Kevin G. Fissum
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kevin G. Fissum has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
M. Lundin
MAX IV Laboratory Lund University SE-221 00 Lund Sweden
35 shared publicationsA. Saha
Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606, USA
31 shared publicationsL. Isaksson
MAX IV Laboratory Lund University SE-221 00 Lund Sweden
31 shared publicationsK. Hansen
MAX IV Laboratory Lund University SE-221 00 Lund Sweden
30 shared publicationsR. Michaels
Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606, USA
30 shared publicationsC. W. de Jager
29 shared publications
Latest Publications
- Open Access
- 18 December 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1084
The application of VMM3A readout for Multi-Grid neutron detectors
- 18 December 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1084
Open AccessThe application of VMM3A readout for Multi-Grid neutron detectors
- Open Access
- 23 February 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1062
Light-yield response of liquid scintillators using 2–6 MeV tagged neutrons
- 23 February 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1062
Open AccessLight-yield response of liquid scintillators using 2–6 MeV tagged neutrons
- 18 January 2023
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 24 (3-4) , 281-287
Development of a Pelletron-based compact neutron source
The Applied Nuclear Physics Group at Lund University is constructing a prototype CANS (Compact Accelerator-driven Neutron Source). The CANS is based around a 3 MV, single-ended, Pelletron accelerator, which is used to impinge a 2.8 MeV deuterium beam into a beryllium target. The anticipated neutron production will be on the order of 1010 n/s in 4π sr. A further upgrade to the ion source of the Pelletron is expected to increase neutron production to 1011 n/s. Neutron energies will be up to 9 MeV with peak emission at ∼5 MeV. Shielding and moderation will be provided by a large water tank surrounding the target, with three exit ports to allow neutrons of different energies to be directed to experiments. The design is supported by simulation results which predict fast-neutron fluxes of 9×104 to 5×106 n/cm2/s, and thermal-neutron fluxes of 1×104 to 5×104 n/cm2/s to be readily obtainable with a 10 µA deuteron beam.
- 18 January 2023
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 24 (3-4) , 281-287
Development of a Pelletron-based compact neutron source
The Applied Nuclear Physics Group at Lund University is constructing a prototype CANS (Compact Accelerator-driven Neutron Source). The CANS is based around a 3 MV, single-ended, Pelletron accelerator, which is used to impinge a 2.8 MeV deuterium beam into a beryllium target. The anticipated neutron production will be on the order of 1010 n/s in 4π sr. A further upgrade to the ion source of the Pelletron is expected to increase neutron production to 1011 n/s. Neutron energies will be up to 9 MeV with peak emission at ∼5 MeV. Shielding and moderation will be provided by a large water tank surrounding the target, with three exit ports to allow neutrons of different energies to be directed to experiments. The design is supported by simulation results which predict fast-neutron fluxes of 9×104 to 5×106 n/cm2/s, and thermal-neutron fluxes of 1×104 to 5×104 n/cm2/s to be readily obtainable with a 10 µA deuteron beam.
- Open Access
- 1 January 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1023
GEANT4-based calibration of an organic liquid scintillator
- 1 January 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1023
Open AccessGEANT4-based calibration of an organic liquid scintillator
- Open Access
- 6 July 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (7) , 072901
Vanadium-based neutron beam monitor
A prototype quasiparasitic thermal neutron beam monitor based on isotropic neutron scattering from a thin natural vanadium foil and standard proportional counters is conceptualized, designed, simulated, calibrated, and commissioned. The European Spallation Source designed to deliver the highest integrated neutron flux originating from a pulsed source is currently under construction in Lund, Sweden. The effort to investigate a vanadium-based neutron beam monitor was triggered by a list of requirements for beam monitors permanently placed in the ESS neutron beams in order to provide reliable monitoring at complex beam lines: low attenuation, linear response over a wide range of neutron fluxes, near to constant efficiency for neutron wavelengths in a range of 0.6–10 Å, calibration stability and the possibility to place the system in vacuum are all desirable characteristics. The scattering-based prototype, employing a natural vanadium foil and standard proportional counters, was investigated at the V17 and V20 neutron beam lines of the Helmholtz-Zentrum in Berlin, Germany, in several different geometrical configurations of the proportional counters around the foil. Response linearity is successfully demonstrated for foil thicknesses ranging from 0.04 mm to 3.15 mm. Attenuation lower than 1% for thermal neutrons is demonstrated for the 0.04 mm and 0.125 mm foils. The geometries used for the experiment were simulated allowing for absolute flux calibration and establishing the possible range of efficiencies for various designs of the prototype. The operational flux limits for the beam monitor prototype were established as a dependency of the background radiation and prototype geometry. The herein demonstrated prototype monitors can be employed for neutron intensities ranging from .- 6 July 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (7) , 072901
Open AccessVanadium-based neutron beam monitor
A prototype quasiparasitic thermal neutron beam monitor based on isotropic neutron scattering from a thin natural vanadium foil and standard proportional counters is conceptualized, designed, simulated, calibrated, and commissioned. The European Spallation Source designed to deliver the highest integrated neutron flux originating from a pulsed source is currently under construction in Lund, Sweden. The effort to investigate a vanadium-based neutron beam monitor was triggered by a list of requirements for beam monitors permanently placed in the ESS neutron beams in order to provide reliable monitoring at complex beam lines: low attenuation, linear response over a wide range of neutron fluxes, near to constant efficiency for neutron wavelengths in a range of 0.6–10 Å, calibration stability and the possibility to place the system in vacuum are all desirable characteristics. The scattering-based prototype, employing a natural vanadium foil and standard proportional counters, was investigated at the V17 and V20 neutron beam lines of the Helmholtz-Zentrum in Berlin, Germany, in several different geometrical configurations of the proportional counters around the foil. Response linearity is successfully demonstrated for foil thicknesses ranging from 0.04 mm to 3.15 mm. Attenuation lower than 1% for thermal neutrons is demonstrated for the 0.04 mm and 0.125 mm foils. The geometries used for the experiment were simulated allowing for absolute flux calibration and establishing the possible range of efficiencies for various designs of the prototype. The operational flux limits for the beam monitor prototype were established as a dependency of the background radiation and prototype geometry. The herein demonstrated prototype monitors can be employed for neutron intensities ranging from . - Open Access
Response of a Li-glass/multi-anode photomultiplier detector to focused proton and deuteron beams
The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 by 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel on an event-by-event basis. Several pixels generally registered considerable signals at each beam location. The number of pixels above set thresholds were investigated, with the optimization of the single-hit efficiency over the largest possible area as the goal. For both beams, at a threshold of ~50% of the mean of the full-deposition peak, ~80% of the events were registered in a single pixel, resulting in an effective position resolution of ~5 mm in X and Y.
Open AccessResponse of a Li-glass/multi-anode photomultiplier detector to focused proton and deuteron beams
The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 by 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel on an event-by-event basis. Several pixels generally registered considerable signals at each beam location. The number of pixels above set thresholds were investigated, with the optimization of the single-hit efficiency over the largest possible area as the goal. For both beams, at a threshold of ~50% of the mean of the full-deposition peak, ~80% of the events were registered in a single pixel, resulting in an effective position resolution of ~5 mm in X and Y.