Leandro Kolling
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Leandro Kolling has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Márcia Messias da Silva
Chemistry Institute, Federal University of Rio Grande do Sul, Porto Alegre 90010-150, RS, Brazil
6 shared publications - Morgana Bazzan Dessuy
Universidade Federal do Rio Grande do Sul
4 shared publications Maria Goreti Rodrigues Vale
Instituto de Química, Universidade Federal do Rio Grande do Sul, 91501-970, Porto Alegre, RS, Brazil; Instituto Nacional de Ciência e Tecnologia do CNPq - INCT de Energia e Ambiente, Universidade Federal da Bahia, 40170-115, Salvador, BA, Brazil
3 shared publications- Alexandre B. Schneider
Instituto de Química, Universidade Federal Do Rio Grande Do Sul, Av. Bento Gonçalves 9500, C.P. 15003, 91501-970, Porto Alegre, RS, Brazil
2 shared publications Alexandre de Jesus
2 shared publications- Cristian H. Krause
Instituto de Química, Universidade Federal Do Rio Grande Do Sul, Av. Bento Gonçalves 9500, C.P. 15003, 91501-970, Porto Alegre, RS, Brazil
2 shared publications
Latest Publications
- 29 December 2025
- Published by Elsevier in Atmospheric Pollution Research
- Vol. 17 (5)
Chemical composition and potential health risks of rainwater from coal processing sites: A case study in southern Brazil
- 29 December 2025
- Published by Elsevier in Atmospheric Pollution Research
- Vol. 17 (5)
Chemical composition and potential health risks of rainwater from coal processing sites: A case study in southern Brazil
- Open Access
- 7 December 2024
- Published by MDPI AG in Separations
- Vol. 11 (12) , 346
Eco-Friendly Capillary Electrophoresis Method for the Quantification of Apixaban in Oral Dosage Form
The present work describes, for the first time, an eco-friendly capillary zone electrophoresis (CZE) methodology for determining apixaban (APX), an oral anticoagulant. Separation was carried out using a fused silica capillary with an applied voltage of 20 kV and hydrodynamic injection for 5 s at 50 mbar. The electrolyte system consisted of 50 mM sodium borate at pH 8.0. The method was validated as recommended by ICH, establishing selectivity, linearity, precision, accuracy, and robustness. The analytical procedure was linear in the range of 10–125 µg mL−1 (r = 0.999). The limits of detection and quantification were determined to be 1.77 µg mL−1 and 5.37 µg mL−1, respectively. Precision was evaluated by relative standard deviation (RSD), with an intra-day RSD (n = 6) of 0.96% and an inter-day RSD (n = 18) of 4.42%. The average recovery rates for the pharmaceutical samples were excellent, ranging from 98.03% to 101.01%, with an RSD of 1.51%. Moreover, the green profile of the method was evaluated using the National Environmental Methods Index (NEMI), Analytical Eco-Scale, Green Analytical Procedure Index (GAPI), and Analytical GREEnness Metric (AGREE) assessment tools. The results suggest that the CZE method aligns with the principles of green chemistry, offering a greener alternative for the routine analysis of APX quality control. Also, the method presents a low-cost analysis, using fewer organic solvents and minimizing waste generation compared to techniques commonly used in routine analysis.
- 7 December 2024
- Published by MDPI AG in Separations
- Vol. 11 (12) , 346
Open AccessEco-Friendly Capillary Electrophoresis Method for the Quantification of Apixaban in Oral Dosage Form
The present work describes, for the first time, an eco-friendly capillary zone electrophoresis (CZE) methodology for determining apixaban (APX), an oral anticoagulant. Separation was carried out using a fused silica capillary with an applied voltage of 20 kV and hydrodynamic injection for 5 s at 50 mbar. The electrolyte system consisted of 50 mM sodium borate at pH 8.0. The method was validated as recommended by ICH, establishing selectivity, linearity, precision, accuracy, and robustness. The analytical procedure was linear in the range of 10–125 µg mL−1 (r = 0.999). The limits of detection and quantification were determined to be 1.77 µg mL−1 and 5.37 µg mL−1, respectively. Precision was evaluated by relative standard deviation (RSD), with an intra-day RSD (n = 6) of 0.96% and an inter-day RSD (n = 18) of 4.42%. The average recovery rates for the pharmaceutical samples were excellent, ranging from 98.03% to 101.01%, with an RSD of 1.51%. Moreover, the green profile of the method was evaluated using the National Environmental Methods Index (NEMI), Analytical Eco-Scale, Green Analytical Procedure Index (GAPI), and Analytical GREEnness Metric (AGREE) assessment tools. The results suggest that the CZE method aligns with the principles of green chemistry, offering a greener alternative for the routine analysis of APX quality control. Also, the method presents a low-cost analysis, using fewer organic solvents and minimizing waste generation compared to techniques commonly used in routine analysis.
- 15 October 2024
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 108 (1) , 1-9
Development, Validation, and Application of a Fast Sequential Method for Na, K, Ca, and Mg Determination in Hemodialysis Solutions by HR-CS F AAS
Background: Hemodialysis solutions are liquid concentrates used during hemodialysis sessions. They are commonly used as a renal replacement therapy. Objective: This study aimed to develop a method to determine Na, K, Ca, and Mg in hemodialysis solutions by high-resolution continuum source flame atomic absorption spectrometry (HR-CS F AAS) using Design of Experiments (DOE). Methods: The combination of the Doehlert Matrix with the desirability function was used to establish a compromise condition in the optimization of the significant variables studied: 60 L/h for acetylene flow rate, 8 mm for burner height, and 0.25% (w/v) and 0.60% (w/v) for Cs and La concentrations. The method was validated by following the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) guidelines and parameters, and, as such, the selectivity, linearity, precision, accuracy, and robustness were evaluated. Results: Calibration curves with the ranges of 25–130 mg/L for Na, 1.0–5.0 mg/L for K and Ca, and 0.30–0.70 mg/L for Mg were employed. The method proved to be precise (RSD lower than 2.7%) and accurate (mean recovery data, contemplating the three levels added, were 103.0% for Na, 100.5% for K, 101.3% for Ca, and 101.5% for Mg). Conclusions: The developed method enables the sequential multielement determination of Na, K, Ca, and Mg in a single run. Requiring only one dilution step, this method significantly reduces analysis time for both sample and standard solution preparation and measurement. Highlights: This study presents the first method reported in the literature for multielement determination in hemodialysis solutions, offering an alternative approach to the current European Pharmacopeia method.
- 15 October 2024
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 108 (1) , 1-9
Development, Validation, and Application of a Fast Sequential Method for Na, K, Ca, and Mg Determination in Hemodialysis Solutions by HR-CS F AAS
Background: Hemodialysis solutions are liquid concentrates used during hemodialysis sessions. They are commonly used as a renal replacement therapy. Objective: This study aimed to develop a method to determine Na, K, Ca, and Mg in hemodialysis solutions by high-resolution continuum source flame atomic absorption spectrometry (HR-CS F AAS) using Design of Experiments (DOE). Methods: The combination of the Doehlert Matrix with the desirability function was used to establish a compromise condition in the optimization of the significant variables studied: 60 L/h for acetylene flow rate, 8 mm for burner height, and 0.25% (w/v) and 0.60% (w/v) for Cs and La concentrations. The method was validated by following the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH) guidelines and parameters, and, as such, the selectivity, linearity, precision, accuracy, and robustness were evaluated. Results: Calibration curves with the ranges of 25–130 mg/L for Na, 1.0–5.0 mg/L for K and Ca, and 0.30–0.70 mg/L for Mg were employed. The method proved to be precise (RSD lower than 2.7%) and accurate (mean recovery data, contemplating the three levels added, were 103.0% for Na, 100.5% for K, 101.3% for Ca, and 101.5% for Mg). Conclusions: The developed method enables the sequential multielement determination of Na, K, Ca, and Mg in a single run. Requiring only one dilution step, this method significantly reduces analysis time for both sample and standard solution preparation and measurement. Highlights: This study presents the first method reported in the literature for multielement determination in hemodialysis solutions, offering an alternative approach to the current European Pharmacopeia method.
- 1 January 2023
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
Extraction Induced by Microemulsion Breaking and Square Wave Voltammetry: A Promising Union to Monitor Cd, Pb and Cu in Biodiesel
A new approach involving square wave anodic stripping voltammetry was developed to simultaneously determine cadmium and lead and, in the same cell, sequentially copper, in biodiesel after extraction induced by microemulsion breaking. The composition of the water-in-oil microemulsion involved 10.50 mL biodiesel, 4.20 mL n-propanol and 0.30 mL of the 6.0 mol L-1 HNO3 solution. The extraction was carried out by adding 1.10 mL ultrapure water resulting in two well separated phases: an upper organic phase, and a lower aqueous phase containing the analytes. The apparatus comprised a portable potentiostat and a cell with an in situ plated mercury film glassy carbon electrode as working electrode. The limits of detection for Cd, Pb and Cu were 0.33, 0.48 and 0.66 μg L-1, respectively. The accuracy of the method was evaluated by recovery assays of spiked samples and by analyzing a standard reference material.
- 1 January 2023
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
Extraction Induced by Microemulsion Breaking and Square Wave Voltammetry: A Promising Union to Monitor Cd, Pb and Cu in Biodiesel
A new approach involving square wave anodic stripping voltammetry was developed to simultaneously determine cadmium and lead and, in the same cell, sequentially copper, in biodiesel after extraction induced by microemulsion breaking. The composition of the water-in-oil microemulsion involved 10.50 mL biodiesel, 4.20 mL n-propanol and 0.30 mL of the 6.0 mol L-1 HNO3 solution. The extraction was carried out by adding 1.10 mL ultrapure water resulting in two well separated phases: an upper organic phase, and a lower aqueous phase containing the analytes. The apparatus comprised a portable potentiostat and a cell with an in situ plated mercury film glassy carbon electrode as working electrode. The limits of detection for Cd, Pb and Cu were 0.33, 0.48 and 0.66 μg L-1, respectively. The accuracy of the method was evaluated by recovery assays of spiked samples and by analyzing a standard reference material.