Lukasz Gryko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Lukasz Gryko has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Andrzej Zajac
Military University of Technology, Warsaw, Institute of Optoelectronics, Kaliskiego St., 2, 00-908, Warsaw, Poland
15 shared publications - Urszula Błaszczak
Faculty of Electrical Engineering, Bialystok University of Technology, Wiejska 45D, 15-351 Bialystok, Poland
15 shared publications - Marian Gilewski
Faculty of Electrical Engineering, Bialystok University of Technology, 45A Wiejska Street, 15-351 Bialystok, Poland
7 shared publications Justyna Szymanska
Nicolaus Copernicus Univ. in Torun (Poland)
4 shared publicationsEwa Kulesza
Bialystok Univ. of Technology (Poland)
3 shared publicationsAnna Palkowska
Bialystok Univ. of Technology (Poland)
2 shared publications
Latest Publications
- Open Access
- 3 January 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 483
Optical Degradation and Lifetime Assessment of 260–265 nm AlGaN-Based UVC LEDs Under Varying Drive-Current Regimes for Disinfection Systems
This investigation examines the optical degradation of 260 nm and 265 nm UVC LEDs subjected to varying drive current conditions, simulating real-world deployment in consumer and professional disinfection systems. The primary aim was to assess lifetime trends and degradation behaviour based exclusively on radiometric and spectral data. A total of 24 devices (12 per wavelength group) were operated for 2000 h under a broad range of thermally stabilised current levels, from low-standby to maximum-rated operation. The results demonstrated distinct current-dependent ageing characteristics, wherein, for the tested device sets and operating conditions, 260 nm LEDs exhibited faster optical power degradation than the investigated 265 nm LEDs under nominal drive conditions. Notably, a moderate current derating of approximately 20% resulted in a more than fourfold increase in L70 lifetime and over a threefold extension in the number of effective disinfection cycles. Despite a stable spectral power distribution throughout ageing, significant statistical variation in lifetime metrics (L90, L80, L70, L50) was observed even among identically operated devices, underscoring the need for population-level reliability qualification. Optical lifetime estimates based on empirical model fitting indicated that the Ruschel logarithmic function most accurately captured the long-term degradation trends for the analysed datasets. These findings provide practical guidance for the design of durable and efficient UVC LED systems within the investigated device class and operating regimes, supporting sustained germicidal performance and long-term operational reliability across diverse use cases.
- 3 January 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 483
Open AccessOptical Degradation and Lifetime Assessment of 260–265 nm AlGaN-Based UVC LEDs Under Varying Drive-Current Regimes for Disinfection Systems
This investigation examines the optical degradation of 260 nm and 265 nm UVC LEDs subjected to varying drive current conditions, simulating real-world deployment in consumer and professional disinfection systems. The primary aim was to assess lifetime trends and degradation behaviour based exclusively on radiometric and spectral data. A total of 24 devices (12 per wavelength group) were operated for 2000 h under a broad range of thermally stabilised current levels, from low-standby to maximum-rated operation. The results demonstrated distinct current-dependent ageing characteristics, wherein, for the tested device sets and operating conditions, 260 nm LEDs exhibited faster optical power degradation than the investigated 265 nm LEDs under nominal drive conditions. Notably, a moderate current derating of approximately 20% resulted in a more than fourfold increase in L70 lifetime and over a threefold extension in the number of effective disinfection cycles. Despite a stable spectral power distribution throughout ageing, significant statistical variation in lifetime metrics (L90, L80, L70, L50) was observed even among identically operated devices, underscoring the need for population-level reliability qualification. Optical lifetime estimates based on empirical model fitting indicated that the Ruschel logarithmic function most accurately captured the long-term degradation trends for the analysed datasets. These findings provide practical guidance for the design of durable and efficient UVC LED systems within the investigated device class and operating regimes, supporting sustained germicidal performance and long-term operational reliability across diverse use cases.
- Open Access
- 29 June 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (13) , 5717
High-Quality Multi-Emitter LED-Based Retrofits for Incandescent Photometric A Illuminant Reliability of R2 Evaluation
This research deals with the design problems of LED-based spectrally tunable light sources (LSTLSs). The study aims to assess the reliability of popular models for the spectral modeling of LED radiation and a typically used curve-fitting criterion (R2) in the development of high-quality multi-emitter LED retrofits for incandescent photometric illuminant. The research methodology involves modeling each LED channel using Lorentz and Gaussian functions and combining multiple channels to approximate the desired spectral power distribution (SPD). After the optimization, 20 various LED sets were designed, which allowed us to replicate the SPD of CIE illuminant A with a very high R2 value. Two sets were constructed and measured to recognize the reliability of the simulation approach. The results suggest that for planning the LSTLS for photometric applications, these models are unreliable as they do not reflect the real effect of changes in the characteristics of the components nor reveal the share of various spectral ranges. Therefore, the decisions made on these criteria may not be the best solutions in the context of specific applications.
- 29 June 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (13) , 5717
Open AccessHigh-Quality Multi-Emitter LED-Based Retrofits for Incandescent Photometric A Illuminant Reliability of R2 Evaluation
This research deals with the design problems of LED-based spectrally tunable light sources (LSTLSs). The study aims to assess the reliability of popular models for the spectral modeling of LED radiation and a typically used curve-fitting criterion (R2) in the development of high-quality multi-emitter LED retrofits for incandescent photometric illuminant. The research methodology involves modeling each LED channel using Lorentz and Gaussian functions and combining multiple channels to approximate the desired spectral power distribution (SPD). After the optimization, 20 various LED sets were designed, which allowed us to replicate the SPD of CIE illuminant A with a very high R2 value. Two sets were constructed and measured to recognize the reliability of the simulation approach. The results suggest that for planning the LSTLS for photometric applications, these models are unreliable as they do not reflect the real effect of changes in the characteristics of the components nor reveal the share of various spectral ranges. Therefore, the decisions made on these criteria may not be the best solutions in the context of specific applications.
- Open Access
- 31 December 2023
- Published by Photonics Society of Poland in Photonics Letters of Poland
- Vol. 15 (4) , 75-77
Tunable LED illumination for biological tissue imaging
The article presents the results of biological tissue imaging with a tunable broadband LED illuminator with adjustable color and correlated color temperature of white light characterized by high color rendering indices. Color imaging of tissue is the basis for diagnostic procedures in various disease states. For this reason, it is essential to optimize the illumination so that differences in tissue color are highlighted not only by improved color fidelity but also by high color contrast. Full Text: PDF References M.H. Tran, B. Fei, "Compact and ultracompact spectral imagers: technology and applications in biomedical imaging", J Biomed Opt 28, 4 (2023). CrossRef E.J.M. Baltussen, E.N.D. Kok, S.G.J. Brouwer de Koning, "Hyperspectral imaging for tissue classification, a way toward smart laparoscopic colorectal surgery", J Biomed Opt 24, 1 (2019). CrossRef N.T. Clancy, G. Jones, L. Maier-Hein, D.S. Elson, and D. Stoyanov, "Surgical spectral imaging", Med Image Anal 63, 101699 (2020). CrossRef R. Zhang, Z. Guo, Y. Chen, "A Deep Learning-Aided Remote Spectrally Tunable LED Light Source Integrated System", IEEE Trans Instrum Meas 72, 1 (2023). CrossRef P. Liu, H. Wang, Y. Zhang, "Investigation of self-adaptive LED surgical lighting based on entropy contrast enhancing method", Opt Commun 319, 133 (2014). CrossRef J. Shen, S. Chang, H. Wang, Z. Zheng, Light. "Optimising the illumination spectrum for enhancing tissue visualisation", Res. Technol. 51, 99 (2019). CrossRef K. Kameyama, T. Ohbayashi, K. Uehara, A. Koga, Y. Hata, "The Influence of Illumination Color on the Subjective Visual Recognition of Biological Specimens", Yonago Acta Med 63, 266 (2020). CrossRef H. Wang, R.H. Cuijpers, M. R. Luo, I. Heynderickx, and Z. Zheng, "Optimal illumination for local contrast enhancement based on the human visual system", J Biomed Opt 20, 015005 (2015). CrossRef J. Mundinger, K. Houser, "Adjustable correlated colour temperature for surgical lighting", Light. Res. Technol. 51, 280 (2019). CrossRef M.A. Ilișanu, F. Moldoveanu, A. Moldoveanu, "Multispectral Imaging for Skin Diseases Assessment—State of the Art and Perspectives", Sensor 23, 3888 (2023). CrossRef K.L. Hanlon, G. Wei, L. Correa-Selm, and J.M. Grichnik, "Dermoscopy and skin imaging light sources: a comparison and review of spectral power distribution and color consistency", J Biomed Opt 27, 080902 (2022). CrossRef O.V. Mamontov, A.V. Shcherbinin, R.V. Romashko, "Intraoperative Imaging of Cortical Blood Flow by Camera-Based Photoplethysmography at Green Light", Appl Sci 10, 6192 (2020). CrossRef F.J. Burgos-Fernández, T. Alterini, F. Diaz-Douton, L. Gonzales, C. Mateo, C. Mestre, J. Pujol, M.Vilaseca, "Reflectance evaluation of eye fundus structures with a visible and near-infrared multispectral camera", Biomed Opt Express 13, 3504 (2022). CrossRef D. Kapsokalyvas, N. Bruscino, "Spectral morphological analysis of skin lesions with a polarization multispectral dermoscope", Opt Express 21, 4826 (2013). CrossRef J. Yang, H. Xu, F. Zhang, Z. Wang, P. Xu, "Enhancing local color contrast by optimizing multichannel LED light sources", Opt. Eng. 57, 1 (2018). CrossRef N. Posner, A. Stefanidi, J. Hanhart, Biomed. Eng. Res. (2020). DirectLink U.J. Blaszczak, L. Gryko, A. Zajac, "Tunable white light source for medical applications", Proc. SPIE, 10445 (2017), CrossRef L. Gryko, U. J. Blaszczak, A.S. Zajac, "Colorimetric characterization of the tunable LED-based light source at the output of the homogenizing rod", Proc SPIE, 1080811 (2018). CrossRef U.J. Błaszczak, Ł. Gryko, A.S. Zając, "Characterization of multi-emitter tuneable led source for endoscopic applications", Metrol. Meas. Syst. 26, 153 (2019). CrossRef U.J. Błaszczak, M. Gilewski, Ł. Gryko, A.S. Zając, "Badanie wpływu sposobu zasilania na wybrane parametry optyczne zestawu diod elektroluminescencyjnych", Przeglad Elektrotechniczny 92, 150 (2016). CrossRef
- 31 December 2023
- Published by Photonics Society of Poland in Photonics Letters of Poland
- Vol. 15 (4) , 75-77
Open AccessTunable LED illumination for biological tissue imaging
The article presents the results of biological tissue imaging with a tunable broadband LED illuminator with adjustable color and correlated color temperature of white light characterized by high color rendering indices. Color imaging of tissue is the basis for diagnostic procedures in various disease states. For this reason, it is essential to optimize the illumination so that differences in tissue color are highlighted not only by improved color fidelity but also by high color contrast. Full Text: PDF References M.H. Tran, B. Fei, "Compact and ultracompact spectral imagers: technology and applications in biomedical imaging", J Biomed Opt 28, 4 (2023). CrossRef E.J.M. Baltussen, E.N.D. Kok, S.G.J. Brouwer de Koning, "Hyperspectral imaging for tissue classification, a way toward smart laparoscopic colorectal surgery", J Biomed Opt 24, 1 (2019). CrossRef N.T. Clancy, G. Jones, L. Maier-Hein, D.S. Elson, and D. Stoyanov, "Surgical spectral imaging", Med Image Anal 63, 101699 (2020). CrossRef R. Zhang, Z. Guo, Y. Chen, "A Deep Learning-Aided Remote Spectrally Tunable LED Light Source Integrated System", IEEE Trans Instrum Meas 72, 1 (2023). CrossRef P. Liu, H. Wang, Y. Zhang, "Investigation of self-adaptive LED surgical lighting based on entropy contrast enhancing method", Opt Commun 319, 133 (2014). CrossRef J. Shen, S. Chang, H. Wang, Z. Zheng, Light. "Optimising the illumination spectrum for enhancing tissue visualisation", Res. Technol. 51, 99 (2019). CrossRef K. Kameyama, T. Ohbayashi, K. Uehara, A. Koga, Y. Hata, "The Influence of Illumination Color on the Subjective Visual Recognition of Biological Specimens", Yonago Acta Med 63, 266 (2020). CrossRef H. Wang, R.H. Cuijpers, M. R. Luo, I. Heynderickx, and Z. Zheng, "Optimal illumination for local contrast enhancement based on the human visual system", J Biomed Opt 20, 015005 (2015). CrossRef J. Mundinger, K. Houser, "Adjustable correlated colour temperature for surgical lighting", Light. Res. Technol. 51, 280 (2019). CrossRef M.A. Ilișanu, F. Moldoveanu, A. Moldoveanu, "Multispectral Imaging for Skin Diseases Assessment—State of the Art and Perspectives", Sensor 23, 3888 (2023). CrossRef K.L. Hanlon, G. Wei, L. Correa-Selm, and J.M. Grichnik, "Dermoscopy and skin imaging light sources: a comparison and review of spectral power distribution and color consistency", J Biomed Opt 27, 080902 (2022). CrossRef O.V. Mamontov, A.V. Shcherbinin, R.V. Romashko, "Intraoperative Imaging of Cortical Blood Flow by Camera-Based Photoplethysmography at Green Light", Appl Sci 10, 6192 (2020). CrossRef F.J. Burgos-Fernández, T. Alterini, F. Diaz-Douton, L. Gonzales, C. Mateo, C. Mestre, J. Pujol, M.Vilaseca, "Reflectance evaluation of eye fundus structures with a visible and near-infrared multispectral camera", Biomed Opt Express 13, 3504 (2022). CrossRef D. Kapsokalyvas, N. Bruscino, "Spectral morphological analysis of skin lesions with a polarization multispectral dermoscope", Opt Express 21, 4826 (2013). CrossRef J. Yang, H. Xu, F. Zhang, Z. Wang, P. Xu, "Enhancing local color contrast by optimizing multichannel LED light sources", Opt. Eng. 57, 1 (2018). CrossRef N. Posner, A. Stefanidi, J. Hanhart, Biomed. Eng. Res. (2020). DirectLink U.J. Blaszczak, L. Gryko, A. Zajac, "Tunable white light source for medical applications", Proc. SPIE, 10445 (2017), CrossRef L. Gryko, U. J. Blaszczak, A.S. Zajac, "Colorimetric characterization of the tunable LED-based light source at the output of the homogenizing rod", Proc SPIE, 1080811 (2018). CrossRef U.J. Błaszczak, Ł. Gryko, A.S. Zając, "Characterization of multi-emitter tuneable led source for endoscopic applications", Metrol. Meas. Syst. 26, 153 (2019). CrossRef U.J. Błaszczak, M. Gilewski, Ł. Gryko, A.S. Zając, "Badanie wpływu sposobu zasilania na wybrane parametry optyczne zestawu diod elektroluminescencyjnych", Przeglad Elektrotechniczny 92, 150 (2016). CrossRef
- Open Access
- 30 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (23) , 12886
The Impact of Time and Temperature of Operation on the Characteristics of High-Power UVC LEDs and Their Disinfection Efficiency
Disinfection and sterilization based on the use of UVC radiation are the key technologies ensuring health and safety. Their reliability depends on assuring the effectiveness of the performed process. In recent years, the rapid development of LED sources emitting high-power radiation in the UVC range has been observed, and there is a growing interest in using them in a variety of smart applications, mostly because they are easy to control, do not contain hazardous substances, and there are prospects to increase their energy efficiency. However, the literature does not provide enough knowledge on the reliability of disinfection with high-power UVC LEDs. This research aims to present a methodology of linking the performance characteristics with assessing the forecasted changes in the disinfection efficiency of exemplary UVC high-power LEDs caused by thermal and temporal changes in their characteristics. Based on the performed degradation test, the impact of the temperature and time of operation of the high-power UVC LEDs on the effectiveness of disinfection was evaluated, and the required disinfection times for exemplary pathogens were calculated. The results reveal a strong influence of the time of operation of high-power UVC LEDs on the disinfection reliability caused by the degradation of their optical power but with a low significance of wavelength shift.
- 30 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (23) , 12886
Open AccessThe Impact of Time and Temperature of Operation on the Characteristics of High-Power UVC LEDs and Their Disinfection Efficiency
Disinfection and sterilization based on the use of UVC radiation are the key technologies ensuring health and safety. Their reliability depends on assuring the effectiveness of the performed process. In recent years, the rapid development of LED sources emitting high-power radiation in the UVC range has been observed, and there is a growing interest in using them in a variety of smart applications, mostly because they are easy to control, do not contain hazardous substances, and there are prospects to increase their energy efficiency. However, the literature does not provide enough knowledge on the reliability of disinfection with high-power UVC LEDs. This research aims to present a methodology of linking the performance characteristics with assessing the forecasted changes in the disinfection efficiency of exemplary UVC high-power LEDs caused by thermal and temporal changes in their characteristics. Based on the performed degradation test, the impact of the temperature and time of operation of the high-power UVC LEDs on the effectiveness of disinfection was evaluated, and the required disinfection times for exemplary pathogens were calculated. The results reveal a strong influence of the time of operation of high-power UVC LEDs on the disinfection reliability caused by the degradation of their optical power but with a low significance of wavelength shift.
- Open Access
Degradation- and Thermal-Related Changes in Selected Electro-Optical Parameters of High-Power 270–280 nm LEDs
Recently, the rapid development of LED sources emitting high-power radiation in the UVC range has been observed, and there is a growing interest in using these LED sources in practical solutions. The innovative constructions of disinfection and sterilization devices depend on the effectiveness and reliability of UVC radiation sources. At the same time, the literature reports that deep experimental analysis of degradation of high-power LEDs is limited. The aim of this research is to contribute to existing knowledge through a comparative assessment of the changes in optical power, spectral power distribution, and forward voltage drop in time and temperature of exemplary high-power UVC LEDs. For this purpose, a controlled 1500 h degradation of six different high-power UVC LEDs was performed, based on which we determined their expected lifetimes L70, L80, and L90. According to our results, the L80 varies from 180 h to 1500 h. Stronger degradation of optical power was observed with lower current. No significant impact on the spectral parameters was observed. The results also indicate the low influence of temperature on the voltage (λ and full width at half maximum ΔFWHM < 0.025 nm/°C).
Open AccessDegradation- and Thermal-Related Changes in Selected Electro-Optical Parameters of High-Power 270–280 nm LEDs
Recently, the rapid development of LED sources emitting high-power radiation in the UVC range has been observed, and there is a growing interest in using these LED sources in practical solutions. The innovative constructions of disinfection and sterilization devices depend on the effectiveness and reliability of UVC radiation sources. At the same time, the literature reports that deep experimental analysis of degradation of high-power LEDs is limited. The aim of this research is to contribute to existing knowledge through a comparative assessment of the changes in optical power, spectral power distribution, and forward voltage drop in time and temperature of exemplary high-power UVC LEDs. For this purpose, a controlled 1500 h degradation of six different high-power UVC LEDs was performed, based on which we determined their expected lifetimes L70, L80, and L90. According to our results, the L80 varies from 180 h to 1500 h. Stronger degradation of optical power was observed with lower current. No significant impact on the spectral parameters was observed. The results also indicate the low influence of temperature on the voltage (λ and full width at half maximum ΔFWHM < 0.025 nm/°C).
- Open Access
- 1 September 2020
- Published by Elsevier in Solar Energy
- Vol. 208, 830-858
Matching CIE illuminants to measured spectral power distributions: A method to evaluate non-visual potential of daylight in two European cities
- 1 September 2020
- Published by Elsevier in Solar Energy
- Vol. 208, 830-858
Open AccessMatching CIE illuminants to measured spectral power distributions: A method to evaluate non-visual potential of daylight in two European cities
- 6 November 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7169, 187
Visualisation of biological tissues with the use of LED source illumination
Development of high power light-emitting diodes has brought new possibilities in many applications, especially in terms of flexible adjustment of light spectra. This feature is very useful in construction of many devices, for example for medical diagnosis – imaging of biological objects. In the paper we describe exemplary results of imaging of biological samples with the use of the tunable LED-based source. The source is composed of 13 high power light-emitting diodes (11 monochrome and 2 phosphor converted LEDs) covering visible region. The system allows to illuminate the object with quasi-monochromatic light (monochrome LEDs) as well as white light with the possibility of adjusting the color temperature in the range of 2700-6500K. To obtain object images miniature color camera was used which allowed us to test the operation of the source in a model of endoscope. Recorded images were processed in Matlab in order to analyze the RGB channels and test future possibility of automatic detection of selected areas of the tissue.
- 6 November 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7169, 187
Visualisation of biological tissues with the use of LED source illumination
Development of high power light-emitting diodes has brought new possibilities in many applications, especially in terms of flexible adjustment of light spectra. This feature is very useful in construction of many devices, for example for medical diagnosis – imaging of biological objects. In the paper we describe exemplary results of imaging of biological samples with the use of the tunable LED-based source. The source is composed of 13 high power light-emitting diodes (11 monochrome and 2 phosphor converted LEDs) covering visible region. The system allows to illuminate the object with quasi-monochromatic light (monochrome LEDs) as well as white light with the possibility of adjusting the color temperature in the range of 2700-6500K. To obtain object images miniature color camera was used which allowed us to test the operation of the source in a model of endoscope. Recorded images were processed in Matlab in order to analyze the RGB channels and test future possibility of automatic detection of selected areas of the tissue.
- 15 January 2019
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 26 (1) , 153-169
Characterization of multi-emitter tuneable led source for endoscopic applications
- 15 January 2019
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 26 (1) , 153-169
Characterization of multi-emitter tuneable led source for endoscopic applications
- 1 October 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10808, 179
Colorimetric characterization of the tunable LED-based light source at the output of the homogenizing rod
The best method to obtain uniform spectral characteristic for multi-emitter sources is to use integrating sphere as mixing element. In each point of exit window of such sphere the luminance and spectral characteristic are uniform. However price of integrating spheres are disadvantageous and the output power decreases dramatically with the increase their diameters. For this reason sometimes homogenizing rods are used when LEDs are used. In the paper we present the results of colorimetric characterization of low cost homogenizing rectangular-shaped rod applied in the tunable LEDbased source for endoscopic system. For each correlated color temperature (CCT) value we investigated changes of spectral power distribution (SPD) on the output surface of the homogenizing rod and variation of CCT while increasing the distance from the output of the rod. Results of these measurements enable efficient lighting of the working area and proper placement of optical fibers used to guide light to difficult-access objects.
- 1 October 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10808, 179
Colorimetric characterization of the tunable LED-based light source at the output of the homogenizing rod
The best method to obtain uniform spectral characteristic for multi-emitter sources is to use integrating sphere as mixing element. In each point of exit window of such sphere the luminance and spectral characteristic are uniform. However price of integrating spheres are disadvantageous and the output power decreases dramatically with the increase their diameters. For this reason sometimes homogenizing rods are used when LEDs are used. In the paper we present the results of colorimetric characterization of low cost homogenizing rectangular-shaped rod applied in the tunable LEDbased source for endoscopic system. For each correlated color temperature (CCT) value we investigated changes of spectral power distribution (SPD) on the output surface of the homogenizing rod and variation of CCT while increasing the distance from the output of the rod. Results of these measurements enable efficient lighting of the working area and proper placement of optical fibers used to guide light to difficult-access objects.
- 3 May 2018
- Published by Springer Nature in Lasers in Medical Science
- Vol. 33 (7) , 1521-1526
Low-level laser irradiation modifies the effect of hyperglycemia on adhesion molecule levels
Endothelium plays a key role in maintaining vascular homeostasis by secreting active factors involved in many biological processes such as hemostasis, angiogenesis, and inflammation. Hyperglycemia in diabetic patients causes dysfunction of endothelial cells. Soluble fractions of adhesion molecules like sE-selectin and vascular cell adhesion molecule (sVCAM) are considered as markers of endothelial damage. The low-level laser therapy (LLLT) effectively supports the conventional treatment of vascular complications in diabetes, for example hard-to-heal wounds in patients with diabetic foot syndrome. The aim of our study was to evaluate the effect of low-energy laser at the wavelength of 635 nm (visible light) and 830 nm (infrared) on the concentration of adhesion molecules: sE-selectin and sVCAM in the supernatant of endothelial cell culture of HUVEC line. Cells were cultured under high-glucose conditions of 30 mM/L. We have found an increase in sE-selectin and sVCAM levels in the supernatant of cells cultured under hyperglycemic conditions. This fact confirms detrimental influence of hyperglycemia on vascular endothelial cell cultures. LLLT can modulate the inflammation process. It leads to a decrease in sE-selectin and sVCAM concentration in the supernatant and an increase in the number of endothelial cells cultured under hyperglycemic conditions. The influence of LLLT is greater at the wavelength of 830 nm.
- 3 May 2018
- Published by Springer Nature in Lasers in Medical Science
- Vol. 33 (7) , 1521-1526
Low-level laser irradiation modifies the effect of hyperglycemia on adhesion molecule levels
Endothelium plays a key role in maintaining vascular homeostasis by secreting active factors involved in many biological processes such as hemostasis, angiogenesis, and inflammation. Hyperglycemia in diabetic patients causes dysfunction of endothelial cells. Soluble fractions of adhesion molecules like sE-selectin and vascular cell adhesion molecule (sVCAM) are considered as markers of endothelial damage. The low-level laser therapy (LLLT) effectively supports the conventional treatment of vascular complications in diabetes, for example hard-to-heal wounds in patients with diabetic foot syndrome. The aim of our study was to evaluate the effect of low-energy laser at the wavelength of 635 nm (visible light) and 830 nm (infrared) on the concentration of adhesion molecules: sE-selectin and sVCAM in the supernatant of endothelial cell culture of HUVEC line. Cells were cultured under high-glucose conditions of 30 mM/L. We have found an increase in sE-selectin and sVCAM levels in the supernatant of cells cultured under hyperglycemic conditions. This fact confirms detrimental influence of hyperglycemia on vascular endothelial cell cultures. LLLT can modulate the inflammation process. It leads to a decrease in sE-selectin and sVCAM concentration in the supernatant and an increase in the number of endothelial cells cultured under hyperglycemic conditions. The influence of LLLT is greater at the wavelength of 830 nm.