Karen Dawson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Karen Dawson has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Alan O'RIordan
Precision Electrochemical Nanosensors Group University College Cork Tyndall National Institute Cork Ireland
13 shared publications Aidan J. Quinn
4 shared publicationsAmélie Wahl
3 shared publicationsColm Barrett
Tyndall National Institute, University College Cork, Dyke Parade, Cork, Ireland
2 shared publications- Damien W. M. Arrigan
Curtin University GPO Box U1987
2 shared publications - Grégoire Herzog
Université de Lorraine, CNRS, LCPME, Nancy, France
2 shared publications
Latest Publications
- Open Access
- 27 August 2015
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 4 (10) , S3053-S3058
Development of Low Cost Rapid Fabrication of Sharp Polymer Microneedles for In Vivo Glucose Biosensing Applications
New approaches to enable more effective management of diabetes mellitus, such as continuous glucose monitoring are being developed both to prevent unstable episodes of hypo or hyper glycaemia and also to provide an improved user experience. One emerging approach to realize these requirements is to fabricate a minimally invasive transdermal sensor for the direct in vivo detection of glucose in the interstitial fluid. Microneedles – sharp, microscopic structures measuring less than 1 mm in length – have been previously employed to allow painless penetration of the stratum corneum for delivery of drugs and vaccines. In this work we present, ultra sharp gold coated polymer microneedle arrays (sub micron tip radii) which are fabricated using a low cost polymer replication approach. Critical dimensions of the microneedle arrays are characterized using a combination of optical and scanning electron microscopies. Fabricated microneedle devices are characterized by cyclic voltammetry to explore functionality. The voltammetric detection of glucose is performed using ferrocene monocarboxylic acid as an oxidising mediator in the presence of glucose oxidase. The biosensor can be applied to the quantification of glucose in the physiological range (2 – 13.5 mM). The sensors demonstrate high selectivity towards glucose with negligible interference from other oxidizable species including uric acid, ascorbic acid, mannose, fructose, salicylic acid (Aspirin) and acetaminophen (Paracetamol). This demonstrates potential future use of these microneedle devices for in vivo glucose detection.
- 27 August 2015
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 4 (10) , S3053-S3058
Open AccessDevelopment of Low Cost Rapid Fabrication of Sharp Polymer Microneedles for In Vivo Glucose Biosensing Applications
New approaches to enable more effective management of diabetes mellitus, such as continuous glucose monitoring are being developed both to prevent unstable episodes of hypo or hyper glycaemia and also to provide an improved user experience. One emerging approach to realize these requirements is to fabricate a minimally invasive transdermal sensor for the direct in vivo detection of glucose in the interstitial fluid. Microneedles – sharp, microscopic structures measuring less than 1 mm in length – have been previously employed to allow painless penetration of the stratum corneum for delivery of drugs and vaccines. In this work we present, ultra sharp gold coated polymer microneedle arrays (sub micron tip radii) which are fabricated using a low cost polymer replication approach. Critical dimensions of the microneedle arrays are characterized using a combination of optical and scanning electron microscopies. Fabricated microneedle devices are characterized by cyclic voltammetry to explore functionality. The voltammetric detection of glucose is performed using ferrocene monocarboxylic acid as an oxidising mediator in the presence of glucose oxidase. The biosensor can be applied to the quantification of glucose in the physiological range (2 – 13.5 mM). The sensors demonstrate high selectivity towards glucose with negligible interference from other oxidizable species including uric acid, ascorbic acid, mannose, fructose, salicylic acid (Aspirin) and acetaminophen (Paracetamol). This demonstrates potential future use of these microneedle devices for in vivo glucose detection.
- 12 June 2014
- Published by Annual Reviews in Annual Review of Analytical Chemistry
- Vol. 7 (1) , 163-181
Electroanalysis at the Nanoscale
This article reviews the state of the art of silicon chip–based nanoelectrochemical devices for sensing applications. We first describe analyte mass transport to nanoscale electrodes and emphasize understanding the importance of mass transport for the design of nanoelectrode arrays. We then describe bottom-up and top-down approaches to nanoelectrode fabrication and integration at silicon substrates. Finally, we explore recent examples of on-chip nanoelectrodes employed as sensors and diagnostics, finishing with a brief look at future applications.
- 12 June 2014
- Published by Annual Reviews in Annual Review of Analytical Chemistry
- Vol. 7 (1) , 163-181
Electroanalysis at the Nanoscale
This article reviews the state of the art of silicon chip–based nanoelectrochemical devices for sensing applications. We first describe analyte mass transport to nanoscale electrodes and emphasize understanding the importance of mass transport for the design of nanoelectrode arrays. We then describe bottom-up and top-down approaches to nanoelectrode fabrication and integration at silicon substrates. Finally, we explore recent examples of on-chip nanoelectrodes employed as sensors and diagnostics, finishing with a brief look at future applications.
- 1 January 2014
- Published by Elsevier in Electrochimica Acta
- Vol. 115, 239-246
Fully integrated on-chip nano-electrochemical devices for electroanalytical applications
- 1 January 2014
- Published by Elsevier in Electrochimica Acta
- Vol. 115, 239-246
Fully integrated on-chip nano-electrochemical devices for electroanalytical applications
- 21 June 2013
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 164, 283-293
Highly sensitive detection of nitroaromatic explosives at discrete nanowire arrays
We show a photolithography technique that permits gold nanowire array electrodes to be routinely fabricated at reasonable cost. Nanowire electrode arrays offer the potential for enhancements in electroanalysis such as increased signal-to-noise ratio and increased sensitivity while also allowing quantitative detection at much lower concentrations. We explore application of nanowire array electrodes to the detection of different nitroaromatic species. Characteristic reduction peaks of nitro groups are not observed at nanowire array electrodes using sweep voltammetric methods. By contrast, clear and well-defined reduction peaks are resolved using potential step square wave voltammetry. A Principle Component Analysis technique is employed to discriminate between nitroaromatic species including structural isomers of DNT. The analysis indicates that all compounds are successfully discriminated by unsupervised cluster analysis. Finally, the magnitude of the reduction peak at −671 mV for different concentrations of TNT exhibited excellent linearity with increasing concentrations enabling sub-150 ng mL−1 limits of detection.
- 21 June 2013
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 164, 283-293
Highly sensitive detection of nitroaromatic explosives at discrete nanowire arrays
We show a photolithography technique that permits gold nanowire array electrodes to be routinely fabricated at reasonable cost. Nanowire electrode arrays offer the potential for enhancements in electroanalysis such as increased signal-to-noise ratio and increased sensitivity while also allowing quantitative detection at much lower concentrations. We explore application of nanowire array electrodes to the detection of different nitroaromatic species. Characteristic reduction peaks of nitro groups are not observed at nanowire array electrodes using sweep voltammetric methods. By contrast, clear and well-defined reduction peaks are resolved using potential step square wave voltammetry. A Principle Component Analysis technique is employed to discriminate between nitroaromatic species including structural isomers of DNT. The analysis indicates that all compounds are successfully discriminated by unsupervised cluster analysis. Finally, the magnitude of the reduction peak at −671 mV for different concentrations of TNT exhibited excellent linearity with increasing concentrations enabling sub-150 ng mL−1 limits of detection.
- 15 April 2013
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 164, 377-390
Gold nanowire electrodes in array: simulation study and experiments
Recent developments in nanofabrication have enabled fabrication of robust and reproducible nanoelectrodes with enhanced performance, when compared to microelectrodes. A hybrid electron beam/photolithography technique is shown that permits discrete gold nanowire electrode arrays to be routinely fabricated at reasonable cost. Fabricated devices include twelve gold nanowire working electrode arrays, an on-chip gold counter electrode and an on-chip platinum pseudo reference electrode. Using potential sweep techniques, when diffusionally independent, these nanowires exhibit measurable currents in the nanoAmpere regime and display steady-state voltammograms even at very high scan rates (5000 mV s−1) indicative of fast analyte mass transport to the electrode. Nanowire electrode arrays offer the potential for enhancements in electroanalysis including increased signal to noise ratio and increased sensitivity while also allowing quantitative detection at much lower concentrations. However, to achieve this goal a full understanding of the diffusion profiles existing at nanowire arrays is required. To this end, we simulate the effects of altering inter-electrode separations on analyte diffusion for a range of scan rates at nanowire electrode arrays, and perform the corresponding experiments. We show that arrays with diffusionally independent concentration profiles demonstrate superior electrochemical performance compared to arrays with overlapping diffusion profiles when employing sweep voltammetric techniques. By contrast, we show that arrays with diffusionally overlapping profiles exhibit enhanced performance when employing step voltammetric techniques.
- 15 April 2013
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 164, 377-390
Gold nanowire electrodes in array: simulation study and experiments
Recent developments in nanofabrication have enabled fabrication of robust and reproducible nanoelectrodes with enhanced performance, when compared to microelectrodes. A hybrid electron beam/photolithography technique is shown that permits discrete gold nanowire electrode arrays to be routinely fabricated at reasonable cost. Fabricated devices include twelve gold nanowire working electrode arrays, an on-chip gold counter electrode and an on-chip platinum pseudo reference electrode. Using potential sweep techniques, when diffusionally independent, these nanowires exhibit measurable currents in the nanoAmpere regime and display steady-state voltammograms even at very high scan rates (5000 mV s−1) indicative of fast analyte mass transport to the electrode. Nanowire electrode arrays offer the potential for enhancements in electroanalysis including increased signal to noise ratio and increased sensitivity while also allowing quantitative detection at much lower concentrations. However, to achieve this goal a full understanding of the diffusion profiles existing at nanowire arrays is required. To this end, we simulate the effects of altering inter-electrode separations on analyte diffusion for a range of scan rates at nanowire electrode arrays, and perform the corresponding experiments. We show that arrays with diffusionally independent concentration profiles demonstrate superior electrochemical performance compared to arrays with overlapping diffusion profiles when employing sweep voltammetric techniques. By contrast, we show that arrays with diffusionally overlapping profiles exhibit enhanced performance when employing step voltammetric techniques.
- 4 October 2012
- Published by Elsevier in Electrochimica Acta
- Vol. 101, 169-176
Electroanalysis at discrete arrays of gold nanowire electrodes
- 4 October 2012
- Published by Elsevier in Electrochimica Acta
- Vol. 101, 169-176
Electroanalysis at discrete arrays of gold nanowire electrodes
- 1 June 2012
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 116 (27) , 14665-14673
Electroanalysis at Single Gold Nanowire Electrodes
- 1 June 2012
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 116 (27) , 14665-14673
Electroanalysis at Single Gold Nanowire Electrodes
- 12 September 2011
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry
- Vol. 21 (40) , 15995-16000
Multi-colour emission from dye doped polymeric nanotubes by host–guest energy transfer
Emission chromaticity tuning in polymeric nanotubes was achieved by transfer of excitation energy from a polymer host matrix poly(N-vinylcarbazole) (PVK) to incorporated luminescent chromophore guests (Coumarin 6 and Nile red). Nanotubes were synthesized in densely packed arrays by solution assisted template wetting. Un-doped PVK tubes displayed blue luminescence while Coumarin 6 and Nile red doped tubes exhibited characteristic green and red luminescence with minimal PVK emission, confirming effective host–guest energy transfer. The emission spectral data of single nanotubes, and indicated that, by varying the type and relative concentrations of the dopant dyes, nanotube emission could be tuned from the blue, through green and yellow, to the red and, ultimately, to white, while maintaining excellent color purity.
- 12 September 2011
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry
- Vol. 21 (40) , 15995-16000
Multi-colour emission from dye doped polymeric nanotubes by host–guest energy transfer
Emission chromaticity tuning in polymeric nanotubes was achieved by transfer of excitation energy from a polymer host matrix poly(N-vinylcarbazole) (PVK) to incorporated luminescent chromophore guests (Coumarin 6 and Nile red). Nanotubes were synthesized in densely packed arrays by solution assisted template wetting. Un-doped PVK tubes displayed blue luminescence while Coumarin 6 and Nile red doped tubes exhibited characteristic green and red luminescence with minimal PVK emission, confirming effective host–guest energy transfer. The emission spectral data of single nanotubes, and indicated that, by varying the type and relative concentrations of the dopant dyes, nanotube emission could be tuned from the blue, through green and yellow, to the red and, ultimately, to white, while maintaining excellent color purity.
- 12 September 2011
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 136 (21) , 4507-4513
Single on-chip gold nanowires for electrochemical biosensing of glucose
The development of glucose diagnostic devices with low detection limits is of key importance in diabetes-related research. New highly sensitive sensors are required for non-invasive detection of glucose in bodily fluids, other than blood, and an electrochemical sensor based on a single gold nanowire for rapid, reliable and quantitative detection of low glucose concentrations (10 μM–1 mM), is presented in this paper. Single gold nanowire devices are fabricated at silicon chip substrates using a hybrid electron beam – photolithography approach. Critical dimensions of the nanowires are characterised using a combination of scanning electron and atomic force microscopies. Fabricated nanowire devices are characterised by direct electrical probing and cyclic voltammetry to explore functionality. The voltammetric detection of glucose was performed using ferrocene monocarboxylic acid as an oxidising mediator in the presence of glucose oxidase. The biosensor can be applied to the quantification of glucose in the range of 10 μM–100 mM, with an extremely high sensitivity of 7.2 mA mM−1 cm−2 and a low detection limit of 3 μM (S/N = 3). The sensor demonstrated high selectivity towards glucose with negligible interference from other oxidizable species including uric acid, ascorbic acid, mannose, fructose, salicylic acid (Aspirin) and acetaminophen (Paracetamol).
- 12 September 2011
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 136 (21) , 4507-4513
Single on-chip gold nanowires for electrochemical biosensing of glucose
The development of glucose diagnostic devices with low detection limits is of key importance in diabetes-related research. New highly sensitive sensors are required for non-invasive detection of glucose in bodily fluids, other than blood, and an electrochemical sensor based on a single gold nanowire for rapid, reliable and quantitative detection of low glucose concentrations (10 μM–1 mM), is presented in this paper. Single gold nanowire devices are fabricated at silicon chip substrates using a hybrid electron beam – photolithography approach. Critical dimensions of the nanowires are characterised using a combination of scanning electron and atomic force microscopies. Fabricated nanowire devices are characterised by direct electrical probing and cyclic voltammetry to explore functionality. The voltammetric detection of glucose was performed using ferrocene monocarboxylic acid as an oxidising mediator in the presence of glucose oxidase. The biosensor can be applied to the quantification of glucose in the range of 10 μM–100 mM, with an extremely high sensitivity of 7.2 mA mM−1 cm−2 and a low detection limit of 3 μM (S/N = 3). The sensor demonstrated high selectivity towards glucose with negligible interference from other oxidizable species including uric acid, ascorbic acid, mannose, fructose, salicylic acid (Aspirin) and acetaminophen (Paracetamol).
- 17 August 2011
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 307 (1) , 012061
Nanomolar Trace Metal Analysis of Copper at Gold Microband Arrays
This paper describes the fabrication and electrochemical characterization of gold microband electrode arrays designated as a highly sensitive sensor for trace metal detection of copper in drinking water samples. Gold microband electrodes have been routinely fabricated by standard photolithographic methods. Electrochemical characterization were conducted in 0.1 M H2SO4 and found to display characteristic gold oxide formation and reduction peaks. The advantages of gold microband electrodes as trace metal sensors over currently used methods have been investigated by employing under potential deposition anodic stripping voltammetry (UPD-ASV) in Cu2+ nanomolar concentrations. Linear correlations were observed for increasing Cu2+ concentrations from which the concentration of an unknown sample of drinking water was estimated. The results obtained for the estimation of the unknown trace copper concentration in drinking was in good agreement with expected values.
- 17 August 2011
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 307 (1) , 012061
Nanomolar Trace Metal Analysis of Copper at Gold Microband Arrays
This paper describes the fabrication and electrochemical characterization of gold microband electrode arrays designated as a highly sensitive sensor for trace metal detection of copper in drinking water samples. Gold microband electrodes have been routinely fabricated by standard photolithographic methods. Electrochemical characterization were conducted in 0.1 M H2SO4 and found to display characteristic gold oxide formation and reduction peaks. The advantages of gold microband electrodes as trace metal sensors over currently used methods have been investigated by employing under potential deposition anodic stripping voltammetry (UPD-ASV) in Cu2+ nanomolar concentrations. Linear correlations were observed for increasing Cu2+ concentrations from which the concentration of an unknown sample of drinking water was estimated. The results obtained for the estimation of the unknown trace copper concentration in drinking was in good agreement with expected values.