JCJaehoon Chung

Jaehoon Chung

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jaehoon Chung has a total of 57 co-authors. Here are the top co-authors by number of shared publications:

  • Hakho Lee

    Center for Systems Biology, Massachusetts General Hospital, Boston, MA, 02114, USA; Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, 02114, USA

    9 shared publications
  • Ralph Weissleder

    Massachusetts General Hospital

    8 shared publications
  • David Issadore

    Center for Systems Biology, Massachusetts General Hospital, 185 Cambridge St., CPZN 5206, Boston, Massachusetts 02114, USA

    7 shared publications
  • Huilin Shao

    Center for Systems Biology, Massachusetts General Hospital, 185 Cambridge St, CPZN 5206, Boston, Massachusetts 02114, USA

    6 shared publications
  • Monty Liong

    Center for Systems Biology, Massachusetts General Hospital, 185 Cambridge Street, CPZN 5206, Boston, Massachusetts 02114, United States

    4 shared publications
  • Ralph Weissleder

    Center for Systems Biology, Massachusetts General Hospital, 185 Cambridge Street, CPZN 5206, Boston, Massachusetts 02114, United States

    4 shared publications

Latest Publications

  • Open Access

    Nanoparticle Detection of Urinary Markers for Point-of-Care Diagnosis of Kidney Injury

    by Hyun Jung Chung, Kathryn L. Pellegrini, Jaehoon Chung, Kamani Wanigasuriya, Innocent Jayawardene, Kyungheon Lee, Hakho Lee, Vishal S. Vaidya, Ralph Weissleder

    The high incidence of acute and chronic kidney injury due to various environmental factors such as heavy metals or chemicals has been a major problem in developing countries. However, the diagnosis of kidney injury in these areas can be more challenging due to the lack of highly sensitive and specific techniques that can be applied in point-of-care settings. To address this, we have developed a technique called ‘micro-urine nanoparticle detection (μUNPD)’, that allows the detection of trace amounts of molecular markers in urine. Specifically, this technique utilizes an automated on-chip assay followed by detection with a hand-held device for the read-out. Using the μUNPD technology, the kidney injury markers KIM-1 and Cystatin C were detected down to concentrations of 0.1 ng/ml and 20 ng/ml respectively, which meets the cut-off range required to identify patients with acute or chronic kidney injury. Thus, we show that the μUNPD technology enables point of care and non-invasive detection of kidney injury, and has potential for applications in diagnosing kidney injury with high sensitivity in resource-limited settings.


  • Portable Coulter counter with vertical through-holes for high-throughput applications

    by Yu Chen, Seong-Jin Kim, Jinhong Guo, Yuejun Kang, Jaya P. Kausalya, Alicia Ghia Min Ong, Walter Hunziker, Jaehoon Chung


  • Top Cited Papers
    Open Access

    Chip-based analysis of exosomal mRNA mediating drug resistance in glioblastoma

    by Huilin Shao, Jaehoon Chung, Kyungheon Lee, Leonora Balaj, Changwook Min, Bob S. Carter, Fred H. Hochberg, Xandra O. Breakefield, Hakho Lee, Ralph Weissleder

    Real-time monitoring of drug efficacy in glioblastoma multiforme (GBM) is a major clinical problem as serial re-biopsy of primary tumours is often not a clinical option. MGMT (O6-methylguanine DNA methyltransferase) and APNG (alkylpurine-DNA-N-glycosylase) are key enzymes capable of repairing temozolomide-induced DNA damages and their levels in tissue are inversely related to treatment efficacy. Yet, serial clinical analysis remains difficult, and, when done, primarily relies on promoter methylation studies of tumour biopsy material at the time of initial surgery. Here we present a microfluidic chip to analyse mRNA levels of MGMT and APNG in enriched tumour exosomes obtained from blood. We show that exosomal mRNA levels of these enzymes correlate well with levels found in parental cells and that levels change considerably during treatment of seven patients. We propose that if validated on a larger cohort of patients, the method may be used to predict drug response in GBM patients.


  • Traceable clonal culture and chemodrug assay of heterogeneous prostate carcinoma PC3 cells in microfluidic single cell array chips

    by Jaehoon Chung, Patrick N. Ingram, Tom Bersano-Begey, Euisik Yoon

    Cancer heterogeneity has received considerable attention for its role in tumor initiation and progression, and its implication for diagnostics and therapeutics in the clinic. To facilitate a cellular heterogeneity study in a low cost and highly efficient manner, we present a microfluidic platform that allows traceable clonal culture and characterization. The platform captures single cells into a microwell array and cultures them for clonal expansion, subsequently allowing on-chip characterization of clonal phenotype and response against drug treatments. Using a heterogeneous prostate cancer model, the PC3 cell line, we verified our prototype, identifying three different sub-phenotypes and correlating their clonal drug responsiveness to cell phenotype.


  • Open Access

    Ascites analysis by a microfluidic chip allows tumor-cell profiling

    by Vanessa M. Peterson, Cesar M. Castro, Jaehoon Chung, Nathan C. Miller, Adeeti V. Ullal, Maria D. Castano, Richard T. Penson, Hakho Lee, Michael J. Birrer, Ralph Weissleder

    Ascites tumor cells (ATCs) represent a potentially valuable source of cells for monitoring treatment of ovarian cancer as it would obviate the need for more invasive surgical biopsies. The ability to perform longitudinal testing of ascites in a point-of-care setting could significantly impact clinical trials, drug development, and clinical care. Here, we developed a microfluidic chip platform to enrich ATCs from highly heterogeneous peritoneal fluid and then perform molecular analyses on these cells. We evaluated 85 putative ovarian cancer protein markers and found that nearly two-thirds were either nonspecific for malignant disease or had low abundance. Using four of the most promising markers, we prospectively studied 47 patients (33 ovarian cancer and 14 control). We show that a marker set (ATCdx) can sensitively and specifically map ATC numbers and, through its reliable enrichment, facilitate additional treatment-response measurements related to proliferation, protein translation, or pathway inhibition. Significance Serial molecular analyses of tumor cells during treatment- and biopsy-driven clinical trials are emerging norms for many cancers. Yet surgical and image-guided biopsies are expensive and invasive, explaining why alternative sources for tumor cells are being sought. In ovarian cancer (and other abdominopelvic cancers), abdominal fluid buildup (ascites) occurs frequently. We demonstrate that ascites tumor cells (ATCs) present a valuable source of tumor cells, rendering ascites another form of “liquid biopsy.” We evaluated 85 ovarian cancer-related markers and developed a unique, low cost miniaturized microfluidic ATC chip for on-chip enrichment and molecular profiling using small amounts of ascites. This approach could expand the utility of ATCs within cytotoxic and/or molecularly targeted ovarian cancer therapeutic trials.


  • Magnetic Nanosensor for Detection and Profiling of Erythrocyte-Derived Microvesicles

    by Junsung Rho, Jaehoon Chung, Hyungsoon Im, Monty Liong, Huilin Shao, Cesar M. Castro, Ralph Weissleder, Hakho Lee

    During the course of their lifespan, erythrocytes actively shed phospholipid-bound microvesicles (MVs). In stored blood, the number of these erythrocyte-derived MVs has been observed to increase over time, suggesting their potential value as a quality metric for blood products. The lack of sensitive, standardized MV assays, however, poses a significant barrier to implementing MV analyses into clinical settings. Here, we report on a new nanotechnology platform capable of rapid and sensitive MV detection in packed red blood cell (pRBC) units. A filter-assisted microfluidic device was designed to enrich MVs directly from pRBC units, and label them with target-specific magnetic nanoparticles. Subsequent detection using a miniaturized nuclear magnetic resonance system enabled accurate MV quantification as well as the detection of key molecular markers (CD44, CD47, CD55). When the developed platform was applied, MVs in stored blood units could also be monitored longitudinally. Our results showed that MV counts increase over time and, thus, could serve as an effective metric of blood aging. Furthermore, our studies found that MVs have the capacity to generate oxidative stress and consume nitric oxide. By advancing our understanding of MV biology, we expect that the developed platform will lead to improved blood product quality and transfusion safety.


  • Rare cell isolation and profiling on a hybrid magnetic/size-sorting chip

    by Jaehoon Chung, David Issadore, Adeeti Ullal, Kyungheon Lee, Ralph Weissleder, Hakho Lee

    We present a hybrid magnetic/size-sorting (HMSS) chip for isolation and molecular analyses of circulating tumor cells (CTCs). The chip employs both negative and positive cell selection in order to provide high throughput, unbiased CTC enrichment. Specifically, the system utilizes a self-assembled magnet to generate high magnetic forces and a weir-style structure for cell sorting. The resulting device thus can perform multiple functions, including magnetic depletion, size-selective cell capture, and on-chip molecular staining. With such capacities, the HMSS device allowed one-step CTC isolation and single cell detection from whole blood, tested with spiked cancer cells. The system further facilitated the study of individual CTCs for heterogeneity in molecular marker expression.


  • Open Access

    Miniaturized nuclear magnetic resonance platform for detection and profiling of circulating tumor cells

    by Cesar M. Castro, Arezou A. Ghazani, Jaehoon Chung, Huilin Shao, David Issadore, Tae-Jong Yoon, Ralph Weissleder, Hakho Lee

    Accurate detection and profiling of circulating tumor cells (CTCs) is a highly sought after technology to improve cancer management. Such “liquid biopsies” could offer a non-invasive, repeatable window into each patient's tumor, facilitating early cancer diagnosis and treatment monitoring. The rarity of CTCs, approximated at 1 CTC for every billion peripheral blood cells, however, poses significant challenges to sensitive and reliable detection. We have recently developed a new micro-nuclear magnetic resonance (μNMR) platform for biosensing. Through the synergistic integration of microfabrication, nanosensors, and novel chemistries, the μNMR platform offers high detection sensitivity and point-of-care operation, overcoming technical barriers in CTC research. We herein review the μNMR technology with emphasis on its application to CTC detection. Recent advances in the sensing technology will be summarized, followed by the description of the dynamic interplay between our preclinical and clinical CTC studies.


  • Open Access

    Magnetic barcode assay for genetic detection of pathogens

    by Monty Liong, Anh N. Hoang, Jaehoon Chung, Nil Gural, Christopher B. Ford, Changwook Min, Rupal R. Shah, Rushdy Ahmad, Marta Fernandez-Suarez, Sarah M. Fortune, et al.

    The task of rapidly identifying patients infected with Mycobacterium tuberculosis in resource-constrained environments remains a challenge. A sensitive and robust platform that does not require bacterial isolation or culture is critical in making informed diagnostic and therapeutic decisions. Here we introduce a platform for the detection of nucleic acids based on a magnetic barcoding strategy. PCR-amplified mycobacterial genes are sequence-specifically captured on microspheres, labelled by magnetic nanoprobes and detected by nuclear magnetic resonance. All components are integrated into a single, small fluidic cartridge for streamlined on-chip operation. We use this platform to detect M. tuberculosis and identify drug-resistance strains from mechanically processed sputum samples within 2.5 h. The specificity of the assay is confirmed by detecting a panel of clinically relevant non-M. tuberculosis bacteria, and the clinical utility is demonstrated by the measurements in M. tuberculosis-positive patient specimens. Combined with portable systems, the magnetic barcode assay holds promise to become a sensitive, high-throughput and low-cost platform for point-of-care diagnostics.


  • μHall Chip for Sensitive Detection of Bacteria

    by David Issadore, Hyun Jung Chung, Jaehoon Chung, Ghyslain Budin, Ralph Weissleder, Hakho Lee

    Sensitive, rapid and phenotype‐specific enumeration of pathogens is essential for the diagnosis of infectious disease, monitoring of food chains, and for defense against bioterrorism. Microbiological culture and genotyping, techniques that sensitively and selectively detect bacteria in laboratory settings, have limited application in clinical environments due to high cost, slow response times, and the need for specially trained staff and laboratory infrastructure. To address these challenges, we developed a microfluidic chip‐based micro‐Hall (μHall) platform capable of measuring single, magnetically tagged bacteria directly in clinical specimens with minimal sample processing. We demonstrated the clinical utility of the μHall chip by enumerating Gram‐positive bacteria. The overall detection limit of the system was similar to that of culture tests (∼10 bacteria), but the assay time was 50‐times faster. This low‐cost, single‐cell analytical technique is especially well‐suited to diagnose infectious diseases in resource‐limited clinical settings.