Jan Putzeys
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jan Putzeys has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
- Timothy D. Harris
Johns Hopkins University
7 shared publications - Carolina Mora Lopez
IMEC
6 shared publications - Barundeb Dutta
IMEC, Leuven, Belgium
5 shared publications - John O’CAllaghan
IMEC, Leuven, Belgium
4 shared publications - Marleen Welkenhuysen
IMEC, Leuven, Belgium
4 shared publications Bill Karsh
Janlia Research Campus
3 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 1 June 2026
- Published by Springer Nature in Nature Methods
- Vol. 23 (6) , 1207-1216
Neuropixels Opto: combining high-resolution electrophysiology and optogenetics
High-resolution extracellular electrophysiology is the gold standard for recording spikes from distributed neural populations and is especially powerful when combined with optogenetics for manipulation of specific cell types with high temporal resolution. We integrated these approaches into prototype Neuropixels Opto probes, which combine electronic and photonic circuits. These devices pack 960 electrical recording sites and two sets of 14 light emitters onto a 70-μm-wide, 1-cm-long shank, allowing spatially addressable optogenetic stimulation with blue and red light. In mouse cortex, Neuropixels Opto probes delivered high-quality recordings together with spatially addressable optogenetics, differentially activating or silencing neurons at distinct cortical depths. In the mouse striatum and other deep structures, Neuropixels Opto probes delivered efficient optotagging, facilitating the identification of two cell types in parallel. Neuropixels Opto probes represent a promising tool for recording, identifying and manipulating neuronal populations.
- 1 June 2026
- Published by Springer Nature in Nature Methods
- Vol. 23 (6) , 1207-1216
Top Cited PapersOpen AccessNeuropixels Opto: combining high-resolution electrophysiology and optogenetics
High-resolution extracellular electrophysiology is the gold standard for recording spikes from distributed neural populations and is especially powerful when combined with optogenetics for manipulation of specific cell types with high temporal resolution. We integrated these approaches into prototype Neuropixels Opto probes, which combine electronic and photonic circuits. These devices pack 960 electrical recording sites and two sets of 14 light emitters onto a 70-μm-wide, 1-cm-long shank, allowing spatially addressable optogenetic stimulation with blue and red light. In mouse cortex, Neuropixels Opto probes delivered high-quality recordings together with spatially addressable optogenetics, differentially activating or silencing neurons at distinct cortical depths. In the mouse striatum and other deep structures, Neuropixels Opto probes delivered efficient optotagging, facilitating the identification of two cell types in parallel. Neuropixels Opto probes represent a promising tool for recording, identifying and manipulating neuronal populations.
- Top Cited PapersOpen Access
- 23 June 2025
- Published by Springer Nature in Nature Neuroscience
- Vol. 28 (7) , 1562-1575
Large-scale high-density brain-wide neural recording in nonhuman primates
High-density silicon probes have transformed neuroscience by enabling large-scale neural recordings at single-cell resolution. However, existing technologies have provided limited functionality in nonhuman primates (NHPs) such as macaques. In the present report, we describe the design, fabrication and performance of Neuropixels 1.0 NHP, a high-channel electrode array designed to enable large-scale acute recording throughout large animal brains. The probe features 4,416 recording sites distributed along a 45-mm shank. Experimenters can programmably select 384 recording channels, enabling simultaneous multi-area recording from thousands of neurons with single or multiple probes. This technology substantially increases scalability and recording access relative to existing technologies and enables new classes of experiments that involve electrophysiological mapping of brain areas at single-neuron and single-spike resolution, measurement of spike–spike correlations between cells and simultaneous brain-wide recordings at scale.
- 23 June 2025
- Published by Springer Nature in Nature Neuroscience
- Vol. 28 (7) , 1562-1575
Top Cited PapersOpen AccessLarge-scale high-density brain-wide neural recording in nonhuman primates
High-density silicon probes have transformed neuroscience by enabling large-scale neural recordings at single-cell resolution. However, existing technologies have provided limited functionality in nonhuman primates (NHPs) such as macaques. In the present report, we describe the design, fabrication and performance of Neuropixels 1.0 NHP, a high-channel electrode array designed to enable large-scale acute recording throughout large animal brains. The probe features 4,416 recording sites distributed along a 45-mm shank. Experimenters can programmably select 384 recording channels, enabling simultaneous multi-area recording from thousands of neurons with single or multiple probes. This technology substantially increases scalability and recording access relative to existing technologies and enables new classes of experiments that involve electrophysiological mapping of brain areas at single-neuron and single-spike resolution, measurement of spike–spike correlations between cells and simultaneous brain-wide recordings at scale.
- Open Access
Neuropixels Opto: Combining high-resolution electrophysiology and optogenetics
High-resolution extracellular electrophysiology is the gold standard for recording spikes from distributed neural populations, and is especially powerful when combined with optogenetics for manipulation of specific cell types with high temporal resolution. We integrated these approaches into prototype Neuropixels Opto probes, which combine electronic and photonic circuits. These devices pack 960 electrical recording sites and two sets of 14 light emitters onto a 70 μm wide, 1 cm long shank, allowing spatially addressable optogenetic stimulation with blue and red light. In mouse cortex, Neuropixels Opto probes delivered high-quality recordings together with spatially addressable optogenetics, differentially activating or silencing neurons at distinct cortical depths. In mouse striatum and other deep structures, Neuropixels Opto probes delivered efficient optotagging, facilitating the identification of two cell types in parallel. Neuropixels Opto probes represent an unprecedented tool for recording, identifying, and manipulating neuronal populations.
Open AccessNeuropixels Opto: Combining high-resolution electrophysiology and optogenetics
High-resolution extracellular electrophysiology is the gold standard for recording spikes from distributed neural populations, and is especially powerful when combined with optogenetics for manipulation of specific cell types with high temporal resolution. We integrated these approaches into prototype Neuropixels Opto probes, which combine electronic and photonic circuits. These devices pack 960 electrical recording sites and two sets of 14 light emitters onto a 70 μm wide, 1 cm long shank, allowing spatially addressable optogenetic stimulation with blue and red light. In mouse cortex, Neuropixels Opto probes delivered high-quality recordings together with spatially addressable optogenetics, differentially activating or silencing neurons at distinct cortical depths. In mouse striatum and other deep structures, Neuropixels Opto probes delivered efficient optotagging, facilitating the identification of two cell types in parallel. Neuropixels Opto probes represent an unprecedented tool for recording, identifying, and manipulating neuronal populations.
- Open Access
Large-scale high-density brain-wide neural recording in nonhuman primates
High-density, integrated silicon electrodes have begun to transform systems neuroscience, by enabling large-scale neural population recordings with single cell resolution. Existing technologies, however, have provided limited functionality in nonhuman primate species such as macaques, which offer close models of human cognition and behavior. Here, we report the design, fabrication, and performance of Neuropixels 1.0-NHP, a high channel count linear electrode array designed to enable large-scale simultaneous recording in superficial and deep structures within the macaque or other large animal brain. These devices were fabricated in two versions: 4416 electrodes along a 45 mm shank, and 2496 along a 25 mm shank. For both versions, users can programmatically select 384 channels, enabling simultaneous multi-area recording with a single probe. We demonstrate recording from over 3000 single neurons within a session, and simultaneous recordings from over 1000 neurons using multiple probes. This technology represents a significant increase in recording access and scalability relative to existing technologies, and enables new classes of experiments involving fine-grained electrophysiological characterization of brain areas, functional connectivity between cells, and simultaneous brain-wide recording at scale.
Open AccessLarge-scale high-density brain-wide neural recording in nonhuman primates
High-density, integrated silicon electrodes have begun to transform systems neuroscience, by enabling large-scale neural population recordings with single cell resolution. Existing technologies, however, have provided limited functionality in nonhuman primate species such as macaques, which offer close models of human cognition and behavior. Here, we report the design, fabrication, and performance of Neuropixels 1.0-NHP, a high channel count linear electrode array designed to enable large-scale simultaneous recording in superficial and deep structures within the macaque or other large animal brain. These devices were fabricated in two versions: 4416 electrodes along a 45 mm shank, and 2496 along a 25 mm shank. For both versions, users can programmatically select 384 channels, enabling simultaneous multi-area recording with a single probe. We demonstrate recording from over 3000 single neurons within a session, and simultaneous recordings from over 1000 neurons using multiple probes. This technology represents a significant increase in recording access and scalability relative to existing technologies, and enables new classes of experiments involving fine-grained electrophysiological characterization of brain areas, functional connectivity between cells, and simultaneous brain-wide recording at scale.
- 16 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 58 (4) , 949-960
An AC-Coupled 1st-Order Δ-ΔΣ Readout IC for Area-Efficient Neural Signal Acquisition
The current demand for high-channel-count neural-recording interfaces calls for more area- and power-efficient readout architectures that do not compromise other electrical performances. In this article, we present a miniature 128-channel neural recording integrated circuit (NRIC) for the simultaneous acquisition of local field potentials (LFPs) and action potentials (APs), which can achieve a very good compromise between area, power, noise, input range, and electrode dc offset (EDO) cancellation. An ac-coupled 1st-order digitally-intensive$\Delta $ -$\Delta \Sigma $ architecture is proposed to achieve this compromise and to leverage the advantages of a highly-scaled technology node. A prototype NRIC, including 128 channels, a newly-proposed area-efficient bulk-regulated voltage reference, biasing circuits, and a digital control, has been fabricated in 22-nm fully depleted silicon on insulator (FDSOI) CMOS and fully characterized. Our proposed architecture achieves a total area per channel of 0.005 mm2, a total power per channel of 12.57$\mu \text{W}$ , and an input-referred noise of 7.7 ± 0.4$\mu \text{V}_{\mathrm {rms}}$ in the AP band and 11.9 ± 1.1$\mu \text{V}_{\mathrm {rms}}$ in the LFP band. A very good channel-to-channel uniformity is demonstrated by our measurements. The chip has been validated in vivo, demonstrating its capability to successfully record full-band neural signals.- 16 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 58 (4) , 949-960
An AC-Coupled 1st-Order Δ-ΔΣ Readout IC for Area-Efficient Neural Signal Acquisition
The current demand for high-channel-count neural-recording interfaces calls for more area- and power-efficient readout architectures that do not compromise other electrical performances. In this article, we present a miniature 128-channel neural recording integrated circuit (NRIC) for the simultaneous acquisition of local field potentials (LFPs) and action potentials (APs), which can achieve a very good compromise between area, power, noise, input range, and electrode dc offset (EDO) cancellation. An ac-coupled 1st-order digitally-intensive$\Delta $ -$\Delta \Sigma $ architecture is proposed to achieve this compromise and to leverage the advantages of a highly-scaled technology node. A prototype NRIC, including 128 channels, a newly-proposed area-efficient bulk-regulated voltage reference, biasing circuits, and a digital control, has been fabricated in 22-nm fully depleted silicon on insulator (FDSOI) CMOS and fully characterized. Our proposed architecture achieves a total area per channel of 0.005 mm2, a total power per channel of 12.57$\mu \text{W}$ , and an input-referred noise of 7.7 ± 0.4$\mu \text{V}_{\mathrm {rms}}$ in the AP band and 11.9 ± 1.1$\mu \text{V}_{\mathrm {rms}}$ in the LFP band. A very good channel-to-channel uniformity is demonstrated by our measurements. The chip has been validated in vivo, demonstrating its capability to successfully record full-band neural signals.- Open Access
- 2 September 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-14
Electrode pooling can boost the yield of extracellular recordings with switchable silicon probes
State-of-the-art silicon probes for electrical recording from neurons have thousands of recording sites. However, due to volume limitations there are typically many fewer wires carrying signals off the probe, which restricts the number of channels that can be recorded simultaneously. To overcome this fundamental constraint, we propose a method called electrode pooling that uses a single wire to serve many recording sites through a set of controllable switches. Here we present the framework behind this method and an experimental strategy to support it. We then demonstrate its feasibility by implementing electrode pooling on the Neuropixels 1.0 electrode array and characterizing its effect on signal and noise. Finally we use simulations to explore the conditions under which electrode pooling saves wires without compromising the content of the recordings. We make recommendations on the design of future devices to take advantage of this strategy.
- 2 September 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-14
Open AccessElectrode pooling can boost the yield of extracellular recordings with switchable silicon probes
State-of-the-art silicon probes for electrical recording from neurons have thousands of recording sites. However, due to volume limitations there are typically many fewer wires carrying signals off the probe, which restricts the number of channels that can be recorded simultaneously. To overcome this fundamental constraint, we propose a method called electrode pooling that uses a single wire to serve many recording sites through a set of controllable switches. Here we present the framework behind this method and an experimental strategy to support it. We then demonstrate its feasibility by implementing electrode pooling on the Neuropixels 1.0 electrode array and characterizing its effect on signal and noise. Finally we use simulations to explore the conditions under which electrode pooling saves wires without compromising the content of the recordings. We make recommendations on the design of future devices to take advantage of this strategy.
- Top Cited Papers
- 16 April 2021
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 372 (6539) , 258-+
Neuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordings
Recording many neurons for a long time: The ultimate aim of chronic recordings is to sample from the same neuron over days and weeks. However, this goal has been difficult to achieve for large populations of neurons. Steinmetz et al. describe the development and testing of Neuropixels 2.0. This new electrophysiological recording tool is a miniaturized, high-density probe for both acute and long-term experiments combined with sophisticated software algorithms for fully automatic post hoc computational stabilization. The technique also provides a strategy for extending the number of recorded sites beyond the number of available recording channels. In freely moving animals, extremely large numbers of individual neurons could thus be followed and tracked with the same probe for weeks and occasionally months. Science , this issue p. eabf4588
- 16 April 2021
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 372 (6539) , 258-+
Top Cited PapersNeuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordings
Recording many neurons for a long time: The ultimate aim of chronic recordings is to sample from the same neuron over days and weeks. However, this goal has been difficult to achieve for large populations of neurons. Steinmetz et al. describe the development and testing of Neuropixels 2.0. This new electrophysiological recording tool is a miniaturized, high-density probe for both acute and long-term experiments combined with sophisticated software algorithms for fully automatic post hoc computational stabilization. The technique also provides a strategy for extending the number of recorded sites beyond the number of available recording channels. In freely moving animals, extremely large numbers of individual neurons could thus be followed and tracked with the same probe for weeks and occasionally months. Science , this issue p. eabf4588
- 23 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1635-1644
Neuropixels Data-Acquisition System: A Scalable Platform for Parallel Recording of 10 000+ Electrophysiological Signals
Although CMOS fabrication has enabled a quick evolution in the design of high-density neural probes and neural-recording chips, the scaling and miniaturization of the complete data-acquisition systems has happened at a slower pace. This is mainly due to the complexity and the many requirements that change depending on the specific experimental settings. In essence, the fundamental challenge of a neural-recording system is getting the signals describing the largest possible set of neurons out of the brain and down to data storage for analysis. This requires a complete system optimization that considers the physical, electrical, thermal and signal-processing requirements, while accounting for available technology, manufacturing constraints and budget. Here we present a scalable and open-standards-based open-source data-acquisition system capable of recording from over 10,000 channels of raw neural data simultaneously. The components and their interfaces have been optimized to ensure robustness and minimum invasiveness in small-rodent electrophysiology.
- 23 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1635-1644
Neuropixels Data-Acquisition System: A Scalable Platform for Parallel Recording of 10 000+ Electrophysiological Signals
Although CMOS fabrication has enabled a quick evolution in the design of high-density neural probes and neural-recording chips, the scaling and miniaturization of the complete data-acquisition systems has happened at a slower pace. This is mainly due to the complexity and the many requirements that change depending on the specific experimental settings. In essence, the fundamental challenge of a neural-recording system is getting the signals describing the largest possible set of neurons out of the brain and down to data storage for analysis. This requires a complete system optimization that considers the physical, electrical, thermal and signal-processing requirements, while accounting for available technology, manufacturing constraints and budget. Here we present a scalable and open-standards-based open-source data-acquisition system capable of recording from over 10,000 channels of raw neural data simultaneously. The components and their interfaces have been optimized to ensure robustness and minimum invasiveness in small-rodent electrophysiology.
- 19 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1625-1634
A Compact Quad-Shank CMOS Neural Probe With 5,120 Addressable Recording Sites and 384 Fully Differential Parallel Channels
Large-scale $in\ vivo$ electrophysiology requires tools that enable simultaneous recording of multiple brain regions at single-neuron level. This calls for the design of more compact neural probes that offer even larger arrays of addressable sites and high channel counts. With this aim, we present in this paper a quad-shank approach to integrate as many as 5,120 sites on a single probe. Compact fully-differential recording channels were designed using a single-gain-stage neural amplifier with a 14-bit ADC, achieving a mean input-referred noise of 7.44 μ $\text{V}_{\text{rms}}$ in the action-potential band and 7.65 μ $\text{V}_{\text{rms}}$ in the local-field-potential band, a mean total harmonic distortion of 0.17% at 1 kHz and a mean input-referred offset of 169 μV. The probe base incorporates 384 channels with on-chip power management, reference-voltage generation and digital control, thus achieving the highest level of integration in a neural probe and excellent channel-to-channel uniformity. Therefore, no calibration or external circuitry are required to achieve the above-mentioned performance. With a total area of $2.2 \times 8.67\text{ mm}^2$ and a power consumption of 36.5 mW, the presented probe enables full-system miniaturization for acute or chronic use in small rodents.- 19 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (6) , 1625-1634
A Compact Quad-Shank CMOS Neural Probe With 5,120 Addressable Recording Sites and 384 Fully Differential Parallel Channels
Large-scale $in\ vivo$ electrophysiology requires tools that enable simultaneous recording of multiple brain regions at single-neuron level. This calls for the design of more compact neural probes that offer even larger arrays of addressable sites and high channel counts. With this aim, we present in this paper a quad-shank approach to integrate as many as 5,120 sites on a single probe. Compact fully-differential recording channels were designed using a single-gain-stage neural amplifier with a 14-bit ADC, achieving a mean input-referred noise of 7.44 μ $\text{V}_{\text{rms}}$ in the action-potential band and 7.65 μ $\text{V}_{\text{rms}}$ in the local-field-potential band, a mean total harmonic distortion of 0.17% at 1 kHz and a mean input-referred offset of 169 μV. The probe base incorporates 384 channels with on-chip power management, reference-voltage generation and digital control, thus achieving the highest level of integration in a neural probe and excellent channel-to-channel uniformity. Therefore, no calibration or external circuitry are required to achieve the above-mentioned performance. With a total area of $2.2 \times 8.67\text{ mm}^2$ and a power consumption of 36.5 mW, the presented probe enables full-system miniaturization for acute or chronic use in small rodents.- Top Cited PapersOpen Access
Time Multiplexed Active Neural Probe with 1356 Parallel Recording Sites
We present a high electrode density and high channel count CMOS (complementary metal-oxide-semiconductor) active neural probe containing 1344 neuron sized recording pixels (20 µm × 20 µm) and 12 reference pixels (20 µm × 80 µm), densely packed on a 50 µm thick, 100 µm wide, and 8 mm long shank. The active electrodes or pixels consist of dedicated in-situ circuits for signal source amplification, which are directly located under each electrode. The probe supports the simultaneous recording of all 1356 electrodes with sufficient signal to noise ratio for typical neuroscience applications. For enhanced performance, further noise reduction can be achieved while using half of the electrodes (678). Both of these numbers considerably surpass the state-of-the art active neural probes in both electrode count and number of recording channels. The measured input referred noise in the action potential band is 12.4 µVrms, while using 678 electrodes, with just 3 µW power dissipation per pixel and 45 µW per read-out channel (including data transmission).
Top Cited PapersOpen AccessTime Multiplexed Active Neural Probe with 1356 Parallel Recording Sites
We present a high electrode density and high channel count CMOS (complementary metal-oxide-semiconductor) active neural probe containing 1344 neuron sized recording pixels (20 µm × 20 µm) and 12 reference pixels (20 µm × 80 µm), densely packed on a 50 µm thick, 100 µm wide, and 8 mm long shank. The active electrodes or pixels consist of dedicated in-situ circuits for signal source amplification, which are directly located under each electrode. The probe supports the simultaneous recording of all 1356 electrodes with sufficient signal to noise ratio for typical neuroscience applications. For enhanced performance, further noise reduction can be achieved while using half of the electrodes (678). Both of these numbers considerably surpass the state-of-the art active neural probes in both electrode count and number of recording channels. The measured input referred noise in the action potential band is 12.4 µVrms, while using 678 electrodes, with just 3 µW power dissipation per pixel and 45 µW per read-out channel (including data transmission).