Xiuhua Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiuhua Sun has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Adam T. Woolley
Department of Chemistry and Biochemistry, Brigham Young University, Provo, USA
3 shared publications - Changlu Gao
School of Marine Science and Technology
3 shared publications Weichun Yang
Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA
3 shared publications- Dalong Li
State Key Laboratory of Urban-rural Water Resource and Environment, School of Marine Science and Technology, Harbin Institute of Technology, Weihai 264209, China
2 shared publications Changlu Gao
1 shared publication- Changlu Gao
School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai 264209, China
1 shared publication
Latest Publications
- 13 April 2022
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 285
Antifouling polysulfone membranes with an amphiphilic triblock additive
- 13 April 2022
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 285
Antifouling polysulfone membranes with an amphiphilic triblock additive
- Open Access
Zwitterionic Polysulfone Copolymer/Polysulfone Blended Ultrafiltration Membranes with Excellent Thermostability and Antifouling Properties
Membrane fouling has been one of the most important challenges in membrane separation operations. In this study, we report a facile strategy to prepare antifouling polysulfone (PSf) UF membranes by blending amphiphilic zwitterion polysulfone-co-sulfobetaine polysulfone (PSf-co-SBPSf) copolymer. The copolymer chemical structure was characterized by 1HNMR spectroscopy. The PSf/PSf-co-SBPSf blend membranes with various zwitterionic SBPSf segment contents exhibited better surface hydrophilicity and excellent antifouling ability compared to PSf and PSf/PEG membranes. The significant increase of both porosity and water permeance indicates that the PSf-co-SBPSf has a pore-forming effect. The pure water flux and flux recovery ratio of the PSf/PSf-co-SBPSf blend membranes were both remarked to improve 286.43 L/m2h and 92.26%, while bovine serum albumin (BSA) rejection remained at a high level (97.66%). More importantly, the water flux and BSA rejection see minimal variance after heat treatment, indicating excellent thermostability. Overall, the PSf/PSf-co-SBPSf blend membranes achieved a comprehensive performance of sustainable hydrophilic, high permeation flux, and remarkable antifouling ability, thus becoming a promising candidate in high-temperature separation application.
Open AccessZwitterionic Polysulfone Copolymer/Polysulfone Blended Ultrafiltration Membranes with Excellent Thermostability and Antifouling Properties
Membrane fouling has been one of the most important challenges in membrane separation operations. In this study, we report a facile strategy to prepare antifouling polysulfone (PSf) UF membranes by blending amphiphilic zwitterion polysulfone-co-sulfobetaine polysulfone (PSf-co-SBPSf) copolymer. The copolymer chemical structure was characterized by 1HNMR spectroscopy. The PSf/PSf-co-SBPSf blend membranes with various zwitterionic SBPSf segment contents exhibited better surface hydrophilicity and excellent antifouling ability compared to PSf and PSf/PEG membranes. The significant increase of both porosity and water permeance indicates that the PSf-co-SBPSf has a pore-forming effect. The pure water flux and flux recovery ratio of the PSf/PSf-co-SBPSf blend membranes were both remarked to improve 286.43 L/m2h and 92.26%, while bovine serum albumin (BSA) rejection remained at a high level (97.66%). More importantly, the water flux and BSA rejection see minimal variance after heat treatment, indicating excellent thermostability. Overall, the PSf/PSf-co-SBPSf blend membranes achieved a comprehensive performance of sustainable hydrophilic, high permeation flux, and remarkable antifouling ability, thus becoming a promising candidate in high-temperature separation application.
- 1 November 2020
- Published by Elsevier in Separation and Purification Technology
- Vol. 251, 117144
Improved water flux and antifouling properties of cardo poly(aryl ether ketone) ultrafiltration membrane by novel sulfobetaine polyimides additive
- 1 November 2020
- Published by Elsevier in Separation and Purification Technology
- Vol. 251, 117144
Improved water flux and antifouling properties of cardo poly(aryl ether ketone) ultrafiltration membrane by novel sulfobetaine polyimides additive
- 1 April 2018
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 102, 63-69
Creation of antifouling microarrays by photopolymerization of zwitterionic compounds for protein assay and cell patterning
- 1 April 2018
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 102, 63-69
Creation of antifouling microarrays by photopolymerization of zwitterionic compounds for protein assay and cell patterning
- 28 July 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 10 (19) , 2527-2533
Microdevices integrating affinity columns and capillary electrophoresis for multibiomarker analysis in human serum
Biomarkers in human body fluids have great potential for use in screening for diseases such as cancer and diabetes, diagnosis, determining the effectiveness of treatments, and detecting recurrence. Present 96-well immunoassay technology effectively analyzes large numbers of samples; however, this approach is more expensive and less time effective on single or a few samples. In contrast, microfluidic systems are well suited for assaying small numbers of specimens in a point-of-care setting, provided suitable procedures are developed to work within peak capacity constraints when analyzing complex mixtures like human blood serum. Here, we developed integrated microdevices with an affinity column and capillary electrophoresis channels to isolate and quantitate a panel of proteins in complex matrices. To form an affinity column, a thin film of a reactive polymer was photopolymerized in a microchannel, and four antibodies were covalently immobilized to it. The retained protein amounts were consistent from chip to chip, demonstrating reproducibility. Furthermore, the signals from four fluorescently labeled proteins captured on-column were in the same range after rinsing, indicating the column has little bias toward any of the four antibodies or their antigens. These affinity columns have been integrated with capillary electrophoresis separation, enabling us to simultaneously quantify four protein biomarkers in human blood serum in the low ng mL−1 range using either a calibration curve or standard addition. Our systems provide a fast, integrated and automated platform for multiple biomarker quantitation in complex media such as human blood serum.
- 28 July 2010
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 10 (19) , 2527-2533
Microdevices integrating affinity columns and capillary electrophoresis for multibiomarker analysis in human serum
Biomarkers in human body fluids have great potential for use in screening for diseases such as cancer and diabetes, diagnosis, determining the effectiveness of treatments, and detecting recurrence. Present 96-well immunoassay technology effectively analyzes large numbers of samples; however, this approach is more expensive and less time effective on single or a few samples. In contrast, microfluidic systems are well suited for assaying small numbers of specimens in a point-of-care setting, provided suitable procedures are developed to work within peak capacity constraints when analyzing complex mixtures like human blood serum. Here, we developed integrated microdevices with an affinity column and capillary electrophoresis channels to isolate and quantitate a panel of proteins in complex matrices. To form an affinity column, a thin film of a reactive polymer was photopolymerized in a microchannel, and four antibodies were covalently immobilized to it. The retained protein amounts were consistent from chip to chip, demonstrating reproducibility. Furthermore, the signals from four fluorescently labeled proteins captured on-column were in the same range after rinsing, indicating the column has little bias toward any of the four antibodies or their antigens. These affinity columns have been integrated with capillary electrophoresis separation, enabling us to simultaneously quantify four protein biomarkers in human blood serum in the low ng mL−1 range using either a calibration curve or standard addition. Our systems provide a fast, integrated and automated platform for multiple biomarker quantitation in complex media such as human blood serum.
- 19 December 2008
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (7) , 949-953
A general microchip surface modification approach using a spin-coated polymer resist film doped with hydroxypropyl cellulose
We have developed a simple and effective method for surface modification of polymer microchips by entrapping hydroxypropyl cellulose (HPC) in a spin-coated thin film on the surface. Poly(methyl methacrylate-8.5-methacrylic acid), a widely available commercial resist formulation, was utilized as a matrix for dissolving HPC and providing adherence to native polymer surfaces. Various amounts of HPC (0.1–2.0%) dissolved in the copolymer and spun on polymer surfaces were evaluated. The modified surfaces were characterized by contact angle measurement, X-ray photoelectron spectroscopy and atomic force microscopy. The developed method was applied on both poly(methyl methacrylate) and cyclic olefin copolymer microchips. A fluorescently labeled myoglobin digest, binary protein mixture, and human serum sample were all separated in these surface-modified polymer microdevices. Our work exhibits an easy and reliable way to achieve favorable biomolecular separation performance in polymer microchips.
- 19 December 2008
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (7) , 949-953
A general microchip surface modification approach using a spin-coated polymer resist film doped with hydroxypropyl cellulose
We have developed a simple and effective method for surface modification of polymer microchips by entrapping hydroxypropyl cellulose (HPC) in a spin-coated thin film on the surface. Poly(methyl methacrylate-8.5-methacrylic acid), a widely available commercial resist formulation, was utilized as a matrix for dissolving HPC and providing adherence to native polymer surfaces. Various amounts of HPC (0.1–2.0%) dissolved in the copolymer and spun on polymer surfaces were evaluated. The modified surfaces were characterized by contact angle measurement, X-ray photoelectron spectroscopy and atomic force microscopy. The developed method was applied on both poly(methyl methacrylate) and cyclic olefin copolymer microchips. A fluorescently labeled myoglobin digest, binary protein mixture, and human serum sample were all separated in these surface-modified polymer microdevices. Our work exhibits an easy and reliable way to achieve favorable biomolecular separation performance in polymer microchips.
- 15 May 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (13) , 5126-5130
Affinity Monolith-Integrated Poly(methyl methacrylate) Microchips for On-Line Protein Extraction and Capillary Electrophoresis
Immunoaffinity monolith pretreatment columns have been coupled with capillary electrophoresis separation in poly(methyl methacrylate) (PMMA) microchips. Microdevices were designed with eight reservoirs to enable the electrically controlled transport of selected analytes and solutions to carry out integrated immunoaffinity extraction and electrophoretic separation. The PMMA microdevices were fabricated reproducibly and with high fidelity by solvent imprinting and thermal bonding methods. Monoliths with epoxy groups for antibody immobilization were prepared by direct in situ photopolymerization of glycidyl methacrylate and ethylene glycol dimethacrylate in a porogenic solvent consisting of 70% 1-dodecanol and 30% cyclohexanol. Antifluorescein isothiocyanate was utilized as a model affinity group in the monoliths, and the immobilization process was optimized. A mean elution efficiency of 92% was achieved for the monolith-based extraction of fluorescein isothiocyanate (FITC)-tagged human serum albumin. FITC-tagged proteins were purified from a contaminant protein and then separated electrophoretically using these devices. The developed immunoaffinity column/capillary electrophoresis microdevices show great promise for combining sample pretreatment and separation in biomolecular analysis.
- 15 May 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (13) , 5126-5130
Affinity Monolith-Integrated Poly(methyl methacrylate) Microchips for On-Line Protein Extraction and Capillary Electrophoresis
Immunoaffinity monolith pretreatment columns have been coupled with capillary electrophoresis separation in poly(methyl methacrylate) (PMMA) microchips. Microdevices were designed with eight reservoirs to enable the electrically controlled transport of selected analytes and solutions to carry out integrated immunoaffinity extraction and electrophoretic separation. The PMMA microdevices were fabricated reproducibly and with high fidelity by solvent imprinting and thermal bonding methods. Monoliths with epoxy groups for antibody immobilization were prepared by direct in situ photopolymerization of glycidyl methacrylate and ethylene glycol dimethacrylate in a porogenic solvent consisting of 70% 1-dodecanol and 30% cyclohexanol. Antifluorescein isothiocyanate was utilized as a model affinity group in the monoliths, and the immobilization process was optimized. A mean elution efficiency of 92% was achieved for the monolith-based extraction of fluorescein isothiocyanate (FITC)-tagged human serum albumin. FITC-tagged proteins were purified from a contaminant protein and then separated electrophoretically using these devices. The developed immunoaffinity column/capillary electrophoresis microdevices show great promise for combining sample pretreatment and separation in biomolecular analysis.
- 2 March 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (8) , 2521-2525
On-Chip Amperometric Measurement of Quantal Catecholamine Release Using Transparent Indium Tin Oxide Electrodes
Carbon-fiber amperometry has been extensively used to monitor the time course of catecholamine release from cells as individual secretory granules discharge their contents during the process of quantal exocytosis, but microfabricated devices offer the promise of higher throughput. Here we report development of a microchip device that uses transparent indium tin oxide (ITO) electrodes to measure quantal exocytosis from cells in microfluidic channels. ITO films on a glass substrate were patterned as 20-μm-wide stripes using photolithography and wet etching and then coated with polylysine to facilitate cell adherence. Microfluidic channels (100 μm wide by 100 μm deep) were formed by molding poly(dimethylsiloxane) (PDMS) on photoresist and then reversibly sealing the PDMS slab to the ITO−glass substrate. Bovine adrenal chromaffin cells were loaded into the microfluidic channel and adhered to the ITO electrodes. Cells were stimulated to secrete by perfusing a depolarizing “high-K” solution while monitoring oxidation of catecholamines on the ITO electrode beneath the cell using amperometry. Amperometric spikes with charges ranging from 0.1 to 1.5 pC were recorded with a signal-to-noise ratio comparable to that of carbon-fiber electrodes. Further development of this approach will enable high-throughput measurement of quantal catecholamine release simultaneously with optical cell measurements such as fluorescence.
- 2 March 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (8) , 2521-2525
On-Chip Amperometric Measurement of Quantal Catecholamine Release Using Transparent Indium Tin Oxide Electrodes
Carbon-fiber amperometry has been extensively used to monitor the time course of catecholamine release from cells as individual secretory granules discharge their contents during the process of quantal exocytosis, but microfabricated devices offer the promise of higher throughput. Here we report development of a microchip device that uses transparent indium tin oxide (ITO) electrodes to measure quantal exocytosis from cells in microfluidic channels. ITO films on a glass substrate were patterned as 20-μm-wide stripes using photolithography and wet etching and then coated with polylysine to facilitate cell adherence. Microfluidic channels (100 μm wide by 100 μm deep) were formed by molding poly(dimethylsiloxane) (PDMS) on photoresist and then reversibly sealing the PDMS slab to the ITO−glass substrate. Bovine adrenal chromaffin cells were loaded into the microfluidic channel and adhered to the ITO electrodes. Cells were stimulated to secrete by perfusing a depolarizing “high-K” solution while monitoring oxidation of catecholamines on the ITO electrode beneath the cell using amperometry. Amperometric spikes with charges ranging from 0.1 to 1.5 pC were recorded with a signal-to-noise ratio comparable to that of carbon-fiber electrodes. Further development of this approach will enable high-throughput measurement of quantal catecholamine release simultaneously with optical cell measurements such as fluorescence.