XZXiahan Zhou

Xiahan Zhou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiahan Zhou has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • IEEE SSCS Young Professionals and Women in Circuits Mentoring Event at CICC 2024 [Society News]

    by Xiahan Zhou

    Provides society information that may include news, reviews or technical notes that should be of interest to practitioners and researchers.

  • A 9.7-nTᵣₘₛ, 704-ms Magnetic Biosensor Front-End for Detecting Magneto-Relaxation

    by Xiahan Zhou, Enhan Mai, Michael Sveiven, Corentin Pochet, Haowei Jiang, Chih-Cheng Huang, Drew A. Hall

    This article reports a low-noise magnetic sensor front-end with an 18-bit Zoom ADC for detecting temporal magnetic nanoparticle (MNP) relaxation. Techniques such as dynamic element matching (DEM) and magnetoresistive correlated double sampling (MRCDS) are proposed to remove the sensor and analog front-end (AFE) 1/ ${f}$ noise while a fast-settling Miller compensation (FSMC) technique is proposed to reduce the amplifier power. Collectively, these result in state-of-the-art input-referred noise performance (9.7 nT rms ) and a figure-of-merit (FoM) that is 6.6 $\times $ and 210 $\times $ better than previously reported magnetic sensor and relaxation-based AFEs, respectively. A relaxation-based magnetic immunoassay (MIA) was performed to demonstrate the concept. This design is implemented in a 0.18- $\mu \text{m}$ CMOS process and consumes 4.32 mW from a 1.8-V supply.


  • Open Access

    An aptamer-based magnetic flow cytometer using matched filtering

    by Chih-Cheng Huang, Partha Ray, Matthew Chan, Xiahan Zhou, Drew A. Hall

    Facing unprecedented population-ageing, the management of noncommunicable diseases (NCDs) urgently needs a point-of-care (PoC) testing infrastructure. Magnetic flow cytometers are one such solution for rapid cancer cellular detection in a PoC setting. In this work, we report a giant magnetoresistive spin-valve (GMR SV) biosensor array with a multi-stripe sensor geometry and matched filtering to improve detection accuracy without compromising throughput. The carefully designed sensor geometry generates a characteristic signature when cells labeled with magnetic nanoparticles (MNPs) pass by thus enabling multi-parametric measurement like optical flow cytometers (FCMs). Enumeration and multi-parametric information were successfully measured across two decades of throughput. 10-µm polymer microspheres were used as a biomimetic model where MNPs and MNP-decorated polymer conjugates were flown over the GMR SV sensor array and detected with a signal-to-noise ratio (SNR) as low as 2.5 dB due to the processing gain afforded by the matched filtering. The performance was compared against optical observation, exhibiting a 92% detection efficiency. The system achieved a 95% counting accuracy for biomimetic models and 98% for aptamer-based pancreatic cancer cell detection. This system demonstrates the ability to perform reliable PoC diagnostics towards the benefit for NCD control plans.


  • A CMOS Magnetoresistive Sensor Front-End With Mismatch-Tolerance and Sub-ppm Sensitivity for Magnetic Immunoassays

    by Xiahan Zhou, Michael Sveiven, Drew A. Hall

    Magnetic biosensing is an emerging technique for ultra-sensitive point-of-care (PoC) biomolecular detection. However, the large baseline-to-signal ratio and sensor-to-sensor mismatch in magnetoresistive (MR) biosensors severely complicates the design of the analog front-end (AFE) due to the high dynamic range (DR) required. The proposed AFE addresses these issues through new architectural and circuit level techniques including fast settling duty-cycle resistors (DCRs) to reduce readout time and a high frequency interference rejection (HFIR) sampling technique embedded in the ADC to relax the DR requirement. The AFE achieves an input-referred noise of 46.4 nT/√Hz, an input-referred baseline of less than 0.235 mT, and a readout time of 11 ms while consuming just 1.39 mW. Implemented in a 0.18 μm CMOS process, this work has state-of-the-art performance with 22.7× faster readout time, >7.8× lower baseline, and 2.3× lower power than previously reported MR sensor AFEs.