Mert Akgün
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mert Akgün has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Sermet Koyuncu
Department of Chemical Engineering Çanakkale Onsekiz Mart University Çanakkale Türkiye
2 shared publications - Abdollah Omrani
Department of Chemistry, Istanbul Technical University, 34469 Maslak, Istanbul, Turkey
1 shared publication - Ari̇fE Aktaş
Science and Technology Application and Research Center, Çanakkale Onsekiz Mart University, Çanakkale, Turkiye;Department of Chemical Engineering, Faculty of Engineering, Çanakkale Onsekiz Mart University, Çanakkale, Turkiye
1 shared publication - Ayhan Oral
Department of Chemistry, Faculty of Science , Canakkale Onsekiz Mart University , Canakkale 17100 , Türkiye
1 shared publication - Baris Kiskan
Department of Chemistry
1 shared publication - Gürkan Alkan1 shared publication
Latest Publications
- Open Access
- 16 October 2026
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 50 (5) , 503-512
Fabrication of cross-linked thiophene-coumarin-fluorene donor–acceptor pentamer thin films for electrochromic devices application
Functionalized p-conjugated polymers have emerged as promising electrochromic materials due to their well-defined molecular structures, facile synthesis, and ability to form smooth and homogeneous thin films. Furthermore, surface cross-linking enhances the mechanical and environmental stability of these films while improving their durability during electrochemical operation. In this study, a unique band gap-tunable pentamer (FBP) was developed featuring a D-A-D-A-D configuration, which includes thiophene, coumarin, and fluorene. Cross-linked films (FBPX) were obtained using both spray and electrospray methods in the presence of tetrathiol-based crosslinkers and 366 nm light, thanks to the functionalizable allyl groups present in the FBP structure. UV–Vis analysis revealed absorption maxima at 410 nm and 330 nm for FBP and FBPX films, respectively, with corresponding optical band gap (Eg,opt) values of 2.88 and 3.30 eV. Moreover, electrochemical measurements indicated HOMO–LUMO energy levels of eV for FBP and eV for FBPX, demonstrating the influence of cross-linking on the electronic structure of the films. Atomic force microscopy analysis revealed that the electrospray deposition method significantly increased the surface roughness, with RMS values rising from 6.2 nm for the spin-coated film to 84.6 nm for the electrospray-coated film, resulting in a highly textured and porous morphology. Furthermore, electrochromic devices based on FBPX films were fabricated using different coating and surface cross-linking techniques. These results demonstrate that surface cross-linking and coating methodology significantly influence the electrochromic performance, enabling enhanced color modulation, durability, and response characteristics of FBPX-based electrochromic devices.
- 16 October 2026
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 50 (5) , 503-512
Open AccessFabrication of cross-linked thiophene-coumarin-fluorene donor–acceptor pentamer thin films for electrochromic devices application
Functionalized p-conjugated polymers have emerged as promising electrochromic materials due to their well-defined molecular structures, facile synthesis, and ability to form smooth and homogeneous thin films. Furthermore, surface cross-linking enhances the mechanical and environmental stability of these films while improving their durability during electrochemical operation. In this study, a unique band gap-tunable pentamer (FBP) was developed featuring a D-A-D-A-D configuration, which includes thiophene, coumarin, and fluorene. Cross-linked films (FBPX) were obtained using both spray and electrospray methods in the presence of tetrathiol-based crosslinkers and 366 nm light, thanks to the functionalizable allyl groups present in the FBP structure. UV–Vis analysis revealed absorption maxima at 410 nm and 330 nm for FBP and FBPX films, respectively, with corresponding optical band gap (Eg,opt) values of 2.88 and 3.30 eV. Moreover, electrochemical measurements indicated HOMO–LUMO energy levels of eV for FBP and eV for FBPX, demonstrating the influence of cross-linking on the electronic structure of the films. Atomic force microscopy analysis revealed that the electrospray deposition method significantly increased the surface roughness, with RMS values rising from 6.2 nm for the spin-coated film to 84.6 nm for the electrospray-coated film, resulting in a highly textured and porous morphology. Furthermore, electrochromic devices based on FBPX films were fabricated using different coating and surface cross-linking techniques. These results demonstrate that surface cross-linking and coating methodology significantly influence the electrochromic performance, enabling enhanced color modulation, durability, and response characteristics of FBPX-based electrochromic devices.
- 13 January 2026
- Published by Elsevier in Chemical Engineering Journal
- Vol. 529
A fully electrospray-processible electrochromic supercapacitor for smart window applications
- 13 January 2026
- Published by Elsevier in Chemical Engineering Journal
- Vol. 529
A fully electrospray-processible electrochromic supercapacitor for smart window applications
- 6 December 2023
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 6 (1) , 253-264
Catalytic Role of Nanoconfinement inside MIL-125 (Ti) on the Ring-Opening Polymerization of Simple Benzoxazines
- 6 December 2023
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 6 (1) , 253-264
Catalytic Role of Nanoconfinement inside MIL-125 (Ti) on the Ring-Opening Polymerization of Simple Benzoxazines
- Open Access
- 28 April 2023
- Published by Society of Chemists and Technologists of Macedonia in Macedonian Journal of Chemistry and Chemical Engineering
- Vol. 42 (1) , 47-56
Antibacterial and antibiofilm activities of sodium ibuprofen- and paracetamol-loaded nanofibers
Nanofibers loaded with pharmaceutical agents for various medical purposes have become more important in recent years because of their advantages, such as control on release, gas permeability, high surface area, and lightweight matrices. In the present study, polylactic acid (PLA)-gelatin (Gel) nanofibers were successfully loaded with Ibuprofen-Na/Paracetamol (henceforth Ibu-Na and Par, respectively) by electrospinning. The nanofibers were characterized by scanning electron microscopy (SEM) and Fourier transform infrared (FTIR) spectroscopy. The Ibu-Na/Par content of the nanofibers was determined by using high-performance liquid chromatography (HPLC). Their antibacterial activities were tested against Enterococcus faecalis ATCC 29212, Staphylococcus aureus ATCC 25923, Escherichia coli ATCC 25922, and Pseudomonas aeruginosa PA01, opportunistic pathogenic bacteria which are frequently associated with infections. Moreover, their antibiofilm activities against P. aeruginosa and E. faecalis were also investigated. The Ibu-Na-containing nanofibers exhibited antibacterial activity against S. aureus, E. coli, and E. faecalis. The inhibition zone diameters of PLA-Gel-Ibu-Na 300 against E. faecalis, S. aureus, and E. coli were calculated to be 23.0 ± 2.1 mm, 18.0 ± 1.5 mm, and 12.0 ± 1.2 mm, respectively. It was found that PLA-Gel-Ibu-Na 300 and PLA-Gel-Par 300 nanofibers’ capacity to show biofilm formation inhibition originated remarkable effects on P. aeruginosa, which were found to be 48 % and 50.4 %, respectively. This study indicated that Ibu-Na/Par-loaded nanofibers are promising materials for wound healing applications.
- 28 April 2023
- Published by Society of Chemists and Technologists of Macedonia in Macedonian Journal of Chemistry and Chemical Engineering
- Vol. 42 (1) , 47-56
Open AccessAntibacterial and antibiofilm activities of sodium ibuprofen- and paracetamol-loaded nanofibers
Nanofibers loaded with pharmaceutical agents for various medical purposes have become more important in recent years because of their advantages, such as control on release, gas permeability, high surface area, and lightweight matrices. In the present study, polylactic acid (PLA)-gelatin (Gel) nanofibers were successfully loaded with Ibuprofen-Na/Paracetamol (henceforth Ibu-Na and Par, respectively) by electrospinning. The nanofibers were characterized by scanning electron microscopy (SEM) and Fourier transform infrared (FTIR) spectroscopy. The Ibu-Na/Par content of the nanofibers was determined by using high-performance liquid chromatography (HPLC). Their antibacterial activities were tested against Enterococcus faecalis ATCC 29212, Staphylococcus aureus ATCC 25923, Escherichia coli ATCC 25922, and Pseudomonas aeruginosa PA01, opportunistic pathogenic bacteria which are frequently associated with infections. Moreover, their antibiofilm activities against P. aeruginosa and E. faecalis were also investigated. The Ibu-Na-containing nanofibers exhibited antibacterial activity against S. aureus, E. coli, and E. faecalis. The inhibition zone diameters of PLA-Gel-Ibu-Na 300 against E. faecalis, S. aureus, and E. coli were calculated to be 23.0 ± 2.1 mm, 18.0 ± 1.5 mm, and 12.0 ± 1.2 mm, respectively. It was found that PLA-Gel-Ibu-Na 300 and PLA-Gel-Par 300 nanofibers’ capacity to show biofilm formation inhibition originated remarkable effects on P. aeruginosa, which were found to be 48 % and 50.4 %, respectively. This study indicated that Ibu-Na/Par-loaded nanofibers are promising materials for wound healing applications.
- 2 January 2020
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 100 (4) , 432-450
A novel biosensing system based on ITO-single use electrode for highly sensitive analysis of VEGF
Nowadays, breast cancer is one of the riskiest and common cancer types. The early diagnosis of breast cancer is very important just as in other cancer types. Recent investigations demonstrate the biomarkers can be useful for the disease phase. These biomarkers are the very important materials to determine the good or bad diagnostic of the patient. Vascular endothelial growth factor is considered the most powerful mitogen for endothelial cells and also is an important regulator of vascular permeability and angiogenesis. In the frame of this study, it is purposed to design an electrochemical immunosensor system based on indium-tin oxide covered polyethylene terephthalate electrode. Electrochemical impedance spectroscopy, which is a quick and sensitive method, was used for vascular endothelial growth factor determination. Electrochemical impedance spectroscopy and cyclic voltammetry techniques were used in all optimisation processes of the produced biosensor. Scanning electron microscopy images, energy-dispersive X-ray spectra and mapping, atomic force microscopy and infrared spectra were examined to support the optimisation studies and to reveal surface morphology and chemical components. In the electrochemical characterisation studies, repeatability, reproducibility, storage, regeneration, single frequency impedance, square wave voltammetry and Kramer’s-Kronig transform studies were performed. The measurements were taken in human serum.
- 2 January 2020
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 100 (4) , 432-450
A novel biosensing system based on ITO-single use electrode for highly sensitive analysis of VEGF
Nowadays, breast cancer is one of the riskiest and common cancer types. The early diagnosis of breast cancer is very important just as in other cancer types. Recent investigations demonstrate the biomarkers can be useful for the disease phase. These biomarkers are the very important materials to determine the good or bad diagnostic of the patient. Vascular endothelial growth factor is considered the most powerful mitogen for endothelial cells and also is an important regulator of vascular permeability and angiogenesis. In the frame of this study, it is purposed to design an electrochemical immunosensor system based on indium-tin oxide covered polyethylene terephthalate electrode. Electrochemical impedance spectroscopy, which is a quick and sensitive method, was used for vascular endothelial growth factor determination. Electrochemical impedance spectroscopy and cyclic voltammetry techniques were used in all optimisation processes of the produced biosensor. Scanning electron microscopy images, energy-dispersive X-ray spectra and mapping, atomic force microscopy and infrared spectra were examined to support the optimisation studies and to reveal surface morphology and chemical components. In the electrochemical characterisation studies, repeatability, reproducibility, storage, regeneration, single frequency impedance, square wave voltammetry and Kramer’s-Kronig transform studies were performed. The measurements were taken in human serum.