  • Open Access

    The General Method for the fire design of I-section web-tapered beam–columns

    by Élio Maia, Carlos Couto, Paulo Vila Real, Nuno Lopes


  • The General Method for the fire design of I‐section web‐tapered beams

    by Élio Maia, Paulo Vila Real, Nuno Lopes, Carlos Couto

    The present investigation describes a numerical and parametric study on the validation of the General Method (GM) for the fire design of web‐tapered steel beams using GMNIA. The GM (clause 6.3.4 of EN 1993‐1‐1) covers the safety check of structural elements with complex support conditions and/or of non‐prismatic members. However, the fire part of the Eurocode 3 (EN 1993‐1‐2) gives no further indication regarding its applicability at elevated temperatures, apart from adapting the methodology to fire using the reduction factors for steel material properties, which is identified as a gap in the current version of the norm.Previous investigations by the authors have shown overly conservative results for the General Method and a calibration of the EN 1993‐1‐2 buckling curve has previously been proposed, although the parametric performed in that study was not extensive enough for a full validation. With that in mind, the present paper has improved these shortcomings by further upgrading the Eurocode 3 formulation and validating the proposal against numerical data from more than 25000 GMNIA simulations.

  • Stability check of tapered steel beams in fire

    by Carlos Couto, Élio Maia, Paulo Vila Real, Nuno Lopes

    Purpose: The purpose of this paper is to assess whether the adaptation to fire of current proposals/design methodologies at normal temperature is capable of producing accurate predictions of resistance for the out-of-plane stability of tapered beams. Design/methodology/approach: The adaptation of these methodologies to fire has been done by accounting for the reduction in steel material properties with the temperature. Results were then compared to FEM calculations by performing GMNIA analyses to determine the ultimate strength of the numerical models and to ascertain the validity and accuracy of the adapted methodologies. Findings: Although all methodologies produce safe results at normal temperatures, only the general method is recommended for the safety verification at elevated temperatures, although the data points were overly conservative. This investigation demonstrates the need of proper and accurate design methods for tapered beams at elevated temperatures, which should be the subject of future developments. Research limitations/implications: The research in this paper is limited to the adaptation of existing room temperature design methods to fire. Therefore, possible assumptions made during the conception of the initial formulae, which may be valid exclusively for 20ºC, may have been disregarded. Originality/value: For the time being, design methodologies for the safety check of tapered beams for the case of fire are inexistent. This paper investigates the adaptation of existing room temperature design to the fire situation by providing insights on their accuracy level, as well as on how to proceed. Finally, a safe design methodology for tapered beams in case of fire is provided until improved design methods are developed.


  • Open Access

    General Method for the fire design of tapered steel columns: Out‐of‐plane flexural buckling

    by Élio Maia, Paulo Vila Real, Nuno Lopes, Carlos Couto


  • 10.09: Critical temperatures of members with class 4 cross‐section

    by Élio Maia, Carlos Couto, Paulo Vila Real, Nuno Lopes

    This paper describes a numerical investigation on the critical temperatures of members with Class 4 cross‐sections according to Eurocode 3 design. For such sections, the norm suggests the use of a default critical temperature of 350 °C irrespective of the load level conditions if no other calculation is made. On that regard, the authors have previously demonstrated that this temperature might be too conservative for certain conditions, especially if different degrees of utilization are taken into account. As a consequence, the authors recommended and validated new default critical temperatures for Class 4 cross‐sections subjected to compression and bending about the major axis, for different reduction factors for the design load level under fire conditions.Building up on said studies regarding slender cross‐sections, the present work aims at extending and establishing the groundwork for future studies on the critical temperature of members subjected to fire with the ultimate goal of achieving and validating a wide‐reaching proposal of more appropriate default critical temperatures for steel members and cross‐sections subjected to fire.From this study it was observed that the critical temperatures for laterally restrained members (in‐plane) are in agreement with those proposed in previous research by the authors. The out‐of‐plane simulations, however, displayed similar patterns to those of their in‐plane counterparts up until a certain slenderness threshold, after which a noticeable loss of resistance seems to occur, likely due to the higher influence of second‐order effects in the out‐of‐plane direction.


  • Critical temperatures of class 4 cross-sections

    by Élio Maia, Carlos Couto, Paulo Vila Real, Nuno Lopes