Ryan. G. Fronk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ryan. G. Fronk has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
Douglas S. McGregor
21 shared publicationsSteven L. Bellinger
13 shared publicationsTimothy J. Sobering
Electronics Design Laboratory, Kansas State University, Manhattan, KS, USA
12 shared publicationsLuke C. Henson
9 shared publicationsJ. Kenneth Shultis
Semiconductor Materials and Radiological Technologies Laboratory, Kansas State University, Manhattan, KS, USA
8 shared publicationsNathaniel S. Edwards
7 shared publications
Latest Publications
- 1 May 2021
- Published by Office of Scientific and Technical Information (OSTI)
Automated Internal Energy Calibration by OnTheFly for AGR-5/6/7
The software program, OnTheFly, was developed at Idaho National Laboratory (INL) to keep high-purity germanium (HPGe) detectors energy calibrated during very long experiments. Over time, spectra produced from a HPGe detector will slowly stretch or contract, causing the energy calibration to change. If the energy calibration changes too much, it will cause energy lines to be misidentified. The higher the energy line the more affected they are by this change. OnTheFly tracks and adjusts the slowly changing energy calibrations so the energy lines will not be misidentified. OnTheFly was used with the Fission Product Monitoring System (FPMS) during the AGR-5/6/7 irradiation experiment performed at INL’s Advanced Test Reactor (ATR). Five HPGe detectors were used to monitor the five capsules in AGR-5/6/7. There were also two extra HPGe detectors that were maintained as spares. Before each ATR cycle of the experiment, the HPGe detectors were energy calibrated with a thorium radioactive source. During each ATR cycle, each detector would acquire data for 8 hours and then reset and acquire data for another 8 hours. After each 8-hour run, the spectra would be saved and analyzed autonomously. The results were then read by OnTheFly and used to produce a new energy calibrationmore » for each detector. The new energy calibrations were compared to the current energy calibrations and, if certain criteria were met, the new energy calibration would replace the current energy calibration. The new energy calibration would be used for future spectra. OnTheFly was run at least every couple of days but could be run as much as after each 8-hour run. OnTheFly kept the spectra energy calibrated during the ATR cycles over the 2 years and 5 months that the AGR-5/6/7 experiment ran. « less
- 1 May 2021
- Published by Office of Scientific and Technical Information (OSTI)
Automated Internal Energy Calibration by OnTheFly for AGR-5/6/7
The software program, OnTheFly, was developed at Idaho National Laboratory (INL) to keep high-purity germanium (HPGe) detectors energy calibrated during very long experiments. Over time, spectra produced from a HPGe detector will slowly stretch or contract, causing the energy calibration to change. If the energy calibration changes too much, it will cause energy lines to be misidentified. The higher the energy line the more affected they are by this change. OnTheFly tracks and adjusts the slowly changing energy calibrations so the energy lines will not be misidentified. OnTheFly was used with the Fission Product Monitoring System (FPMS) during the AGR-5/6/7 irradiation experiment performed at INL’s Advanced Test Reactor (ATR). Five HPGe detectors were used to monitor the five capsules in AGR-5/6/7. There were also two extra HPGe detectors that were maintained as spares. Before each ATR cycle of the experiment, the HPGe detectors were energy calibrated with a thorium radioactive source. During each ATR cycle, each detector would acquire data for 8 hours and then reset and acquire data for another 8 hours. After each 8-hour run, the spectra would be saved and analyzed autonomously. The results were then read by OnTheFly and used to produce a new energy calibrationmore » for each detector. The new energy calibrations were compared to the current energy calibrations and, if certain criteria were met, the new energy calibration would replace the current energy calibration. The new energy calibration would be used for future spectra. OnTheFly was run at least every couple of days but could be run as much as after each 8-hour run. OnTheFly kept the spectra energy calibrated during the ATR cycles over the 2 years and 5 months that the AGR-5/6/7 experiment ran. « less
- 1 August 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 898, 85-89
Neutron sensitivity of 10B4C-coated aluminum honeycomb using a single-anode wire, P-10 continuous-gas-flow proportional counter
- 1 August 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 898, 85-89
Neutron sensitivity of 10B4C-coated aluminum honeycomb using a single-anode wire, P-10 continuous-gas-flow proportional counter
- 1 June 2018
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 147, 70-76
Neutron sensitivity of 6Li-based suspended foil microstrip neutron detectors using Schott Borofloat® 33 microstrip electrodes
- 1 June 2018
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 147, 70-76
Neutron sensitivity of 6Li-based suspended foil microstrip neutron detectors using Schott Borofloat® 33 microstrip electrodes
- 17 August 2017
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 110, 995-1001
Fabrication and testing of a 5-node micro-pocket fission detector array for real-time, spatial, iron-wire port neutron-flux monitoring
- 17 August 2017
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 110, 995-1001
Fabrication and testing of a 5-node micro-pocket fission detector array for real-time, spatial, iron-wire port neutron-flux monitoring
- 16 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 64 (7) , 1846-1850
Present Status of the Microstructured Semiconductor Neutron Detector-Based Direct Helium-3 Replacement
A small form-factor, third-generation microstructured semiconductor neutron detector (MSND)-based 3 He replacement (HeRep Mk III) detector has been developed to serve as a direct replacement to expensive small-diameter, high-pressure 3 He gas-filled proportional neutron counters. Previously, the larger, 2-in diameter by 6-in-long HeRep Mk II utilized thirty 4-cm 2 active area single-sided MSNDs to replace a similarly sized 4-atm 3 He counter. The net count rate of the HeRep Mk II was 95.15% ± 9.04% of the net count rate of a similarly sized 4-atm 3 He detector for bare 252 Cf at a distance of 1 m. The HeRep Mk II net count rate measured 102.71% ±2.65% of the 3 He detector net count rate when each were placed in 6-in diameter by 9-in-long cylindrical high-density polyethylene (HDPE) moderator casks. The HeRep Mk III was developed as a test bed for new-generation dual-sided MSNDs (DSMSNDs), as well as for reduced-power electronics. The 0.75-in diameter by 4.50-in-long HeRep Mk III was populated with twelve 1-cm 2 active area DSMSNDs. The pvp-type diodes have thus far realized 53.54% ± 0.61% intrinsic thermal-neutron detection efficiency. The HeRep Mk III was tested against a 0.75-in diameter by 3.0-in-long 10-atm 3 He detector with a 30-ng 252 Cf source at a distance of 0.25 m. The HeRep Mk III reported 45.4% ± 0.3% and 56.7% ± 0.2% of the count rate of the 10-atm 3 He detector for detectors with no exterior moderator and in a 3-in by 5.75-in cylindrical HDPE moderator cask, respectively. The HeRep Mk III gamma-ray sensitivity was measured at a dose rate of 50 mR/hr from 137 Cs resulting in a net count rate of 0.01 cps, which corresponds to a gamma-ray rejection ratio of approximately 5:10 7 .
- 16 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 64 (7) , 1846-1850
Present Status of the Microstructured Semiconductor Neutron Detector-Based Direct Helium-3 Replacement
A small form-factor, third-generation microstructured semiconductor neutron detector (MSND)-based 3 He replacement (HeRep Mk III) detector has been developed to serve as a direct replacement to expensive small-diameter, high-pressure 3 He gas-filled proportional neutron counters. Previously, the larger, 2-in diameter by 6-in-long HeRep Mk II utilized thirty 4-cm 2 active area single-sided MSNDs to replace a similarly sized 4-atm 3 He counter. The net count rate of the HeRep Mk II was 95.15% ± 9.04% of the net count rate of a similarly sized 4-atm 3 He detector for bare 252 Cf at a distance of 1 m. The HeRep Mk II net count rate measured 102.71% ±2.65% of the 3 He detector net count rate when each were placed in 6-in diameter by 9-in-long cylindrical high-density polyethylene (HDPE) moderator casks. The HeRep Mk III was developed as a test bed for new-generation dual-sided MSNDs (DSMSNDs), as well as for reduced-power electronics. The 0.75-in diameter by 4.50-in-long HeRep Mk III was populated with twelve 1-cm 2 active area DSMSNDs. The pvp-type diodes have thus far realized 53.54% ± 0.61% intrinsic thermal-neutron detection efficiency. The HeRep Mk III was tested against a 0.75-in diameter by 3.0-in-long 10-atm 3 He detector with a 30-ng 252 Cf source at a distance of 0.25 m. The HeRep Mk III reported 45.4% ± 0.3% and 56.7% ± 0.2% of the count rate of the 10-atm 3 He detector for detectors with no exterior moderator and in a 3-in by 5.75-in cylindrical HDPE moderator cask, respectively. The HeRep Mk III gamma-ray sensitivity was measured at a dose rate of 50 mR/hr from 137 Cs resulting in a net count rate of 0.01 cps, which corresponds to a gamma-ray rejection ratio of approximately 5:10 7 .
- 1 January 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 130, 186-195
Monte Carlo simulation of random, porous (foam) structures for neutron detection
- 1 January 2017
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 130, 186-195
Monte Carlo simulation of random, porous (foam) structures for neutron detection
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Improved low power, modular thermal neutron counter based on microstructured semiconductor neutron detectors (MSND)
A modular, mass-producible, low-power, compact thermal-neutron counter has been developed to meet the needs for modern detector instruments and to compete with aging 3 He-based counter systems. The Domino™ V5.4 neutron detector package is populated with four 1-cm 2 active-area microstructured semiconductor neutron detectors (MSNDs). The detectors are calibrated to an intrinsic thermal neutron detection efficiency of 30% over its 4 cm 2 active area. A gamma-ray rejection ratio of at least 1:10” 8 is achieved at this calibration level. Total device dimensions measure 2.5-cm wide by 3.8-cm tall and 0.47-cm thick, weighing 9.5 g. Individual Dominoes™ can be tiled together into strings and then arrayed laterally to form large-area instruments. In this form, the small sensor can populate instruments up to 1 m 2 , with a cost that is comparable to a similar 3 He-based array. The addition of I 2 C-based bias and threshold controllers reduces sensor cost and complexity over the previously-reported Domino™ versions (V3.0 and V4.0) and allows for user-end calibrations and modifications. Furthermore, the Domino™ has realized 10× reduced power consumption over previous versions, to nearly 90μW at 3.3 volts, while also reducing sensitivity to thermal- and capacitance-induced noise from the MSNDs, making the Domino™ an ideal candidate for 3 He replacement and implementation in low-power, portable neutron-detector instruments.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Improved low power, modular thermal neutron counter based on microstructured semiconductor neutron detectors (MSND)
A modular, mass-producible, low-power, compact thermal-neutron counter has been developed to meet the needs for modern detector instruments and to compete with aging 3 He-based counter systems. The Domino™ V5.4 neutron detector package is populated with four 1-cm 2 active-area microstructured semiconductor neutron detectors (MSNDs). The detectors are calibrated to an intrinsic thermal neutron detection efficiency of 30% over its 4 cm 2 active area. A gamma-ray rejection ratio of at least 1:10” 8 is achieved at this calibration level. Total device dimensions measure 2.5-cm wide by 3.8-cm tall and 0.47-cm thick, weighing 9.5 g. Individual Dominoes™ can be tiled together into strings and then arrayed laterally to form large-area instruments. In this form, the small sensor can populate instruments up to 1 m 2 , with a cost that is comparable to a similar 3 He-based array. The addition of I 2 C-based bias and threshold controllers reduces sensor cost and complexity over the previously-reported Domino™ versions (V3.0 and V4.0) and allows for user-end calibrations and modifications. Furthermore, the Domino™ has realized 10× reduced power consumption over previous versions, to nearly 90μW at 3.3 volts, while also reducing sensitivity to thermal- and capacitance-induced noise from the MSNDs, making the Domino™ an ideal candidate for 3 He replacement and implementation in low-power, portable neutron-detector instruments.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Fourth-generation microstructured semiconductor neutron detector (MSND)-based3He replacement (HeRep) for high pressure3He detectors
Two fourth-generation 3 He replacement (HeRep Mk IV) detectors based on microstructured semiconductor neutron detector (MSND) technology have been fabricated and characterized against a 0.75-in diameter by 3.0-in long, 10-atm 3 He neutron proportional counter. The HeRep Mk IV detectors have a 0.75-in by 0.75-in square form factor with one HeRep Mk IV measuring 3.1-in long and the other measuring 6.1-in long. Each HeRep Mk IV was populated with 15 DS-MSNDs that have an intrinsic thermal-neutron detection efficiency of approximately 50%. The void spaces between adjacent detectors in the 6.1-in long HeRep Mk IV were filled with HDPE moderator. The 3.1-in long HeRep Mk IV recorded 92.8 ± 1.8% of the count rate of the 10-atm 3 He detector for bare 26.5-ng 252 Cf, bare detector and 82.2 ± 0.9% for moderated 252 Cf source, moderated detector configurations. The 6.1-in long HeRep Mk IV count rate was 108.5 ± 2.0% and 113.8 ± 1.2% of the count rate of the 10-atm 3 He detector for bare 252 Cf, bare detector and moderated 252 Cf, moderated detector, respectively. The gamma-ray rejection ratio was determined for 137 Cs at a dose rate of 50 mR/hr. The gamma-ray rejection ratio was 1:1.5×10 8 and 1:4.6×10 8 for the 3.1-in long and 6.1-in long HeRep Mk IV, respectively. The HeRep Mk IVs exhibit a 116% (3.1-in long) and 33% (6.1-in long) improvement in intrinsic detection efficiency over the 0.75-in diameter by 4.5-in long HeRep Mk III for moderated 252 Cf at 25 cm.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Fourth-generation microstructured semiconductor neutron detector (MSND)-based3He replacement (HeRep) for high pressure3He detectors
Two fourth-generation 3 He replacement (HeRep Mk IV) detectors based on microstructured semiconductor neutron detector (MSND) technology have been fabricated and characterized against a 0.75-in diameter by 3.0-in long, 10-atm 3 He neutron proportional counter. The HeRep Mk IV detectors have a 0.75-in by 0.75-in square form factor with one HeRep Mk IV measuring 3.1-in long and the other measuring 6.1-in long. Each HeRep Mk IV was populated with 15 DS-MSNDs that have an intrinsic thermal-neutron detection efficiency of approximately 50%. The void spaces between adjacent detectors in the 6.1-in long HeRep Mk IV were filled with HDPE moderator. The 3.1-in long HeRep Mk IV recorded 92.8 ± 1.8% of the count rate of the 10-atm 3 He detector for bare 26.5-ng 252 Cf, bare detector and 82.2 ± 0.9% for moderated 252 Cf source, moderated detector configurations. The 6.1-in long HeRep Mk IV count rate was 108.5 ± 2.0% and 113.8 ± 1.2% of the count rate of the 10-atm 3 He detector for bare 252 Cf, bare detector and moderated 252 Cf, moderated detector, respectively. The gamma-ray rejection ratio was determined for 137 Cs at a dose rate of 50 mR/hr. The gamma-ray rejection ratio was 1:1.5×10 8 and 1:4.6×10 8 for the 3.1-in long and 6.1-in long HeRep Mk IV, respectively. The HeRep Mk IVs exhibit a 116% (3.1-in long) and 33% (6.1-in long) improvement in intrinsic detection efficiency over the 0.75-in diameter by 4.5-in long HeRep Mk III for moderated 252 Cf at 25 cm.