Kayeon Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kayeon Kim has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Changsi Cai
University of Copenhagen
7 shared publications - Anpan Han
Technical University of Denmark
6 shared publications - Choongkil Lee
Department of Psychology, Seoul National University, Kwanak, Seoul 151–742, Korea
5 shared publications Lechan Tao
Department of Neuroscience, Faculty of Health and Medical Science, University of Copenhagen, Copenhagen N, Denmark
5 shared publicationsXiao Zhang
Department of Neuroscience, Faculty of Health and Medical Science, University of Copenhagen, Copenhagen N, Denmark
5 shared publicationsAlexandra Katherine Isis Yonza
Department of Neuroscience, Faculty of Health and Medical Science, University of Copenhagen, Copenhagen N, Denmark
4 shared publications
Latest Publications
- Open Access
Microscopic Neuromodulation with Locally Enhanced Electric Field
Implantable neural stimulation devices play an important role in fundamental neuroscience research, clinical applications, and emerging technologies such as neuroprosthetics and brain machine interfaces, with increasing demand for spatially precise neuromodulation at cellular and circuit levels. Microelectrode based electrical stimulation relies on charge injection into neural tissue, where irreversible electrochemical reactions at the electrode electrolyte interface may lead to electrode degradation and tissue damage. Although microscale magnetic stimulation provides an alternative, it typically requires sophisticated microcoil architectures and complex fabrication processes. In this work, we introduce a novel neural stimulation mechanism based on localized electric field enhancement. The proposed device employs an electrically insulated sharp metallic tip to concentrate the electric field and generate localized displacement currents capable of activating nearby neurons. Finite element simulations were performed to investigate the underlying stimulation mechanism and establish design guidelines for device fabrication. MEMS based neural probes were subsequently fabricated and experimentally evaluated through in vivo animal studies, with neuronal activation observed at distances of less than 200 micrometers from the probe tip using two-photon imaging. By avoiding Faradaic charge transfer at the tissue interface while offering high spatial localization, orientation selectivity, and a compact device architecture, the proposed approach provides a promising alternative to existing stimulation technologies for chronic and high-density neural interfaces.
Open AccessMicroscopic Neuromodulation with Locally Enhanced Electric Field
Implantable neural stimulation devices play an important role in fundamental neuroscience research, clinical applications, and emerging technologies such as neuroprosthetics and brain machine interfaces, with increasing demand for spatially precise neuromodulation at cellular and circuit levels. Microelectrode based electrical stimulation relies on charge injection into neural tissue, where irreversible electrochemical reactions at the electrode electrolyte interface may lead to electrode degradation and tissue damage. Although microscale magnetic stimulation provides an alternative, it typically requires sophisticated microcoil architectures and complex fabrication processes. In this work, we introduce a novel neural stimulation mechanism based on localized electric field enhancement. The proposed device employs an electrically insulated sharp metallic tip to concentrate the electric field and generate localized displacement currents capable of activating nearby neurons. Finite element simulations were performed to investigate the underlying stimulation mechanism and establish design guidelines for device fabrication. MEMS based neural probes were subsequently fabricated and experimentally evaluated through in vivo animal studies, with neuronal activation observed at distances of less than 200 micrometers from the probe tip using two-photon imaging. By avoiding Faradaic charge transfer at the tissue interface while offering high spatial localization, orientation selectivity, and a compact device architecture, the proposed approach provides a promising alternative to existing stimulation technologies for chronic and high-density neural interfaces.
- Open Access
- 1 October 2026
- Published by Springer Nature in Communications Biology
Single-cell and population-level neuromodulation dynamics in dual-electrode intracortical microstimulation
- 1 October 2026
- Published by Springer Nature in Communications Biology
Open AccessSingle-cell and population-level neuromodulation dynamics in dual-electrode intracortical microstimulation
- Open Access
- 25 June 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (4) , 046010
Spatiotemporally distinctive astrocytic and neuronal responses to repetitive intracortical microstimulation
Objective Astrocytes are increasingly recognized as active modulators of neuronal synaptic transmission. Intracortical microstimulation (ICMS) is widely used to manipulate neuronal activity, yet the accompanying astrocytic responses remain poorly characterized. This study aims to systematically characterize and compare astrocytic and neuronal spatiotemporal dynamics evoked by ICMS. Approach We combined ICMS with dual-color in vivo two photon calcium imaging in mouse visual cortex to simultaneously measure neuronal and astrocytic activity and analyzed their spatial recruitment and temporal dynamics. Main results Astrocytes were robustly recruited by ICMS at currents as low as 10 μA, comparable to neuronal activation thresholds. Unlike neurons, astrocytic responses exhibited weaker spatial dependence on electrode proximity and greater temporal variability across trials. At higher stimulation intensities (>=50 μA), astrocytic response magnitude and responsiveness (i.e., response peak amplitude, number of responsive trials), attenuated across repeated trials and fell below the detection threshold. Neuronal responses decreased in magnitude across trials as well but remained reliably above activation threshold. Despite these distinctions, astrocytic activation was correlated with neuronal activity: regions with active astrocytes exhibited higher neuronal response magnitudes, while astrocytic responses were strongest in regions lacking neuronal somata, potentially indicating preferential activity at neuronal processes. Significance These results establish astrocytes as an active and distinct component of ICMS-evoked cortical dynamics, whose activity is coupled to neuronal responses yet exhibits spatial specificity, highlighting the importance of incorporating glial signaling into the interpretation and optimization of neurostimulation and neuroprosthetic strategies.
- 25 June 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (4) , 046010
Open AccessSpatiotemporally distinctive astrocytic and neuronal responses to repetitive intracortical microstimulation
Objective Astrocytes are increasingly recognized as active modulators of neuronal synaptic transmission. Intracortical microstimulation (ICMS) is widely used to manipulate neuronal activity, yet the accompanying astrocytic responses remain poorly characterized. This study aims to systematically characterize and compare astrocytic and neuronal spatiotemporal dynamics evoked by ICMS. Approach We combined ICMS with dual-color in vivo two photon calcium imaging in mouse visual cortex to simultaneously measure neuronal and astrocytic activity and analyzed their spatial recruitment and temporal dynamics. Main results Astrocytes were robustly recruited by ICMS at currents as low as 10 μA, comparable to neuronal activation thresholds. Unlike neurons, astrocytic responses exhibited weaker spatial dependence on electrode proximity and greater temporal variability across trials. At higher stimulation intensities (>=50 μA), astrocytic response magnitude and responsiveness (i.e., response peak amplitude, number of responsive trials), attenuated across repeated trials and fell below the detection threshold. Neuronal responses decreased in magnitude across trials as well but remained reliably above activation threshold. Despite these distinctions, astrocytic activation was correlated with neuronal activity: regions with active astrocytes exhibited higher neuronal response magnitudes, while astrocytic responses were strongest in regions lacking neuronal somata, potentially indicating preferential activity at neuronal processes. Significance These results establish astrocytes as an active and distinct component of ICMS-evoked cortical dynamics, whose activity is coupled to neuronal responses yet exhibits spatial specificity, highlighting the importance of incorporating glial signaling into the interpretation and optimization of neurostimulation and neuroprosthetic strategies.
- Open Access
“Tone‐Arm” Neuromodulation MEMS Microcoil for In Vivo Imaging
Implantable neural interfaces have revolutionized neuromodulation by enabling bidirectional communication between neural circuits and external devices. Yet, existing modalities face important challenges in precision, high invasiveness, and compatibility with advanced in vivo imaging systems. We report a MEMS‐based “tone‐arm” micro‐coil design optimized for vertical cortical insertion, featuring an 800‐µm cantilever with a small cross‐section that reconciles mechanical robustness with two‐photon microscopy compatible miniaturization. Numerical modeling spanning electromagnetic field gradients, thermodynamic safety margins, and buckling resistance guided our MEMS device design process. Our toxic‐etchants‐free 3‐stage and 4‐mask fabrication process yielded micro‐coil devices compatible with in vivo two‐photon imaging. Our vertically integrated probe design overcomes longstanding optical obstruction challenges, preserving >95% imaging field visibility during in vivo studies. This platform enables simultaneous micromagnetic neuromodulation and subcellular‐resolution calcium imaging, opening unprecedented opportunities to dissect neural circuit dynamics during targeted intervention. Thermodynamic modelling showed the record low probe resistance (2 Ω) is safe for implantation and limits tissue heating to < 0.2°C. The low‐invasive cross‐section (70 × 86 µm 2 ), and mechanical robust brain insertions were critical to achieving robust neuromodulation, including neuro‐inhibition—a capability long sought for the potential treatment of hyperactivity‐driven neurological disorders.
Open Access“Tone‐Arm” Neuromodulation MEMS Microcoil for In Vivo Imaging
Implantable neural interfaces have revolutionized neuromodulation by enabling bidirectional communication between neural circuits and external devices. Yet, existing modalities face important challenges in precision, high invasiveness, and compatibility with advanced in vivo imaging systems. We report a MEMS‐based “tone‐arm” micro‐coil design optimized for vertical cortical insertion, featuring an 800‐µm cantilever with a small cross‐section that reconciles mechanical robustness with two‐photon microscopy compatible miniaturization. Numerical modeling spanning electromagnetic field gradients, thermodynamic safety margins, and buckling resistance guided our MEMS device design process. Our toxic‐etchants‐free 3‐stage and 4‐mask fabrication process yielded micro‐coil devices compatible with in vivo two‐photon imaging. Our vertically integrated probe design overcomes longstanding optical obstruction challenges, preserving >95% imaging field visibility during in vivo studies. This platform enables simultaneous micromagnetic neuromodulation and subcellular‐resolution calcium imaging, opening unprecedented opportunities to dissect neural circuit dynamics during targeted intervention. Thermodynamic modelling showed the record low probe resistance (2 Ω) is safe for implantation and limits tissue heating to < 0.2°C. The low‐invasive cross‐section (70 × 86 µm 2 ), and mechanical robust brain insertions were critical to achieving robust neuromodulation, including neuro‐inhibition—a capability long sought for the potential treatment of hyperactivity‐driven neurological disorders.
- Open Access
Spatiotemporally distinctive astrocytic and neuronal responses to repetitive intracortical microstimulation
Astrocytes are increasingly recognized as active modulators of neuronal synaptic transmission. Intracortical microstimulation (ICMS) is widely used to manipulate neuronal activity, yet the accompanying astrocytic responses remain poorly characterized. Using dual-color in vivo two-photon calcium imaging to simultaneously monitor neurons and astrocytes, we show that ICMS elicits astrocytic activation with spatiotemporal features that diverge from those of neurons. Astrocytes were recruited at stimulation intensities as low as 10μA, thresholds sufficient to activate neurons, indicating that astrocytes robustly sense electrical perturbation. Unlike neurons, however, astrocytic responses were spatially heterogeneous and temporally variable across trials. At higher stimulation intensities (>=50μA), astrocytic responsiveness, i.e., response peak amplitude, and number of responsive trials, progressively attenuated across repeated trials, in contrast to the stable and consistent neuronal responses. Although neuronally driven, astrocytes exhibited a distinct response profile under the same stimulation parameter, revealing a unique component of electrically evoked cortical activity that underscores the importance of incorporating glial physiology into future neuroprosthetic strategies.
Open AccessSpatiotemporally distinctive astrocytic and neuronal responses to repetitive intracortical microstimulation
Astrocytes are increasingly recognized as active modulators of neuronal synaptic transmission. Intracortical microstimulation (ICMS) is widely used to manipulate neuronal activity, yet the accompanying astrocytic responses remain poorly characterized. Using dual-color in vivo two-photon calcium imaging to simultaneously monitor neurons and astrocytes, we show that ICMS elicits astrocytic activation with spatiotemporal features that diverge from those of neurons. Astrocytes were recruited at stimulation intensities as low as 10μA, thresholds sufficient to activate neurons, indicating that astrocytes robustly sense electrical perturbation. Unlike neurons, however, astrocytic responses were spatially heterogeneous and temporally variable across trials. At higher stimulation intensities (>=50μA), astrocytic responsiveness, i.e., response peak amplitude, and number of responsive trials, progressively attenuated across repeated trials, in contrast to the stable and consistent neuronal responses. Although neuronally driven, astrocytes exhibited a distinct response profile under the same stimulation parameter, revealing a unique component of electrically evoked cortical activity that underscores the importance of incorporating glial physiology into future neuroprosthetic strategies.
- Open Access
Single-Cell and Population-Level Neuromodulation Dynamics in Dual-Electrode Intracortical Stimulation
In neuroprosthetics, intracortical microstimulation (ICMS) recruits cortical networks to evoke brain responses and sensory perceptions. However, multi-electrode ICMS often generates suboptimal percepts compared to single-electrode ICMS, suggesting nonlinear neuromodulation rather than simple summation by multi-electrode ICMS. Yet, the factors and mechanisms underlying this modulation remain poorly understood. To investigate multi-electrode ICMS, we combined two-photon calcium imaging with a well-controlled dual-electrode ICMS in the mouse visual cortex to investigate how neurons integrate converging ICMS inputs at varying intensities. We found that stimulation intensity significantly shapes neuromodulation at both single-cell and population levels. Specifically, low intensities (5-7 µA) have a minimal effect on neural responses. At intermediate intensities (10-15 µA), we observed diverse, nonlinear bipolar modulation—both enhancement and attenuation—at the single-cell level. However, we achieved net enhancement at the population level. At higher intensities (15–20 µA), although the proportion of modulated neurons increased in both enhancement and attenuation directions, the net effect at the population level was neutral (zero modulation). Furthermore, neurons strongly responsive to single-electrode ICMS were more likely to be attenuated, while weaker responding cells exhibited enhanced modulation. The strongest neuromodulatory effects occur at intermediate spatial distances in between the two electrodes. Computational modeling based on spiking neural network composed of adaptive exponential integrate-and-field neurons implicated the importance of inhibitory network dynamics and network variability as key mechanisms. Our experimental data was used to train an advanced deep learning approach, which successfully predicted the neuromodulation patterns induced by dual-electrode ICMS. Our findings reveal intensity- and spatial-dependent rules of neuromodulation by ICMS, providing necessary insights to optimize multi-electrode ICMS for neuroprosthetic applications. Significance statement Understanding how cortical neurons integrate concurrent inputs from multi-electrode intracortical microstimulation (ICMS) is essential for advancing neuroprosthetic technologies. We show that dual-electrode ICMS evokes distinct, predictable neuromodulatory effects that depend on (i) stimulation intensity, (ii) a neuron’s baseline responsiveness to single electrode input, and (iii) its proximity to the electrodes. Low and intermediate intensity dual-electrode ICMS amplifies neural activity compared to single-electrode ICMS, whereas high-intensity stimulation leads to attenuation, limiting net activation.
Open AccessSingle-Cell and Population-Level Neuromodulation Dynamics in Dual-Electrode Intracortical Stimulation
In neuroprosthetics, intracortical microstimulation (ICMS) recruits cortical networks to evoke brain responses and sensory perceptions. However, multi-electrode ICMS often generates suboptimal percepts compared to single-electrode ICMS, suggesting nonlinear neuromodulation rather than simple summation by multi-electrode ICMS. Yet, the factors and mechanisms underlying this modulation remain poorly understood. To investigate multi-electrode ICMS, we combined two-photon calcium imaging with a well-controlled dual-electrode ICMS in the mouse visual cortex to investigate how neurons integrate converging ICMS inputs at varying intensities. We found that stimulation intensity significantly shapes neuromodulation at both single-cell and population levels. Specifically, low intensities (5-7 µA) have a minimal effect on neural responses. At intermediate intensities (10-15 µA), we observed diverse, nonlinear bipolar modulation—both enhancement and attenuation—at the single-cell level. However, we achieved net enhancement at the population level. At higher intensities (15–20 µA), although the proportion of modulated neurons increased in both enhancement and attenuation directions, the net effect at the population level was neutral (zero modulation). Furthermore, neurons strongly responsive to single-electrode ICMS were more likely to be attenuated, while weaker responding cells exhibited enhanced modulation. The strongest neuromodulatory effects occur at intermediate spatial distances in between the two electrodes. Computational modeling based on spiking neural network composed of adaptive exponential integrate-and-field neurons implicated the importance of inhibitory network dynamics and network variability as key mechanisms. Our experimental data was used to train an advanced deep learning approach, which successfully predicted the neuromodulation patterns induced by dual-electrode ICMS. Our findings reveal intensity- and spatial-dependent rules of neuromodulation by ICMS, providing necessary insights to optimize multi-electrode ICMS for neuroprosthetic applications. Significance statement Understanding how cortical neurons integrate concurrent inputs from multi-electrode intracortical microstimulation (ICMS) is essential for advancing neuroprosthetic technologies. We show that dual-electrode ICMS evokes distinct, predictable neuromodulatory effects that depend on (i) stimulation intensity, (ii) a neuron’s baseline responsiveness to single electrode input, and (iii) its proximity to the electrodes. Low and intermediate intensity dual-electrode ICMS amplifies neural activity compared to single-electrode ICMS, whereas high-intensity stimulation leads to attenuation, limiting net activation.
- Open Access
- 17 April 2025
- Published by Wiley in Advanced Science
- Vol. 12 (22) , e2416771
Micro‐Coil Neuromodulation at Single‐Cell and Circuit Levels for Inhibiting Natural Neuroactivity, Neutralizing Electric Neural Excitation, and Suppressing Seizures
Micromagnetic stimulation (µMS) emerges as a complementary method for neuromodulation. Despite major advances in neural interface technology, there are limited options for neural inhibition. Here, a microchip‐based implantable micro‐coil device is presented to achieve high spatial precision for cortical inhibition. Cortical in vivo two‐photon imaging of spontaneous neural activity showed µMS reversibly suppressed single cells, and as µMS magnitude is increased, the suppressed cell population increased from 14% to 41%. At the circuit level, the average suppressed area is 0.05 mm 2 , seven times smaller than the activated area induced by micro‐electrode stimulation (µES). It is discovered that neurons responded more strongly to µMS than to µES, which is exploited to effectively neutralize the neural excitation induced by concurrently delivered strong µES (80 µA). Moreover, µMS mitigates hyperactive neural firing caused by pharmacologically induced seizures, reducing seizure amplitude by 54%. These findings underscore the potential of µMS as a precise, effective, and versatile tool for localized neuromodulation with an effect of opposite polarity from µES. Complementing optogenetic and electrical stimulation for multi‐functional neural interfaces, µMS holds promise as a unique neuroscience research tool and as a potential therapeutic intervention method for precisely suppressing hyperactive brain circuits.
- 17 April 2025
- Published by Wiley in Advanced Science
- Vol. 12 (22) , e2416771
Open AccessMicro‐Coil Neuromodulation at Single‐Cell and Circuit Levels for Inhibiting Natural Neuroactivity, Neutralizing Electric Neural Excitation, and Suppressing Seizures
Micromagnetic stimulation (µMS) emerges as a complementary method for neuromodulation. Despite major advances in neural interface technology, there are limited options for neural inhibition. Here, a microchip‐based implantable micro‐coil device is presented to achieve high spatial precision for cortical inhibition. Cortical in vivo two‐photon imaging of spontaneous neural activity showed µMS reversibly suppressed single cells, and as µMS magnitude is increased, the suppressed cell population increased from 14% to 41%. At the circuit level, the average suppressed area is 0.05 mm 2 , seven times smaller than the activated area induced by micro‐electrode stimulation (µES). It is discovered that neurons responded more strongly to µMS than to µES, which is exploited to effectively neutralize the neural excitation induced by concurrently delivered strong µES (80 µA). Moreover, µMS mitigates hyperactive neural firing caused by pharmacologically induced seizures, reducing seizure amplitude by 54%. These findings underscore the potential of µMS as a precise, effective, and versatile tool for localized neuromodulation with an effect of opposite polarity from µES. Complementing optogenetic and electrical stimulation for multi‐functional neural interfaces, µMS holds promise as a unique neuroscience research tool and as a potential therapeutic intervention method for precisely suppressing hyperactive brain circuits.
- Open Access
- 15 April 2025
- Published by Elsevier in Brain Stimulation
- Vol. 18 (3) , 885-896
Spatially and temporally mismatched blood flow and neuronal activity by high-intensity intracortical microstimulation
- 15 April 2025
- Published by Elsevier in Brain Stimulation
- Vol. 18 (3) , 885-896
Open AccessSpatially and temporally mismatched blood flow and neuronal activity by high-intensity intracortical microstimulation
- Open Access
- 10 February 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 227, 115143
MEMS micro-coils for magnetic neurostimulation
- 10 February 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 227, 115143
Open AccessMEMS micro-coils for magnetic neurostimulation
- Open Access
Hippocampal neuronal synchronization in the rat - Dissociation of perception from associative learning
Learning requires flexible switching between perceiving and encoding external sensory stimuli, making associations with representations already stored in memory (retrieval) and acting accordingly to adapt to the environment. Hippocampus is known to be central in creating mnemonic representations, but how it could support the integration of these processes of memory encoding and retrieval during repetitive learning experiences has remained unknown. In this study, we recorded local-field potentials (LFPs) from the dorsal hippocampus during classical trace eyeblink conditioning in rats. An auditory conditioned stimulus (CS) was followed by a periorbital shock-unconditioned stimulus (US). From the LFPs, we separated hippocampal oscillations that were linked with the variation in the trial-by-trial processing of the CS from those linked with the gradual learning of the CS-US association over daily sessions of training. Short latency transient theta and gamma band oscillations were associated with learning so that both the oscillation amplitudes (strength) and phase locking increased as a function of training. In contrast, long-latency sustained alpha and beta oscillations were associated with perception of CS. These data show divergent oscillatory neural signatures for perception and learning in hippocampal subfields.
Open AccessHippocampal neuronal synchronization in the rat - Dissociation of perception from associative learning
Learning requires flexible switching between perceiving and encoding external sensory stimuli, making associations with representations already stored in memory (retrieval) and acting accordingly to adapt to the environment. Hippocampus is known to be central in creating mnemonic representations, but how it could support the integration of these processes of memory encoding and retrieval during repetitive learning experiences has remained unknown. In this study, we recorded local-field potentials (LFPs) from the dorsal hippocampus during classical trace eyeblink conditioning in rats. An auditory conditioned stimulus (CS) was followed by a periorbital shock-unconditioned stimulus (US). From the LFPs, we separated hippocampal oscillations that were linked with the variation in the trial-by-trial processing of the CS from those linked with the gradual learning of the CS-US association over daily sessions of training. Short latency transient theta and gamma band oscillations were associated with learning so that both the oscillation amplitudes (strength) and phase locking increased as a function of training. In contrast, long-latency sustained alpha and beta oscillations were associated with perception of CS. These data show divergent oscillatory neural signatures for perception and learning in hippocampal subfields.