Cheng-Fa Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Cheng-Fa Lee has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Yeou-Lih Huang
Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, Kaohsiung, Taiwan
4 shared publications Keng-Chang Hsu
Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, Kaohsiung 807, Taiwan
3 shared publicationsChih-Chang Hung
Research Center for Environmental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
2 shared publications- Bai-Hsiun Chen
Department of Laboratory Medicine, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
1 shared publication Chien-Hua Chiang
Department of Medical Laboratory Science and Biotechnology
1 shared publicationChing-Chiang Lin
Planning Department, Fooyin University Hospital, Pingtung, Taiwan; Department of Medical Laboratory Science and Biotechnology, Fooyin University, Kaohsiung, Taiwan
1 shared publication
Latest Publications
- 29 September 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (11) , 2338-2345
Ultrasound-assisted hollow fiber/ionic liquid-based liquid phase microextraction using an ionic liquid solvent for preconcentration of cobalt and nickel ions in urine samples prior to FAAS determination
Ultrasound-assisted (UA) hollow fiber (HF) liquid-phase microextraction (LPME) coupled with flame atomic absorption spectrometry (FAAS) has been developed to preconcentrate and determine ultra-trace amounts of cobalt (Co) and nickel (Ni) ions in human urine. To the best of our knowledge, no previous reports have described the coupling of UA-ionic liquid (IL)-HF-LPME with an FAAS system to analyze metal ions in biological samples. In this study, the ILs 1-hexyl-3-methylimidazolium hexafluorophosphate, sodium hexafluorophosphate, and 1-(2-pyridylazo)-2-naphthol were used as extraction, ion-pairing, and chelating agents, respectively. With the assistance of an ultrasonic probe, the analyte exchange between the phases increased, and the extraction efficiency of Co and Ni ions improved significantly. The collected extraction phase was subsequently analyzed directly through FAAS. Under optimized conditions, the detection limits of Co and Ni ions were 0.09 and 0.03 μg L−1, respectively. The precision of the analysis of Co and Ni ions was within a relative standard deviation of 10% under normal operating conditions. The ultrasonic assistance provided enrichment factors of 66 and 82 for Co and Ni ions, respectively. The recoveries of Co and Ni ions spiked in urine samples ranged from 93.8 to 104.3%. The practicality of the proposed method was demonstrated through satisfactory analyses of samples of a standard reference material and real human urine.
- 29 September 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (11) , 2338-2345
Ultrasound-assisted hollow fiber/ionic liquid-based liquid phase microextraction using an ionic liquid solvent for preconcentration of cobalt and nickel ions in urine samples prior to FAAS determination
Ultrasound-assisted (UA) hollow fiber (HF) liquid-phase microextraction (LPME) coupled with flame atomic absorption spectrometry (FAAS) has been developed to preconcentrate and determine ultra-trace amounts of cobalt (Co) and nickel (Ni) ions in human urine. To the best of our knowledge, no previous reports have described the coupling of UA-ionic liquid (IL)-HF-LPME with an FAAS system to analyze metal ions in biological samples. In this study, the ILs 1-hexyl-3-methylimidazolium hexafluorophosphate, sodium hexafluorophosphate, and 1-(2-pyridylazo)-2-naphthol were used as extraction, ion-pairing, and chelating agents, respectively. With the assistance of an ultrasonic probe, the analyte exchange between the phases increased, and the extraction efficiency of Co and Ni ions improved significantly. The collected extraction phase was subsequently analyzed directly through FAAS. Under optimized conditions, the detection limits of Co and Ni ions were 0.09 and 0.03 μg L−1, respectively. The precision of the analysis of Co and Ni ions was within a relative standard deviation of 10% under normal operating conditions. The ultrasonic assistance provided enrichment factors of 66 and 82 for Co and Ni ions, respectively. The recoveries of Co and Ni ions spiked in urine samples ranged from 93.8 to 104.3%. The practicality of the proposed method was demonstrated through satisfactory analyses of samples of a standard reference material and real human urine.
- 1 August 2016
- Published by Elsevier in Clinical Nutrition
- Vol. 35 (4) , 880-884
Magnesium, zinc, and chromium levels in children, adolescents, and young adults with type 1 diabetes
- 1 August 2016
- Published by Elsevier in Clinical Nutrition
- Vol. 35 (4) , 880-884
Magnesium, zinc, and chromium levels in children, adolescents, and young adults with type 1 diabetes
- 3 October 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 4 (93) , 51716-51721
Combining microdialysis sampling and inductively coupled plasma mass spectrometry for dynamic monitoring of trace metal ions during bacterial growth periods
Monitoring the dynamic variations of trace metal ions allows us to understand their roles in basic cellular functions and also in microbial-mediated detoxification of metal pollutants. The objective of this study was to develop an easily operated, simultaneous, and continuous method for dynamic monitoring of trace metal ions during bacterial growth periods. Here, we used a microdialysis (MD) sampling technique combined with detection through inductively coupled plasma mass spectrometry (ICP-MS) to determine and quantify trace metal ions. After optimization, we used a retrodialysis technique and a no-net-flux method to assess the probe recovery and analytical performance of the proposed system. The mean probe recoveries of cobalt, copper, strontium, cadmium, and lead were 64.4, 92.6, 40.8, 84.2, and 54.7%, respectively, with typical precision values of 0.5–6.2, 1.1–7.7, 2.0–6.3, 2.3–7.8, and 1.5–7.8%, respectively. To further evaluate the practical applicability of using our proposed MD/ICP-MS method, we monitored, continuously for 24 h, the dynamic variations of the concentrations of each metal ion in four standardized bacterial species (ATCC 35218, 25922, 25923, 29213). Our analytical results revealed that MD sampling combined with ICP-MS detection had the ability to accurately and continuously monitor the levels of trace metal ions in microbial inoculated culture broths, potentially benefiting research into the bioavailability and detoxification processes of trace metal ions in microbial samples.
- 3 October 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 4 (93) , 51716-51721
Combining microdialysis sampling and inductively coupled plasma mass spectrometry for dynamic monitoring of trace metal ions during bacterial growth periods
Monitoring the dynamic variations of trace metal ions allows us to understand their roles in basic cellular functions and also in microbial-mediated detoxification of metal pollutants. The objective of this study was to develop an easily operated, simultaneous, and continuous method for dynamic monitoring of trace metal ions during bacterial growth periods. Here, we used a microdialysis (MD) sampling technique combined with detection through inductively coupled plasma mass spectrometry (ICP-MS) to determine and quantify trace metal ions. After optimization, we used a retrodialysis technique and a no-net-flux method to assess the probe recovery and analytical performance of the proposed system. The mean probe recoveries of cobalt, copper, strontium, cadmium, and lead were 64.4, 92.6, 40.8, 84.2, and 54.7%, respectively, with typical precision values of 0.5–6.2, 1.1–7.7, 2.0–6.3, 2.3–7.8, and 1.5–7.8%, respectively. To further evaluate the practical applicability of using our proposed MD/ICP-MS method, we monitored, continuously for 24 h, the dynamic variations of the concentrations of each metal ion in four standardized bacterial species (ATCC 35218, 25922, 25923, 29213). Our analytical results revealed that MD sampling combined with ICP-MS detection had the ability to accurately and continuously monitor the levels of trace metal ions in microbial inoculated culture broths, potentially benefiting research into the bioavailability and detoxification processes of trace metal ions in microbial samples.