Diederik Maas
Diederik Maas has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Emile van Veldhoven
†TNO - van Leeuwenhoek Laboratory, 2826 CK Delft, The Netherlands
2 shared publicationsAdam (Chung Bin) Chuang
Netherlands Organisation for Applied Scientific Research – TNO
1 shared publicationAmir Raveh
Intel Israel (74) Ltd. , P.O. Box 1659, Haifa 31015, Israel
1 shared publication- Chad Rue
FEI Company
1 shared publication - Daniel Fishman
Nova Measuring Instruments, LTD, Rehovot, Israel
1 shared publication E. van Veldhoven
Netherlands Organization for Applied Scientific Research, TNO, Stieltjesweg 1, 2628CK Delft, The Netherlands
1 shared publication
Latest Publications
- 3 November 2025
- Published by Elsevier in Ultramicroscopy
- Vol. 280, 114267
An electrostatic aberration corrector for improved Low-Voltage SEM imaging
- 3 November 2025
- Published by Elsevier in Ultramicroscopy
- Vol. 280, 114267
An electrostatic aberration corrector for improved Low-Voltage SEM imaging
- 24 June 2025
- Published by Technical Association of Photopolymers, Japan in Journal of Photopolymer Science and Technology
- Vol. 38 (3) , 253-258
Chemically Resolved IR-AFM Metrology of Sub-25 nm Half-Pitch Patterns in Self-Assembled Block Co-Polymers
Resist stochastics ultimately limit patterning, a result of interplay of resist composition, exposure, bake and development. Metrologies like OCD and CD-SEM only measure uniformity after development, offering limited process control. Each step modifies molecular bonds, leaving IR (5-20 μm) fingerprints in activated chemical structures. When combining IR & AFM, nearfield effects resolve alterations at the nm scale. We show how IR-AFM offers chemical selectivity and lateral resolution to resolve modifications in latent DSA and EUVL images, even before PEB and development. Metrology data from these images facilitate improved process control.
- 24 June 2025
- Published by Technical Association of Photopolymers, Japan in Journal of Photopolymer Science and Technology
- Vol. 38 (3) , 253-258
Chemically Resolved IR-AFM Metrology of Sub-25 nm Half-Pitch Patterns in Self-Assembled Block Co-Polymers
Resist stochastics ultimately limit patterning, a result of interplay of resist composition, exposure, bake and development. Metrologies like OCD and CD-SEM only measure uniformity after development, offering limited process control. Each step modifies molecular bonds, leaving IR (5-20 μm) fingerprints in activated chemical structures. When combining IR & AFM, nearfield effects resolve alterations at the nm scale. We show how IR-AFM offers chemical selectivity and lateral resolution to resolve modifications in latent DSA and EUVL images, even before PEB and development. Metrology data from these images facilitate improved process control.
- Open Access
- 1 February 2022
- Published by Springer Nature in Research Square
Highly spatially resolved chemical metrology on latent resist images
Patterning photoresist with extreme control over dose and placement is the first crucial step in semiconductor manufacturing. However, how can the activation of modern complex resist components be accurately measured at sufficient spatial resolution? No exposed nanometre-scale resist pattern is sufficiently sturdy to unaltered withstand inspection by intense photon or electron beams, not even after processing and development. This paper presents experimental proof that infrared atomic force microscopy (IR-AFM) is sufficiently sensitive and gentle to chemically record vulnerable yet valuable lithographic patterns in a chemically amplified resist after exposure prior to development. Accordingly, IR-AFM metrology provides long-sought insights into changes in the chemical and spatial distribution per component in a latent resist image, both directly after exposure and during processing. With these to-be-gained understandings, a disruptive acceleration of resist design and processing is expected.
- 1 February 2022
- Published by Springer Nature in Research Square
Open AccessHighly spatially resolved chemical metrology on latent resist images
Patterning photoresist with extreme control over dose and placement is the first crucial step in semiconductor manufacturing. However, how can the activation of modern complex resist components be accurately measured at sufficient spatial resolution? No exposed nanometre-scale resist pattern is sufficiently sturdy to unaltered withstand inspection by intense photon or electron beams, not even after processing and development. This paper presents experimental proof that infrared atomic force microscopy (IR-AFM) is sufficiently sensitive and gentle to chemically record vulnerable yet valuable lithographic patterns in a chemically amplified resist after exposure prior to development. Accordingly, IR-AFM metrology provides long-sought insights into changes in the chemical and spatial distribution per component in a latent resist image, both directly after exposure and during processing. With these to-be-gained understandings, a disruptive acceleration of resist design and processing is expected.
- 16 June 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 127 (23) , 234904
Miniature electron beam separator based on three stacked dipoles
We designed and built a compact bi-axial electron beam separator. This separator is an indispensable electron optical element in the development of MEMS-mirror-based miniaturized concepts for quantum electron microscopy (QEM) and aberration-corrected low-voltage scanning electron microscopy (AC-SEM). The separator provides the essential cycling of the electron beam between the two parallel optical axes that are part of these systems. This requires crossed electric and magnetic fields perpendicular to the beam path, as can be found in Wien-filter type beam separators. In our miniaturized QEM or AC-SEM concepts, the parallel axes are separated by only 1 mm. Conventional Wien-filter-based beam separator concepts rely on in-plane electric and magnetic multipole electrode configurations that are larger than the restricted available volume in these miniaturized QEM/AC-SEM systems. Our compact beam separator design introduces three stacked dipole electrode layers, which enables simultaneous beam separation at two parallel axes that are in close proximity. The outer layer electrodes maintain an electric field for which the direction on the one axis is opposed to that on the other axis. The middle layer generates a perpendicularly oriented magnetic field that spans both axes. The total field configuration enables the deflection of the beam on one axis and simultaneously provides a straight passage on the other axis. The deflection strength and distortion fields of the beam separator are experimentally obtained with a 2 keV electron beam energy. The results validate the use of the beam separator for electron energies up to 5 keV and deflection angles up to 100 mrad.
- 16 June 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 127 (23) , 234904
Miniature electron beam separator based on three stacked dipoles
We designed and built a compact bi-axial electron beam separator. This separator is an indispensable electron optical element in the development of MEMS-mirror-based miniaturized concepts for quantum electron microscopy (QEM) and aberration-corrected low-voltage scanning electron microscopy (AC-SEM). The separator provides the essential cycling of the electron beam between the two parallel optical axes that are part of these systems. This requires crossed electric and magnetic fields perpendicular to the beam path, as can be found in Wien-filter type beam separators. In our miniaturized QEM or AC-SEM concepts, the parallel axes are separated by only 1 mm. Conventional Wien-filter-based beam separator concepts rely on in-plane electric and magnetic multipole electrode configurations that are larger than the restricted available volume in these miniaturized QEM/AC-SEM systems. Our compact beam separator design introduces three stacked dipole electrode layers, which enables simultaneous beam separation at two parallel axes that are in close proximity. The outer layer electrodes maintain an electric field for which the direction on the one axis is opposed to that on the other axis. The middle layer generates a perpendicularly oriented magnetic field that spans both axes. The total field configuration enables the deflection of the beam on one axis and simultaneously provides a straight passage on the other axis. The deflection strength and distortion fields of the beam separator are experimentally obtained with a 2 keV electron beam energy. The results validate the use of the beam separator for electron energies up to 5 keV and deflection angles up to 100 mrad.
- Open Access
- 21 February 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (5) , 4621-4631
Fast resist-activation dosimetry for extreme ultra-violet lithography
Due to the rather broad band emission spectrum of the extremely hot plasma in its extreme ultra-violet (EUV) source, an EUV lithography scanner also projects out-of-band vacuum- and deep-UV (OoB V/DUV) light on the photoresist on a wafer. As this type of uncontrolled and undesirable light can activate resist chemistry, it will impair the critical dimension uniformity of the patterns, especially across the borders of the fields. Hence, OoB V/DUV quantification technology is required in the pre-production phase. For this reason, the systematic characterization of the EUV-source emission spectrum and the spatial profile of the light as projected on the wafer is indispensable to sustain stable integrated circuit production with EUV lithography. This paper introduces an in-band EUV and OoB V/DUV dosimetry method that is based on enhanced energy sensitivity by resist contrast (EESRC). This dosimetry method is applied in an EUV lithography tool to quantitatively analyze the spatial distribution the resist activation by in-band EUV and OoB V/DUV light, under several exposure conditions. This pragmatic approach can replace the current best-practice of measuring the full spectrum of an EUV light source.
- 21 February 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (5) , 4621-4631
Open AccessFast resist-activation dosimetry for extreme ultra-violet lithography
Due to the rather broad band emission spectrum of the extremely hot plasma in its extreme ultra-violet (EUV) source, an EUV lithography scanner also projects out-of-band vacuum- and deep-UV (OoB V/DUV) light on the photoresist on a wafer. As this type of uncontrolled and undesirable light can activate resist chemistry, it will impair the critical dimension uniformity of the patterns, especially across the borders of the fields. Hence, OoB V/DUV quantification technology is required in the pre-production phase. For this reason, the systematic characterization of the EUV-source emission spectrum and the spatial profile of the light as projected on the wafer is indispensable to sustain stable integrated circuit production with EUV lithography. This paper introduces an in-band EUV and OoB V/DUV dosimetry method that is based on enhanced energy sensitivity by resist contrast (EESRC). This dosimetry method is applied in an EUV lithography tool to quantitatively analyze the spatial distribution the resist activation by in-band EUV and OoB V/DUV light, under several exposure conditions. This pragmatic approach can replace the current best-practice of measuring the full spectrum of an EUV light source.
- 1 October 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (10) , 103702
Sub-50 nm metrology on extreme ultra violet chemically amplified resist—A systematic assessment
With lithographic patterning dimensions decreasing well below 50 nm, it is of high importance to understand metrology at such small scales. This paper presents results obtained from dense arrays of contact holes (CHs) with various Critical Dimension (CD) between 15 and 50 nm, as patterned in a chemically amplified resist using an ASML EUV scanner and measured at ASML and TNO. To determine the differences between various (local) CD metrology techniques, we conducted an experiment using optical scatterometry, CD-Scanning Electron Microscopy (CD-SEM), Helium ion Microscopy (HIM), and Atomic Force Microscopy (AFM). CD-SEM requires advanced beam scan strategies to mitigate sample charging; the other tools did not need that. We discuss the observed main similarities and differences between the various techniques. To this end, we assessed the spatial frequency content in the raw images for SEM, HIM, and AFM. HIM and AFM resolve the highest spatial frequencies, which are attributed to the more localized probe-sample interaction for these techniques. Furthermore, the SEM, HIM, and AFM waveforms are analyzed in detail. All techniques show good mutual correlation, albeit the reported CD values systematically differ significantly. HIM systematically reports a 25% higher CD uniformity number than CD-SEM for the same arrays of CHs, probably because HIM has a higher resolution than the CD-SEM used in this assessment. A significant speed boost for HIM and AFM is required before these techniques are to serve the demanding industrial metrology applications like optical critical dimension and CD-SEM do nowadays.
- 1 October 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 86 (10) , 103702
Sub-50 nm metrology on extreme ultra violet chemically amplified resist—A systematic assessment
With lithographic patterning dimensions decreasing well below 50 nm, it is of high importance to understand metrology at such small scales. This paper presents results obtained from dense arrays of contact holes (CHs) with various Critical Dimension (CD) between 15 and 50 nm, as patterned in a chemically amplified resist using an ASML EUV scanner and measured at ASML and TNO. To determine the differences between various (local) CD metrology techniques, we conducted an experiment using optical scatterometry, CD-Scanning Electron Microscopy (CD-SEM), Helium ion Microscopy (HIM), and Atomic Force Microscopy (AFM). CD-SEM requires advanced beam scan strategies to mitigate sample charging; the other tools did not need that. We discuss the observed main similarities and differences between the various techniques. To this end, we assessed the spatial frequency content in the raw images for SEM, HIM, and AFM. HIM and AFM resolve the highest spatial frequencies, which are attributed to the more localized probe-sample interaction for these techniques. Furthermore, the SEM, HIM, and AFM waveforms are analyzed in detail. All techniques show good mutual correlation, albeit the reported CD values systematically differ significantly. HIM systematically reports a 25% higher CD uniformity number than CD-SEM for the same arrays of CHs, probably because HIM has a higher resolution than the CD-SEM used in this assessment. A significant speed boost for HIM and AFM is required before these techniques are to serve the demanding industrial metrology applications like optical critical dimension and CD-SEM do nowadays.
- 9 April 2014
- Published by Springer Nature in MRS Bulletin
- Vol. 39 (4) , 336-341
High-resolution direct-write patterning using focused ion beams
- 9 April 2014
- Published by Springer Nature in MRS Bulletin
- Vol. 39 (4) , 336-341
High-resolution direct-write patterning using focused ion beams
- 3 April 2013
- Published by Springer Nature in Journal of Materials Research
- Vol. 28 (8) , 1013-1020
Novel nanosample preparation with a helium ion microscope
- 3 April 2013
- Published by Springer Nature in Journal of Materials Research
- Vol. 28 (8) , 1013-1020
Novel nanosample preparation with a helium ion microscope
- 1 July 2012
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 30 (4)
Structural characterization of He ion microscope platinum deposition and sub-surface silicon damage
In this paper we studied helium ion beam induced deposition (HIBID) of Pt on a silicon wafer using the recently commercialized helium ion microscope (HIM) at 25 kV and low beam currents. The motivation of this work was to understand the impact of light, inert helium ions on deposition rate and structure purity, with some implications on the usefulness of HIM nano-machining for circuit modification. Two Pt-rich deposits with sub-micron dimensions were grown with HIBID at different ion beam currents. The pillar and substrate structure were studied using bright and dark field TEM images. The authors analyzed metal purity profile of the HIBID deposit on height using energy dispersive x-ray spectroscopy. The maximum Pt content measured reached 41%, which is the highest measured metal content of a HIBID-grown structure. TEM studies of the sub-surface damage to the Si shows more damage below the deposit grown at a higher beam current. The differences in amorphization layer thickness between the two different beam currents are discussed. A comparison to Pt deposition by Ga FIB and electron beam induced deposition is provided, along with conclusions regarding the usage of HIBID technology for circuit modification.
- 1 July 2012
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 30 (4)
Structural characterization of He ion microscope platinum deposition and sub-surface silicon damage
In this paper we studied helium ion beam induced deposition (HIBID) of Pt on a silicon wafer using the recently commercialized helium ion microscope (HIM) at 25 kV and low beam currents. The motivation of this work was to understand the impact of light, inert helium ions on deposition rate and structure purity, with some implications on the usefulness of HIM nano-machining for circuit modification. Two Pt-rich deposits with sub-micron dimensions were grown with HIBID at different ion beam currents. The pillar and substrate structure were studied using bright and dark field TEM images. The authors analyzed metal purity profile of the HIBID deposit on height using energy dispersive x-ray spectroscopy. The maximum Pt content measured reached 41%, which is the highest measured metal content of a HIBID-grown structure. TEM studies of the sub-surface damage to the Si shows more damage below the deposit grown at a higher beam current. The differences in amorphization layer thickness between the two different beam currents are discussed. A comparison to Pt deposition by Ga FIB and electron beam induced deposition is provided, along with conclusions regarding the usage of HIBID technology for circuit modification.