Sandesh Udupi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sandesh Udupi has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Kiran Asranna1 shared publication
- Kriti Puri
Lady Hardinge Medical College New Delhi India
1 shared publication - Shaji Mathew
Kasturba Medical College, Manipal Academy of Higher Education, Manipal
1 shared publication - Sushma Thimmaiah Kanakalakshmi
Department of Anesthesiology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, 576104
1 shared publication
Latest Publications
- 1 June 2020
- Published by Elsevier in Trends in Anaesthesia and Critical Care
- Vol. 32, 33-38
Hemodynamic response of lignocaine in laryngoscopy and intubation
- 1 June 2020
- Published by Elsevier in Trends in Anaesthesia and Critical Care
- Vol. 32, 33-38
Hemodynamic response of lignocaine in laryngoscopy and intubation
- Open Access
- 1 June 2020
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 73 (3) , 232-238
A novel approach to bedside pretransfusion identity check of blood and its components: the Sandesh Positive-Negative protocol
Mis-transfusion of blood components triggering serious complications are mostly due to preventable clerical errors, especially pre-transfusion misidentification of patient/blood unit at bedside. Recommendations for standard identity check is by electronic devices like barcode scanners. Establishments unable to afford these gadgets (e.g. economically poorer countries) perform identity check subjectively through visual judgement. This is prone to errors precipitating tremendous anxiety in personnel transfusing blood unit. Hence a novel objective method for pre-transfusion identity check-"Sandesh Positive-Negative (SPON) Protocol" was evaluated. A non-randomized study on bedside pre-transfusion identity check in terms of anxiety, satisfaction and errors occurred was conducted. 75 subjects performed transfusion (Consultants, postgraduates and nurses). Intervention was accomplished by matching a custom made negative label arriving with blood component with the positive label of the same patient available at bedside who is about to receive transfusion. 85.3% subjects were anxious about pre-transfusion identity check with existing standard practice. After implementation of SPON protocol, only 38.7% had either mild or severe anxiety (p< 0.05) and none of them were dissatisfied. Overall level of satisfaction also increased with number of subjects being highly satisfied rising to 38.7% from 8.0% (p<0.05). Although only 9.3% were dissatisfied about prevailing practice, about 70.7% felt need for a better/additional protocol. There was no occurrence of clerical error. SPON protocol is a cost effective objective technique for final bedside identity check of blood components which reduces anxiety and increases satisfaction levels.
- 1 June 2020
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 73 (3) , 232-238
Open AccessA novel approach to bedside pretransfusion identity check of blood and its components: the Sandesh Positive-Negative protocol
Mis-transfusion of blood components triggering serious complications are mostly due to preventable clerical errors, especially pre-transfusion misidentification of patient/blood unit at bedside. Recommendations for standard identity check is by electronic devices like barcode scanners. Establishments unable to afford these gadgets (e.g. economically poorer countries) perform identity check subjectively through visual judgement. This is prone to errors precipitating tremendous anxiety in personnel transfusing blood unit. Hence a novel objective method for pre-transfusion identity check-"Sandesh Positive-Negative (SPON) Protocol" was evaluated. A non-randomized study on bedside pre-transfusion identity check in terms of anxiety, satisfaction and errors occurred was conducted. 75 subjects performed transfusion (Consultants, postgraduates and nurses). Intervention was accomplished by matching a custom made negative label arriving with blood component with the positive label of the same patient available at bedside who is about to receive transfusion. 85.3% subjects were anxious about pre-transfusion identity check with existing standard practice. After implementation of SPON protocol, only 38.7% had either mild or severe anxiety (p< 0.05) and none of them were dissatisfied. Overall level of satisfaction also increased with number of subjects being highly satisfied rising to 38.7% from 8.0% (p<0.05). Although only 9.3% were dissatisfied about prevailing practice, about 70.7% felt need for a better/additional protocol. There was no occurrence of clerical error. SPON protocol is a cost effective objective technique for final bedside identity check of blood components which reduces anxiety and increases satisfaction levels.
- Open Access
- 1 January 2020
- Published by Medknow in Indian Journal of Anaesthesia
- Vol. 64 (3) , 250-251
Short and/or long laryngoscope handle—“Sandesh Combihandle”
Indian Journal of Anaesthesia, Official publication of Indian Society of Anaesthesiologists
- 1 January 2020
- Published by Medknow in Indian Journal of Anaesthesia
- Vol. 64 (3) , 250-251
Open AccessShort and/or long laryngoscope handle—“Sandesh Combihandle”
Indian Journal of Anaesthesia, Official publication of Indian Society of Anaesthesiologists
- 23 September 2016
- Published by BMJ in BMJ Innovations
- Vol. 2 (4) , 149-151
Sandesh combihandle: a modification of a standard laryngoscope handle for usage either as a short or a standard long handle
A modification of laryngoscope handle ‘Sandesh combihandle’ is described which can be used either as a short handle or as a standard long handle to overcome the difficulties and problems associated with swapping between the 2 handles during laryngoscopy.
- 23 September 2016
- Published by BMJ in BMJ Innovations
- Vol. 2 (4) , 149-151
Sandesh combihandle: a modification of a standard laryngoscope handle for usage either as a short or a standard long handle
A modification of laryngoscope handle ‘Sandesh combihandle’ is described which can be used either as a short handle or as a standard long handle to overcome the difficulties and problems associated with swapping between the 2 handles during laryngoscopy.