during visual contextual stimulation. Spontaneous pupil dilation required lower-frequency cortical signals for decoding, suggesting partly distinct dynamics from sensory-evoked dilation. These findings demonstrate that explainable machine learning can extract candidate cortical activity patterns associated with pupil-linked arousal from high-dimensional wide-field Ca2+ imaging data. Because feature importance does not establish causality, the identified regions provide hypothesis-generating targets for future circuit manipulation studies.
- Open Access
- 28 April 2026
- Published by Elsevier in SSRN Electronic Journal
Optimization of Reconstructed Image Quality in 3D Computational Fluorescence Microscopy with Electrically Tunable Spatial Axial Shearing by Complex Coherence Function
We investigate the optimization of reconstructed image quality in a three-dimensional (3D) fluorescence microscopy system based on spatial axial shearing interferometry in incoherent digital holography (IDH), where the axial shear between orthogonal polarization components is electrically controlled using a liquid crystal lens (LCL). The electrically tunable LCL provides dynamic shear adjustment, improving system flexibility and alignment stability. Beyond hardware implementation, we introduce a coherence-guided IDH framework in which fringe visibility serves as a quantitative indicator of interference reliability and depth reconstruction fidelity. Experiments with fluorescent microspheres demonstrate a strong correlation between spatial coherence strength, signal-to-noise ratio, and 3D reconstruction performance. These results highlight the central role of spatial coherence in incoherent holographic fluorescence imaging and establish coherence-guided optimization as an effective strategy for robust and accurate 3D fluorescence reconstruction
- 28 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOptimization of Reconstructed Image Quality in 3D Computational Fluorescence Microscopy with Electrically Tunable Spatial Axial Shearing by Complex Coherence Function
We investigate the optimization of reconstructed image quality in a three-dimensional (3D) fluorescence microscopy system based on spatial axial shearing interferometry in incoherent digital holography (IDH), where the axial shear between orthogonal polarization components is electrically controlled using a liquid crystal lens (LCL). The electrically tunable LCL provides dynamic shear adjustment, improving system flexibility and alignment stability. Beyond hardware implementation, we introduce a coherence-guided IDH framework in which fringe visibility serves as a quantitative indicator of interference reliability and depth reconstruction fidelity. Experiments with fluorescent microspheres demonstrate a strong correlation between spatial coherence strength, signal-to-noise ratio, and 3D reconstruction performance. These results highlight the central role of spatial coherence in incoherent holographic fluorescence imaging and establish coherence-guided optimization as an effective strategy for robust and accurate 3D fluorescence reconstruction
- Open Access
- 30 March 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (2)
Quantitative polarization digital holographic microscope
Quantitative polarization digital holographic microscope (QPDHM) emerges as a powerful technique offering unprecedented capabilities in imaging and extraction of rich optical parameters, such as phase retardation, birefringence, and orientation of anisotropic structures, which are crucial for understanding biological processes and material properties at the microscale. In this work, a new configuration of single-shot common-path QPDHM with a very high temporal stability (of ~0.0096 rad.) is proposed and experimentally demonstrated. The system involves the polarization-angular multiplexing digital holographic method in which only a single multiplexed hologram is recorded, which provides the complex amplitudes of the object under study corresponding to the orthogonal polarization components. The full polarization state of the object light field, i.e., the Stokes parameters, is quantitatively measured from the obtained complex amplitude information. The system does not require mechanical movement of any optical components or complicated devices such as phase-shifting or polarization cameras. This advantage of the proposed system makes it a suitable candidate for the visualization and analysis of dynamic and fast transient polarization state measurements. The imaging performance and measurement accuracy of the proposed system are verified on several anisotropic materials, and the obtained results corroborate its relevance.
- 30 March 2026
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (2)
Open AccessQuantitative polarization digital holographic microscope
Quantitative polarization digital holographic microscope (QPDHM) emerges as a powerful technique offering unprecedented capabilities in imaging and extraction of rich optical parameters, such as phase retardation, birefringence, and orientation of anisotropic structures, which are crucial for understanding biological processes and material properties at the microscale. In this work, a new configuration of single-shot common-path QPDHM with a very high temporal stability (of ~0.0096 rad.) is proposed and experimentally demonstrated. The system involves the polarization-angular multiplexing digital holographic method in which only a single multiplexed hologram is recorded, which provides the complex amplitudes of the object under study corresponding to the orthogonal polarization components. The full polarization state of the object light field, i.e., the Stokes parameters, is quantitatively measured from the obtained complex amplitude information. The system does not require mechanical movement of any optical components or complicated devices such as phase-shifting or polarization cameras. This advantage of the proposed system makes it a suitable candidate for the visualization and analysis of dynamic and fast transient polarization state measurements. The imaging performance and measurement accuracy of the proposed system are verified on several anisotropic materials, and the obtained results corroborate its relevance.
- 1 January 2026
- Published by Optica Publishing Group
- p. W4A.1
Investigation of Speckle Design Methods for Super-Resolution Ghost Imaging
We design speckles to realize super-resolution ghost imaging by enforcing a target intensity probability density function and a target autocorrelation. Simulations show that the proposed speckles have narrowed autocorrelation compared with Rayleigh speckles.
- 1 January 2026
- Published by Optica Publishing Group
- p. W4A.1
Investigation of Speckle Design Methods for Super-Resolution Ghost Imaging
We design speckles to realize super-resolution ghost imaging by enforcing a target intensity probability density function and a target autocorrelation. Simulations show that the proposed speckles have narrowed autocorrelation compared with Rayleigh speckles.
- 16 November 2025
- Published by Springer Nature
- p. 131-132
Quantitative Phase Imaging Under Commercially Available Confocal Microscopy
- 16 November 2025
- Published by Springer Nature
- p. 131-132
Quantitative Phase Imaging Under Commercially Available Confocal Microscopy