Man-Shik Shim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Man-Shik Shim has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Boohwi Hong
Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, College of Medicine, Chungnam National University, Daejeon, Korea
2 shared publications - Soomin Lee
Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, College of Medicine, Chungnam National University, Daejeon, Korea
2 shared publications - Yoon-Hee Kim
Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, College of Medicine, Chungnam National University, Daejeon, Korea
2 shared publications - Boeun Kwon
Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, College of Medicine, Chungnam National University, Daejeon, Korea
1 shared publication - Chahyun Oh
Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, College of Medicine, Chungnam National University, Daejeon, Korea
1 shared publication - Chang Woo Choi
Department of Thoracic and Cardiovascular Surgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon, Korea
1 shared publication
Latest Publications
- Open Access
- 12 November 2026
- Published by The Korean Society of Anesthesiologists in Anesthesia and Pain Medicine
Intraoperative transesophageal echocardiography detection of a mobile echogenic structure at the left atriotomy suture line - A case report -
Background: Intraoperative transesophageal echocardiography (TEE) provides real-time anatomical and functional assessment during cardiac surgery and may detect abnormalities that require surgical intervention.Case: An 80-year-old woman underwent minimally invasive left atrial myxoma excision combined with a maze procedure under general anesthesia. After weaning from cardiopulmonary bypass, routine TEE revealed a small but highly mobile echogenic structure near the right superior pulmonary vein. The operating surgeon was notified, and external palpation localized the finding to the superior left atriotomy, consistent with a redundant atrial tissue flap protruding through the suture line. Reinforcing sutures were placed to incorporate the flap into the closure and eliminate its protrusion into the left atrium. Repeat TEE confirmed complete disappearance of the lesion. The patient recovered without embolic complications.Conclusions: Careful post-bypass TEE examination, including systematic assessment of atriotomy closure sites, may identify potentially embolic mobile echogenic structures and guide surgical management, thereby contributing to perioperative patient safety.
- 12 November 2026
- Published by The Korean Society of Anesthesiologists in Anesthesia and Pain Medicine
Open AccessIntraoperative transesophageal echocardiography detection of a mobile echogenic structure at the left atriotomy suture line - A case report -
Background: Intraoperative transesophageal echocardiography (TEE) provides real-time anatomical and functional assessment during cardiac surgery and may detect abnormalities that require surgical intervention.Case: An 80-year-old woman underwent minimally invasive left atrial myxoma excision combined with a maze procedure under general anesthesia. After weaning from cardiopulmonary bypass, routine TEE revealed a small but highly mobile echogenic structure near the right superior pulmonary vein. The operating surgeon was notified, and external palpation localized the finding to the superior left atriotomy, consistent with a redundant atrial tissue flap protruding through the suture line. Reinforcing sutures were placed to incorporate the flap into the closure and eliminate its protrusion into the left atrium. Repeat TEE confirmed complete disappearance of the lesion. The patient recovered without embolic complications.Conclusions: Careful post-bypass TEE examination, including systematic assessment of atriotomy closure sites, may identify potentially embolic mobile echogenic structures and guide surgical management, thereby contributing to perioperative patient safety.
- Open Access
- 18 February 2025
- Published by Wolters Kluwer Health in ASAIO Journal
Impact of Multistage Cannula on Recirculation in Various Venovenous Extracorporeal Membrane Oxygenation Cannulation Strategies
We aimed to compare recirculation of venovenous extracorporeal membrane oxygenation (V-V ECMO) administered with various cannula placements for femoro-femoral (F-F) and femoro-jugular (F-J) configurations in patients with respiratory failure. This single-center retrospective study included 58 consecutive patients who underwent V-V ECMO between January 2021 and December 2023. Ultrasonic dilution technology was used to quantify the flow of recirculation. The drain cannula placements were categorized into three positions: right atrium and superior and inferior venae cavae. The primary outcome was the difference in recirculation according to the configuration of the V-V ECMO and cannula tip placement. The secondary outcomes were the correlations between recirculation and distance between cannula tips and recirculation difference after cannula adjustment. The recirculation fractions for all types of F-J (27.18%) and F-F (29.33%) configurations were not significantly different. No significant correlation (r = 0.14) was observed between recirculation and the distance between the drain and return cannula tips in chest radiography. The configuration and placement of the drain cannula may have limited effects on recirculation when using a multistage continuous cannula while applying V-V ECMO.
- 18 February 2025
- Published by Wolters Kluwer Health in ASAIO Journal
Open AccessImpact of Multistage Cannula on Recirculation in Various Venovenous Extracorporeal Membrane Oxygenation Cannulation Strategies
We aimed to compare recirculation of venovenous extracorporeal membrane oxygenation (V-V ECMO) administered with various cannula placements for femoro-femoral (F-F) and femoro-jugular (F-J) configurations in patients with respiratory failure. This single-center retrospective study included 58 consecutive patients who underwent V-V ECMO between January 2021 and December 2023. Ultrasonic dilution technology was used to quantify the flow of recirculation. The drain cannula placements were categorized into three positions: right atrium and superior and inferior venae cavae. The primary outcome was the difference in recirculation according to the configuration of the V-V ECMO and cannula tip placement. The secondary outcomes were the correlations between recirculation and distance between cannula tips and recirculation difference after cannula adjustment. The recirculation fractions for all types of F-J (27.18%) and F-F (29.33%) configurations were not significantly different. No significant correlation (r = 0.14) was observed between recirculation and the distance between the drain and return cannula tips in chest radiography. The configuration and placement of the drain cannula may have limited effects on recirculation when using a multistage continuous cannula while applying V-V ECMO.
- Open Access
- 31 May 2024
- Published by The Korean Society of Critical Care Medicine in Acute and Critical Care
- Vol. 39 (2) , 266-274
Catheter detection by transthoracic echocardiography during placement of peripherally inserted central catheters: a real-time method for eliminating misplacement
Background: Although guidelines and protocols are available for central venous access, existing methods lack specificity and sensitivity, especially when placing peripherally inserted central catheters (PICCs). We evaluated the feasibility of catheter detection in the right atrial cavity using transthoracic echocardiography (TTE) during PICC placement.Methods: This single-center, retrospective study included consecutive patients who underwent PICC placement between January 2022 and March 2023. TTE was performed to detect the arrival of the catheter in the right atrial cavity. Catheter misplacement was defined as an aberrant catheter position on chest x-ray (CXR). The primary endpoint was predicting catheter misplacement based on catheter detection in the right atrial cavity. The secondary endpoint was optimizing catheter placement and examining catheter-associated complications.Results: Of the 110 patients identified, 10 were excluded because of poor echogenicity and vein access failure. The remaining 100 patients underwent PICC placement with TTE. The catheter was visualized in the right atrial cavity in 90 patients. CXR exams revealed catheter misplacement in seven cases. Eight patients with catheter misplacement underwent the same procedure in the other arm. In two patients, PICC placement failed due to anatomical reasons. Catheter misplacement was detected using TTE with sensitivity, specificity, positive predictive value, and negative predictive value of 97% confidence interval (CI, 91.31%–99.36%), 90% CI (55.50%–99.75%), 99%, and 75%, respectively.Conclusions: TTE is a reliable tool for detecting catheter misplacement and optimizing catheter tip positioning during PICC placement.
- 31 May 2024
- Published by The Korean Society of Critical Care Medicine in Acute and Critical Care
- Vol. 39 (2) , 266-274
Open AccessCatheter detection by transthoracic echocardiography during placement of peripherally inserted central catheters: a real-time method for eliminating misplacement
Background: Although guidelines and protocols are available for central venous access, existing methods lack specificity and sensitivity, especially when placing peripherally inserted central catheters (PICCs). We evaluated the feasibility of catheter detection in the right atrial cavity using transthoracic echocardiography (TTE) during PICC placement.Methods: This single-center, retrospective study included consecutive patients who underwent PICC placement between January 2022 and March 2023. TTE was performed to detect the arrival of the catheter in the right atrial cavity. Catheter misplacement was defined as an aberrant catheter position on chest x-ray (CXR). The primary endpoint was predicting catheter misplacement based on catheter detection in the right atrial cavity. The secondary endpoint was optimizing catheter placement and examining catheter-associated complications.Results: Of the 110 patients identified, 10 were excluded because of poor echogenicity and vein access failure. The remaining 100 patients underwent PICC placement with TTE. The catheter was visualized in the right atrial cavity in 90 patients. CXR exams revealed catheter misplacement in seven cases. Eight patients with catheter misplacement underwent the same procedure in the other arm. In two patients, PICC placement failed due to anatomical reasons. Catheter misplacement was detected using TTE with sensitivity, specificity, positive predictive value, and negative predictive value of 97% confidence interval (CI, 91.31%–99.36%), 90% CI (55.50%–99.75%), 99%, and 75%, respectively.Conclusions: TTE is a reliable tool for detecting catheter misplacement and optimizing catheter tip positioning during PICC placement.
- Open Access
- 22 September 2022
- Published by Korean Neuropsychiatric Association in Psychiatry Investigation
- Vol. 19 (9) , 748-753
Validation of the Korean Version of the Delirium Diagnostic Tool-Provisional (K-DDT-Pro)
Objective The Delirium Diagnostic Tool-Provisional (DDT-Pro) was designed to detect the presence and severity of delirium briefly and objectively regardless of psychiatric expertise. We translated the DDT-Pro into Korean and validated it in elderly Korean patients.Methods To validate the translation and evaluate inter-rater reliability, a psychiatric trainee and a research nurse independently assessed the same patients referred to the Department of Psychiatry. The results were compared with the reference evaluations performed by a psychiatrist using the Diagnostic and Statistical Manual of Mental Disorders, 5th Edition (DSM-5).Results We enrolled 42 elderly patients. The Cronbach’s alpha coefficient were 0.839 (the trainee), 0.822 (the nurse). The Cohen’s weighted κ between the trainee and nurse, ranged from 0.555±0.102 to 0.776±0.062. The Pearson correlation coefficients (Korean version of the DDT-Pro [K-DDT-Pro] and Korean version of the Delirium Rating Scale-Revised-98 [DRS-R98-K] total score) were γ=-0.850 (the trainee), and γ=-0.821 (the nurse). The areas under the ROC curves (AUCs) were 0.974 (the trainee) and 0.893 (the nurse).Conclusion The K-DDT-Pro exhibited high internal consistency and relatively substantial inter-rater reliability. The correlation with the DRS-R98-K was strongly negative. The accuracy of the K-DDT-Pro was excellent, regardless of expertise. In conclusion, the K-DDT-Pro is a brief and simple tool that usefully screens for delirium in elderly patients.
- 22 September 2022
- Published by Korean Neuropsychiatric Association in Psychiatry Investigation
- Vol. 19 (9) , 748-753
Open AccessValidation of the Korean Version of the Delirium Diagnostic Tool-Provisional (K-DDT-Pro)
Objective The Delirium Diagnostic Tool-Provisional (DDT-Pro) was designed to detect the presence and severity of delirium briefly and objectively regardless of psychiatric expertise. We translated the DDT-Pro into Korean and validated it in elderly Korean patients.Methods To validate the translation and evaluate inter-rater reliability, a psychiatric trainee and a research nurse independently assessed the same patients referred to the Department of Psychiatry. The results were compared with the reference evaluations performed by a psychiatrist using the Diagnostic and Statistical Manual of Mental Disorders, 5th Edition (DSM-5).Results We enrolled 42 elderly patients. The Cronbach’s alpha coefficient were 0.839 (the trainee), 0.822 (the nurse). The Cohen’s weighted κ between the trainee and nurse, ranged from 0.555±0.102 to 0.776±0.062. The Pearson correlation coefficients (Korean version of the DDT-Pro [K-DDT-Pro] and Korean version of the Delirium Rating Scale-Revised-98 [DRS-R98-K] total score) were γ=-0.850 (the trainee), and γ=-0.821 (the nurse). The areas under the ROC curves (AUCs) were 0.974 (the trainee) and 0.893 (the nurse).Conclusion The K-DDT-Pro exhibited high internal consistency and relatively substantial inter-rater reliability. The correlation with the DRS-R98-K was strongly negative. The accuracy of the K-DDT-Pro was excellent, regardless of expertise. In conclusion, the K-DDT-Pro is a brief and simple tool that usefully screens for delirium in elderly patients.
- Open Access
- 6 October 2021
- Published by Elsevier in JACC: Case Reports
- Vol. 3 (13) , 1535-1540
Mass Lesions That Almost Fill the Ascending Aorta
- 6 October 2021
- Published by Elsevier in JACC: Case Reports
- Vol. 3 (13) , 1535-1540
Open AccessMass Lesions That Almost Fill the Ascending Aorta
- Open Access
- 5 February 2021
- Published by Korean Society for Thoracic and Cardiovascular Surgery in Journal of Chest Surgery
- Vol. 54 (1) , 2-8
Extracorporeal Membrane Oxygenation for Coronavirus Disease 2019: Expert Recommendations from The Korean Society for Thoracic and Cardiovascular Surgery
In Seok Jeong, M.D., Woong-Han Kim, M.D., Jong Hyun Baek, M.D., Chang-Hyu Choi, M.D., Chang Woo Choi, M.D., Euy Suk Chung, M.D., Jae Seok Jang, M.D., Woo Sung Jang, M.D., Hanna Jung, M.D., Jae-Seung Jung, M.D., Pil Je Kang, M.D., Dong Jung Kim, M.D., Do Wan Kim, M.D., Hyoung Soo Kim, M.D., Jae Bum Kim, M.D., Woo-Shik Kim, M.D., Young Sam Kim, M.D., Jae Gun Kwak, M.D., Haeyoung Lee, M.D., Seok In Lee, M.D., Jae Woong Lim, M.D., Se Jin Oh, M.D., Tak-Hyuck Oh, M.D., Chun Soo Park, M.D., Kyoung Min Ryu, M.D., Man-Shik Shim, M.D., Joohyung Son, M.D., Kuk Hui Son, M.D., Seunghwan Song, M.D., on behalf of The Korean Society for Thoracic and Cardiovascular Surgery COVID- ECMO Task Force Team. J Chest Surg 2021;54:2-8. https://doi.org/10.5090/kjtcs.21.001
- 5 February 2021
- Published by Korean Society for Thoracic and Cardiovascular Surgery in Journal of Chest Surgery
- Vol. 54 (1) , 2-8
Open AccessExtracorporeal Membrane Oxygenation for Coronavirus Disease 2019: Expert Recommendations from The Korean Society for Thoracic and Cardiovascular Surgery
In Seok Jeong, M.D., Woong-Han Kim, M.D., Jong Hyun Baek, M.D., Chang-Hyu Choi, M.D., Chang Woo Choi, M.D., Euy Suk Chung, M.D., Jae Seok Jang, M.D., Woo Sung Jang, M.D., Hanna Jung, M.D., Jae-Seung Jung, M.D., Pil Je Kang, M.D., Dong Jung Kim, M.D., Do Wan Kim, M.D., Hyoung Soo Kim, M.D., Jae Bum Kim, M.D., Woo-Shik Kim, M.D., Young Sam Kim, M.D., Jae Gun Kwak, M.D., Haeyoung Lee, M.D., Seok In Lee, M.D., Jae Woong Lim, M.D., Se Jin Oh, M.D., Tak-Hyuck Oh, M.D., Chun Soo Park, M.D., Kyoung Min Ryu, M.D., Man-Shik Shim, M.D., Joohyung Son, M.D., Kuk Hui Son, M.D., Seunghwan Song, M.D., on behalf of The Korean Society for Thoracic and Cardiovascular Surgery COVID- ECMO Task Force Team. J Chest Surg 2021;54:2-8. https://doi.org/10.5090/kjtcs.21.001
- Open Access
- 1 January 2020
- Published by Korean Society of Echocardiography in Journal of Cardiovascular Imaging
- Vol. 28 (3) , 213-215
Acquired Left Ventricular Gerbode's Defect after Mitral Valve Replacement
Lee S, et al. J Cardiovasc Imaging. 2019 Sep;28:e19. https://doi.org/10.4250/jcvi.2019.0101
- 1 January 2020
- Published by Korean Society of Echocardiography in Journal of Cardiovascular Imaging
- Vol. 28 (3) , 213-215
Open AccessAcquired Left Ventricular Gerbode's Defect after Mitral Valve Replacement
Lee S, et al. J Cardiovasc Imaging. 2019 Sep;28:e19. https://doi.org/10.4250/jcvi.2019.0101