RIRintaro Ito

Rintaro Ito

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rintaro Ito has a total of 123 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The evolving role of cardiac CT: Emerging technologies and clinical impact

    by Seitaro Oda, Mami Iima, Masahiro Yanagawa, Tsukasa Saida, Satoru Ide, Koji Takumi, Rintaro Ito, Ryo Kurokawa, Maya Honda, Kentaro Nishioka, et al.


  • Percutaneous thermal ablation for renal cell carcinoma: a comprehensive review of current evidence and future directions

    by Shunsuke Sugawara, Ryo Kurokawa, Satoru Ide, Masahiro Yanagawa, Mami Iima, Tsukasa Saida, Daiju Ueda, Kentaro Nishioka, Seitaro Oda, Maya Honda, et al.

  • Open Access

    DTI-ALPS after the Tracer Challenge: Reconsidering the Biomarker and the Benchmark

    by Toshiaki Taoka, Rintaro Ito, Rei Nakamichi, Toshiki Nakane, Shinji Naganawa

    Diffusion tensor image analysis along the perivascular space (DTI-ALPS) was introduced in 2017 as a possible noninvasive marker of glymphatic function. Its interpretation was reconsidered in a 2024 review and further developed in a 2026 review, which described the ALPS index as a structure-dependent, spatially fixed-point diffusion biomarker. Separately, Mossige et al. reported limited agreement between the ALPS index and intrathecal tracer MRI. Recent studies continue to use DTI-ALPS, but with more cautious interpretation. Intrathecal tracer MRI provides important evidence of cerebrospinal fluid–related transport in humans, although it cannot represent all pathways of endogenous brain clearance. As a noncontrast method, DTI-ALPS may be useful in large-scale and longitudinal studies of local white matter properties. Both DTI-ALPS and intrathecal tracer MRI require further validation for their intended uses.

  • Open Access

    Evaluation of Approved AI-based Brain Aneurysm Detection Software in Clinical Practice: Comparison with Radiologist Assessment and Image Re-review

    by Rintaro Ito, Ryota Asai, Rei Nakamichi, Toshiki Nakane, Toshiaki Taoka, Shinji Naganawa

    Purpose: This study evaluated the performance of artificial intelligence (AI)-based brain aneurysm detection software in clinical settings, aiming to assess its utility as a supportive tool for radiologists. Metrics included sensitivity, positive predictive value (PPV), F1 score, and false positives (FPs) per case.Methods: A retrospective analysis of 442 cases (March 2023–August 2024) compared AI detections against a reference standard derived from the radiologists’ assessments and image re-review. Findings were categorized into true positives (TPs), FPs, and false negatives (FNs). Subgroup analyses covered aneurysm size, magnetic field strength of the MRI, patient age, and aneurysm location.Results: The study included 442 cases (226 males, 216 females; median age 72). Out of 94 total aneurysms, the AI detected 73 TP and missed 21 FN. It also identified 520 FP. Overall, sensitivity was 77.7%, PPV was 12.3%, and the F1 score was 0.212. The FPs averaged 1.18 per case. Sensitivity varied by aneurysm size: 85.1% for ≤ 3 mm, 69.2% for 3–5 mm, and 50.0% for > 5 mm. Significant variability in FPs per case was observed across different magnetic field strengths. Performance also varied by patient age and aneurysm location.Conclusion: The AI software demonstrated moderate sensitivity, especially for smaller aneurysms. Variations in performance across different magnetic field strengths and aneurysm size suggest a need for more robust AI algorithms. Detailed analysis of aneurysm locations provides insights into areas where AI performance could be enhanced. Integrating the AI software as a supportive tool, combined with radiologist expertise, is hypothesized to enhance detection accuracy, though further studies are needed to quantify this combined effect.


  • Breast cancer imaging without gadolinium-based contrast agent: A review of current applications and future trends

    by Maya Honda, Mami Iima, Masako Kataoka, Daiju Ueda, Tsukasa Saida, Kentaro Nishioka, Ryo Kurokawa, Satoru Ide, Masahiro Yanagawa, Tadashi Watabe, et al.


  • Open Access

    Physiological Biodistribution of 18F-fluciclovine in The Head

    by Yumi Abe, Ryogo Minamimoto, Naotoshi Fujita, Marina Higashi, Rintaro Ito, Katsuhiko Kato, Shoichi Deguchi, Fumiharu Ohka, Ryuta Saito, Shinji Naganawa

    Objective: Anti-1-amino-3-[18F]fluorocyclobutane-1-carboxylic acid (18F-fluciclovine; anti-3-[18F]FACBC) is an amino acid positron emission tomography (PET) tracer used for the evaluation of brain tumors in cases of suspected or diagnosed glioma. However, reports on the physiological biodistribution of 18F-fluciclovine in the head, are limited. This study retrospectively analyzed the physiological biodistribution of 18F-fluciclovine PET in the head. Methods: We analyzed 18F-fluciclovine PET/CT images of 20 patients who were suspected of malignant glioma. The maximum and mean standard uptake values (SUVmax and SUVmean) were measured in the 24 areas of the head tissues. Time-activity curves were generated, with the volume of index placed in the same manner as for the SUV measurements to obtain dynamic uptake over time. Differences in SUV between regions were assessed using one-way analysis of variance. Among 20 patients who received 18F-fluciclovine PET/CT, physiological biodistribution analyses were performed in 8 patients who also underwent 11C- methionine PET/CT. Comparisons of SUV between 18F-fluciclovine and 11C-methionine PET were performed using paired t-tests. Statistical significance was set at P < 0.05 for all analyses. Results: 18F-fluciclovine uptake in the cerebral cortex was uniformly low (mean SUVmean 0.3 ± 0.1), with slightly higher values in the basal ganglia, thalamus, midbrain, pons, medulla oblongata, cerebellum, and cerebellar vermis (0.4 ± 0.1). Among extracerebral regions, the highest uptake was in the parotid gland (3.4 ± 0.8), followed by the pharynx (2.5 ± 0.5), pituitary gland, nasal cavity (2.3 ± 0.4), muscle (2.2 ± 0.6), bone marrow (2.0 ± 0.5), and skin (1.9 ± 0.6). In 15 patients, brain uptake remained low and stable, while the pituitary gland and parotid glands peaked immediately after injection and declined rapidly. In 8 patients with 11C-methionine PET, methionine showed significantly higher uptake in all brain regions, whereas 18F-fluciclovine was higher in the venous sinus, cavernous sinus, muscle, and nasal cavity. Conclusion: Understanding these physiological biodistribution patterns of 18F-fluciclovine PET is essential for distinguishing between pathological uptake patterns and for providing useful baseline data. Furthermore, 18F-fluciclovine uptake in the brain was uniformly low in the cerebral cortex, with minimal nonspecific uptake, suggesting that it may contribute to defining tumor margins.

  • Japanese Radiology 2025 Updates

    by Mami Iima, Tsukasa Saida, Yoshitake Yamada, Ryo Kurokawa, Daiju Ueda, Maya Honda, Kentaro Nishioka, Rintaro Ito, Keitaro Sofue, Shinji Naganawa

    This review provides a comprehensive overview of recent transformative advancements in diagnostic imaging that position Japan at the forefront of radiological innovation. We highlight pivotal innovations that enhance diagnostic capabilities and redefine clinical workflows. The article begins with upright multidetector computed tomography (MDCT), a groundbreaking technology offering novel insights into posture-dependent anatomical and physiological changes. We then explore significant progress in breast and gynecologic imaging, including advancements in artificial intelligence computer-aided (AI-CAD) synthesized mammograms, automated breast ultrasound (ABUS), and abbreviated MRI protocols. These innovations address unique regional challenges in early cancer detection. Significant innovations in abdominal radiology, spanning advanced CT (including photon-counting detector CT), accelerated MRI, and AI applications, are also discussed. The review further delves into glymphatic system research, where advanced MRI techniques, particularly DTI-ALPS, are unraveling new insights into brain waste clearance and neurological disorders. Finally, we examine the future of Japanese radiology through the lens of AI, with a focus on Large Language Models (LLMs). We discuss their growing role in diagnostic support, report generation, and information extraction, as well as important societal and ethical considerations. These collective advancements underscore Japan’s dynamic contributions to radiological innovation, poised to significantly impact global healthcare practices by improving disease detection, optimizing workflows, and extending healthy life expectancy in an aging society.


  • Open Access

    Scoping Review of Regulatory Transparency in AI-based Radiology Software: Analysis of PMDA-approved SaMD Products

    by Tomohiro Kikuchi, Shannon L Walston, Hirotaka Takita, Yasuhito Mitsuyama, Rintaro Ito, Masahiro Hashimoto, Takeshi Nakaura, Hiroaki Hyakutake, Sho Kawabe, Harushi Mori, et al.

    Background The integration of artificial intelligence (AI) in radiology has accelerated globally, with Japan’s Pharmaceuticals and Medical Devices Agency (PMDA) approving numerous AI-based Software as a Medical Device (SaMD) products. However, the transparency and completeness of clinical evidence available to healthcare providers remain unclear. Purpose To systematically evaluate the availability and transparency of clinical evidence in package inserts of PMDA-approved AI-based radiology SaMD products, identifying gaps that may impact clinical implementation. Materials and Methods We conducted a systematic review of all PMDA-approved SaMD products as of December 31, 2024. Products were included if they utilized AI technology and were classified for radiology applications. Data extraction focused on product characteristics, study designs, demographic information, and performance metrics. Results Of 151 approved SaMD products, 40 utilized AI technology, with 20 specifically designed for radiology applications. Critical gaps were identified in demographic reporting, with no products providing complete case demographic data. Performance metrics varied widely, with sensitivity ranging from 67.7% to 100% in standalone studies. Physician-assisted studies consistently demonstrated performance improvements but lacked stratified results by characteristics in all cases. Conclusion Current package insert requirements provide insufficient transparency for evidence-based clinical implementation of AI-based radiology software. Enhanced regulatory frameworks and industry-led initiatives for comprehensive validation are essential for safe and effective AI deployment in Japanese healthcare.

  • Open Access

    Photon-counting detector computed tomography in thoracic oncology: revolutionizing tumor imaging through precision and detail

    by Masahiro Yanagawa, Midori Ueno, Rintaro Ito, Daiju Ueda, Tsukasa Saida, Ryo Kurokawa, Koji Takumi, Kentaro Nishioka, Shunsuke Sugawara, Satoru Ide, et al.

    Photon-counting detector computed tomography in thoracic oncology: revolutionizing tumor imaging through precision and detail - Diagnostic and Interventional Radiology