Vincenzo Monaco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vincenzo Monaco has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Aaron Dominguez
The Catholic University of America
256 shared publications - Alberto Ruiz Jimeno
Instituto de Física de Cantabria
256 shared publications - Alberto Zucchetta
INFN Sezione di Padova
256 shared publications - Amedeo Staiano
INFN sezione di Torino
256 shared publications - Arabella Martelli
Imperial College
256 shared publications - Benedikt Vormwald
CERN
256 shared publications
Latest Publications
- Open Access
- 8 June 2026
- Published by Wiley in Medical Physics
- Vol. 53 (6) , e70518
A coincidence‐based response matrix for correction of charge sharing spectral distortions in photon counting detectors
Background: Charge sharing between pixels distorts the count and spectral information of X‐ray photon counting detectors. Compensation methods for charge sharing effects are required to exploit the full potentiality of these detectors in medical diagnosis. Purpose: A statistical method is proposed to correct charge sharing effects in a pixellated photon counting detector by applying a spectral response matrix determined with a coincidence‐based acquisition. Methods: The technique is based on a preliminary calibration with a uniform irradiation and an arbitrary polychromatic spectrum, during which the number of coincidences between a pixel and its eight neighbours are collected for different combinations of energy bins. A coincidence‐based response matrix (CBRM) is determined and afterwards applied to correct other spectra acquired with the same detector and conventional multi‐comparator electronics. The technique was validated with Geant4 Monte Carlo simulations of a 1 mm thick CdTe detector and with data collected with a pixel hybrid detector consisting of a 300 thick silicon sensor readout by a Timepix4 chip. The effect of pulse pileup was not analyzed in this study. Results: The response matrix restores the spectral information with a performance comparable to analog charge summing (ACS) algorithms. For example, for a simulation of a spectrum from a 120 kV X‐ray tube attenuated by a solution of water and iodine and a CdTe detector with a pixel size of 200 µ m, the mean absolute percentage errors (MAPE) from the comparison of the corrections with an ideal spectrum are 20.0% for the CBRM method and 22.8% for ACS. The ACS method is more sensitive to electronic noise than the CBRM correction, thus requiring a higher noise discrimination threshold. For experimental acquisitions of monochromatic spectra with the silicon sensor, the mean values and standard deviations of Gaussian fits of the restored energy peaks provide results close to those from a clustering algorithm based on 3 3 pixel blocks. The MAPE value from the comparison of the CBRM correction and clustering distributions for a polychromatic spectrum of an X‐ray tube at 50 kV attenuated by an Ag solution is 6.2% It is also shown that a CBRM matrix determined with a fine division of the energy range can be adapted to match a lower number of energy bins employed for subsequent acquisitions without affecting the accuracy of the spectrum correction. A preliminary reconstruction of a nonuniform irradiation demonstrates the potentiality of the method to restore general spectral images. Conclusions: The proposed method allows the experimental determination of a response matrix which is independent of physics models or parameterizations and is realizable with a simple coincidence electronic circuit involving a limited number of pixels in a calibration stage. With respect to ACS techniques, the application of the response matrix requires only the number of counts collected with existing readout systems with multiple comparators, without introducing additional dead‐times during the acquisition.
- 8 June 2026
- Published by Wiley in Medical Physics
- Vol. 53 (6) , e70518
Open AccessA coincidence‐based response matrix for correction of charge sharing spectral distortions in photon counting detectors
Background: Charge sharing between pixels distorts the count and spectral information of X‐ray photon counting detectors. Compensation methods for charge sharing effects are required to exploit the full potentiality of these detectors in medical diagnosis. Purpose: A statistical method is proposed to correct charge sharing effects in a pixellated photon counting detector by applying a spectral response matrix determined with a coincidence‐based acquisition. Methods: The technique is based on a preliminary calibration with a uniform irradiation and an arbitrary polychromatic spectrum, during which the number of coincidences between a pixel and its eight neighbours are collected for different combinations of energy bins. A coincidence‐based response matrix (CBRM) is determined and afterwards applied to correct other spectra acquired with the same detector and conventional multi‐comparator electronics. The technique was validated with Geant4 Monte Carlo simulations of a 1 mm thick CdTe detector and with data collected with a pixel hybrid detector consisting of a 300 thick silicon sensor readout by a Timepix4 chip. The effect of pulse pileup was not analyzed in this study. Results: The response matrix restores the spectral information with a performance comparable to analog charge summing (ACS) algorithms. For example, for a simulation of a spectrum from a 120 kV X‐ray tube attenuated by a solution of water and iodine and a CdTe detector with a pixel size of 200 µ m, the mean absolute percentage errors (MAPE) from the comparison of the corrections with an ideal spectrum are 20.0% for the CBRM method and 22.8% for ACS. The ACS method is more sensitive to electronic noise than the CBRM correction, thus requiring a higher noise discrimination threshold. For experimental acquisitions of monochromatic spectra with the silicon sensor, the mean values and standard deviations of Gaussian fits of the restored energy peaks provide results close to those from a clustering algorithm based on 3 3 pixel blocks. The MAPE value from the comparison of the CBRM correction and clustering distributions for a polychromatic spectrum of an X‐ray tube at 50 kV attenuated by an Ag solution is 6.2% It is also shown that a CBRM matrix determined with a fine division of the energy range can be adapted to match a lower number of energy bins employed for subsequent acquisitions without affecting the accuracy of the spectrum correction. A preliminary reconstruction of a nonuniform irradiation demonstrates the potentiality of the method to restore general spectral images. Conclusions: The proposed method allows the experimental determination of a response matrix which is independent of physics models or parameterizations and is realizable with a simple coincidence electronic circuit involving a limited number of pixels in a calibration stage. With respect to ACS techniques, the application of the response matrix requires only the number of counts collected with existing readout systems with multiple comparators, without introducing additional dead‐times during the acquisition.
- 22 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (2) , 127-134
A Two-Prong Approach to the Simulation of DC-RSD: TCAD and SPICE
The DC-coupled Resistive Silicon Detectors (DC-RSD) are the evolution of the AC-coupled RSD (RSD) design, both based on the Low-Gain Avalanche Diode (LGAD) technology. The DC-RSD design concept intends to address a few known issues present in RSDs (e.g., baseline fluctuation, long tail-bipolar signals) while maintaining their advantages (e.g., signal spreading, 100% fill factor). The simulation of DC-RSD presents several unique challenges linked to the complex nature of its design and the large pixel size. The defining feature of DC-RSD, charge sharing over distances that can be as large as a millimetre, represents a formidable challenge for Technology-CAD (TCAD), the standard simulation tool. To circumvent this problem, we have developed a mixed-mode approach to the DC-RSD simulation, which exploits a combination of two simulation tools: TCAD and Spice. Thanks to this hybrid approach, it has been possible to demonstrate that, according to the simulation, the key features of the RSD, excellent timing and spatial resolutions (few tens of picoseconds and few microns), are maintained in the DC-RSD design. In this work, we present the developed models and methodology, mainly showing the results of device-level numerical simulation, which have been obtained with the state-of-the-art Synopsys Sentaurus TCAD suite of tools. Such results will provide all the necessary information for the first batch of DC-RSD produced by Fondazione Bruno Kessler (FBK) foundry in Trento, Italy.
- 22 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (2) , 127-134
A Two-Prong Approach to the Simulation of DC-RSD: TCAD and SPICE
The DC-coupled Resistive Silicon Detectors (DC-RSD) are the evolution of the AC-coupled RSD (RSD) design, both based on the Low-Gain Avalanche Diode (LGAD) technology. The DC-RSD design concept intends to address a few known issues present in RSDs (e.g., baseline fluctuation, long tail-bipolar signals) while maintaining their advantages (e.g., signal spreading, 100% fill factor). The simulation of DC-RSD presents several unique challenges linked to the complex nature of its design and the large pixel size. The defining feature of DC-RSD, charge sharing over distances that can be as large as a millimetre, represents a formidable challenge for Technology-CAD (TCAD), the standard simulation tool. To circumvent this problem, we have developed a mixed-mode approach to the DC-RSD simulation, which exploits a combination of two simulation tools: TCAD and Spice. Thanks to this hybrid approach, it has been possible to demonstrate that, according to the simulation, the key features of the RSD, excellent timing and spatial resolutions (few tens of picoseconds and few microns), are maintained in the DC-RSD design. In this work, we present the developed models and methodology, mainly showing the results of device-level numerical simulation, which have been obtained with the state-of-the-art Synopsys Sentaurus TCAD suite of tools. Such results will provide all the necessary information for the first batch of DC-RSD produced by Fondazione Bruno Kessler (FBK) foundry in Trento, Italy.
- Open Access
- 29 November 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (23) , 235009
Performance of LGAD strip detectors for particle counting of therapeutic proton beams
Objective . The performance of silicon detectors with moderate internal gain, named low-gain avalanche diodes (LGADs), was studied to investigate their capability to discriminate and count single beam particles at high fluxes, in view of future applications for beam characterization and on-line beam monitoring in proton therapy. Approach . Dedicated LGAD detectors with an active thickness of 55 μ m and segmented in 2 mm 2 strips were characterized at two Italian proton-therapy facilities, CNAO in Pavia and the Proton Therapy Center of Trento, with proton beams provided by a synchrotron and a cyclotron, respectively. Signals from single beam particles were discriminated against a threshold and counted. The number of proton pulses for fixed energies and different particle fluxes was compared with the charge collected by a compact ionization chamber, to infer the input particle rates. Main results . The counting inefficiency due to the overlap of nearby signals was less than 1% up to particle rates in one strip of 1 MHz, corresponding to a mean fluence rate on the strip of about 5 × 10 7 p/(cm 2 ·s). Count-loss correction algorithms based on the logic combination of signals from two neighboring strips allow to extend the maximum counting rate by one order of magnitude. The same algorithms give additional information on the fine time structure of the beam. Significance . The direct counting of the number of beam protons with segmented silicon detectors allows to overcome some limitations of gas detectors typically employed for beam characterization and beam monitoring in particle therapy, providing faster response times, higher sensitivity, and independence of the counts from the particle energy.
- 29 November 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (23) , 235009
Open AccessPerformance of LGAD strip detectors for particle counting of therapeutic proton beams
Objective . The performance of silicon detectors with moderate internal gain, named low-gain avalanche diodes (LGADs), was studied to investigate their capability to discriminate and count single beam particles at high fluxes, in view of future applications for beam characterization and on-line beam monitoring in proton therapy. Approach . Dedicated LGAD detectors with an active thickness of 55 μ m and segmented in 2 mm 2 strips were characterized at two Italian proton-therapy facilities, CNAO in Pavia and the Proton Therapy Center of Trento, with proton beams provided by a synchrotron and a cyclotron, respectively. Signals from single beam particles were discriminated against a threshold and counted. The number of proton pulses for fixed energies and different particle fluxes was compared with the charge collected by a compact ionization chamber, to infer the input particle rates. Main results . The counting inefficiency due to the overlap of nearby signals was less than 1% up to particle rates in one strip of 1 MHz, corresponding to a mean fluence rate on the strip of about 5 × 10 7 p/(cm 2 ·s). Count-loss correction algorithms based on the logic combination of signals from two neighboring strips allow to extend the maximum counting rate by one order of magnitude. The same algorithms give additional information on the fine time structure of the beam. Significance . The direct counting of the number of beam protons with segmented silicon detectors allows to overcome some limitations of gas detectors typically employed for beam characterization and beam monitoring in particle therapy, providing faster response times, higher sensitivity, and independence of the counts from the particle energy.
- Open Access
- 20 November 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (9) , 092004
First measurement of the forward rapidity gap distribution in collisions atFor the first time at LHC energies, the forward rapidity gap spectra from proton-lead collisions for both proton and lead dissociation processes are presented. The analysis is performed over 10.4 units of pseudorapidity at a center-of-mass energy per nucleon pair of , almost 300 times higher than in previous measurements of diffractive production in proton-nucleus collisions. For lead dissociation processes, which correspond to the pomeron-lead event topology, the epos-lhc generator predictions are a factor of 2 below the data, but the model gives a reasonable description of the rapidity gap spectrum shape. For the pomeron-proton topology, the epos-lhc, qgsjet ii, and hijing predictions are all at least a factor of 5 lower than the data. The latter effect might be explained by a significant contribution of ultraperipheral photoproduction events mimicking the signature of diffractive processes. These data may be of significant help in understanding the high energy limit of quantum chromodynamics and for modeling cosmic ray air showers.- 20 November 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (9) , 092004
Open AccessFirst measurement of the forward rapidity gap distribution in collisions atFor the first time at LHC energies, the forward rapidity gap spectra from proton-lead collisions for both proton and lead dissociation processes are presented. The analysis is performed over 10.4 units of pseudorapidity at a center-of-mass energy per nucleon pair of , almost 300 times higher than in previous measurements of diffractive production in proton-nucleus collisions. For lead dissociation processes, which correspond to the pomeron-lead event topology, the epos-lhc generator predictions are a factor of 2 below the data, but the model gives a reasonable description of the rapidity gap spectrum shape. For the pomeron-proton topology, the epos-lhc, qgsjet ii, and hijing predictions are all at least a factor of 5 lower than the data. The latter effect might be explained by a significant contribution of ultraperipheral photoproduction events mimicking the signature of diffractive processes. These data may be of significant help in understanding the high energy limit of quantum chromodynamics and for modeling cosmic ray air showers. - Open Access
- 6 September 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (5)
Measurement of differential cross sections for the production of a boson in association with jets in proton-proton collisions at- 6 September 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (5)
Open AccessMeasurement of differential cross sections for the production of a boson in association with jets in proton-proton collisions at - Open Access
- 20 July 2023
- Published by Elsevier in Physics Letters B
- Vol. 844
Two-particle azimuthal correlations in γp interactions using pPb collisions at- 20 July 2023
- Published by Elsevier in Physics Letters B
- Vol. 844
Open AccessTwo-particle azimuthal correlations in γp interactions using pPb collisions at - Open Access
- 28 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (23) , 12160
Fluence Beam Monitor for High-Intensity Particle Beams Based on a Multi-Gap Ionization Chamber and a Method for Ion Recombination Correction
This work presents the tests of a multi-gap detector (MGD), composed of three parallel-plate ionization chambers (ICs) with different gap widths, assembled to prove the capability of correcting for charge volume recombination which is expected to occur when high fluence rates are delivered. Such beam conditions occur with a compact accelerator for charged particle therapy developed to reduce the costs, to accomplish faster treatments and to exploit different beam delivery techniques and dose rates as needed, for example, for range modulation and FLASH irradiations, respectively. The MGD was tested with carbon ions at the Centro Nazionale di Adroterapia Oncologica (CNAO Pavia, Italy), and with protons in two different beam lines: at Bern University Hospital with continuous beams and at the Laboratori Nazionale del Sud (Catania, Italy) of the Italian National Center of Nuclear Physics (INFN) with pulsed beams. For each accelerator, we took measurements with different beam intensities (up to the maximum rate of ionization achievable) and changed the detector bias voltage (V) in order to study the charge collection efficiency. Charge recombination models were used to evaluate the expected collected charge and to measure the linearity of the rate of ionization with the beam fluence rate. A phenomenological approach was used to determine the collection efficiency (f1) of the chamber with thinnest gap from the relative efficiencies, f1/f2 and f1/f3, exploiting the condition that, for each measurement, the three chambers were exposed to the same rate of ionization. Results prove that two calibration curves can be determined and used to correct the online measurements for the charge losses in the ICs for recombination.
- 28 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (23) , 12160
Open AccessFluence Beam Monitor for High-Intensity Particle Beams Based on a Multi-Gap Ionization Chamber and a Method for Ion Recombination Correction
This work presents the tests of a multi-gap detector (MGD), composed of three parallel-plate ionization chambers (ICs) with different gap widths, assembled to prove the capability of correcting for charge volume recombination which is expected to occur when high fluence rates are delivered. Such beam conditions occur with a compact accelerator for charged particle therapy developed to reduce the costs, to accomplish faster treatments and to exploit different beam delivery techniques and dose rates as needed, for example, for range modulation and FLASH irradiations, respectively. The MGD was tested with carbon ions at the Centro Nazionale di Adroterapia Oncologica (CNAO Pavia, Italy), and with protons in two different beam lines: at Bern University Hospital with continuous beams and at the Laboratori Nazionale del Sud (Catania, Italy) of the Italian National Center of Nuclear Physics (INFN) with pulsed beams. For each accelerator, we took measurements with different beam intensities (up to the maximum rate of ionization achievable) and changed the detector bias voltage (V) in order to study the charge collection efficiency. Charge recombination models were used to evaluate the expected collected charge and to measure the linearity of the rate of ionization with the beam fluence rate. A phenomenological approach was used to determine the collection efficiency (f1) of the chamber with thinnest gap from the relative efficiencies, f1/f2 and f1/f3, exploiting the condition that, for each measurement, the three chambers were exposed to the same rate of ionization. Results prove that two calibration curves can be determined and used to correct the online measurements for the charge losses in the ICs for recombination.
- Open Access
- 28 August 2022
- Published by Elsevier in Physics Letters B
- Vol. 835
Nuclear modification of Y states in pPb collisions at- 28 August 2022
- Published by Elsevier in Physics Letters B
- Vol. 835
Open AccessNuclear modification of Y states in pPb collisions at