LKLee K. Kimbell

Lee K. Kimbell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lee K. Kimbell has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impact of corrosion inhibitors on antibiotic resistance, metal resistance, and microbial communities in drinking water

    by Lee K. Kimbell, Emily Lou LaMartina, Stan Kohls, Yin Wang, Ryan J. Newton, Patrick J. McNamara

    Corrosion inhibitors, including zinc orthophosphate, sodium orthophosphate, and sodium silicate, are commonly used to prevent the corrosion of drinking water infrastructure. Metals such as zinc are known stressors for antibiotic resistance selection, and phosphates can increase microbial growth in drinking water distribution systems (DWDS). Yet, the influence of corrosion inhibitor type on antimicrobial resistance in DWDS is unknown. Here, we show that sodium silicates can decrease antibiotic resistant bacteria (ARB) and antibiotic-resistance genes (ARGs), while zinc orthophosphate increases ARB and ARGs in source water microbial communities. Based on controlled bench-scale studies, zinc orthophosphate addition significantly increased the abundance of ARB resistant to ciprofloxacin, sulfonamides, trimethoprim, and vancomycin, as well as the genes sul1 , qac EΔ1, an indication of resistance to quaternary ammonium compounds, and the integron-integrase gene intI 1. In contrast, sodium silicate dosage at 10 mg/L resulted in decreased bacterial growth and antibiotic resistance selection compared to the other corrosion inhibitor additions. Source water collected from the drinking water treatment plant intake pipe resulted in less significant changes in ARB and ARG abundance due to corrosion inhibitor addition compared to source water collected from the pier at the recreational beach. In tandem with the antibiotic resistance shifts, significant microbial community composition changes also occurred. Overall, the corrosion inhibitor sodium silicate resulted in the least selection for antibiotic resistance, which suggests it is the preferred corrosion inhibitor option for minimizing antibiotic resistance proliferation in DWDS. However, the selection of an appropriate corrosion inhibitor must also be appropriate for the water chemistry of the system (e.g., pH, alkalinity) to minimize metal leaching first and foremost and to adhere to the lead and copper rule. IMPORTANCE: Antibiotic resistance is a growing public health concern across the globe and was recently labeled the silent pandemic. Scientists aim to identify the source of antibiotic resistance and control points to mitigate the spread of antibiotic resistance. Drinking water is a direct exposure route to humans and contains antibiotic-resistant bacteria and associated resistance genes. Corrosion inhibitors are added to prevent metallic pipes in distribution systems from corroding, and the type of corrosion inhibitor selected could also have implications on antibiotic resistance. Indeed, we found that sodium silicate can minimize selection of antibiotic resistance while phosphate-based corrosion inhibitors can promote antibiotic resistance. These findings indicate that sodium silicate is a preferred corrosion inhibitor choice for mitigation of antibiotic resistance.


  • Open Access

    Targeting current and future threats: recent methodological trends in environmental antimicrobial resistance research and their relationships to risk assessment

    by Tucker R. Burch, Ryan J. Newton, Lee K. Kimbell, Emily Lou LaMartina, Kassidy O'MAlley, San Marie Thomson, Christopher W. Marshall, Patrick J. McNamara

    Antimicrobial resistance (AMR) is a growing public health threat. Improved surveillance of AMR's genetic indicators in environmental reservoirs should lead to a more comprehensive understanding of the problem at a global scale, as with SARS-CoV-2 monitoring in sewage. However, the “best” monitoring approach is unclear. Some scientific works have emphasized monitoring for the abundance of already-known antimicrobial resistance genes (ARGs); others have emphasized monitoring for the potential of new ARGs to arise. The goal of this study was to examine which methods were employed by highly-cited papers studying AMR in environmental engineering and agricultural systems, thus providing insight into current and future methodological trends for monitoring ARGs. We searched recent (2018–2020) literature documenting AMR in five environmental matrices: wastewater, surface water, drinking water, stormwater, and livestock manure. We selected the most highly-cited papers across these matrices (89 papers from 17 809 initial results) and categorized them as using targeted methods (e.g., qPCR), non-targeted methods (e.g., shotgun metagenomics), or both. More than 80% of papers employed targeted methods. Only 33% employed non-targeted methods, and the use of targeted versus non-targeted methods varied by environmental matrix. We posit that improving AMR surveillance in environmental reservoirs requires assessing risk, and that different monitoring approaches imply different objectives for risk assessment. Targeted methods are appropriate for quantifying known threats, particularly in environmental matrices where direct human exposure is likely (e.g., drinking water). However, long-term studies employing non-targeted methods are needed to provide an understanding of how frequently new threats (i.e., novel ARGs) arise.


  • Open Access

    Cast iron drinking water pipe biofilms support diverse microbial communities containing antibiotic resistance genes, metal resistance genes, and class 1 integrons

    by Lee K. Kimbell, Emily Lou LaMartina, Anthony D. Kappell, Jingwan Huo, Yin Wang, Ryan J. Newton, Patrick J. McNamara

    Antimicrobial resistance is a well-documented public health concern. The role that drinking water distribution pipes have as sources of antibiotic resistance genes (ARGs) is not well known. Metals are a known stressor for antibiotic resistance development, implying that aging metal-pipe infrastructure could be a source of ARGs. The objective of this study was to determine if ARGs, metal resistance genes (MRGs), and intI1 were pervasive across various pipe biofilm sample types (biomass surfaces, pipe surfaces, corrosion tubercles, and under corrosion tubercles) and if the resistance genes associated with particular microbial taxa. Eight sample types in triplicate (n = 24) were taken from inside a >100 year-old, six ft. section of a full-scale chloraminated cast iron drinking water main. Droplet digital PCR (ddPCR) was employed as a novel approach to quantify ARGs in pipes from full-scale drinking water distribution systems (DWDS) because it yielded higher detection frequencies than quantitative PCR (qPCR). Illumina sequencing was employed to characterize the microbial community based on 16S rRNA genes. ARGs and MRGs were detected in all 24 pipe samples. Every sample contained targeted genes. Interestingly, the mean absolute abundances of ARGs and MRGs only varied by approximately one log value across sample types, but the mean relative abundances (copy numbers normalized to 16S rRNA genes) varied by over two log values. The ARG and MRGs concentrations were not significantly different between sample types, despite significant changes in dominant microbial taxa. The most abundant genera observed in the biofilm communities were Mycobacterium (0.2–70%), and β-lactam resistance genes blaTEM, blaSHV, and the integrase gene of class 1 integrons (intI1) were positively correlated with Mycobacterium. The detection of ARGs, MRGs, and class 1 integrons across all sample types within the pipe indicates that pipes themselves can serve as sources for ARGs in DWDS. Consequently, future work should investigate the role of pipe materials as well as corrosion inhibitors to determine how engineering decisions can mitigate ARGs in drinking water that stem from pipe materials.


  • The impact of metal pipe materials, corrosion products, and corrosion inhibitors on antibiotic resistance in drinking water distribution systems

    by Lee K. Kimbell, Yin Wang, Patrick J. McNamara

    Drinking water distribution systems (DWDS) are unique engineering environments that are important routes for the acquisition and dissemination of antibiotic resistance. Antibiotic-resistant bacteria (ARB) and antibiotic resistance genes (ARGs) in drinking water pose risks to human and environmental health. Metals are known stressors that can select for antibiotic resistance. The objective of this review was to assess the state of knowledge regarding the impact of metal pipe materials, corrosion products, and corrosion inhibitors on the prevalence of antibiotic resistance in DWDS. ARGs and mobile genetic elements (MGEs) have been detected in full-scale DWDS in concentrations ranging from ~ 101 to 1010 copies/L. Metal pipe materials can select for bacteria harboring ARGs and metal resistance genes (MRGs) through co-selection processes. Corrosion products that develop in metal drinking water pipes (Cu, Fe, and Pb oxides) may also stimulate antibiotic resistance selection during distribution. Different corrosion inhibitor regimes (phosphates, sodium silicates) may also have impacts on microbial communities and the abundance of resistance genes in DWDS. Research is needed to quantify how engineering decisions related to drinking water infrastructure and corrosion inhibitor practices impact the abundance and distribution of ARG, MRGs, and MGEs in potable water systems. Key points • Lack of quantitative measurements of antibiotic and metal resistance genes in drinking water distribution systems. • Pipe materials and corrosion products that develop in pipe scales may impact antibiotic resistance. • Corrosion inhibitors with zinc or phosphate could alter antibiotic resistance. • Management decisions should consider antibiotic resistance ramifications. Graphical abstract


  • Open Access

    Removal of antibiotic resistance genes in an anaerobic membrane bioreactor treating primary clarifier effluent at 20 °C

    by Anthony D. Kappell, Lee K. Kimbell, Matthew D. Seib, Daniel E. Carey, Melinda J. Choi, Tino Kalayil, Masanori Fujimoto, Daniel H. Zitomer, Patrick J. McNamara

    Anaerobic membrane bioreactors (AnMBR) play a key role in future plans for sustainable wastewater treatment and resource recovery because they have no energy-intensive oxygen transfer requirements and can produce biomethane for renewable energy. Recent research results show that they can meet relatively stringent discharge limits with respect to BOD5 and TSS when treating municipal wastewater primary effluent. Sustainable used water recovery plans should also consider removal of unregulated pollutants. Antibiotic resistance genes (ARGs) represent an important emerging contaminant due to public health concerns surrounding the spread of infections resistant to common antibiotics. Conventional activated sludge processes have demonstrated mixed results regarding ARG removal. The objective of this research was to determine the impact of an AnMBR on ARG removal when treating municipal primary clarifier effluent at 20 °C. AnMBR treatment resulted in 3.3 to 3.6 log reduction of ARG and the horizontal gene transfer determinate, intI1, copies in filtrate. Membrane treatment significantly decreased the total biomass as indicated by a decrease in 16S rRNA gene concentration. Microbial community analysis via Illumina sequencing revealed that the relative abundance of putative pathogens was higher in membrane filtrate compared to primary effluent although the overall bacterial 16S rRNA gene concentrations was lower in filtrate. Membrane treatment also substantially reduced microbial diversity in filtrate compared to anaerobic reactor contents.


  • Effect of pyrolysis on the removal of antibiotic resistance genes and class I integrons from municipal wastewater biosolids

    by Lee K. Kimbell, Anthony D. Kappell, Patrick J. McNamara

    Wastewater biosolids represent a significant reservoir of antibiotic resistance genes (ARGs). While current biosolids treatment technologies can reduce ARG levels in residual wastewater biosolids, observed removal rates vary substantially. Pyrolysis is an anoxic thermal degradation process that can be used to convert biosolids into energy rich products including py-gas and py-oil, and a beneficial soil amendment, biochar. Batch pyrolysis experiments conducted on municipal biosolids revealed that the 16S rRNA gene, the ARGs erm(B), sul1, tet(L), tet(O), and the integrase gene of class 1 integrons (intI1) were significantly reduced at pyrolysis temperatures ranging from 300–700 °C, as determined by quantitative polymerase chain reaction (qPCR). Pyrolysis of biosolids at 500 °C and higher resulted in approximately 6-log removal of the bacterial 16S rRNA gene. ARGs with the highest observed removals were sul1 and tet(O), which had observed reductions of 4.62 and 4.04-log, respectively. Pyrolysis reaction time had a significant impact on 16S rRNA, ARG and intI1 levels. A pyrolysis residence time of 5 minutes at 500 °C reduced all genes to below detection limits. These results demonstrate that pyrolysis could be implemented as a biosolids polishing treatment technology to substantially decrease the abundance of total bacteria (i.e., 16S rRNA), ARGs and intI1 prior to land application of municipal biosolids.