Marta Babicz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Marta Babicz has a total of 368 co-authors. Here are the top co-authors by number of shared publications:
- Gianluca L. Raselli
Istituto Nazionale di Fisica Nucleare Sezione di Pavia
10 shared publications - Andrea Zani
Istituto Nazionale di Fisica Nucleare Sezione di Milano, 20133 Milano
6 shared publications Alessandro Menegolli
INFN, Sez Pavia, Via Bassi 6, Pavia, Italy
5 shared publicationsM. Nessi
CERN, Switzerland
5 shared publicationsMassimo Rossella
INFN, Sez Pavia, Via Bassi 6, Pavia, Italy
5 shared publicationsAndrea Falcone
Univ Texas Arlington, Arlington, TX 76019 USA
4 shared publications
Latest Publications
- Open Access
- 17 June 2026
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 7 (4) , 045023
Transformer-based pulse shape discrimination in HPGe detectors with masked autoencoder pre-training
Pulse-shape discrimination (PSD) in high-purity germanium (HPGe) detectors is central to rare-event searches such as neutrinoless double-beta decay (0νββ), yet conventional approaches compress each waveform into a small set of summary parameters, potentially discarding information in the full time series that is relevant for classification. We benchmark transformer-based models that operate directly on digitised waveforms using the Majorana Demonstrator AI/ML data release. Models are trained to reproduce the collaborationprovided accept/reject labels for four standard PSD cuts and to regress calibrated energy. We compare supervised training from scratch, masked autoencoder (MAE) self-supervised pretraining followed by fine-tuning, and a feature-based gradient-boosted decision tree (GBDT) baseline. Transformers outperform GBDT across all PSD targets, with the largest gains on the most challenging labels and on the combined PSD-pass definition. MAE pre-training improves sample efficiency, reducing labelled-data requirements by factors of 2-4 in low-label regimes. For energy regression, both transformer variants show a small common underestimation on the test split, while fine-tuning modestly narrows the residual distribution. These results motivate follow-up studies of robustness across detectors and operating conditions and of performance near Qββ .
- 17 June 2026
- Published by IOP Publishing in Machine Learning: Science and Technology
- Vol. 7 (4) , 045023
Open AccessTransformer-based pulse shape discrimination in HPGe detectors with masked autoencoder pre-training
Pulse-shape discrimination (PSD) in high-purity germanium (HPGe) detectors is central to rare-event searches such as neutrinoless double-beta decay (0νββ), yet conventional approaches compress each waveform into a small set of summary parameters, potentially discarding information in the full time series that is relevant for classification. We benchmark transformer-based models that operate directly on digitised waveforms using the Majorana Demonstrator AI/ML data release. Models are trained to reproduce the collaborationprovided accept/reject labels for four standard PSD cuts and to regress calibrated energy. We compare supervised training from scratch, masked autoencoder (MAE) self-supervised pretraining followed by fine-tuning, and a feature-based gradient-boosted decision tree (GBDT) baseline. Transformers outperform GBDT across all PSD targets, with the largest gains on the most challenging labels and on the combined PSD-pass definition. MAE pre-training improves sample efficiency, reducing labelled-data requirements by factors of 2-4 in low-label regimes. For energy regression, both transformer variants show a small common underestimation on the test split, while fine-tuning modestly narrows the residual distribution. These results motivate follow-up studies of robustness across detectors and operating conditions and of performance near Qββ .
- Top Cited PapersOpen Access
- 16 January 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (2) , 022701
First Results on the Search for Lepton Number Violating Neutrinoless Double- β Decay with the LEGEND-200 Experiment
The LEGEND Collaboration is searching for neutrinoless double-beta ( 0 ν β β ) decay by operating high-purity germanium detectors enriched in Ge 76 in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0 ν β β decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5 − 0.2 + 0.3 cts / ( keV ton yr ) in the 0 ν β β decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 × 10 26 yr on the half-life of 0 ν β β decay, reveals no evidence for a signal and sets a new observed lower limit at T 1 / 2 0 ν > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range m β β < 75 – 200 meV , depending on the adopted nuclear matrix element.
- 16 January 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (2) , 022701
Top Cited PapersOpen AccessFirst Results on the Search for Lepton Number Violating Neutrinoless Double- β Decay with the LEGEND-200 Experiment
The LEGEND Collaboration is searching for neutrinoless double-beta ( 0 ν β β ) decay by operating high-purity germanium detectors enriched in Ge 76 in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0 ν β β decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5 − 0.2 + 0.3 cts / ( keV ton yr ) in the 0 ν β β decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 × 10 26 yr on the half-life of 0 ν β β decay, reveals no evidence for a signal and sets a new observed lower limit at T 1 / 2 0 ν > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range m β β < 75 – 200 meV , depending on the adopted nuclear matrix element.
- Open Access
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , C05033
Demonstration of the light collection stability of a PEN-based wavelength shifting reflector in a tonne scale liquid argon detector
Liquid argon detectors rely on wavelength shifters for efficient detection of scintillation light. The current standard is tetraphenyl butadiene (TPB), but it is challenging to instrument on a large scale. Poly(ethylene 2,6-naphthalate) (PEN), a polyester easily manufactured as thin sheets, could simplify the coverage of large surfaces with wavelength shifters. Previous measurements have shown that commercial grades of PEN have approximately 50% light conversion efficiency relative to TPB. Encouraged by these results, we conducted a large-scale measurement using 4 m2 combined PEN and specular reflector foils in a two-tonne liquid argon dewar to assess its stability over approximately two weeks. This test is crucial for validating PEN as a viable substitute for TPB. The setup used for the measurement of the stability of PEN as a wavelength shifter is described, together with the first results, showing no evidence of performance deterioration over a period of 12 days.
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , C05033
Open AccessDemonstration of the light collection stability of a PEN-based wavelength shifting reflector in a tonne scale liquid argon detector
Liquid argon detectors rely on wavelength shifters for efficient detection of scintillation light. The current standard is tetraphenyl butadiene (TPB), but it is challenging to instrument on a large scale. Poly(ethylene 2,6-naphthalate) (PEN), a polyester easily manufactured as thin sheets, could simplify the coverage of large surfaces with wavelength shifters. Previous measurements have shown that commercial grades of PEN have approximately 50% light conversion efficiency relative to TPB. Encouraged by these results, we conducted a large-scale measurement using 4 m2 combined PEN and specular reflector foils in a two-tonne liquid argon dewar to assess its stability over approximately two weeks. This test is crucial for validating PEN as a viable substitute for TPB. The setup used for the measurement of the stability of PEN as a wavelength shifter is described, together with the first results, showing no evidence of performance deterioration over a period of 12 days.
- Open Access
- 1 April 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (04) , P04013
Commissioning of the 2.6 m tall two-phase xenon time projection chamber of Xenoscope
Xenoscope is a demonstrator for a next-generation xenon-based observatory for astroparticle physics, as proposed by the XLZD (XENON-LUX-ZEPLIN-DARWIN) collaboration. It houses a 2.6 m tall, two-phase xenon time projection chamber (TPC), in a cryostat filled with ∼360 kg of liquid xenon. The main goals of the facility are to demonstrate electron drift in liquid xenon over this distance, to measure the electron cloud transversal and longitudinal diffusion, as well as the optical properties of the medium. In this work, we describe in detail the construction and commissioning of the TPC and report on the observation of light and charge signals with cosmic muons.
- 1 April 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (04) , P04013
Open AccessCommissioning of the 2.6 m tall two-phase xenon time projection chamber of Xenoscope
Xenoscope is a demonstrator for a next-generation xenon-based observatory for astroparticle physics, as proposed by the XLZD (XENON-LUX-ZEPLIN-DARWIN) collaboration. It houses a 2.6 m tall, two-phase xenon time projection chamber (TPC), in a cryostat filled with ∼360 kg of liquid xenon. The main goals of the facility are to demonstrate electron drift in liquid xenon over this distance, to measure the electron cloud transversal and longitudinal diffusion, as well as the optical properties of the medium. In this work, we describe in detail the construction and commissioning of the TPC and report on the observation of light and charge signals with cosmic muons.
- Open Access
- 21 June 2022
- Published by American Physical Society (APS) in Physical Review D
- Vol. 105 (11) , 112009
Adversarial methods to reduce simulation bias in neutrino interaction event filtering at liquid argon time projection chambers
For current and future neutrino oscillation experiments using large liquid argon time projection chambers (LAr-TPCs), a key challenge is identifying neutrino interactions from the pervading cosmic-ray background. Rejection of such background is often possible using traditional cut-based selections, but this typically requires the prior use of computationally expensive reconstruction algorithms. This work demonstrates an alternative approach of using a 3D submanifold sparse convolutional network trained on low-level information from the scintillation light signal of interactions inside LAr-TPCs. This technique is applied to example simulations from ICARUS, the far detector of the short baseline neutrino program at Fermilab. The results of the network, show that cosmic background is reduced by up to 76.3% whilst neutrino interaction selection efficiency remains over 98.9%. We further present a way to mitigate potential biases from imperfect input simulations by applying domain adversarial neural networks (DANNs), for which modified simulated samples are introduced to imitate real data and a small portion of them are used for adversarial training. A series of mock-data studies are performed and demonstrate the effectiveness of using DANNs to mitigate biases, showing neutrino interaction selection efficiency performances significantly better than that achieved without the adversarial training.
- 21 June 2022
- Published by American Physical Society (APS) in Physical Review D
- Vol. 105 (11) , 112009
Open AccessAdversarial methods to reduce simulation bias in neutrino interaction event filtering at liquid argon time projection chambers
For current and future neutrino oscillation experiments using large liquid argon time projection chambers (LAr-TPCs), a key challenge is identifying neutrino interactions from the pervading cosmic-ray background. Rejection of such background is often possible using traditional cut-based selections, but this typically requires the prior use of computationally expensive reconstruction algorithms. This work demonstrates an alternative approach of using a 3D submanifold sparse convolutional network trained on low-level information from the scintillation light signal of interactions inside LAr-TPCs. This technique is applied to example simulations from ICARUS, the far detector of the short baseline neutrino program at Fermilab. The results of the network, show that cosmic background is reduced by up to 76.3% whilst neutrino interaction selection efficiency remains over 98.9%. We further present a way to mitigate potential biases from imperfect input simulations by applying domain adversarial neural networks (DANNs), for which modified simulated samples are introduced to imitate real data and a small portion of them are used for adversarial training. A series of mock-data studies are performed and demonstrate the effectiveness of using DANNs to mitigate biases, showing neutrino interaction selection efficiency performances significantly better than that achieved without the adversarial training.