Kenneth P. Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kenneth P. Smith has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- James E. Kirby
Department of Pathology, Beth Israel Deaconess Medical Center and Harvard Medical School
13 shared publications - Manuel F. Varela
Department of Biology, Eastern New Mexico University, Portales, USA
5 shared publications - Keith P. Mintz
Department of Microbiology and Molecular Genetics University of Vermont Burlington Vermont USA
4 shared publications Sanath Kumar
Department of Biology, Eastern New Mexico University, Portales, NM 88130, USA
4 shared publicationsThea Brennan-Krohn
Department of Pathology, Beth Israel Deaconess Medical Center, Boston, MA, USA
4 shared publicationsJody L. Floyd
Department of Biology, Eastern New Mexico University, Portales, USA
3 shared publications
Latest Publications
- Open Access
- 23 July 2020
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 58 (8)
Large-Scale, In-House Production of Viral Transport Media To Support SARS-CoV-2 PCR Testing in a Multihospital Health Care Network during the COVID-19 Pandemic
The COVID-19 pandemic has severely disrupted worldwide supplies of viral transport media (VTM) due to widespread demand for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) reverse transcription-PCR (RT-PCR) testing. In response to this ongoing shortage, we began production of VTM in-house in support of diagnostic testing in our hospital network. As our diagnostic laboratory was not equipped for reagent production, we took advantage of space and personnel that became available due to closure of the research division of our medical center.
- 23 July 2020
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 58 (8)
Open AccessLarge-Scale, In-House Production of Viral Transport Media To Support SARS-CoV-2 PCR Testing in a Multihospital Health Care Network during the COVID-19 Pandemic
The COVID-19 pandemic has severely disrupted worldwide supplies of viral transport media (VTM) due to widespread demand for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) reverse transcription-PCR (RT-PCR) testing. In response to this ongoing shortage, we began production of VTM in-house in support of diagnostic testing in our hospital network. As our diagnostic laboratory was not equipped for reagent production, we took advantage of space and personnel that became available due to closure of the research division of our medical center.
- 1 August 2018
- Published by American Society for Microbiology in Antimicrobial Agents and Chemotherapy
- Vol. 62 (8)
The Inoculum Effect in the Era of Multidrug Resistance: Minor Differences in Inoculum Have Dramatic Effect on MIC Determination
The observed MIC may depend on the number of bacteria initially inoculated into the assay. This phenomenon is termed the inoculum effect (IE) and is often most pronounced for β-lactams in strains expressing β-lactamase enzymes. The Clinical and Laboratory Standards Institute (CLSI)-recommended inoculum is 5 × 10 5 CFU ml −1 with an acceptable range of 2 × 10 5 to 8 × 10 5 CFU ml −1 . IE testing is typically performed using an inoculum 100-fold greater than the CLSI-recommended inoculum. Therefore, it remains unknown whether the IE influences MICs during testing performed according to CLSI guidelines. Here, we utilized inkjet printing technology to test the IE on cefepime, meropenem, and ceftazidime-avibactam. First, we determined that the inkjet dispense volume correlated well with the number of bacteria delivered to microwells in 2-fold ( R 2 = 0.99) or 1.1-fold ( R 2 = 0.98) serial dilutions. We then quantified the IE by dispensing orthogonal titrations of bacterial cells and antibiotics. For cefepime-resistant and susceptible dose-dependent strains, a 2-fold increase in inoculum resulted in a 1.6 log 2 -fold increase in MIC. For carbapenemase-producing strains, each 2-fold reduction in inoculum resulted in a 1.26 log 2 -fold reduction in meropenem MIC. At the lower end of the CLSI-allowable inoculum range, minor error rates of 34.8% were observed for meropenem when testing a resistant-strain set. Ceftazidime-avibactam was not subject to an appreciable IE. Our results suggest that IE is sufficiently pronounced for meropenem and cefepime in multidrug-resistant Gram-negative pathogens to affect categorical interpretations during standard laboratory testing.
- 1 August 2018
- Published by American Society for Microbiology in Antimicrobial Agents and Chemotherapy
- Vol. 62 (8)
The Inoculum Effect in the Era of Multidrug Resistance: Minor Differences in Inoculum Have Dramatic Effect on MIC Determination
The observed MIC may depend on the number of bacteria initially inoculated into the assay. This phenomenon is termed the inoculum effect (IE) and is often most pronounced for β-lactams in strains expressing β-lactamase enzymes. The Clinical and Laboratory Standards Institute (CLSI)-recommended inoculum is 5 × 10 5 CFU ml −1 with an acceptable range of 2 × 10 5 to 8 × 10 5 CFU ml −1 . IE testing is typically performed using an inoculum 100-fold greater than the CLSI-recommended inoculum. Therefore, it remains unknown whether the IE influences MICs during testing performed according to CLSI guidelines. Here, we utilized inkjet printing technology to test the IE on cefepime, meropenem, and ceftazidime-avibactam. First, we determined that the inkjet dispense volume correlated well with the number of bacteria delivered to microwells in 2-fold ( R 2 = 0.99) or 1.1-fold ( R 2 = 0.98) serial dilutions. We then quantified the IE by dispensing orthogonal titrations of bacterial cells and antibiotics. For cefepime-resistant and susceptible dose-dependent strains, a 2-fold increase in inoculum resulted in a 1.6 log 2 -fold increase in MIC. For carbapenemase-producing strains, each 2-fold reduction in inoculum resulted in a 1.26 log 2 -fold reduction in meropenem MIC. At the lower end of the CLSI-allowable inoculum range, minor error rates of 34.8% were observed for meropenem when testing a resistant-strain set. Ceftazidime-avibactam was not subject to an appreciable IE. Our results suggest that IE is sufficiently pronounced for meropenem and cefepime in multidrug-resistant Gram-negative pathogens to affect categorical interpretations during standard laboratory testing.
- 1 April 2018
- Published by American Society for Microbiology in Antimicrobial Agents and Chemotherapy
- Vol. 62 (4)
Efficacy of Apramycin against Multidrug-Resistant Acinetobacter baumannii in the Murine Neutropenic Thigh Model
Apramycin, an aminocyclitol aminoglycoside, was rapidly bactericidal against Acinetobacter baumannii . In a neutropenic murine thigh infection model, treatment-associated A. baumannii CFU reductions of >4 log 10 per thigh were observed for all exposures for which area under the curve (AUC)/MIC ratio was >50 and maximum concentration of drug in serum ( C max )/MIC was ≈10 or higher. Based on these findings, we suggest that apramycin deserves further preclinical exploration as a repurposed therapeutic for multidrug-resistant Gram-negative pathogens, including A. baumannii .
- 1 April 2018
- Published by American Society for Microbiology in Antimicrobial Agents and Chemotherapy
- Vol. 62 (4)
Efficacy of Apramycin against Multidrug-Resistant Acinetobacter baumannii in the Murine Neutropenic Thigh Model
Apramycin, an aminocyclitol aminoglycoside, was rapidly bactericidal against Acinetobacter baumannii . In a neutropenic murine thigh infection model, treatment-associated A. baumannii CFU reductions of >4 log 10 per thigh were observed for all exposures for which area under the curve (AUC)/MIC ratio was >50 and maximum concentration of drug in serum ( C max )/MIC was ≈10 or higher. Based on these findings, we suggest that apramycin deserves further preclinical exploration as a repurposed therapeutic for multidrug-resistant Gram-negative pathogens, including A. baumannii .
- 1 March 2018
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 56 (3)
Automated Interpretation of Blood Culture Gram Stains by Use of a Deep Convolutional Neural Network
Microscopic interpretation of stained smears is one of the most operator-dependent and time-intensive activities in the clinical microbiology laboratory. Here, we investigated application of an automated image acquisition and convolutional neural network (CNN)-based approach for automated Gram stain classification. Using an automated microscopy platform, uncoverslipped slides were scanned with a 40× dry objective, generating images of sufficient resolution for interpretation. We collected 25,488 images from positive blood culture Gram stains prepared during routine clinical workup. These images were used to generate 100,213 crops containing Gram-positive cocci in clusters, Gram-positive cocci in chains/pairs, Gram-negative rods, or background (no cells). These categories were targeted for proof-of-concept development as they are associated with the majority of bloodstream infections. Our CNN model achieved a classification accuracy of 94.9% on a test set of image crops. Receiver operating characteristic (ROC) curve analysis indicated a robust ability to differentiate between categories with an area under the curve of >0.98 for each. After training and validation, we applied the classification algorithm to new images collected from 189 whole slides without human intervention. Sensitivity and specificity were 98.4% and 75.0% for Gram-positive cocci in chains and pairs, 93.2% and 97.2% for Gram-positive cocci in clusters, and 96.3% and 98.1% for Gram-negative rods. Taken together, our data support a proof of concept for a fully automated classification methodology for blood-culture Gram stains. Importantly, the algorithm was highly adept at identifying image crops with organisms and could be used to present prescreened, classified crops to technologists to accelerate smear review. This concept could potentially be extended to all Gram stain interpretive activities in the clinical laboratory.
- 1 March 2018
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 56 (3)
Automated Interpretation of Blood Culture Gram Stains by Use of a Deep Convolutional Neural Network
Microscopic interpretation of stained smears is one of the most operator-dependent and time-intensive activities in the clinical microbiology laboratory. Here, we investigated application of an automated image acquisition and convolutional neural network (CNN)-based approach for automated Gram stain classification. Using an automated microscopy platform, uncoverslipped slides were scanned with a 40× dry objective, generating images of sufficient resolution for interpretation. We collected 25,488 images from positive blood culture Gram stains prepared during routine clinical workup. These images were used to generate 100,213 crops containing Gram-positive cocci in clusters, Gram-positive cocci in chains/pairs, Gram-negative rods, or background (no cells). These categories were targeted for proof-of-concept development as they are associated with the majority of bloodstream infections. Our CNN model achieved a classification accuracy of 94.9% on a test set of image crops. Receiver operating characteristic (ROC) curve analysis indicated a robust ability to differentiate between categories with an area under the curve of >0.98 for each. After training and validation, we applied the classification algorithm to new images collected from 189 whole slides without human intervention. Sensitivity and specificity were 98.4% and 75.0% for Gram-positive cocci in chains and pairs, 93.2% and 97.2% for Gram-positive cocci in clusters, and 96.3% and 98.1% for Gram-negative rods. Taken together, our data support a proof of concept for a fully automated classification methodology for blood-culture Gram stains. Importantly, the algorithm was highly adept at identifying image crops with organisms and could be used to present prescreened, classified crops to technologists to accelerate smear review. This concept could potentially be extended to all Gram stain interpretive activities in the clinical laboratory.
- Open Access
- 1 December 2017
- Published by Elsevier in SLAS Technology
- Vol. 22 (6) , 662-674
Development of MAST: A Microscopy-Based Antimicrobial Susceptibility Testing Platform
- 1 December 2017
- Published by Elsevier in SLAS Technology
- Vol. 22 (6) , 662-674
Open AccessDevelopment of MAST: A Microscopy-Based Antimicrobial Susceptibility Testing Platform
- 1 August 2017
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 55 (8) , 2304-2308
The Poisoned Well: Enhancing the Predictive Value of Antimicrobial Susceptibility Testing in the Era of Multidrug Resistance
Antimicrobial susceptibility testing (AST) is a fundamental mission of the clinical microbiology laboratory. Reference AST methods are based on bacterial growth in antibiotic doubling dilution series, which means that any error in the reference method inherently represents at least a 2-fold difference. We describe the origins of current AST reference methodology, highlight the sources of AST variability, and propose ideas for improving AST predictive power.
- 1 August 2017
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 55 (8) , 2304-2308
The Poisoned Well: Enhancing the Predictive Value of Antimicrobial Susceptibility Testing in the Era of Multidrug Resistance
Antimicrobial susceptibility testing (AST) is a fundamental mission of the clinical microbiology laboratory. Reference AST methods are based on bacterial growth in antibiotic doubling dilution series, which means that any error in the reference method inherently represents at least a 2-fold difference. We describe the origins of current AST reference methodology, highlight the sources of AST variability, and propose ideas for improving AST predictive power.
- Open Access
- 31 July 2017
- Published by Oxford University Press (OUP) in Journal of Antimicrobial Chemotherapy
- Vol. 72 (10) , 2775-2781
Screening for synergistic activity of antimicrobial combinations against carbapenem-resistant Enterobacteriaceae using inkjet printer-based technology
Synergistic combination antimicrobial therapy may provide new options for treatment of MDR infections. However, comprehensive in vitro synergy data are limited and facile methods to perform synergy testing in a clinically actionable time frame are unavailable. To systematically investigate a broad range of antibiotic combinations for evidence of synergistic activity against a collection of carbapenem-resistant Enterobacteriaceae (CRE) isolates. We made use of an automated method for chequerboard array synergy testing based on inkjet printer technology in the HP D300 digital dispenser to test 56 pairwise antimicrobial combinations of meropenem, aztreonam, cefepime, colistin, gentamicin, levofloxacin, chloramphenicol, fosfomycin, trimethoprim/sulfamethoxazole, minocycline and rifampicin, as well as the double carbapenem combination of meropenem and ertapenem. In a screening procedure, we tested these combinations against four CRE strains and identified nine antibiotic combinations that showed potential clinically relevant synergy. In confirmatory testing using 10 CRE strains, six combinations demonstrated clinically relevant synergy with both antimicrobials at the minimum fractional inhibitory concentration (FICI-MIN) in the susceptible or intermediate range in at least one trial. These included two novel combinations: minocycline plus colistin and minocycline plus meropenem. In 80% of strains at least one combination demonstrated clinically relevant synergy, but the combinations that demonstrated synergy varied from strain to strain. This work establishes the foundation for future systematic, broad-range investigations into antibiotic synergy for CRE, emphasizes the need for individualized synergy testing and demonstrates the utility of inkjet printer-based technology for the performance of automated antimicrobial synergy assays.
- 31 July 2017
- Published by Oxford University Press (OUP) in Journal of Antimicrobial Chemotherapy
- Vol. 72 (10) , 2775-2781
Open AccessScreening for synergistic activity of antimicrobial combinations against carbapenem-resistant Enterobacteriaceae using inkjet printer-based technology
Synergistic combination antimicrobial therapy may provide new options for treatment of MDR infections. However, comprehensive in vitro synergy data are limited and facile methods to perform synergy testing in a clinically actionable time frame are unavailable. To systematically investigate a broad range of antibiotic combinations for evidence of synergistic activity against a collection of carbapenem-resistant Enterobacteriaceae (CRE) isolates. We made use of an automated method for chequerboard array synergy testing based on inkjet printer technology in the HP D300 digital dispenser to test 56 pairwise antimicrobial combinations of meropenem, aztreonam, cefepime, colistin, gentamicin, levofloxacin, chloramphenicol, fosfomycin, trimethoprim/sulfamethoxazole, minocycline and rifampicin, as well as the double carbapenem combination of meropenem and ertapenem. In a screening procedure, we tested these combinations against four CRE strains and identified nine antibiotic combinations that showed potential clinically relevant synergy. In confirmatory testing using 10 CRE strains, six combinations demonstrated clinically relevant synergy with both antimicrobials at the minimum fractional inhibitory concentration (FICI-MIN) in the susceptible or intermediate range in at least one trial. These included two novel combinations: minocycline plus colistin and minocycline plus meropenem. In 80% of strains at least one combination demonstrated clinically relevant synergy, but the combinations that demonstrated synergy varied from strain to strain. This work establishes the foundation for future systematic, broad-range investigations into antibiotic synergy for CRE, emphasizes the need for individualized synergy testing and demonstrates the utility of inkjet printer-based technology for the performance of automated antimicrobial synergy assays.
- 1 February 2017
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 55 (2) , 470-478
Improved Accuracy of Cefepime Susceptibility Testing for Extended-Spectrum-Beta-Lactamase-Producing Enterobacteriaceae with an On-Demand Digital Dispensing Method
Extended-spectrum beta-lactamase (ESBL)-producing Enterobacteriaceae generally cannot be treated with penicillins and cephalosporins. However, some later-generation cephalosporins, including cefepime, are poorly hydrolyzed by specific ESBL enzymes, and certain strains demonstrate in vitro susceptibility to these agents, potentially affording additional treatment opportunities. Moreover, the ability to adjust both the dose and dosing interval of beta-lactam agents allows the treatment of strains with elevated MICs that were formerly classified in the intermediate range. The ability to treat strains with elevated cefepime MICs is codified in new susceptible dose-dependent (SDD) breakpoints promulgated by the Clinical and Laboratory Standards Institute. In the interest of validating and implementing new cefepime SDD criteria, we evaluated the performances of Vitek 2, disk diffusion, and a MicroScan panel compared to that of reference broth microdilution (BMD) during the testing of 64 strains enriched for presumptive ESBL phenotype (based on nonsusceptibility to ceftriaxone). Surprisingly, categorical agreement with BMD was only 47.6%, 57.1%, and 44.6% for the three methods, respectively. Given these findings, we tested the performance of the HP D300 inkjet-assisted broth microdilution digital dispensing method (DDM), which was previously described by our group as an at-will testing alternative. In contrast to commercial methods, DDM results correlated well with the reference method, with 86% categorical agreement, 91.1% evaluable essential agreement, and no major or very major errors. The reproducibility and accuracy of MIC determinations were statistically equivalent to BMD. Our results provide support for the use of the DDM as a BMD equivalent methodology that will enable hospital-based clinical laboratories to support cefepime MIC-based dosing strategies.
- 1 February 2017
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 55 (2) , 470-478
Improved Accuracy of Cefepime Susceptibility Testing for Extended-Spectrum-Beta-Lactamase-Producing Enterobacteriaceae with an On-Demand Digital Dispensing Method
Extended-spectrum beta-lactamase (ESBL)-producing Enterobacteriaceae generally cannot be treated with penicillins and cephalosporins. However, some later-generation cephalosporins, including cefepime, are poorly hydrolyzed by specific ESBL enzymes, and certain strains demonstrate in vitro susceptibility to these agents, potentially affording additional treatment opportunities. Moreover, the ability to adjust both the dose and dosing interval of beta-lactam agents allows the treatment of strains with elevated MICs that were formerly classified in the intermediate range. The ability to treat strains with elevated cefepime MICs is codified in new susceptible dose-dependent (SDD) breakpoints promulgated by the Clinical and Laboratory Standards Institute. In the interest of validating and implementing new cefepime SDD criteria, we evaluated the performances of Vitek 2, disk diffusion, and a MicroScan panel compared to that of reference broth microdilution (BMD) during the testing of 64 strains enriched for presumptive ESBL phenotype (based on nonsusceptibility to ceftriaxone). Surprisingly, categorical agreement with BMD was only 47.6%, 57.1%, and 44.6% for the three methods, respectively. Given these findings, we tested the performance of the HP D300 inkjet-assisted broth microdilution digital dispensing method (DDM), which was previously described by our group as an at-will testing alternative. In contrast to commercial methods, DDM results correlated well with the reference method, with 86% categorical agreement, 91.1% evaluable essential agreement, and no major or very major errors. The reproducibility and accuracy of MIC determinations were statistically equivalent to BMD. Our results provide support for the use of the DDM as a BMD equivalent methodology that will enable hospital-based clinical laboratories to support cefepime MIC-based dosing strategies.
- 1 December 2016
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 86 (4) , 439-441
Evaluation of apramycin activity against carbapenem-resistant and -susceptible strains of Enterobacteriaceae
- 1 December 2016
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 86 (4) , 439-441
Evaluation of apramycin activity against carbapenem-resistant and -susceptible strains of Enterobacteriaceae