PHPetr Honzík

Petr Honzík

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Petr Honzík has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Antonin Novak

    Laboratoire d'Acoustique de l'Université du Mans, Unité Mixte de Recherche 6613, Institut d'Acoustique–Graduate School, CNRS, Le Mans Université 1 , Le Mans

    6 shared publications
  • Michel Bruneau

    6 shared publications
  • Michel Bruneau

    Laboratoire d'Acoustique de l'Université du Maine, Avenue Olivier Messiaen, 72085 Le Mans, France

    4 shared publications
  • Nicolas Joly

    LUNAM Université, LAUM (Laboratoire d'acoustique de l'université du Maine), UMR CNRS 6613 , Avenue Olivier Messiaen, F-72085 Le Mans, France

    4 shared publications
  • Stéphane Durand

    LUNAM Université, LAUM (Laboratoire d'acoustique de l'université du Maine), UMR CNRS 6613 , Avenue Olivier Messiaen, F-72085 Le Mans, France

    4 shared publications
  • Karina Šimonová

    Department of Radioelectronics, Faculty of Electrical Engineering, Czech Technical University in Prague , Technická 2, Praha 166 27

    3 shared publications

Latest Publications

  • Open Access

    Free vibrations of fully clamped rectangular plates: data-driven closed-form approximation of eigenmodes and eigenfrequencies

    by Aneta Furmanová, Petr Honzík, Viktor Hruška, Pierrick Lotton

    Thin diaphragms, modelled as a rectangular plate fully clamped, are frequently used in modern MEMS microphones. Despite the prevalence of these devices, the free vibration analysis of such structures lacks an exact analytical solution, and explicit mathematical descriptions of the underlying physics. This paper addresses these challenges by providing analytical approximations for the eigenfrequencies and bending eigenmodes of fully clamped rectangular plates.Using a data-driven discovery approach based on physics-informed symbolic regression, closed-form approximations are obtained from finite-element method simulation data.The approximations predict eigenfrequencies within 5.5\% relative error and fundamental mode shapes within 3.0\% relative error (aspect ratios up to 1.7). The obtained equations capture the expected modal interactions and mode inseparability dictated by the clamped boundary conditions -- phenomena absent in simply supported plates. These closed-form expressions explicitly show how geometric parameters directly influence the vibrational behavior, enabling direct parametric design, and optimization of MEMS transducer diaphragms without repeated finite-element simulations.

  • Open Access

    Free vibrations of fully clamped rectangular plates: data-driven closed-form approximation of eigenmodes and eigenfrequencies

    by Aneta Furmanová, Petr Honzík, Viktor Hruška, Pierrick Lotton

    Thin diaphragms, modelled as a rectangular plate fully clamped, are frequently used in modern MEMS microphones. Despite the prevalence of these devices, the free vibration analysis of such structures lacks an exact analytical solution, and explicit mathematical descriptions of the underlying physics. This paper addresses these challenges by providing analytical approximations for the eigenfrequencies and bending eigenmodes of fully clamped rectangular plates. Using a data-driven discovery approach based on physics-informed symbolic regression, closed-form approximations are obtained from finite-element method simulation data. The approximations predict eigenfrequencies within 5.5% relative error and fundamental mode shapes within 3.0% relative error (aspect ratios up to 1.7). The obtained equations capture the expected modal interactions and mode inseparability dictated by the clamped boundary conditions - phenomena absent in simply supported plates. These closed-form expressions explicitly show how geometric parameters directly influence the vibrational behavior, enabling direct parametric design, and optimization of MEMS transducer diaphragms without repeated finite-element simulations.

  • Dual membrane condenser microphones: Post-processing strategies for nonlinear distortion reduction

    by Antonin Novak, Petr Honzík

    This paper studies nonlinear distortion in a dual membrane condenser microphone and evaluates three post-processing methods for reducing residual second-harmonic distortion. A nonlinear capacitance model is developed using two asymmetry parameters that represent electrostatic sensitivity mismatch and geometric gap mismatch between branches. The model predicts partial intrinsic cancellation of quadratic distortion in the differential signal, with residual distortion governed by branch asymmetries. Three correction strategies are analyzed: branch-wise correction before recombination, direct correction of the differential signal, and weighted branch combination. Experiments are performed on a dual membrane micro-electro-mechanical systems microphone using a low distortion acoustic excitation setup with harmonic feedback control. All three methods show significant reduction of the second-harmonic distortion in the differential output of approximately 35–40 dB in the measured 110–125 dB SPL range. Practical aspects of distortion reduction in dual membrane micro-electro-mechanical systems microphones are discussed, including issues related to specific microphone geometry and parameter estimation.

  • Linearization of condenser microphones under non-ideal laboratory conditions using a two-speaker setup

    by Antonin Novak, Petr Honzík

    This paper demonstrates that the nonlinear distortion of capacitive microphones, including the vast majority of micro-electromechanical systems, studio condenser designs, and laboratory measurement microphones, can be characterized and linearized in a simple laboratory environment. The proposed setup requires only two off-the-shelf loudspeakers, a low-cost amplifier, and a sound card to generate and analyze the signals. By driving each loudspeaker with a harmonic signal at a different frequency, the microphone's internal quadratic nonlinearity is isolated through second-order intermodulation products. This allows the characteristic parameter required for post-processing linearization to be calculated directly from the recorded signal without requiring proprietary manufacturer data, high-end laboratory speakers, or a specialized method for source linearization with a reference measurement microphone. The paper provides the mathematical derivation for this source-independent estimation, demonstrates its scale invariance for both analog and digital-output microphones, and validates the approach against high-precision laboratory standards. Results show that the identified parameter remains stable across a wide dynamic range, providing an accurate and robust solution for real-time microphone linearization in practical and field-testing environments.

  • Analytical modeling of condenser microphones with nonuniform acoustic excitation and backplate perforation patterns

    by Karina Šimonová, Petr Honzík

    The present study develops an analytical model for predicting the response of condenser microphones subjected to a plane wave incident pressure field arriving from an arbitrary direction while explicitly accounting for the exact perforation pattern of the backplate. The model describes the coupled vibration of a clamped circular membrane and acoustic pressure in the air gap and incorporates thermoviscous losses. Analytical predictions are compared with reference three-dimensional finite-element simulations. The comparison includes membrane displacement fields, air-gap pressure distributions, frequency-dependent mean displacements, and—for transducers with a segmented backplate—the mean displacement differences between opposing segments and the resulting polar directivity patterns. Across a broad frequency range, including frequencies above the first membrane resonance, the analytical model shows very good agreement with the numerical reference. The results demonstrate that the framework reliably captures the influence of arbitrary backplate perforation geometries and nonuniform acoustic excitation on the microphone response.

  • Nonlinear capacitance and distortion reduction in dual backplate condenser microphones

    by Petr Honzík, Antonin Novak

    Dual backplate microphones have gained attention for their ability to improve sensitivity and dynamic range and suppress even-order harmonic distortion compared to traditional single backplate designs. This study investigates the nonlinear behavior of these microphones, focusing on the nonlinear capacitance changes that occur as the diaphragm moves between the two backplates. A theoretical model is developed to describe how asymmetries in the air gaps and parasitic capacities contribute to harmonic distortion. The results show that the second harmonic decreases significantly as the air gaps and the parasitic capacities become more symmetrical, confirming that the dual backplate structure can effectively cancel even-order harmonics. The model is then validated through acoustic measurements on a dual backplate micro-electro-mechanical systems microphone, from which the key model parameters are estimated. In addition, a signal-domain correction algorithm—originally designed for single backplate microphones—is adapted and shown to reduce distortion further when applied to dual backplate designs. These findings provide both a clearer understanding of nonlinear distortion mechanisms in dual backplate microphones and a practical means to improve their performance in high-demand acoustic applications.


  • Reduction of nonlinear distortion in condenser microphones using a simple post-processing technique

    by Petr Honzík, Antonin Novak

    In this paper, an approach for effectively reducing nonlinear distortion in single-backplate condenser microphones is introduced, i.e., most microelectromechanical systems (MEMS) microphones, studio recording condenser microphones, and laboratory measurement microphones. This simple post-processing technique can be easily integrated on external hardware such as an analog circuit, microcontroller, audio codec, digital signal processing unit, or within the Application Specific Integrated Circuit chip in a case of MEMS microphones. It effectively reduces microphone distortion across its frequency and dynamic range, and relies on a single parameter, which can be derived from either the microphone's physical parameters or a straightforward measurement presented in this paper. An optimal estimate of this parameter achieves the best distortion reduction, whereas overestimating it never increases distortion beyond the original level. The technique was tested on a MEMS microphone. The findings indicate that for harmonic excitation, the proposed technique reduces the second harmonic by approximately 40 dB, leading to an effective reduction in the total harmonic distortion. The efficiency of the distortion reduction technique for more complex signals is demonstrated through two-tone and multitone experiments, where second-order intermodulation products are reduced by at least 20 dB.


  • Open Access

    Editorial for the Special Issue on Micromachined Acoustic Transducers for Audio-Frequency Range

    by Libor Rufer, Shubham Shubham, Haoran Wang, Tom Miller, Petr Honzík, Vittorio Ferrari

    Microelectromechanical systems (MEMS) refer to miniaturized mechanical and electro-mechanical elements that are fabricated through microelectronic processes


  • Open Access

    Reduction of Nonlinear Distortion in Condenser Microphones Using a Simple Post-Processing Technique

    by Petr Honzík, Antonin Novak

    In this paper, we introduce a novel approach for effectively reducing nonlinear distortion in single back-plate condenser microphones, i.e., most MEMS microphones, studio recording condenser microphones, and laboratory measurement microphones. This simple post-processing technique can be easily integrated on an external hardware such as an analog circuit, microcontroller, audio codec, DSP unit, or within the ASIC chip in a case of MEMS microphones. It significantly reduces microphone distortion across its frequency and dynamic range. It relies on a single parameter, which can be derived from either the microphone's physical parameters or a straightforward measurement presented in this paper. An optimal estimate of this parameter achieves the best distortion reduction, whereas overestimating it never increases distortion beyond the original level. The technique was tested on a MEMS microphone. Our findings indicate that for harmonic excitation the proposed technique reduces the second harmonic by approximately 40 dB, leading to a significant reduction in the Total Harmonic Distortion (THD). The efficiency of the distortion reduction technique for more complex signals is demonstrated through two-tone and multitone experiments, where second-order intermodulation products are reduced by at least 20 dB.