Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nehir Arik has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Making the Case for Organ‐on‐Chip Platforms in Long‐Acting Therapeutics Development

    by Charlie Gowans, Abdulwahhab Khedr, Panagiotis G. Georgiou, Nehir Arik, Ozlem Sen, Steve P. Rannard, Tom O. McDonald, Christos Tapeinos

    Organ‐on‐chip (OoC) technologies and long‐acting therapeutics (LATs) are two rapidly advancing fields that have not yet been meaningfully integrated. This review argues that their convergence represents a significant and timely opportunity. LAT development is constrained by a preclinical toolbox that fails to capture the coupled, tissue‐dependent processes, depot formation, sustained release, interstitial transport, host response, and local clearance that govern long‐acting performance in vivo. OoC platforms can reproduce the physiological microenvironments in which these processes unfold, including barrier structure, controlled perfusion, mechanical cues, and multicellular organization, under reproducible in vitro conditions. This review first maps the scientific and translational challenges of LAT development and the mechanistic requirements any preclinical platform must address. It then shows how the core design principles of OoC technology enable tissue‐mimicking platforms that reproduce the microenvironments of the main LAT administration routes. Finally, it brings the two fields together, mapping each LAT requirement directly onto a specific OoC capability, showing that the challenges of scale and long‐term culture stability are tractable through defined mitigation strategies, and setting out how the standardization and regulatory alignment now underway can position OoC platforms as credible decision‐support tools that complement, rather than replace, existing in vitro release models.

  • Development of Artemisia absinthium ‐Enriched β‐Glucan Nanoparticle‐Based Nanofibers: Physicochemical Characterization and In Vitro Bioactivity

    by Nehir Arik, Baris Cagri Tosun, Sibel Kaymak, Nilufer Vural, Morteza Servatan, Fatma Zeynep Bozkurt, Pelin Mutlu, Aysen Tezcaner, Demet Cansaran‐Duman, Huseyin Avni Oktem

    Persistent and hard to heal wounds require dressings that do more than cover the injured site; they must also support cell contact and enable local presentation of bioactive compounds. In this study, electrospun polycaprolactone (PCL) mats incorporating Artemisia absinthium (AA) associated β‐glucan nanoparticles were developed as a wound relevant material system. The formulation was evaluated in terms of nanoparticle size, fiber morphology, surface wettability, chemical signatures, and comparative phytochemical profiling. Dynamic light scattering showed that filtered β‐glucan nanoparticles had an average diameter of about 40 nm, while scanning electron microscopy confirmed bead free fiber formation in pristine PCL and PCL/NP fibers. Water contact angle decreased from 143.6° for neat PCL to 71.5° for PCL/NP/AA, indicating a marked increase in wettability. FTIR analysis supported the presence of β‐glucan and extract associated chemical signatures in the fiber system. HPLC based comparative profiling further showed that several major AA phytochemical markers remained detectable after nanoparticle preparation and fiber fabrication, although encapsulation efficiency and time dependent release kinetics were not determined. In preliminary biological assessment, hemolysis decreased from 10.8% to 2.5% under the tested conditions; scratch assay findings showed improved cell migration in the PCL/NP/AA group relative to comparator groups; and nonstandard short contact antibacterial testing showed strain dependent reductions in relative bacterial viability. In silico analysis provided exploratory support for interactions between selected AA associated phytochemicals and wound related inflammatory targets. Taken together, these findings support the potential of the composite as a wound relevant electrospun material with improved wettability, detectable extract associated phytochemical signatures, and preliminary biological readouts relevant to wound related applications.

  • Comparative Evaluation of Antibacterial Effects of Zeolite Composite Powder and Protamine Sulfate on Escherichia coli, Bacillus subtilis, and B. subtilis Endospores

    by Barış Çağrı Tosun, Evrim Elçin, Nehir Arık, Hüseyin Avni Öktem

    Bacterial contamination in the environment poses a significant threat to human health. Herein, we investigated the antibacterial properties of zeolite composite powder containing silver, titanium and zinc ions, designed for potential use in environmental bacterial decontamination. Non-pathogenic Escherichia coli, Bacillus subtilis, B. subtilis endospores and an ampicillin-resistant fluorescent E. coli strain were employed as test organisms. Considering that combinations of antimicrobial agents can exhibit synergistic effects, zeolite composite powder was also tested in combination with the antimicrobial peptide protamine sulfate. Results showed that 500 mg of zeolite composite with a contact time of 15 minutes was required to inhibit E. coli growth, whereas B. subtilis growth was completely inhibited at a much lower dose (50 mg). Germinated B. subtilis endospores were effectively inhibited by combining 90 mg zeolite composite with 1 mg mL-1 protamine. Furthermore, zeolite composite significantly reduced the colony count of ampicillin-resistant fluorescent E. coli in liquid culture after 5 hours of treatment, achieving greater inhibition than protamine alone, which reduced colonies by 85%. When applied to alginate bead–immobilized fluorescent E. coli, zeolite also proved more effective than protamine in decreasing bacterial viability. Overall, this study highlights not only the strong antibacterial potential of zeolite composites but also underscores the importance of optimizing contact time for rapid and efficient bacterial decontamination in environmental applications.

  • Green Innovations

    by Nehir Arik

    Metal nanoparticles (MNPs) have the potential to be employed in both therapeutic and diagnostic applications. Despite the plethora of techniques employed for the formulation of MNPs, it is evident that there is an urgent need to develop a non-toxic, environmentally friendly MNP formulation technology, namely plant-derived MNPs. This section reviews the formulation techniques of plant-derived MNPs, their application areas and a summary of the studies in the literature. First, comprehensive details on plant-derived MNP formulation techniques are provided. Then, literature review is made on the formulation and application areas of different plant-derived MNPs, and overview of the studies is provided. The following sections of this article examine the environmental impact, sustainability and industrial applicability potential of plant-derived MNPs in more detail, while also addressing the limitations of these techniques. Plant-derived MNPs have been a subject of significant interest among researchers and continues to be an endless potential area of research with ongoing studies.

  • Biosensing of arsenic by whole-cell bacterial bioreporter immobilized on polycaprolactone (PCL) electrospun fiber

    by Nehir Arik, Evrim Elcin, Aysen Tezcaner, Huseyin A. Oktem

    In recent years, heavy metals derived from several anthropogenic sources have both direct and indirect detrimental effects on the health of the environment and living organisms. Whole-cell bioreporters (WCBs) that can be used to monitor the levels of heavy metals in drinking and natural spring waters are important. In this study, whole-cell arsenic bacterial bioreporters were immobilized using polycaprolactone (PCL) electrospun fibers as the support material. The aim is to determine the properties of this immobilized bioreporter system by evaluating its performance in arsenic detection. Within the scope of the study, different growth media and fiber immobilization times were tested to determine the parameters affecting the fluorescent signals emitted by the immobilized bioreporter system in the presence of two dominant forms of arsenic, namely arsenite (As(III)) and arsenate (As(V)). In addition, the sensitivity, selectivity, response time, and shelf-life of the developed bioreporter system were evaluated. As far as the literature is concerned, this is the first study to investigate the potential of using PCL-electrospun fiber-immobilized fluorescent bacterial bioreporter for arsenic detection. This study will open new avenues in environmental arsenic monitoring.


  • Optimization of whole-cell bacterial bioreporter immobilization on electrospun cellulose acetate (CA) and polycaprolactone (PCL) fibers for arsenic detection

    by Nehir Arik, Evrim Elcin, Aysen Tezcaner, Hüseyin Avni Oktem

    Arsenic contamination is a critical global problem, and its widespread environmental detection is becoming a prominent issue. Herein, electrospun fibers of cellulose acetate (CA) and polycaprolactone (PCL) were successfully fabricated and used as the support material for immobilization of arsenic-sensing bacterial bioreporter for the first time. To date, no attempt has been made to immobilize fluorescent whole-cell bioreporter cells on electrospun fibers for arsenic detection. CA and PCL electrospun fibers were fabricated via traditional electrospinning technique and characterized by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and contact angle meter. Following immobilization of the bacterial bioreporter cells, the immobilized bacteria were also characterized by viability assay using AlamarBlue. The effects of growth phase and cell concentration on the fluorescence response of fiber-immobilized arsenic bioreporters to arsenic were also investigated. After immobilization of arsenic bioreporters on 10 wt% PCL fiber, 91% of bacterial cells remained viable, while this value was 55.4% for cells immobilized on 12.5 wt% CA fiber. Bioreporter cells in the exponential growth phase were shown to be more sensitive to arsenic compared to aged cells. While both the electropsun PCL- and CA-immobilized bioreporters successfully detected 50 and 100 µg/L of arsenite (As (III)) concentrations, the PCL-immobilized bioreporter showed better fluorescence performance which should be investigated in future studies. This study helps to fill some gaps in the literature and demonstrates the potential for using electrospun fiber-immobilized arsenic whole-cell bioreporter for arsenic detection in water.


  • Open Access

    Development and Characterizations of Engineered Electrospun Bio-Based Polyurethane Containing Essential Oils

    by Nehir Arik, Nesrin Horzum, Yen Bach Truong

    We report the fabrication of bio-based thermoplastic polyurethane (TPU) fibrous scaffolds containing essential oils (EO). The main goal of this study was to investigate the effects of essential oil type (St. John’s Wort oil (SJWO), lavender oil (LO), and virgin olive oil (OO))/concentration on the electrospinnability of TPU. The effects of applied voltage, flow rate, and end-tip distance on the diameter, morphology, and wettability of the TPU/EO electrospun fibers were investigated. The electrospun TPU/EO scaffolds were characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), contact angle (CA), and Fourier transform infrared spectroscopy (FTIR). The addition of oil resulted in an increase in the fiber diameter, reduction in the surface roughness, and, accordingly, a reduction in the contact angle of the composite fibers. TPU fibers containing SJWO and LO have a more flexible structure compared to the fibers containing OO. This comparative study fills the existing information gap and shows the benefits of the fabrication of essential-oil-incorporated electrospun fiber with morphology and size range with respect to the desired applications, which are mostly wound dressing and food packaging.


  • Open Access

    Kurkumin Yüklü Biyo-Bazlı Elektroeğirme Poliüretan Yapılar

    by Nesrin Horzum Polat, Nehir Arik Kinali

    Polymeric electrospun fibers present well-design scaffolds for wound healing applications. Here, the fabrication of biobased polyurethane (PU) blend fibers containing curcumin (Cur) was reported. Not only polymer concentration but also curcumin concentration affects the morphology, diameter, and contact angle values of the fibers. Morphological investigations revealed that the diameter and hydrophilicity of the PU fibers increased upon addition of curcumin. Effect of process parameters (applied voltage, flow rate, and tip-to-collector distance) on the average diameter and the hydrophilicity of the PU and PU/Cur fibers were examined. Optimum conditions to obtain uniform and bead-free PU/Cur fibers were determined as 12.5 kV, 1 mL/h, and 17 cm. This study demonstrates that the electrospinning process provides a simple way of obtaining bioactive agent loaded fibrous scaffolds, as well as contributing to a better understanding of the effect of process variables in the fabrication of PU/Cur blend fibers for wound healing applications.


  • Nanofibers for fiber-reinforced composites

    by Nesrin Horzum, Nehir Arik, Yen Bach Truong


  • Microemulsion versus emulsion as effective carrier of hydroxytyrosol

    by Maria D. Chatzidaki, Nehir Arik, Julien Monteil, Vassiliki Papadimitriou, Fernando Leal-Calderon, Aristotelis Xenakis