KWKento Watanabe

Kento Watanabe

*This is an algorithmically generated author record based on publicly available information.

Kento Watanabe has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Validation of Wearable Device Consisting of a Smart Shirt with Built-In Bioelectrodes and a Wireless Transmitter for Heart Rate Monitoring in Light to Moderate Physical Work

    by Yuki Hashimoto, Rieko Sato, Kazuhiko Takagahara, Takako Ishihara, Kento Watanabe, Hiroyoshi Togo

    Real-time monitoring of heart rate is useful for monitoring workers. Wearable heart rate monitors worn on the upper body are less susceptible to artefacts caused by arm and wrist movements than popular wristband-type sensors using the photoplethysmography method. Therefore, they are considered suitable for stable and accurate measurement for various movements. In this study, we conducted an experiment to verify the accuracy of our developed and commercially available wearable heart rate monitor consisting of a smart shirt with bioelectrodes and a transmitter, assuming a real-world work environment with physical loads. An exercise protocol was designed to light to moderate intensity according to international standards because no standard exercise protocol for the validation simulating these works has been reported. This protocol includes worker-specific movements such as applying external vibration and lifting and lowering loads. In the experiment, we simultaneously measured the instantaneous heart rate with the above wearable device and a Holter monitor as a reference to evaluate mean absolute percentage error (MAPE). The MAPE was 0.92% or less for all exercise protocols conducted. This value indicates that the accuracy of the wearable device is high enough for use in real-world cases of physical load in light to moderate intensity tasks such as those in our experimental protocol. In addition, the experimental protocol and measurement data devised in this study can be used as a benchmark for other wearable heart rate monitors for use for similar purposes.


  • Heartbeat Interval Error Compensation Method for Low Sampling Rates Photoplethysmography Sensors

    by Kento Watanabe, Shintaro Izumi, Yuji Yano, Hiroshi Kawaguchi, Masahiko Yoshimoto

    This study presents a method for improving the heartbeat interval accuracy of photoplethysmographic (PPG) sensors at ultra-low sampling rates. Although sampling rate reduction can extend battery life, it increases the sampling error and degrades the accuracy of the extracted heartbeat interval. To overcome these drawbacks, a sampling-error compensation method is proposed in this study. The sampling error is reduced by using linear interpolation and autocorrelation based on the waveform similarity of heartbeats in PPG. Furthermore, this study introduces two-line approximation and first derivative PPG (FDPPG) to improve the waveform similarity at ultra-low sampling rates. The proposed method was evaluated using measured PPG and reference electrocardiogram (ECG) of seven subjects. The results reveal that the mean absolute error (MAE) of 4.11 ms was achieved for the heartbeat intervals at a sampling rate of 10 Hz, compared with 1 kHz ECG sampling. The heartbeat interval error was also evaluated based on a heart rate variability (HRV) analysis. Furthermore, the mean absolute percentage error (MAPE) of the low-frequency/highfrequency (LF/HF) components obtained from the 10-Hz PPG is shown to decrease from 38.3% to 3.3%. This error is small enough for practical HRV analysis.


  • A Low-Power Photoplethysmography Sensor using Correlated Double Sampling and Reference Readout Circuit

    by Kana Sasai, Shintaro Izumi, Kento Watanabe, Yuji Yano, Hiroshi Kawaguchi, Masahiko Yoshimoto

    This paper describes a low-power photoplethysmography (PPG) sensor circuit using a current integration circuit. PPG sensors are widely used in modern healthcare products for monitoring cardiovascular information. However, the PPG circuits generally have a large power consumption because the LED driver consumes considerable energy to obtain the required amount of reflected light from the human body. A simple way to reduce the power requirements of PPG circuits is to lower the duty cycle of the LED through intermittent operation of the LED. However, this causes accuracy degradation because the target signal is susceptible to interference from various noises. To reduce the power consumption while maintaining accuracy, the correlated double sampling (CDS) method that we introduced in our previous work was used. In our previous work, wherein the PPG was placed on fingertips, the heartbeat error was 5 ms. This paper presents a signal-to-noise ratio improvement method for CDS by using a PPG sensor with current integration circuits. This enables SNR improvement and measurements to be taken from any part of the body. In the proposed method, the target PPG signal is extracted by canceling noise and DC components using two sensors. The proposed circuit was evaluated using actual measurements and the total consumption current was 26.9 μA. The root mean square error of the heartbeat interval was 4.27 ms, even though the sensor was worn on the wrist during the experiment.


  • A 5-ms Error, 22-μA Photoplethysmography Sensor using Current Integration Circuit and Correlated Double Sampling

    by Kento Watanabe, Shintaro Izumi, Yuji Yano, Hiroshi Kawaguchi, Masahiko Yoshimoto

    This paper presents a low-power Photoplethysmography (PPG) sensing method. The PPG is commonly used in recent wearable devices to detect cardiovascular information including heartbeat. The heartbeat is useful for physical activity and stress monitoring. However, the PPG circuit consumes large power because it consists of LED and photodiode. To reduce its power consumption without accuracy degradation, a cooperative design of circuits and algorithms is proposed in this work. A straightforward way to reduce the power is intermittent driving of LED, but there is a disadvantage that the signal is contaminated by a noise while circuit switching. To overcome this problem, we introduce correlated double sampling (CDS) method, which samples an integration circuit output twice with short intervals after the LED turns on and uses the difference of these voltage. Furthermore, an up-conversion method using linear interpolation, and an error correction using autocorrelation are introduced. The proposed PPG sensor, which consists of the LED, the photodiode, the current integration circuit, a CMOS switch, an A/D converter, and an MCU, is prototyped. It is evaluated by actual measurement with 22-year-old subject. The measurement results show that 22-μA total current consumption is achieved with 5-ms mean absolute error.


  • Asymmetric anionic polymerization of 2,7‐bis(4‐t‐butylphenyl)fluoren‐9‐ylmethyl methacrylate and photoinduced structural transition of the obtained polymer

    by Kento Watanabe, Takeshi Sakamoto, Tamaki Nakano

    2,7-Bis(4-t-butylphenyl)fluoren-9-ylmethyl methacrylate (BBPFMMA) was synthesized as a new candidate of a bulky monomer suitable for asymmetric anionic polymerization (IUPAC nomenclature: asymmetric helix-chirogenic polymerization) leading to a preferred-handed helical, optically active polymer. The new monomer was polymerized using the complex of 9-fluorenyllithium and (S)-(+)-1-(2-pyrrolidinylmethyl)pyrrolidine in toluene at −78°C. As opposed to the original intention to obtain a polymethacrylate, the monomer seemed to undergo structural transition (decomposition) giving 2,7-bis(4-t-butylphenyl)dibenzofulvene and the obtained polymer was most probably a terpolymer of BBPFMMA, 2,7-bis(4-t-butylphenyl)dibenzofulvene, and methacrylic acid. The obtained polymer showed circular dichroism (CD) spectra, indicating that chirality had been introduced to the copolymer chain during the course of polymerization. On photo irradiation, the polymer underwent a structural transition involving a remarkable decrease in apparent molecular weight measured by size-exclusion chromatography (SEC) and changes in FT-IR spectral patterns. However, the CD spectrum of the polymer was not obviously altered by irradiation, indicating that polymer chirality is not affected by light. Chirality, 2011.