Omid Zarini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Omid Zarini has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Ulrich Schramm
Helmholtz-Zentrum Dresden-Rossendorf
10 shared publications - Jurjen Couperus Cabadağ
Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany
9 shared publications - Alexander Debus
Helmholtz-Zentrum Dresden-Rossendorf
5 shared publications A. Köhler
Institute of Radiation Physics, Helmholtz-Zentrum Dresden - Rossendorf, Bautzner Landstrasse 400, 01328, Dresden, Germany
4 shared publications- Alexander Köhler
Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328 Dresden, Germany
4 shared publications - Arie Irman
Helmholtz-Zentrum Dresden-Rossendorf
4 shared publications
Latest Publications
- Open Access
- 20 January 2022
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 25 (1) , 012801
Multioctave high-dynamic range optical spectrometer for single-pulse, longitudinal characterization of ultrashort electron bunches
We present design and realization of an ultrabroadband optical spectrometer capable of measuring the spectral intensity of multioctave-spanning light sources on a single-pulse basis with a dynamic range of up to eight orders of magnitude. The instrument is optimized for the characterization of the temporal structure of femtosecond long electron bunches by analyzing the emitted coherent transition radiation spectra. The spectrometer operates within the spectral range of 250 nm to , corresponding to 5.5 optical octaves. This is achieved by dividing the signal beam into three spectral groups, each analyzed by a dedicated spectrometer and detector unit. The complete instrument was characterized with regard to wavelength, relative spectral sensitivity, and absolute photometric sensitivity, always accounting for the light polarization and comparing different calibration methods. Finally, the capability of the spectrometer is demonstrated with a coherent transition radiation measurement of a laser wakefield accelerated electron bunch, enabling to determine temporal pulse structures at unprecedented resolution.- 20 January 2022
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 25 (1) , 012801
Open AccessMultioctave high-dynamic range optical spectrometer for single-pulse, longitudinal characterization of ultrashort electron bunches
We present design and realization of an ultrabroadband optical spectrometer capable of measuring the spectral intensity of multioctave-spanning light sources on a single-pulse basis with a dynamic range of up to eight orders of magnitude. The instrument is optimized for the characterization of the temporal structure of femtosecond long electron bunches by analyzing the emitted coherent transition radiation spectra. The spectrometer operates within the spectral range of 250 nm to , corresponding to 5.5 optical octaves. This is achieved by dividing the signal beam into three spectral groups, each analyzed by a dedicated spectrometer and detector unit. The complete instrument was characterized with regard to wavelength, relative spectral sensitivity, and absolute photometric sensitivity, always accounting for the light polarization and comparing different calibration methods. Finally, the capability of the spectrometer is demonstrated with a coherent transition radiation measurement of a laser wakefield accelerated electron bunch, enabling to determine temporal pulse structures at unprecedented resolution. - Open Access
- 2 July 2020
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 125 (1) , 014801
Coherent Optical Signatures of Electron Microbunching in Laser-Driven Plasma Accelerators
We report observations of coherent optical transition radiation interferometry (COTRI) patterns generated by microbunched electrons as they emerge from a laser-driven plasma accelerator. The divergence of the microbunched portion of electrons, deduced by comparison to a COTRI model, is smaller than the ensemble beam divergence, while the radius of the microbunched beam, obtained from COTR images on the same shot, is . The combined results show that the microbunched distribution has estimated transverse normalized emittance .- 2 July 2020
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 125 (1) , 014801
Open AccessCoherent Optical Signatures of Electron Microbunching in Laser-Driven Plasma Accelerators
We report observations of coherent optical transition radiation interferometry (COTRI) patterns generated by microbunched electrons as they emerge from a laser-driven plasma accelerator. The divergence of the microbunched portion of electrons, deduced by comparison to a COTRI model, is smaller than the ensemble beam divergence, while the radius of the microbunched beam, obtained from COTR images on the same shot, is . The combined results show that the microbunched distribution has estimated transverse normalized emittance . - 1 September 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (9) , 093303
Calibration and cross-laboratory implementation of scintillating screens for electron bunch charge determination
We revise the calibration of scintillating screens commonly used to detect relativistic electron beams with low average current, e.g., from laser-plasma accelerators, based on new and expanded measurements that include higher charge density and different types of screens than previous work [Buck et al., Rev. Sci. Instrum. 81, 033301 (2010)]. Electron peak charge densities up to 10 nC/mm2 were provided by focused picosecond-long electron beams delivered by the Electron Linac for beams with high Brilliance and low Emittance (ELBE) at the Helmholtz-Zentrum Dresden-Rossendorf. At low charge densities, a linear scintillation response was found, followed by the onset of saturation in the range of nC/mm2. The absolute calibration factor (photons/sr/pC) in this linear regime was measured to be almost a factor of 2 lower than that reported by Buck et al. retrospectively implying a higher charge in the charge measurements performed with the former calibration. A good agreement was found with the results provided by Glinec et al. [Rev. Sci. Instrum. 77, 103301 (2006)]. Furthermore long-term irradiation tests with an integrated dose of approximately 50 nC/mm2 indicate a significant decrease of the scintillation efficiency over time. Finally, in order to enable the transfer of the absolute calibration between laboratories, a new constant reference light source has been developed.
- 1 September 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (9) , 093303
Calibration and cross-laboratory implementation of scintillating screens for electron bunch charge determination
We revise the calibration of scintillating screens commonly used to detect relativistic electron beams with low average current, e.g., from laser-plasma accelerators, based on new and expanded measurements that include higher charge density and different types of screens than previous work [Buck et al., Rev. Sci. Instrum. 81, 033301 (2010)]. Electron peak charge densities up to 10 nC/mm2 were provided by focused picosecond-long electron beams delivered by the Electron Linac for beams with high Brilliance and low Emittance (ELBE) at the Helmholtz-Zentrum Dresden-Rossendorf. At low charge densities, a linear scintillation response was found, followed by the onset of saturation in the range of nC/mm2. The absolute calibration factor (photons/sr/pC) in this linear regime was measured to be almost a factor of 2 lower than that reported by Buck et al. retrospectively implying a higher charge in the charge measurements performed with the former calibration. A good agreement was found with the results provided by Glinec et al. [Rev. Sci. Instrum. 77, 103301 (2006)]. Furthermore long-term irradiation tests with an integrated dose of approximately 50 nC/mm2 indicate a significant decrease of the scintillation efficiency over time. Finally, in order to enable the transfer of the absolute calibration between laboratories, a new constant reference light source has been developed.
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Advanced Methods for Temporal Reconstruction of Modulated Electron Bunches
We describe optimizations of phase-retrieval algorithms for the reconstruction of the temporal structure of highly modulated electron bunches from coherent transition radiation (CTR) spectra. Synthetic data is used to quantitatively analyze capabilities and limitations of the approach taking into account realistic bandwidth constraints of ultra-broadband spectrometers. Established algorithms are combined with information from independent channels as charge calibrated electron spectra and absolute intensity calibration of the spectrometer. With this set of data, in principle available in experiments, we demonstrate a promising fidelity for the detailed analysis of substructured laser wakefield accelerated electron bunches.
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Advanced Methods for Temporal Reconstruction of Modulated Electron Bunches
We describe optimizations of phase-retrieval algorithms for the reconstruction of the temporal structure of highly modulated electron bunches from coherent transition radiation (CTR) spectra. Synthetic data is used to quantitatively analyze capabilities and limitations of the approach taking into account realistic bandwidth constraints of ultra-broadband spectrometers. Established algorithms are combined with information from independent channels as charge calibrated electron spectra and absolute intensity calibration of the spectrometer. With this set of data, in principle available in experiments, we demonstrate a promising fidelity for the detailed analysis of substructured laser wakefield accelerated electron bunches.
- 5 March 2018
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 60 (4) , 044015
Improved performance of laser wakefield acceleration by tailored self-truncated ionization injection
We report on tailoring ionization-induced injection in laser wakefield acceleration so that the electron injection process is self-truncating following the evolution of the plasma bubble. Robust generation of high-quality electron beams with shot-to-shot fluctuations of the beam parameters better than 10% is presented in detail. As a novelty, the scheme was found to enable well-controlled yet simple tuning of the injected charge while preserving acceleration conditions and beam quality. Quasi-monoenergetic electron beams at several 100 MeV energy and 15% relative energy spread were routinely demonstrated with a total charge of the monoenergetic feature reaching 0.5 nC. Finally these unique beam parameters, suggesting unprecedented peak currents of several 10 kA, are systematically related to published data on alternative injection schemes.
- 5 March 2018
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 60 (4) , 044015
Improved performance of laser wakefield acceleration by tailored self-truncated ionization injection
We report on tailoring ionization-induced injection in laser wakefield acceleration so that the electron injection process is self-truncating following the evolution of the plasma bubble. Robust generation of high-quality electron beams with shot-to-shot fluctuations of the beam parameters better than 10% is presented in detail. As a novelty, the scheme was found to enable well-controlled yet simple tuning of the injected charge while preserving acceleration conditions and beam quality. Quasi-monoenergetic electron beams at several 100 MeV energy and 15% relative energy spread were routinely demonstrated with a total charge of the monoenergetic feature reaching 0.5 nC. Finally these unique beam parameters, suggesting unprecedented peak currents of several 10 kA, are systematically related to published data on alternative injection schemes.
- Open Access
- 23 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1398
Making spectral shape measurements in inverse Compton scattering a tool for advanced diagnostic applications
Interaction of relativistic electron beams with high power lasers can both serve as a secondary light source and as a novel diagnostic tool for various beam parameters. For both applications, it is important to understand the dynamics of the inverse Compton scattering mechanism and the dependence of the scattered light’s spectral properties on the interacting laser and electron beam parameters. Measurements are easily misinterpreted due to the complex interplay of the interaction parameters. Here we report the potential of inverse Compton scattering as an advanced diagnostic tool by investigating two of the most influential interaction parameters, namely the laser intensity and the electron beam emittance. Established scaling laws for the spectral bandwidth and redshift of the mean scattered photon energy are refined. This allows for a quantitatively well matching prediction of the spectral shape. Driving the interaction to a nonlinear regime, we spectrally resolve the rise of higher harmonic radiation with increasing laser intensity. Unprecedented agreement with 3D radiation simulations is found, showing the good control and characterization of the interaction. The findings advance the interpretation of inverse Compton scattering measurements into a diagnostic tool for electron beams from laser plasma acceleration.
- 23 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1398
Open AccessMaking spectral shape measurements in inverse Compton scattering a tool for advanced diagnostic applications
Interaction of relativistic electron beams with high power lasers can both serve as a secondary light source and as a novel diagnostic tool for various beam parameters. For both applications, it is important to understand the dynamics of the inverse Compton scattering mechanism and the dependence of the scattered light’s spectral properties on the interacting laser and electron beam parameters. Measurements are easily misinterpreted due to the complex interplay of the interaction parameters. Here we report the potential of inverse Compton scattering as an advanced diagnostic tool by investigating two of the most influential interaction parameters, namely the laser intensity and the electron beam emittance. Established scaling laws for the spectral bandwidth and redshift of the mean scattered photon energy are refined. This allows for a quantitatively well matching prediction of the spectral shape. Driving the interaction to a nonlinear regime, we spectrally resolve the rise of higher harmonic radiation with increasing laser intensity. Unprecedented agreement with 3D radiation simulations is found, showing the good control and characterization of the interaction. The findings advance the interpretation of inverse Compton scattering measurements into a diagnostic tool for electron beams from laser plasma acceleration.
- Top Cited PapersOpen Access
- 8 September 2017
- Published by Springer Nature in Nature Communications
- Vol. 8 (1) , 1-7
Demonstration of a beam loaded nanocoulomb-class laser wakefield accelerator
Laser-plasma wakefield accelerators have seen tremendous progress, now capable of producing quasi-monoenergetic electron beams in the GeV energy range with few-femtoseconds bunch duration. Scaling these accelerators to the nanocoulomb range would yield hundreds of kiloamperes peak current and stimulate the next generation of radiation sources covering high-field THz, high-brightness X-ray and γ-ray sources, compact free-electron lasers and laboratory-size beam-driven plasma accelerators. However, accelerators generating such currents operate in the beam loading regime where the accelerating field is strongly modified by the self-fields of the injected bunch, potentially deteriorating key beam parameters. Here we demonstrate that, if appropriately controlled, the beam loading effect can be employed to improve the accelerator’s performance. Self-truncated ionization injection enables loading of unprecedented charges of ∼0.5 nC within a mono-energetic peak. As the energy balance is reached, we show that the accelerator operates at the theoretically predicted optimal loading condition and the final energy spread is minimized.
- 8 September 2017
- Published by Springer Nature in Nature Communications
- Vol. 8 (1) , 1-7
Top Cited PapersOpen AccessDemonstration of a beam loaded nanocoulomb-class laser wakefield accelerator
Laser-plasma wakefield accelerators have seen tremendous progress, now capable of producing quasi-monoenergetic electron beams in the GeV energy range with few-femtoseconds bunch duration. Scaling these accelerators to the nanocoulomb range would yield hundreds of kiloamperes peak current and stimulate the next generation of radiation sources covering high-field THz, high-brightness X-ray and γ-ray sources, compact free-electron lasers and laboratory-size beam-driven plasma accelerators. However, accelerators generating such currents operate in the beam loading regime where the accelerating field is strongly modified by the self-fields of the injected bunch, potentially deteriorating key beam parameters. Here we demonstrate that, if appropriately controlled, the beam loading effect can be employed to improve the accelerator’s performance. Self-truncated ionization injection enables loading of unprecedented charges of ∼0.5 nC within a mono-energetic peak. As the energy balance is reached, we show that the accelerator operates at the theoretically predicted optimal loading condition and the final energy spread is minimized.
- Open Access
- 20 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 874 (1) , 012028
First results with the novel petawatt laser acceleration facility in Dresden
We report on first commissioning results of the DRACO Petawatt ultra-short pulse laser system implemented at the ELBE center for high power radiation sources of Helmholtz-Zentrum Dresden-Rossendorf. Key parameters of the laser system essential for efficient and reproducible performance of plasma accelerators are presented and discussed with the demonstration of 40 MeV proton acceleration under TNSA conditions as well as peaked electron spectra with unprecedented bunch charge in the 0.5 nC range.
- 20 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 874 (1) , 012028
Open AccessFirst results with the novel petawatt laser acceleration facility in Dresden
We report on first commissioning results of the DRACO Petawatt ultra-short pulse laser system implemented at the ELBE center for high power radiation sources of Helmholtz-Zentrum Dresden-Rossendorf. Key parameters of the laser system essential for efficient and reproducible performance of plasma accelerators are presented and discussed with the demonstration of 40 MeV proton acceleration under TNSA conditions as well as peaked electron spectra with unprecedented bunch charge in the 0.5 nC range.