Jeremy M. Manheim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jeremy M. Manheim has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Dylan T. Holden
Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
2 shared publications - Eric T. Dziekonski
Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
2 shared publications - Hilkka Kenttämaa
Department of Chemistry Purdue University West Lafayette Indiana USA
2 shared publications - Kiran Iyer
Merck & Co., Inc. Analytical Research and Development Rahway NJ 07065 USA
2 shared publications Mark Romanczyk
2 shared publications- MyPhuong T. Le
Purdue University Department of Chemistry West Lafayette IN 47907 USA
2 shared publications
Latest Publications
- Open Access
- 24 January 2024
- Published by Wiley in Angewandte Chemie
- Vol. 136 (9)
Two‐Dimensional Tandem Mass Spectrometry for Biopolymer Structural Analysis
Biopolymer analysis, including proteomics and glycomics, relies heavily on the use of mass spectrometry for structural elucidation, including sequence determination. Novel methods to improve sample workup, instrument performance, and data analysis continue to be developed to address shortcomings associated with sample preparation, analysis time, data quality, and data interpretation. Here, we present a new method that couples in‐source collision‐induced dissociation (IS‐CID) with two‐dimensional tandem mass spectrometry (2D MS/MS) as a way to simplify proteomics and glycomics workflows while also providing additional insight into analyte structures over traditional MS/MS experiments. Specifically, IS‐CID is employed as a gas‐phase digestion method, i.e., to break down intact full‐length polysaccharide or peptide ions prior to mass analysis. The resulting mixtures of oligomeric ions are analyzed by 2D‐MS/MS, a technique that allows association of product ions with their precursor ions without isolation of the latter. A novel data analysis strategy is introduced to leverage the second dimension of 2D MS/MS spectra, in which stairstep patterns, representing outputs of a molecule's MSn scans, are extracted for structural interconnectivity information on the oligomer. The results demonstrate the potential applicability of 2D MS/MS strategies to the modern omics workflow and structural analysis of various classes of biopolymers.
- 24 January 2024
- Published by Wiley in Angewandte Chemie
- Vol. 136 (9)
Open AccessTwo‐Dimensional Tandem Mass Spectrometry for Biopolymer Structural Analysis
Biopolymer analysis, including proteomics and glycomics, relies heavily on the use of mass spectrometry for structural elucidation, including sequence determination. Novel methods to improve sample workup, instrument performance, and data analysis continue to be developed to address shortcomings associated with sample preparation, analysis time, data quality, and data interpretation. Here, we present a new method that couples in‐source collision‐induced dissociation (IS‐CID) with two‐dimensional tandem mass spectrometry (2D MS/MS) as a way to simplify proteomics and glycomics workflows while also providing additional insight into analyte structures over traditional MS/MS experiments. Specifically, IS‐CID is employed as a gas‐phase digestion method, i.e., to break down intact full‐length polysaccharide or peptide ions prior to mass analysis. The resulting mixtures of oligomeric ions are analyzed by 2D‐MS/MS, a technique that allows association of product ions with their precursor ions without isolation of the latter. A novel data analysis strategy is introduced to leverage the second dimension of 2D MS/MS spectra, in which stairstep patterns, representing outputs of a molecule's MSn scans, are extracted for structural interconnectivity information on the oligomer. The results demonstrate the potential applicability of 2D MS/MS strategies to the modern omics workflow and structural analysis of various classes of biopolymers.
- Open Access
- 24 January 2024
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 63 (9) , e202315904
Two‐Dimensional Tandem Mass Spectrometry for Biopolymer Structural Analysis
Biopolymer analysis, including proteomics and glycomics, relies heavily on the use of mass spectrometry for structural elucidation, including sequence determination. Novel methods to improve sample workup, instrument performance, and data analysis continue to be developed to address shortcomings associated with sample preparation, analysis time, data quality, and data interpretation. Here, we present a new method that couples in‐source collision‐induced dissociation (IS‐CID) with two‐dimensional tandem mass spectrometry (2D MS/MS) as a way to simplify proteomics and glycomics workflows while also providing additional insight into analyte structures over traditional MS/MS experiments. Specifically, IS‐CID is employed as a gas‐phase digestion method, i.e., to break down intact full‐length polysaccharide or peptide ions prior to mass analysis. The resulting mixtures of oligomeric ions are analyzed by 2D‐MS/MS, a technique that allows association of product ions with their precursor ions without isolation of the latter. A novel data analysis strategy is introduced to leverage the second dimension of 2D MS/MS spectra, in which stairstep patterns, representing outputs of a molecule's MSn scans, are extracted for structural interconnectivity information on the oligomer. The results demonstrate the potential applicability of 2D MS/MS strategies to the modern omics workflow and structural analysis of various classes of biopolymers.
- 24 January 2024
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 63 (9) , e202315904
Open AccessTwo‐Dimensional Tandem Mass Spectrometry for Biopolymer Structural Analysis
Biopolymer analysis, including proteomics and glycomics, relies heavily on the use of mass spectrometry for structural elucidation, including sequence determination. Novel methods to improve sample workup, instrument performance, and data analysis continue to be developed to address shortcomings associated with sample preparation, analysis time, data quality, and data interpretation. Here, we present a new method that couples in‐source collision‐induced dissociation (IS‐CID) with two‐dimensional tandem mass spectrometry (2D MS/MS) as a way to simplify proteomics and glycomics workflows while also providing additional insight into analyte structures over traditional MS/MS experiments. Specifically, IS‐CID is employed as a gas‐phase digestion method, i.e., to break down intact full‐length polysaccharide or peptide ions prior to mass analysis. The resulting mixtures of oligomeric ions are analyzed by 2D‐MS/MS, a technique that allows association of product ions with their precursor ions without isolation of the latter. A novel data analysis strategy is introduced to leverage the second dimension of 2D MS/MS spectra, in which stairstep patterns, representing outputs of a molecule's MSn scans, are extracted for structural interconnectivity information on the oligomer. The results demonstrate the potential applicability of 2D MS/MS strategies to the modern omics workflow and structural analysis of various classes of biopolymers.
- 24 October 2019
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 30 (12) , 2670-2677
Identification and Quantitation of Linear Alkanes in Lubricant Base Oils by Using GC×GC/EI TOF Mass Spectrometry
Linear alkanes are a class of compounds known to negatively affect the physical performance of lubricant base oils. The ability to rapidly identify and quantify linear alkanes in lubricant base oils would enable oil companies to more effectively evaluate their refinery methods for converting crude oil to lubricant base oils. While mass spectrometry is a powerful method for elucidation of the structures of compounds in complex mixtures, it is not innately quantitative. An approach is presented here for the identification and quantitation of linear alkanes in base oil samples by utilizing GC×GC/EI TOF MS. Identification of the linear alkanes in base oils was achieved based on their retention times in both GC columns as well as their EI mass spectra. Linear alkane model compound mixtures were used to generate calibration plots for quantitation of the linear alkanes in the base oils. The accuracy of this method was greater than 83.8%, within-day precision lower than 6.2%, between-day precision lower than 16.2%, and total precision lower than 17.2%. All noted figures of merit surpass the acceptable limits for a new validated quantitative method, where accuracy must be better than 80% and precision lower than 20% at the lower limit of quantitation. The n-alkane content in both base oil samples was further validated using a GC×GC/FID method (the gold standard for quantitation), which provided nearly identical results to those obtained using the GC×GC/EI TOF MS method. Therefore, GC×GC/EI TOF MS can be used to both identify and quantitate linear alkanes.
- 24 October 2019
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 30 (12) , 2670-2677
Identification and Quantitation of Linear Alkanes in Lubricant Base Oils by Using GC×GC/EI TOF Mass Spectrometry
Linear alkanes are a class of compounds known to negatively affect the physical performance of lubricant base oils. The ability to rapidly identify and quantify linear alkanes in lubricant base oils would enable oil companies to more effectively evaluate their refinery methods for converting crude oil to lubricant base oils. While mass spectrometry is a powerful method for elucidation of the structures of compounds in complex mixtures, it is not innately quantitative. An approach is presented here for the identification and quantitation of linear alkanes in base oil samples by utilizing GC×GC/EI TOF MS. Identification of the linear alkanes in base oils was achieved based on their retention times in both GC columns as well as their EI mass spectra. Linear alkane model compound mixtures were used to generate calibration plots for quantitation of the linear alkanes in the base oils. The accuracy of this method was greater than 83.8%, within-day precision lower than 6.2%, between-day precision lower than 16.2%, and total precision lower than 17.2%. All noted figures of merit surpass the acceptable limits for a new validated quantitative method, where accuracy must be better than 80% and precision lower than 20% at the lower limit of quantitation. The n-alkane content in both base oil samples was further validated using a GC×GC/FID method (the gold standard for quantitation), which provided nearly identical results to those obtained using the GC×GC/EI TOF MS method. Therefore, GC×GC/EI TOF MS can be used to both identify and quantitate linear alkanes.
- 12 October 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (21) , 10592-10598
Comparison of Atmospheric Pressure Chemical Ionization and Field Ionization Mass Spectrometry for the Analysis of Large Saturated Hydrocarbons
Direct infusion atmospheric pressure chemical ionization mass spectrometry (APCI-MS) was compared to field ionization mass spectrometry (FI-MS) for the determination of hydrocarbon class distributions in lubricant base oils. When positive ion mode APCI with oxygen as the ion source gas was employed to ionize saturated hydrocarbon model compounds (M) in hexane, only stable [M – H]+ ions were produced. Ion–molecule reaction studies performed in a linear quadrupole ion trap suggested that fragment ions of ionized hexane can ionize saturated hydrocarbons via hydride abstraction with minimal fragmentation. Hence, APCI-MS shows potential as an alternative of FI-MS in lubricant base oil analysis. Indeed, the APCI-MS method gave similar average molecular weights and hydrocarbon class distributions as FI-MS for three lubricant base oils. However, the reproducibility of APCI-MS method was found to be substantially better than for FI-MS. The paraffinic content determined using the APCI-MS and FI-MS methods for the base oils was similar. The average number of carbons in paraffinic chains followed the same increasing trend from low viscosity to high viscosity base oils for the two methods.
- 12 October 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (21) , 10592-10598
Comparison of Atmospheric Pressure Chemical Ionization and Field Ionization Mass Spectrometry for the Analysis of Large Saturated Hydrocarbons
Direct infusion atmospheric pressure chemical ionization mass spectrometry (APCI-MS) was compared to field ionization mass spectrometry (FI-MS) for the determination of hydrocarbon class distributions in lubricant base oils. When positive ion mode APCI with oxygen as the ion source gas was employed to ionize saturated hydrocarbon model compounds (M) in hexane, only stable [M – H]+ ions were produced. Ion–molecule reaction studies performed in a linear quadrupole ion trap suggested that fragment ions of ionized hexane can ionize saturated hydrocarbons via hydride abstraction with minimal fragmentation. Hence, APCI-MS shows potential as an alternative of FI-MS in lubricant base oil analysis. Indeed, the APCI-MS method gave similar average molecular weights and hydrocarbon class distributions as FI-MS for three lubricant base oils. However, the reproducibility of APCI-MS method was found to be substantially better than for FI-MS. The paraffinic content determined using the APCI-MS and FI-MS methods for the base oils was similar. The average number of carbons in paraffinic chains followed the same increasing trend from low viscosity to high viscosity base oils for the two methods.
- 13 July 2016
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 70 (7) , 1109-1117
Forensic Hair Differentiation Using Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) Spectroscopy
Hair and fibers are common forms of trace evidence found at crime scenes. The current methodology of microscopic examination of potential hair evidence is absent of statistical measures of performance, and examiner results for identification can be subjective. Here, attenuated total reflection (ATR) Fourier transform-infrared (FT-IR) spectroscopy was used to analyze synthetic fibers and natural hairs of human, cat, and dog origin. Chemometric analysis was used to differentiate hair spectra from the three different species, and to predict unknown hairs to their proper species class, with a high degree of certainty. A species-specific partial least squares discriminant analysis (PLSDA) model was constructed to discriminate human hair from cat and dog hairs. This model was successful in distinguishing between the three classes and, more importantly, all human samples were correctly predicted as human. An external validation resulted in zero false positive and false negative assignments for the human class. From a forensic perspective, this technique would be complementary to microscopic hair examination, and in no way replace it. As such, this methodology is able to provide a statistical measure of confidence to the identification of a sample of human, cat, and dog hair, which was called for in the 2009 National Academy of Sciences report. More importantly, this approach is non-destructive, rapid, can provide reliable results, and requires no sample preparation, making it of ample importance to the field of forensic science.
- 13 July 2016
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 70 (7) , 1109-1117
Forensic Hair Differentiation Using Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) Spectroscopy
Hair and fibers are common forms of trace evidence found at crime scenes. The current methodology of microscopic examination of potential hair evidence is absent of statistical measures of performance, and examiner results for identification can be subjective. Here, attenuated total reflection (ATR) Fourier transform-infrared (FT-IR) spectroscopy was used to analyze synthetic fibers and natural hairs of human, cat, and dog origin. Chemometric analysis was used to differentiate hair spectra from the three different species, and to predict unknown hairs to their proper species class, with a high degree of certainty. A species-specific partial least squares discriminant analysis (PLSDA) model was constructed to discriminate human hair from cat and dog hairs. This model was successful in distinguishing between the three classes and, more importantly, all human samples were correctly predicted as human. An external validation resulted in zero false positive and false negative assignments for the human class. From a forensic perspective, this technique would be complementary to microscopic hair examination, and in no way replace it. As such, this methodology is able to provide a statistical measure of confidence to the identification of a sample of human, cat, and dog hair, which was called for in the 2009 National Academy of Sciences report. More importantly, this approach is non-destructive, rapid, can provide reliable results, and requires no sample preparation, making it of ample importance to the field of forensic science.