Saba Kalantary
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Saba Kalantary has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Ali Jahani
Faculty of Assessment and Environment Risks Department, Research Center of Environment and Sustainable Development, Tehran, Iran
2 shared publications Ensieh Masoorian
Department of Pathobiology, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
2 shared publicationsFarideh Golbabei
Department of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
2 shared publicationsKamal Azam
Department of Epidemiology and Biostatistics, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
2 shared publications- Leila Omidi
Department of Occupational Health Engineering, School of Public Health Tehran University of Medical Sciences Tehran Iran
2 shared publications - Mir Saeed Yekaninejad
Department of Epidemiology and Biostatistics, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
2 shared publications
Latest Publications
- Open Access
- 1 May 2025
- Published by SAGE Publications in Journal of Industrial Textiles
- Vol. 55
Comparison of filtration performance and antibacterial properties of nanofibers containing natural (thyme) and synthetic (ZIF-8) compounds in face mask media: Evaluating the potential of natural compounds as substitutes for synthetic agents: Natural vs. synthetic antibacterial nanofibers in face masks
This study introduces a comparative approach to integrating natural and synthetic antibacterial agents into electrospun nanofiber media for face masks, aiming to reduce health and environmental concerns associated with synthetic compounds. Polyacrylonitrile (PAN) nanofibers incorporating thyme extract (5, 20, 40, 60 wt%) and ZIF-8 (5, 7, 10, 15 wt%) were fabricated and evaluated. Structural analyses confirmed uniform bead-free nanofibers with average diameters ranging from 207.5 to 234.2 nm and membrane thicknesses around 150 µm. FTIR and XRD data verified successful incorporation and chemical bonding of additives within the PAN matrix. Performance testing demonstrated that thyme-based nanofibers (40 wt%) achieved a particle filtration efficiency (PFE) of 96.83% (0.3 µm), 100% bacterial filtration efficiency (BFE), and a pressure drop of 20.33 Pa. ZIF-8 nanofibers (7 wt%) achieved 96.58% PFE and 96.06% BFE with a pressure drop of 25 Pa. Time-kill assays showed superior antibacterial activity of thyme compared to ZIF-8 over a 4-h period. Compared to melt-blown media, nanofiber samples provided significantly higher filtration performance with acceptable breathability. The findings highlight that thyme-loaded nanofibers offer a biodegradable, non-toxic, and efficient alternative to synthetic agents such as ZIF-8. This work provides new insights into structure–property–performance relationships in functional nanofibers and suggests natural compounds as promising candidates for safer and more sustainable face mask technologies though further research on scalability, long-term stability, mechanical durability, biodegradability, and breathability is warranted.
- 1 May 2025
- Published by SAGE Publications in Journal of Industrial Textiles
- Vol. 55
Open AccessComparison of filtration performance and antibacterial properties of nanofibers containing natural (thyme) and synthetic (ZIF-8) compounds in face mask media: Evaluating the potential of natural compounds as substitutes for synthetic agents: Natural vs. synthetic antibacterial nanofibers in face masks
This study introduces a comparative approach to integrating natural and synthetic antibacterial agents into electrospun nanofiber media for face masks, aiming to reduce health and environmental concerns associated with synthetic compounds. Polyacrylonitrile (PAN) nanofibers incorporating thyme extract (5, 20, 40, 60 wt%) and ZIF-8 (5, 7, 10, 15 wt%) were fabricated and evaluated. Structural analyses confirmed uniform bead-free nanofibers with average diameters ranging from 207.5 to 234.2 nm and membrane thicknesses around 150 µm. FTIR and XRD data verified successful incorporation and chemical bonding of additives within the PAN matrix. Performance testing demonstrated that thyme-based nanofibers (40 wt%) achieved a particle filtration efficiency (PFE) of 96.83% (0.3 µm), 100% bacterial filtration efficiency (BFE), and a pressure drop of 20.33 Pa. ZIF-8 nanofibers (7 wt%) achieved 96.58% PFE and 96.06% BFE with a pressure drop of 25 Pa. Time-kill assays showed superior antibacterial activity of thyme compared to ZIF-8 over a 4-h period. Compared to melt-blown media, nanofiber samples provided significantly higher filtration performance with acceptable breathability. The findings highlight that thyme-loaded nanofibers offer a biodegradable, non-toxic, and efficient alternative to synthetic agents such as ZIF-8. This work provides new insights into structure–property–performance relationships in functional nanofibers and suggests natural compounds as promising candidates for safer and more sustainable face mask technologies though further research on scalability, long-term stability, mechanical durability, biodegradability, and breathability is warranted.
- 23 December 2024
- Published by Wolters Kluwer Health in Journal of Occupational and Environmental Medicine
- Vol. 67 (4) , e197-e202
Assessing Long-Term Impacts of Occupational Welding Fume Exposure on Respiratory Health
Background: Welding in automobile manufacturing exposes workers to harmful fumes, impacting pulmonary function. This study examined changes in pulmonary function among welders. Methods: A retrospective cohort study was conducted on 1200 welders and 1200 administrative staff in the automotive industry from 2018 to 2022. Pulmonary function tests were performed according to ATS guidelines, and metal fume sampling for copper, iron, and lead was conducted in welders’ respiratory zones. Results: The mean concentrations of Cu, Pb, and Fe were 0.124, 0.117, and 1.42 mg/m3, respectively. Pb exceeded TLV-TWA. Welders showed significantly lower pulmonary function compared with the control group (P < 0.05). Conclusions: Prolonged exposure to welding fumes significantly reduces pulmonary function, necessitating preventive measures.
- 23 December 2024
- Published by Wolters Kluwer Health in Journal of Occupational and Environmental Medicine
- Vol. 67 (4) , e197-e202
Assessing Long-Term Impacts of Occupational Welding Fume Exposure on Respiratory Health
Background: Welding in automobile manufacturing exposes workers to harmful fumes, impacting pulmonary function. This study examined changes in pulmonary function among welders. Methods: A retrospective cohort study was conducted on 1200 welders and 1200 administrative staff in the automotive industry from 2018 to 2022. Pulmonary function tests were performed according to ATS guidelines, and metal fume sampling for copper, iron, and lead was conducted in welders’ respiratory zones. Results: The mean concentrations of Cu, Pb, and Fe were 0.124, 0.117, and 1.42 mg/m3, respectively. Pb exceeded TLV-TWA. Welders showed significantly lower pulmonary function compared with the control group (P < 0.05). Conclusions: Prolonged exposure to welding fumes significantly reduces pulmonary function, necessitating preventive measures.
- Open Access
- 25 May 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-12
Occupational exposure, carcinogenic and non-carcinogenic risk assessment of formaldehyde in the pathology labs of hospitals in Iran
Formaldehyde, a known carcinogenic compound, is commonly used in various medical settings. The objective of this study was to assess the carcinogenic and non-carcinogenic risks associated with occupational exposure to formaldehyde. This study was conducted in the pathology labs of four hospitals in Tehran. Cancer and non-cancer risks were evaluated using the quantitative risk assessment method proposed by the United States environmental protection agency (USEPA), along with its provided database known as the integrated risk information system (IRIS). Respiratory symptoms were assessed using the American thoracic society (ATS) questionnaire. The results indicated that 91.23% of exposure levels in occupational groups exceed the NIOSH standard of 0.016 ppm. Regarding carcinogenic risk, 41.03% of all the studied subjects were in the definite carcinogenic risk range (LCR > 10−4), 23.08% were in the possible carcinogenic risk range (10−5 < LCR < 10−4), and 35.90% were in the negligible risk range (LCR < 10−6). The highest index of occupational carcinogenesis was observed in the group of lab technicians with a risk number of 3.7 × 10−4, followed by pathologists with a risk number of 1.7 × 10−4. Furthermore, 23.08% of the studied subjects were within the permitted health risk range (HQ < 1.0), while 76.92% were within the unhealthy risk range (HQ > 1.0). Overall, the findings revealed significantly higher carcinogenic and non-carcinogenic risks among lab technicians and pathologists. Therefore, it is imperative to implement control measures across various hospital departments to mitigate occupational formaldehyde exposure levels proactively. These findings can be valuable for policymakers in the health sector, aiding in the elimination or reduction of airborne formaldehyde exposure in work environments.
- 25 May 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-12
Open AccessOccupational exposure, carcinogenic and non-carcinogenic risk assessment of formaldehyde in the pathology labs of hospitals in Iran
Formaldehyde, a known carcinogenic compound, is commonly used in various medical settings. The objective of this study was to assess the carcinogenic and non-carcinogenic risks associated with occupational exposure to formaldehyde. This study was conducted in the pathology labs of four hospitals in Tehran. Cancer and non-cancer risks were evaluated using the quantitative risk assessment method proposed by the United States environmental protection agency (USEPA), along with its provided database known as the integrated risk information system (IRIS). Respiratory symptoms were assessed using the American thoracic society (ATS) questionnaire. The results indicated that 91.23% of exposure levels in occupational groups exceed the NIOSH standard of 0.016 ppm. Regarding carcinogenic risk, 41.03% of all the studied subjects were in the definite carcinogenic risk range (LCR > 10−4), 23.08% were in the possible carcinogenic risk range (10−5 < LCR < 10−4), and 35.90% were in the negligible risk range (LCR < 10−6). The highest index of occupational carcinogenesis was observed in the group of lab technicians with a risk number of 3.7 × 10−4, followed by pathologists with a risk number of 1.7 × 10−4. Furthermore, 23.08% of the studied subjects were within the permitted health risk range (HQ < 1.0), while 76.92% were within the unhealthy risk range (HQ > 1.0). Overall, the findings revealed significantly higher carcinogenic and non-carcinogenic risks among lab technicians and pathologists. Therefore, it is imperative to implement control measures across various hospital departments to mitigate occupational formaldehyde exposure levels proactively. These findings can be valuable for policymakers in the health sector, aiding in the elimination or reduction of airborne formaldehyde exposure in work environments.
- 9 March 2021
- Published by Wiley in Concurrency and Computation: Practice and Experience
- Vol. 33 (16) , e6258
Development of a decision support system tool to predict the pulmonary function using artificial neural network approach
Summary: The spirometry is considered a preclinical tool for the evaluation of the respiratory system. The formal lung volumes measurement and health status lung system are made using spirometry. Artificial neural network (ANN) has been introduced in solving complex problems in a large number of different settings, including medical diagnosis support system as predictive power. An objective of this research was intended to investigate the development of a new decision support system (DSS) using ANN modeling approaches and algorithms to predict pulmonary function in people. The spirometry data and general characteristics, anthropometric data, and body composition parameters (N = 130) were obtained from subjects. The classification of pulmonary function was performed by the multi‐layer perceptron (MLP) model. Findings show that the MLP model is capable of classifying respiratory abnormalities in different people. The ANN model was totally 93.6%, 92.3%, 84.6%, and 91.5% successful in correctly classified in training, validation, test, and all data, respectively. Also, a DSS tool was created that allows the evaluation and classification of the results of spirometry data. It appears that ANNs are useful in classification pulmonary function.
- 9 March 2021
- Published by Wiley in Concurrency and Computation: Practice and Experience
- Vol. 33 (16) , e6258
Development of a decision support system tool to predict the pulmonary function using artificial neural network approach
Summary: The spirometry is considered a preclinical tool for the evaluation of the respiratory system. The formal lung volumes measurement and health status lung system are made using spirometry. Artificial neural network (ANN) has been introduced in solving complex problems in a large number of different settings, including medical diagnosis support system as predictive power. An objective of this research was intended to investigate the development of a new decision support system (DSS) using ANN modeling approaches and algorithms to predict pulmonary function in people. The spirometry data and general characteristics, anthropometric data, and body composition parameters (N = 130) were obtained from subjects. The classification of pulmonary function was performed by the multi‐layer perceptron (MLP) model. Findings show that the MLP model is capable of classifying respiratory abnormalities in different people. The ANN model was totally 93.6%, 92.3%, 84.6%, and 91.5% successful in correctly classified in training, validation, test, and all data, respectively. Also, a DSS tool was created that allows the evaluation and classification of the results of spirometry data. It appears that ANNs are useful in classification pulmonary function.
- 1 April 2019
- Published by Elsevier in Environmental Research
- Vol. 171, 170-176
Occupational exposure to wood dust and risk of nasopharyngeal cancer: A systematic review and meta-analysis
- 1 April 2019
- Published by Elsevier in Environmental Research
- Vol. 171, 170-176
Occupational exposure to wood dust and risk of nasopharyngeal cancer: A systematic review and meta-analysis
- Open Access
- 1 March 2016
- Published by CMV Verlag in Journal of Occupational Hygiene Engineering
- Vol. 2 (4) , 9-13
Determining Benzene, Toluene, Ethylbenzene and Xylenes (BTEX) Concentrations in the Hydrometallurgical Environment of Sarcheshmeh Copper Complex
- 1 March 2016
- Published by CMV Verlag in Journal of Occupational Hygiene Engineering
- Vol. 2 (4) , 9-13
Open AccessDetermining Benzene, Toluene, Ethylbenzene and Xylenes (BTEX) Concentrations in the Hydrometallurgical Environment of Sarcheshmeh Copper Complex
- Open Access
- 1 July 2015
- Vol. 11 (4) , 215-219
The effects of occupational noise on blood pressure and heart rate of workers in an automotive parts industry
One of the most important impacts of industrial noise is physiological and psychological effects. The increases in workers’ blood pressure and heart rate were detected during and after exposure to high levels of noise. The objectives of this research were to determine whether the noise exposures have any effects on blood pressure and heart rate of workers in the automotive parts industry. This case study was done in 2011 at different units of an automotive parts manufacturing in Tehran. Sound pressure level was measured at different units of the factory with a calibrated instrument. Demographic features of workers were gathered with an appropriate questionnaire. Heart rate and blood pressure were measured twice in a day in the start time of work day (before exposure to noise) and middle shift hours (during exposure to noise) in the occupational physician office. For analyzing data, chi-square, independent sample t-test, paired t-test, and analysis of covariance (ANCOVA) were used. P < 0.050 was considered statistically significant. The average age of workers in the case and control groups was 35.71 ± 8.10 and 33.40 ± 10.41 years, respectively. There was no difference between the average age of case and control groups (P = 0.436). The results of ANCOVA revealed the significant differences between the mean changes of heart rate F (1, 37) = 26.68, P < 0.001, systolic blood pressure F (1, 37) = 21.70, P < 0.001, and diastolic blood pressure F (1, 37) = 26.20, P < 0.001 of workers in the case and control groups. Exposure to industrial noise may increase the heart rate of workers. Although rises in heart rate, systolic, and diastolic blood pressure of workers in the case group were observed after exposure to noise, the values of heart rate, systolic, and diastolic blood pressure were in the normal range. Further experimental investigations are needed to determine the relationships between these variables.
- 1 July 2015
- Vol. 11 (4) , 215-219
Open AccessThe effects of occupational noise on blood pressure and heart rate of workers in an automotive parts industry
One of the most important impacts of industrial noise is physiological and psychological effects. The increases in workers’ blood pressure and heart rate were detected during and after exposure to high levels of noise. The objectives of this research were to determine whether the noise exposures have any effects on blood pressure and heart rate of workers in the automotive parts industry. This case study was done in 2011 at different units of an automotive parts manufacturing in Tehran. Sound pressure level was measured at different units of the factory with a calibrated instrument. Demographic features of workers were gathered with an appropriate questionnaire. Heart rate and blood pressure were measured twice in a day in the start time of work day (before exposure to noise) and middle shift hours (during exposure to noise) in the occupational physician office. For analyzing data, chi-square, independent sample t-test, paired t-test, and analysis of covariance (ANCOVA) were used. P < 0.050 was considered statistically significant. The average age of workers in the case and control groups was 35.71 ± 8.10 and 33.40 ± 10.41 years, respectively. There was no difference between the average age of case and control groups (P = 0.436). The results of ANCOVA revealed the significant differences between the mean changes of heart rate F (1, 37) = 26.68, P < 0.001, systolic blood pressure F (1, 37) = 21.70, P < 0.001, and diastolic blood pressure F (1, 37) = 26.20, P < 0.001 of workers in the case and control groups. Exposure to industrial noise may increase the heart rate of workers. Although rises in heart rate, systolic, and diastolic blood pressure of workers in the case group were observed after exposure to noise, the values of heart rate, systolic, and diastolic blood pressure were in the normal range. Further experimental investigations are needed to determine the relationships between these variables.
- Open Access
- 1 January 2015
- Vol. 14 (4) , 257-261
Fungal Airborne Contamination as a Serious Threat for Respiratory Infection in the Hematology Ward
Fungi existing in hospital departments may grow and produce micro-colonies. The spores arising from these micro-colonies circulate easily and could be inhaled by patients and cause infections in immune-compromised subjects. Due to the lack of an acceptable method of sampling and evaluation of microbiological quality of air in the isolation units, the purpose of this study was to determine the concentrations of airborne fungi through active and passive sampling and also identify fungi genera in the air of the isolation unit. The air of the isolation unit was monitored through active and passive sampling. In passive sampling, the plates were placed in the room. The active sampling was performed in the hematology unit by using a slit-to-agar biological air sampler with a flow rate of 10 L/minute. Plates were incubated at 30°C for 10 days and were examined daily for fungal growth. Fungal species were identified on the basis of their macroscopic and microscopic morphological features. In active samples, Penicillium spp. was the predominant genus (66.8%), followed by Aspergillus spp. (23.9%) and Cladosporium spp. (2.5%). Yeast spp. accounted for only 2.2% of the isolated fungi. In passive samples, Penicillium spp. (94.4%) was the most frequently found fungi, followed by Aspergillus spp (2.2%), Cladosporium spp. (1.1%) and Yeast spp. (0.5%). The identified genera included Penicillium, Aspergillus, Alternaria, Mucorales, Cladosporium, Yeasts and other filamentous fungi. Active and passive sampling can be used for monitoring the fungal content of air. Assessment of fungal contamination profiles in hospitals may provide important information about the level of fungal concentration in the hospitals and for the control of nosocomial infections. In addition, installation of special ventilation systems equipped with HEPA filters in hematology wards could enhance the quality of air. Also, observing sanitary protocols for disinfection of the surfaces is imperative for infection control.
- 1 January 2015
- Vol. 14 (4) , 257-261
Open AccessFungal Airborne Contamination as a Serious Threat for Respiratory Infection in the Hematology Ward
Fungi existing in hospital departments may grow and produce micro-colonies. The spores arising from these micro-colonies circulate easily and could be inhaled by patients and cause infections in immune-compromised subjects. Due to the lack of an acceptable method of sampling and evaluation of microbiological quality of air in the isolation units, the purpose of this study was to determine the concentrations of airborne fungi through active and passive sampling and also identify fungi genera in the air of the isolation unit. The air of the isolation unit was monitored through active and passive sampling. In passive sampling, the plates were placed in the room. The active sampling was performed in the hematology unit by using a slit-to-agar biological air sampler with a flow rate of 10 L/minute. Plates were incubated at 30°C for 10 days and were examined daily for fungal growth. Fungal species were identified on the basis of their macroscopic and microscopic morphological features. In active samples, Penicillium spp. was the predominant genus (66.8%), followed by Aspergillus spp. (23.9%) and Cladosporium spp. (2.5%). Yeast spp. accounted for only 2.2% of the isolated fungi. In passive samples, Penicillium spp. (94.4%) was the most frequently found fungi, followed by Aspergillus spp (2.2%), Cladosporium spp. (1.1%) and Yeast spp. (0.5%). The identified genera included Penicillium, Aspergillus, Alternaria, Mucorales, Cladosporium, Yeasts and other filamentous fungi. Active and passive sampling can be used for monitoring the fungal content of air. Assessment of fungal contamination profiles in hospitals may provide important information about the level of fungal concentration in the hospitals and for the control of nosocomial infections. In addition, installation of special ventilation systems equipped with HEPA filters in hematology wards could enhance the quality of air. Also, observing sanitary protocols for disinfection of the surfaces is imperative for infection control.