Miklos Lenner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Miklos Lenner has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Andreas Frank
ABB Switzerland Ltd, Switzerland
2 shared publications- Klaus Bohnert
Corporate Research, ABB Switzerland Ltd, Baden-Daettwil, AG Switzerland
2 shared publications - Lin Yang
School of Information Science and Engineering, Hebei University of Science and Technology, Shijiazhuang, China
2 shared publications - Axel Kramer
University Medicine Greifswald
1 shared publication - Christian Spielmann
Friedrich Schiller University Jena
1 shared publication Christof Bernhard
ABB Switzerland Ltd, Corporate Research Center, 5405 Baden, Switzerland
1 shared publication
Latest Publications
- 23 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (8) , 4080-4086
Single-Element Ultrasonic Transducer for Non-Invasive Measurements
A simple, passive, single-element ultrasonic transducer is proposed for non-invasive measurements. Operating the transducer at different resonant modes allows the adaptation of the emitted sound pattern to various requirements. The emitted sound field is simulated and experimentally characterized. We demonstrate the suitability of the transducer prototype for non-invasive continuous level measurement in laboratory as well as field environment over an extended level-and temperature range. The measured performance fulfils typical requirements for invasive level sensors. The versatility of the transducer enables its application in a wide range of non-invasive measurements.
- 23 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (8) , 4080-4086
Single-Element Ultrasonic Transducer for Non-Invasive Measurements
A simple, passive, single-element ultrasonic transducer is proposed for non-invasive measurements. Operating the transducer at different resonant modes allows the adaptation of the emitted sound pattern to various requirements. The emitted sound field is simulated and experimentally characterized. We demonstrate the suitability of the transducer prototype for non-invasive continuous level measurement in laboratory as well as field environment over an extended level-and temperature range. The measured performance fulfils typical requirements for invasive level sensors. The versatility of the transducer enables its application in a wide range of non-invasive measurements.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Industrial gas analytics using a compact ultraviolet laser
Ultraviolet light in the wavelength range between 200 nm and 240 nm is of great interest for spectroscopic gas analytics. Particularly, for industrial applications, optical gas analyzers based on this spectral range are promising for combustion gas and natural gas analytics but require availability of suitable robust, compact and low-cost light sources. We have demonstrated a gas analyzer using a compact solid-state laser module which emits wavelengths near 219 nm and which offers significant advantages compared with conventional light sources. The key characteristics of the laser module are outlined in the paper and the integration of the laser into a gas analyzer prototype is described. In a simple absorption setup, using the example of hydrogen sulfide as analyte, we demonstrate a detection limit of 0.02 ppm•m (3 σ, 50 s average, 1 Hz sampling rate). The properties of the laser having a small footprint, low supply voltage, and low power consumption are key advantages for the integration into future robust, low-cost, industrial products.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Industrial gas analytics using a compact ultraviolet laser
Ultraviolet light in the wavelength range between 200 nm and 240 nm is of great interest for spectroscopic gas analytics. Particularly, for industrial applications, optical gas analyzers based on this spectral range are promising for combustion gas and natural gas analytics but require availability of suitable robust, compact and low-cost light sources. We have demonstrated a gas analyzer using a compact solid-state laser module which emits wavelengths near 219 nm and which offers significant advantages compared with conventional light sources. The key characteristics of the laser module are outlined in the paper and the integration of the laser into a gas analyzer prototype is described. In a simple absorption setup, using the example of hydrogen sulfide as analyte, we demonstrate a detection limit of 0.02 ppm•m (3 σ, 50 s average, 1 Hz sampling rate). The properties of the laser having a small footprint, low supply voltage, and low power consumption are key advantages for the integration into future robust, low-cost, industrial products.
- 1 January 2017
- Published by Optica Publishing Group
- p. SeW1E.3
Long-term reliability of fiber-optic sensor components in harsh industrial environments
Applications of fiber-optic technology in harsh industrial environments require high level of reliability of the components. Comprehensive accelerated life tests demonstrated excellent long-term performance of reliability-critical optical components.
- 1 January 2017
- Published by Optica Publishing Group
- p. SeW1E.3
Long-term reliability of fiber-optic sensor components in harsh industrial environments
Applications of fiber-optic technology in harsh industrial environments require high level of reliability of the components. Comprehensive accelerated life tests demonstrated excellent long-term performance of reliability-critical optical components.
- 1 January 2014
- Published by Optica Publishing Group
- p. SeW3C.6
Long-term reliability of semiconductor light sources for fiber-optic current sensors
The wavelength stability of the light source is crucial for the long-term accuracy of fiber-optic current sensors. Accelerated life tests over extended time periods demonstrated excellent reliability of 1310 nm superluminescent light emitting diodes.
- 1 January 2014
- Published by Optica Publishing Group
- p. SeW3C.6
Long-term reliability of semiconductor light sources for fiber-optic current sensors
The wavelength stability of the light source is crucial for the long-term accuracy of fiber-optic current sensors. Accelerated life tests over extended time periods demonstrated excellent reliability of 1310 nm superluminescent light emitting diodes.
- 10 June 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (17) , 3532-3539
Protective materials for subpicosecond Ti:sapphire lasers
The high intensities provided by short-pulse Ti:sapphire laser systems call for the utilization of appropriate eye-protecting materials. We summarize the representative results of our characterization measurements on optical filters employed for laser radiation protection. Physical effects are discussed that influence the transmission (and thus the protective properties) of the investigated materials. Potential hazard factors have been recognized and characterized. We make recommendations to the extension of the current characterization methods and illustrate the acquired information in the form of operation charts.
- 10 June 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (17) , 3532-3539
Protective materials for subpicosecond Ti:sapphire lasers
The high intensities provided by short-pulse Ti:sapphire laser systems call for the utilization of appropriate eye-protecting materials. We summarize the representative results of our characterization measurements on optical filters employed for laser radiation protection. Physical effects are discussed that influence the transmission (and thus the protective properties) of the investigated materials. Potential hazard factors have been recognized and characterized. We make recommendations to the extension of the current characterization methods and illustrate the acquired information in the form of operation charts.