Zuzana Orságová Králová
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zuzana Orságová Králová has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Radka Gorejová
Department of Physical Chemistry, Faculty of Science, Pavol Jozef Šafárik University in Košice, Moyzesova 11, 041 54 Košice, Slovakia
7 shared publications - Renáta Oriňáková
Department of Physical Chemistry, P. J. Šafárik University in Košice, Moyzesova 11, 041 01 Košice, Slovakia
7 shared publications - Matej Baláž
Institute of Geotechnics, Slovak Academy of Sciences, Watsonova 45, 04001 Košice, Slovakia
5 shared publications Andrej Oriňak
4 shared publications- Andrej Oriňak
P.J. Safarik University
4 shared publications Miriam Kupková
4 shared publications
Latest Publications
- Open Access
- 15 March 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (6) , 2611
Additive Manufacturing of Porous Ti6Al4V Alloy: Geometry Analysis and Mechanical Properties Testing
This work is devoted to the research of porous titanium alloy structures suitable for use in biomedical applications. Mechanical properties were examined on six series of samples with different structures and porosity via static compressive test to identify the type of structure suitable for elimination of the “stress shielding” effect. In addition, high porosity is desirable due to the overgrowth of bone tissue into the internal structure of the implant. The samples were made of titanium alloy Ti6Al4V by using selective laser melting (SLM) additive manufacturing. The series of samples differ from each other in pore size (200, 400, and 600 µm) and porous structure topology (cubic or trabecular). The actual weight of all samples, which plays an important role in identifying other characteristics, was determined. Compressive tests were focused on the detection of maximum stress. The highest porosity and thus the lowest weight were achieved in the samples with a trabecular structure and 600 µm pore size. All tested samples reached optimal values of maximum stress and tensile strength. The most appropriate mechanical properties were observed for samples with a 200 µm pore diameter and cubic structure.
- 15 March 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (6) , 2611
Open AccessAdditive Manufacturing of Porous Ti6Al4V Alloy: Geometry Analysis and Mechanical Properties Testing
This work is devoted to the research of porous titanium alloy structures suitable for use in biomedical applications. Mechanical properties were examined on six series of samples with different structures and porosity via static compressive test to identify the type of structure suitable for elimination of the “stress shielding” effect. In addition, high porosity is desirable due to the overgrowth of bone tissue into the internal structure of the implant. The samples were made of titanium alloy Ti6Al4V by using selective laser melting (SLM) additive manufacturing. The series of samples differ from each other in pore size (200, 400, and 600 µm) and porous structure topology (cubic or trabecular). The actual weight of all samples, which plays an important role in identifying other characteristics, was determined. Compressive tests were focused on the detection of maximum stress. The highest porosity and thus the lowest weight were achieved in the samples with a trabecular structure and 600 µm pore size. All tested samples reached optimal values of maximum stress and tensile strength. The most appropriate mechanical properties were observed for samples with a 200 µm pore diameter and cubic structure.
- Open Access
Degradation Performance of Open-Cell Biomaterials from Phosphated Carbonyl Iron Powder with PEG Coating
Advances in biomedicine and development of modern technologies in the last century have fostered the improvement in human longevity and well-being. This progress simultaneously initiated the need for novel biomaterials. Recently, degradable metallic biomaterials have attracted serious attention in scientific and clinical research owing to their utilization in some specific applications. This work investigates the effect of the polyethylene glycol (PEG) coating of open-cell iron and phosphorus/iron foams on their microstructure and corrosion properties. The addition of phosphorus causes a slight increase in pore size and the deposition of a polymer coating results in a smoothened surface and a moderate decrease in pore diameter. The PEG coating leads to an increase in corrosion rates in both foams and potentially a more desirable product.
Open AccessDegradation Performance of Open-Cell Biomaterials from Phosphated Carbonyl Iron Powder with PEG Coating
Advances in biomedicine and development of modern technologies in the last century have fostered the improvement in human longevity and well-being. This progress simultaneously initiated the need for novel biomaterials. Recently, degradable metallic biomaterials have attracted serious attention in scientific and clinical research owing to their utilization in some specific applications. This work investigates the effect of the polyethylene glycol (PEG) coating of open-cell iron and phosphorus/iron foams on their microstructure and corrosion properties. The addition of phosphorus causes a slight increase in pore size and the deposition of a polymer coating results in a smoothened surface and a moderate decrease in pore diameter. The PEG coating leads to an increase in corrosion rates in both foams and potentially a more desirable product.
- Open Access
Surface Modifications of Biodegradable Metallic Foams for Medical Applications
Significant progress was achieved presently in the development of metallic foam-like materials improved by biocompatible coatings. Material properties of the iron, magnesium, zinc, and their alloys are promising for their uses in medical applications, especially for orthopedic and bone tissue purposes. Current processing technologies and a variety of modifications of the surface and composition facilitate the design of adjusted medical devices with desirable mechanical, morphological, and functional properties. This article reviews the recent progress in the design of advanced degradable metallic biomaterials perfected by different coatings: polymer, inorganic ceramic, and metallic. Appropriate coating of metallic foams could improve the biocompatibility, osteogenesis, and bone tissue-bonding properties. In this paper, a comprehensive review of different coating types used for the enhancement of one or several properties of biodegradable porous implants is given. An outline of the conventional preparation methods of metallic foams and a brief overview of different alloys for medical applications are also provided. In addition, current challenges and future research directions of processing and surface modifications of biodegradable metallic foams for medical applications are suggested.
Open AccessSurface Modifications of Biodegradable Metallic Foams for Medical Applications
Significant progress was achieved presently in the development of metallic foam-like materials improved by biocompatible coatings. Material properties of the iron, magnesium, zinc, and their alloys are promising for their uses in medical applications, especially for orthopedic and bone tissue purposes. Current processing technologies and a variety of modifications of the surface and composition facilitate the design of adjusted medical devices with desirable mechanical, morphological, and functional properties. This article reviews the recent progress in the design of advanced degradable metallic biomaterials perfected by different coatings: polymer, inorganic ceramic, and metallic. Appropriate coating of metallic foams could improve the biocompatibility, osteogenesis, and bone tissue-bonding properties. In this paper, a comprehensive review of different coating types used for the enhancement of one or several properties of biodegradable porous implants is given. An outline of the conventional preparation methods of metallic foams and a brief overview of different alloys for medical applications are also provided. In addition, current challenges and future research directions of processing and surface modifications of biodegradable metallic foams for medical applications are suggested.
- 1 April 2020
- Published by Elsevier in Applied Surface Science
- Vol. 509
Influence of albumin interaction on corrosion resistance of sintered iron biomaterials with polyethyleneimine coating
- 1 April 2020
- Published by Elsevier in Applied Surface Science
- Vol. 509
Influence of albumin interaction on corrosion resistance of sintered iron biomaterials with polyethyleneimine coating
- Open Access
- 1 March 2020
- Published by Walter de Gruyter GmbH in Koroze a ochrana materialu
- Vol. 64 (1) , 1-10
Mechanical and corrosion properties of iron-mangan materials sintered in the presence of plasma
The current trend in development of new metallic materials for certain types of implants is turning away from permanent, biologically inert materials to the use of biodegradable materials. Fe–Mn alloys represent high perspective material for development of new generation of temporary and biodegradable implants. The aim of this work was to study mechanical and corrosion characteristics of powder samples containing 25, 30 and 35 wt % of Mn which are fabricated by pressing, sintering, and additional spark plasma sintering. The influence of preparation method (pressing and sintering) to microstructure, phased composition and corrosion behavior of prepared alloys was studied.
- 1 March 2020
- Published by Walter de Gruyter GmbH in Koroze a ochrana materialu
- Vol. 64 (1) , 1-10
Open AccessMechanical and corrosion properties of iron-mangan materials sintered in the presence of plasma
The current trend in development of new metallic materials for certain types of implants is turning away from permanent, biologically inert materials to the use of biodegradable materials. Fe–Mn alloys represent high perspective material for development of new generation of temporary and biodegradable implants. The aim of this work was to study mechanical and corrosion characteristics of powder samples containing 25, 30 and 35 wt % of Mn which are fabricated by pressing, sintering, and additional spark plasma sintering. The influence of preparation method (pressing and sintering) to microstructure, phased composition and corrosion behavior of prepared alloys was studied.
- 1 March 2020
- Published by Elsevier in Applied Surface Science
- Vol. 505
Evaluation of mechanical properties and hemocompatibility of open cell iron foams with polyethylene glycol coating
- 1 March 2020
- Published by Elsevier in Applied Surface Science
- Vol. 505
Evaluation of mechanical properties and hemocompatibility of open cell iron foams with polyethylene glycol coating
- Open Access
In Vitro Corrosion Behavior of Biodegradable Iron Foams with Polymeric Coating
Research in the field of biodegradable metallic scaffolds has advanced during the last decades. Resorbable implants based on iron have become an attractive alternative to the temporary devices made of inert metals. Overcoming an insufficient corrosion rate of pure iron, though, still remains a problem. In our work, we have prepared iron foams and coated them with three different concentrations of polyethyleneimine (PEI) to increase their corrosion rates. Scanning electron microscopy (SEM) coupled with energy dispersive X-ray analysis (EDX), Fourier-transform infrared spectroscopy (FT-IR), and Raman spectroscopy were used for characterization of the polymer coating. The corrosion behavior of the powder-metallurgically prepared samples was evaluated electrochemically using an anodic polarization method. A 12 weeks long in vitro degradation study in Hanks’ solution at 37 °C was also performed. Surface morphology, corrosion behavior, and degradation rates of the open-cell foams were studied and discussed. The use of PEI coating led to an increase in the corrosion rates of the cellular material. The sample with the highest concentration of PEI film showed the most rapid corrosion in the environment of simulated body fluids.
Open AccessIn Vitro Corrosion Behavior of Biodegradable Iron Foams with Polymeric Coating
Research in the field of biodegradable metallic scaffolds has advanced during the last decades. Resorbable implants based on iron have become an attractive alternative to the temporary devices made of inert metals. Overcoming an insufficient corrosion rate of pure iron, though, still remains a problem. In our work, we have prepared iron foams and coated them with three different concentrations of polyethyleneimine (PEI) to increase their corrosion rates. Scanning electron microscopy (SEM) coupled with energy dispersive X-ray analysis (EDX), Fourier-transform infrared spectroscopy (FT-IR), and Raman spectroscopy were used for characterization of the polymer coating. The corrosion behavior of the powder-metallurgically prepared samples was evaluated electrochemically using an anodic polarization method. A 12 weeks long in vitro degradation study in Hanks’ solution at 37 °C was also performed. Surface morphology, corrosion behavior, and degradation rates of the open-cell foams were studied and discussed. The use of PEI coating led to an increase in the corrosion rates of the cellular material. The sample with the highest concentration of PEI film showed the most rapid corrosion in the environment of simulated body fluids.
- Open Access
- 6 July 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (07) , 1-11
Electrochemically deposited silver detection substrate for surface-enhanced Raman spectroscopy cancer diagnostics
The Journal of Biomedical Optics (JBO) publishes peer-reviewed papers on the use of novel optical systems and techniques for improved health care and biomedical research.
- 6 July 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (07) , 1-11
Open AccessElectrochemically deposited silver detection substrate for surface-enhanced Raman spectroscopy cancer diagnostics
The Journal of Biomedical Optics (JBO) publishes peer-reviewed papers on the use of novel optical systems and techniques for improved health care and biomedical research.
- Open Access
An In Vitro Corrosion Study of Open Cell Iron Structures with PEG Coating for Bone Replacement Applications
Iron-based substrates with polyethylene glycol coating were prepared as possible materials for biodegradable orthopedic implants. Biodegradable materials that provide mechanical support of the diseased tissue at the time of implanting and then disappear gradually during the healing process are sometimes favored instead of permanent implants. The implant degradation rate should match the time of the tissue regrowth. In this work, the degradation behavior of iron-based foams was studied electrochemically during immersion tests in Hanks’ solution. The corrosion rate of the polyethylene glycol-coated samples increased and the corrosion potential shifted to more negative values. This indicates an enhanced degradation rate as compared to the uncoated material, fulfilling the goal of being able to tune the degradation rate. It is the interfacial interaction between the hydrophilic polymer layer and the iron surface that is responsible for the enhanced oxidation rate of iron.
Open AccessAn In Vitro Corrosion Study of Open Cell Iron Structures with PEG Coating for Bone Replacement Applications
Iron-based substrates with polyethylene glycol coating were prepared as possible materials for biodegradable orthopedic implants. Biodegradable materials that provide mechanical support of the diseased tissue at the time of implanting and then disappear gradually during the healing process are sometimes favored instead of permanent implants. The implant degradation rate should match the time of the tissue regrowth. In this work, the degradation behavior of iron-based foams was studied electrochemically during immersion tests in Hanks’ solution. The corrosion rate of the polyethylene glycol-coated samples increased and the corrosion potential shifted to more negative values. This indicates an enhanced degradation rate as compared to the uncoated material, fulfilling the goal of being able to tune the degradation rate. It is the interfacial interaction between the hydrophilic polymer layer and the iron surface that is responsible for the enhanced oxidation rate of iron.
- 1 November 2017
- Published by Elsevier in Applied Surface Science
- Vol. 423, 322-330
Colloidal lithography with electrochemical nickel deposition as a unique method for improved silver decorated nanocavities in SERS applications
- 1 November 2017
- Published by Elsevier in Applied Surface Science
- Vol. 423, 322-330
Colloidal lithography with electrochemical nickel deposition as a unique method for improved silver decorated nanocavities in SERS applications