Didem Giray Dilgin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Didem Giray Dilgin has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Yusuf Dilgin
Department of Chemistry, Faculty of Science, Çanakkale Onsekiz Mart University, Çanakkale, Türkiye
11 shared publications Bensu Ertek
Çanakkale Onsekiz Mart University
6 shared publicationsSerkan Karakaya
Department of Chemistry, Faculty of Science, Çanakkale Onsekiz Mart University, Çanakkale, Türkiye
5 shared publicationsBayram Kızılkaya
Çanakkale Onsekiz Mart University, Science and Technology Application and Research Center-Central Laboratory, TR-17100 Çanakkale, Turkey
4 shared publicationsDelia Gligor
Babes-Bolyai University
3 shared publicationsH. İsMet Gökçel
Ege University, Science Faculty, Department of Chemistry, 35100 Bornova-İzmir, Turkey
3 shared publications
Latest Publications
- 30 September 2025
- Published by Akademik Gida in Akademik Gıda
- Vol. 23 (3) , 231-245
A Review on the Simultaneous Electrochemical Determination of Azo Dyes Used as Colorants in Foods and Beverages
Synthetic azo dyes such as sunset yellow, tartrazine, allura red, amaranth, and azorubine have been widely used in foods and beverages as coloring agents. These colorants are frequently preferred in the industry due to their attractive bright colors, low cost, easy availability, and outstanding storage stability against pH and light. In addition to these advantages, synthetic dyes are known to have adverse effects on human health, including carcinogenicity, asthma, allergies, anxiety, and hyperactivity, especially in children. Organizations such as the Joint FAO/WHO Expert Committee on Food Additives (JECFA) and the EU Scientific Committee on Food (SCF) have determined that the acceptable daily intake of these colorants must not exceed 7.5 mg per kg of body weight. Therefore, the quantitative determination of synthetic dyes in foods and beverages is crucial, and their levels must be strictly controlled in foods. Because these azo dyes are electroactive, numerous studies have been conducted recently on their single or simultaneous electrochemical determination, and review articles have generally been published on the determination of single dyes. This review presents recent electrochemical studies on the highly sensitive and selective simultaneous determination of these colorants using voltammetric methods on various modified electrodes. The study discusses the general properties of azo dyes used as colorants; their electrochemical behavior and oxidation/reduction reaction mechanisms; the electrodes used and their modifications; and finally, their simultaneous voltammetric determination.
- 30 September 2025
- Published by Akademik Gida in Akademik Gıda
- Vol. 23 (3) , 231-245
A Review on the Simultaneous Electrochemical Determination of Azo Dyes Used as Colorants in Foods and Beverages
Synthetic azo dyes such as sunset yellow, tartrazine, allura red, amaranth, and azorubine have been widely used in foods and beverages as coloring agents. These colorants are frequently preferred in the industry due to their attractive bright colors, low cost, easy availability, and outstanding storage stability against pH and light. In addition to these advantages, synthetic dyes are known to have adverse effects on human health, including carcinogenicity, asthma, allergies, anxiety, and hyperactivity, especially in children. Organizations such as the Joint FAO/WHO Expert Committee on Food Additives (JECFA) and the EU Scientific Committee on Food (SCF) have determined that the acceptable daily intake of these colorants must not exceed 7.5 mg per kg of body weight. Therefore, the quantitative determination of synthetic dyes in foods and beverages is crucial, and their levels must be strictly controlled in foods. Because these azo dyes are electroactive, numerous studies have been conducted recently on their single or simultaneous electrochemical determination, and review articles have generally been published on the determination of single dyes. This review presents recent electrochemical studies on the highly sensitive and selective simultaneous determination of these colorants using voltammetric methods on various modified electrodes. The study discusses the general properties of azo dyes used as colorants; their electrochemical behavior and oxidation/reduction reaction mechanisms; the electrodes used and their modifications; and finally, their simultaneous voltammetric determination.
- 26 September 2025
- Published by Celal Bayar University Journal of Science in Celal Bayar Üniversitesi Fen Bilimleri Dergisi
- Vol. 21 (3) , 121-130
Voltammetric Determination of Hydroxychloroquine Used in the Treatment of COVID‐19 at MWCNT Modified Pencil Graphite Electrode
COVID-19, the most significant pandemic of the 21st century, has prompted the use of various drugs to slow down the viral process in patients infected with it. One of these drugs is hydroxychloroquine, and due to its importance and frequent use in the treatment of COVID-19, its rapid, accurate and inexpensive determination in biological or pharmaceutical samples is very important. In this study, the electrochemical behavior of hydroxychloroquine was investigated, and voltammetric determination of hydroxychloroquine was performed with a pencil graphite electrode modified with multi-walled carbon nanotubes. Scanning electron microscopy images were used to examine the surfaces of both the regular pencil graphite electrode and the modified one with multi-walled carbon nanotube. Cyclic voltammetric measurements showed that hydroxychloroquine was irreversibly oxidized at approximately +700 and +900 mV in Britton Robinson buffer solution at pH 10.0. Considering these oxidation peaks, differential pulse voltammetric determination of hydroxychloroquine was carried out under optimized conditions. A linear response was obtained from the multi-walled carbon nanotube-modified pencil graphite electrode in the range of 0.1 to 200 µmolL-1 for peaks at both +700 mV and +900 mV with detection limits of 0.04 and 0.05 µmolL-1, respectively. The method was tested on the real tablet and water samples; nearly 100 % recovery was achieved for hydroxychloroquine spiked into the water sample, while the amount of the labeled compound in the pharmaceutical tablet was accurately determined. This result confirmed that the multi-walled carbon nanotube-modified pencil graphite electrode is very effective for selectively and accurately determining hydroxychloroquine in real samples.
- 26 September 2025
- Published by Celal Bayar University Journal of Science in Celal Bayar Üniversitesi Fen Bilimleri Dergisi
- Vol. 21 (3) , 121-130
Voltammetric Determination of Hydroxychloroquine Used in the Treatment of COVID‐19 at MWCNT Modified Pencil Graphite Electrode
COVID-19, the most significant pandemic of the 21st century, has prompted the use of various drugs to slow down the viral process in patients infected with it. One of these drugs is hydroxychloroquine, and due to its importance and frequent use in the treatment of COVID-19, its rapid, accurate and inexpensive determination in biological or pharmaceutical samples is very important. In this study, the electrochemical behavior of hydroxychloroquine was investigated, and voltammetric determination of hydroxychloroquine was performed with a pencil graphite electrode modified with multi-walled carbon nanotubes. Scanning electron microscopy images were used to examine the surfaces of both the regular pencil graphite electrode and the modified one with multi-walled carbon nanotube. Cyclic voltammetric measurements showed that hydroxychloroquine was irreversibly oxidized at approximately +700 and +900 mV in Britton Robinson buffer solution at pH 10.0. Considering these oxidation peaks, differential pulse voltammetric determination of hydroxychloroquine was carried out under optimized conditions. A linear response was obtained from the multi-walled carbon nanotube-modified pencil graphite electrode in the range of 0.1 to 200 µmolL-1 for peaks at both +700 mV and +900 mV with detection limits of 0.04 and 0.05 µmolL-1, respectively. The method was tested on the real tablet and water samples; nearly 100 % recovery was achieved for hydroxychloroquine spiked into the water sample, while the amount of the labeled compound in the pharmaceutical tablet was accurately determined. This result confirmed that the multi-walled carbon nanotube-modified pencil graphite electrode is very effective for selectively and accurately determining hydroxychloroquine in real samples.
- 17 January 2025
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 29 (7) , 2859-2869
An application of a disposable electrode for the sensitive, selective, and cost-effective voltammetric determination of antiparkinsonism drug entacapone based on both its oxidation and reduction
- 17 January 2025
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 29 (7) , 2859-2869
An application of a disposable electrode for the sensitive, selective, and cost-effective voltammetric determination of antiparkinsonism drug entacapone based on both its oxidation and reduction
- Open Access
- 7 September 2023
- Published by Springer Nature in Research Square
Simple, sensitive, and cost-effective voltammetric determination of salbutamol at a pencil graphite electrode modified with Nafion and functionalized multi-walled carbon nanotubes
This study describes a simple, highly sensitive, and cost-effective electrochemical determination of salbutamol (SBT) at a disposable pencil graphite electrode modified with nafion/functionalized multi-walled carbon nanotubes composite material (Nf/f-MWCNTs/PGE). The electrochemical response of SBT at this modified electrode was investigated by both differential pulse voltammetry (DPV) and cyclic voltammetry (CV) techniques. The voltammetric measurements confirmed that the combination of f-MWCNTs with Nf shows remarkable electrocatalytic activity on the oxidation of SBT due to a synergistic effect of Nf via electrostatic interaction and f-MWCNTs via excellent conductivity and large specific surface area. DPV results show that the composite electrode gives two linear ranges of 0.10–17.5 µM and 17.5–100 µM with a detection limit (LOD) of 0.027 µM SBT. Moreover, the studies of some potential interferants show that there is no significant interference in the determination of SBT. The proposed procedure was successfully applied to determine SBT in tube- and syrup-type pharmaceutical formulations and acceptable results were obtained with high accuracy and precision. Moreover, the proposed sensor displays good intraday and interday precision for the voltammetric determination of SBT..
- 7 September 2023
- Published by Springer Nature in Research Square
Open AccessSimple, sensitive, and cost-effective voltammetric determination of salbutamol at a pencil graphite electrode modified with Nafion and functionalized multi-walled carbon nanotubes
This study describes a simple, highly sensitive, and cost-effective electrochemical determination of salbutamol (SBT) at a disposable pencil graphite electrode modified with nafion/functionalized multi-walled carbon nanotubes composite material (Nf/f-MWCNTs/PGE). The electrochemical response of SBT at this modified electrode was investigated by both differential pulse voltammetry (DPV) and cyclic voltammetry (CV) techniques. The voltammetric measurements confirmed that the combination of f-MWCNTs with Nf shows remarkable electrocatalytic activity on the oxidation of SBT due to a synergistic effect of Nf via electrostatic interaction and f-MWCNTs via excellent conductivity and large specific surface area. DPV results show that the composite electrode gives two linear ranges of 0.10–17.5 µM and 17.5–100 µM with a detection limit (LOD) of 0.027 µM SBT. Moreover, the studies of some potential interferants show that there is no significant interference in the determination of SBT. The proposed procedure was successfully applied to determine SBT in tube- and syrup-type pharmaceutical formulations and acceptable results were obtained with high accuracy and precision. Moreover, the proposed sensor displays good intraday and interday precision for the voltammetric determination of SBT..
- 4 March 2022
- Published by Taylor & Francis in Analytical Letters
- Vol. 55 (13) , 2046-2057
Flow-Injection Amperometric Determination of Glucose Using Nickel Oxide-Cobalt (II,III) Oxide and Nickel Oxide-Copper Nanoparticle Modified Pencil Graphite Electrodes
This study features an enzyme-free amperometric determination of glucose with flow injection analysis (FIA) using pencil graphite electrodes (PGEs) modified with nickel oxide-cobalt (II,III) oxide (NiO-Co3O4/PGE) and nickel oxide-copper nanoparticle (NiO-CuNPs/PGE). Both modified PGEs exhibited excellent electrocatalytic activity toward oxidation of glucose in strong alkaline media since they enhanced the peak current compared with the bare PGE and single metal oxide- or metal nanoparticle-modified PGEs. Flow-injection (FI) amperometry showed the linear response range, the limit of detection and sensitivity for NiO-Co3O4/PGE and NiO-CuNPs/PGE were 1.0–1000 µM, 0.23 µM and 586 µA mM−1 cm−2, and 0.10–250 µM, 0.03 µM and 949 µA mM−1 cm−2, respectively. Glucose was determined in real samples with good accuracy and precision.
- 4 March 2022
- Published by Taylor & Francis in Analytical Letters
- Vol. 55 (13) , 2046-2057
Flow-Injection Amperometric Determination of Glucose Using Nickel Oxide-Cobalt (II,III) Oxide and Nickel Oxide-Copper Nanoparticle Modified Pencil Graphite Electrodes
This study features an enzyme-free amperometric determination of glucose with flow injection analysis (FIA) using pencil graphite electrodes (PGEs) modified with nickel oxide-cobalt (II,III) oxide (NiO-Co3O4/PGE) and nickel oxide-copper nanoparticle (NiO-CuNPs/PGE). Both modified PGEs exhibited excellent electrocatalytic activity toward oxidation of glucose in strong alkaline media since they enhanced the peak current compared with the bare PGE and single metal oxide- or metal nanoparticle-modified PGEs. Flow-injection (FI) amperometry showed the linear response range, the limit of detection and sensitivity for NiO-Co3O4/PGE and NiO-CuNPs/PGE were 1.0–1000 µM, 0.23 µM and 586 µA mM−1 cm−2, and 0.10–250 µM, 0.03 µM and 949 µA mM−1 cm−2, respectively. Glucose was determined in real samples with good accuracy and precision.
- 21 October 2021
- Published by Springer Nature in Monatshefte für Chemie - Chemical Monthly
- Vol. 152 (12) , 1491-1503
Electrocatalytic oxidation and flow injection analysis of formaldehyde at binary metal oxides (Co3O4–NiO and CuO–Co3O4) modified pencil graphite electrodes
- 21 October 2021
- Published by Springer Nature in Monatshefte für Chemie - Chemical Monthly
- Vol. 152 (12) , 1491-1503
Electrocatalytic oxidation and flow injection analysis of formaldehyde at binary metal oxides (Co3O4–NiO and CuO–Co3O4) modified pencil graphite electrodes
- Open Access
- 26 March 2019
- Published by Akademik Gida in Akademik Gıda
- Vol. 17 (1) , 1-8
Voltammetric Determination of Vanillin Using a Pretreated Pencil Graphite Electrode
In this study, a sensitive voltammetric method for the determination of vanillin in commercial food products was proposed using a pencil lead as an electrode material. In the cyclic voltammograms of vanillin recorded in pH 8.0 Britton Robinson buffer at the pre-oxidized pencil graphite electrode (p-PGE), a sharp peak was observed at about 520 mV (vs. Ag / AgCl electrode) attributed to the oxidation of vanillin. Subsequently, the voltammetric determination of vanillin based on its oxidation at p-PGE was carried out using the differential pulse voltammetry (DPV) technique under optimized conditions. DPV results showed that the oxidation peak current of vanillin increased linearly in the concentration range of 0.5 to 10.0 µM vanillin with a detection limit of 0.16 µM (based on 3S b ). In the final step, this voltammetric method was applied to the determination of vanillin in vanilla syrup samples. Results were in good agreement with the values indicated on the labels of samples.
- 26 March 2019
- Published by Akademik Gida in Akademik Gıda
- Vol. 17 (1) , 1-8
Open AccessVoltammetric Determination of Vanillin Using a Pretreated Pencil Graphite Electrode
In this study, a sensitive voltammetric method for the determination of vanillin in commercial food products was proposed using a pencil lead as an electrode material. In the cyclic voltammograms of vanillin recorded in pH 8.0 Britton Robinson buffer at the pre-oxidized pencil graphite electrode (p-PGE), a sharp peak was observed at about 520 mV (vs. Ag / AgCl electrode) attributed to the oxidation of vanillin. Subsequently, the voltammetric determination of vanillin based on its oxidation at p-PGE was carried out using the differential pulse voltammetry (DPV) technique under optimized conditions. DPV results showed that the oxidation peak current of vanillin increased linearly in the concentration range of 0.5 to 10.0 µM vanillin with a detection limit of 0.16 µM (based on 3S b ). In the final step, this voltammetric method was applied to the determination of vanillin in vanilla syrup samples. Results were in good agreement with the values indicated on the labels of samples.
- 6 March 2018
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 15 (6) , 1355-1363
A low-cost, fast, disposable and sensitive biosensor study: flow injection analysis of glucose at poly-methylene blue-modified pencil graphite electrode
- 6 March 2018
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 15 (6) , 1355-1363
A low-cost, fast, disposable and sensitive biosensor study: flow injection analysis of glucose at poly-methylene blue-modified pencil graphite electrode
- 30 October 2017
- Published by Taylor & Francis in Analytical Letters
- Vol. 51 (1-2) , 186-197
Determination of Calcium Dobesilate by Differential Pulse Voltammetry at a Disposable Pencil Graphite Electrode
The electrochemistry of calcium dobesilate was investigated by recording cyclic and differential pulse voltammograms at a disposable and inexpensive pencil graphite electrode (PGE). Cyclic voltammograms of calcium dobesilate recorded in 0.1 M HCl showed a pair of well-defined redox peaks at the PGE indicating excellent electrochemical activity. The oxidation peak current of the calcium dobesilate was used for its determination by recording its differential pulse voltammograms. The anodic peak current increased linearly with the concentration of calcium dobesilate in the range from 0.2 to 100 µM with a detection limit 0.065 µM. Relative standard deviations of 2.0 and 1.1% for innerday and 3.6 and 2.0% for intraday precision were obtained for three successive determinations of 0.5 and 10 µM calcium dobesilate, respectively, which indicates acceptable repeatability and reproducibility. This voltammetric method was also successfully applied to the direct determination of calcium dobesilate in pharmaceutical samples. The effect of various interfering compounds on the calcium dobesilate peak current was studied. Thus, an unmodified PGE provides a new, promising, and alternative method of achieving sensitive, inexpensive, and selective determination of calcium dobesilate.
- 30 October 2017
- Published by Taylor & Francis in Analytical Letters
- Vol. 51 (1-2) , 186-197
Determination of Calcium Dobesilate by Differential Pulse Voltammetry at a Disposable Pencil Graphite Electrode
The electrochemistry of calcium dobesilate was investigated by recording cyclic and differential pulse voltammograms at a disposable and inexpensive pencil graphite electrode (PGE). Cyclic voltammograms of calcium dobesilate recorded in 0.1 M HCl showed a pair of well-defined redox peaks at the PGE indicating excellent electrochemical activity. The oxidation peak current of the calcium dobesilate was used for its determination by recording its differential pulse voltammograms. The anodic peak current increased linearly with the concentration of calcium dobesilate in the range from 0.2 to 100 µM with a detection limit 0.065 µM. Relative standard deviations of 2.0 and 1.1% for innerday and 3.6 and 2.0% for intraday precision were obtained for three successive determinations of 0.5 and 10 µM calcium dobesilate, respectively, which indicates acceptable repeatability and reproducibility. This voltammetric method was also successfully applied to the direct determination of calcium dobesilate in pharmaceutical samples. The effect of various interfering compounds on the calcium dobesilate peak current was studied. Thus, an unmodified PGE provides a new, promising, and alternative method of achieving sensitive, inexpensive, and selective determination of calcium dobesilate.