Richard J. Connolly
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Richard J. Connolly has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
Andrew M. Hoff
Center for Molecular Delivery at USF, University of South Florida, 4202 E. Fowler Ave. ENB 118, Tampa, FL 33620, USA; Department of Electrical Engineering, University of South Florida, 4202 E. Fowler Ave. ENB 118, Tampa, FL 33620, USA
6 shared publicationsMark J. Jaroszeski
Department of Chemical and Biomedical Engineering, University of South Florida, 4202 E. Fowler Ave. ENB 118, Tampa, FL 33620, USA; Center for Molecular Delivery at USF, University of South Florida, 4202 E. Fowler Ave. ENB 118, Tampa, FL 33620, USA
6 shared publicationsRichard Gilbert
Department of Chemical and Biomedical Engineering, University of South Florida, 4202 E. Fowler Ave. ENB 118, Tampa, FL 33620, USA; Center for Molecular Delivery at USF, University of South Florida, 4202 E. Fowler Ave. ENB 118, Tampa, FL 33620, USA
3 shared publicationsTaryn Chapman
University of South Florida
3 shared publicationsAndrew Hoff
Center for Molecular Delivery, University of South Florida, Tampa, FL
2 shared publications- Andrew M. Hoff
Department of Electrical Engineering, University of South Florida, ENB 118, 4202 E. Fowler Avenue, Tampa, FL 33620, United States
2 shared publications
Latest Publications
- 1 August 2018
- Published by Elsevier in Bioelectrochemistry
- Vol. 122, 191-198
Development of an adaptive electroporation system for intratumoral plasmid DNA delivery
- 1 August 2018
- Published by Elsevier in Bioelectrochemistry
- Vol. 122, 191-198
Development of an adaptive electroporation system for intratumoral plasmid DNA delivery
- 9 March 2018
- Published by Springer Nature in Gene Therapy
- Vol. 25 (2) , 93-103
Improving therapeutic efficacy of IL-12 intratumoral gene electrotransfer through novel plasmid design and modified parameters
The use of immunomodulatory cytokines has been shown effective in regressing a wide range of tumors. However, systemic delivery of recombinant cytokines results in serious, potentially life-threatening, adverse effects. By contrast, nucleic acid transfer via electroporation (EP) is a safe and effective method of delivering plasmid-encoded cytokines to tumors. Intratumoral delivery of IL-12 plasmid DNA by electroporation (IT-pIL12-EP) produced objective response rates in Phase 2 clinical trials in metastatic melanoma. However, only 17.9% of patients receiving IT-pIL12-EP show a complete therapeutic response. Here, we sought to improve the antitumor efficacy of our clinical IT-pIL12-EP plasmid electroporation platform. We evaluated multiple plasmid designs for IL-12 expression. IL-12 expression from a plasmid incorporating a picornavirus-derived co-translational P2A site was the most effective in expressing IL-12p70. In addition, modifying the electroporation parameters improved transfection efficiency and expression of plasmid-derived IL-12p70, as well as its downstream effector IFN-γ in vivo. Finally, using a murine melanoma model that is representative of the intended target patient population, we show that combining modified electroporation conditions with the pIL12-P2A plasmid expression enhances the systemic antitumor response. These improvements to the IT-pIL12-EP platform may improve patient clinical response rates and survival when translated to clinical trials.
- 9 March 2018
- Published by Springer Nature in Gene Therapy
- Vol. 25 (2) , 93-103
Improving therapeutic efficacy of IL-12 intratumoral gene electrotransfer through novel plasmid design and modified parameters
The use of immunomodulatory cytokines has been shown effective in regressing a wide range of tumors. However, systemic delivery of recombinant cytokines results in serious, potentially life-threatening, adverse effects. By contrast, nucleic acid transfer via electroporation (EP) is a safe and effective method of delivering plasmid-encoded cytokines to tumors. Intratumoral delivery of IL-12 plasmid DNA by electroporation (IT-pIL12-EP) produced objective response rates in Phase 2 clinical trials in metastatic melanoma. However, only 17.9% of patients receiving IT-pIL12-EP show a complete therapeutic response. Here, we sought to improve the antitumor efficacy of our clinical IT-pIL12-EP plasmid electroporation platform. We evaluated multiple plasmid designs for IL-12 expression. IL-12 expression from a plasmid incorporating a picornavirus-derived co-translational P2A site was the most effective in expressing IL-12p70. In addition, modifying the electroporation parameters improved transfection efficiency and expression of plasmid-derived IL-12p70, as well as its downstream effector IFN-γ in vivo. Finally, using a murine melanoma model that is representative of the intended target patient population, we show that combining modified electroporation conditions with the pIL12-P2A plasmid expression enhances the systemic antitumor response. These improvements to the IT-pIL12-EP platform may improve patient clinical response rates and survival when translated to clinical trials.
- 24 October 2017
- Published by Taylor & Francis in Immunotherapy
- Vol. 9 (16) , 1309-1321
Melanoma Treatment with Intratumoral Electroporation of Tavokinogene Telseplasmid (pIL-12, Tavokinogene Telseplasmid)
Tumors evade detection and/or clearance by the immune system via multiple mechanisms. IL-12 is a potent immunomodulatory cytokine that plays a central role in immune priming. However, systemic delivery of IL-12 can result in life-threatening toxicity and therefore has shown limited efficacy at doses that can be safely administered. We developed an electroporation technique to produce highly localized IL-12 expression within tumors leading to regression of both treated and untreated lesions in animal models and in patients with a favorable safety profile. Furthermore, intratumoral tavokinogene telseplasmid electroporation can drive cellular immune responses, converting ‘cold’ tumors into ‘hot’ tumors. Clinical trials are ongoing to determine whether intratumoral tavokinogene telseplasmid electroporation synergizes with checkpoint blockade therapy in immunologically cold tumors predicted not to respond to PD-1 antibody monotherapy.
- 24 October 2017
- Published by Taylor & Francis in Immunotherapy
- Vol. 9 (16) , 1309-1321
Melanoma Treatment with Intratumoral Electroporation of Tavokinogene Telseplasmid (pIL-12, Tavokinogene Telseplasmid)
Tumors evade detection and/or clearance by the immune system via multiple mechanisms. IL-12 is a potent immunomodulatory cytokine that plays a central role in immune priming. However, systemic delivery of IL-12 can result in life-threatening toxicity and therefore has shown limited efficacy at doses that can be safely administered. We developed an electroporation technique to produce highly localized IL-12 expression within tumors leading to regression of both treated and untreated lesions in animal models and in patients with a favorable safety profile. Furthermore, intratumoral tavokinogene telseplasmid electroporation can drive cellular immune responses, converting ‘cold’ tumors into ‘hot’ tumors. Clinical trials are ongoing to determine whether intratumoral tavokinogene telseplasmid electroporation synergizes with checkpoint blockade therapy in immunologically cold tumors predicted not to respond to PD-1 antibody monotherapy.
- 1 June 2017
- Published by Elsevier in Bioelectrochemistry
- Vol. 115, 33-40
Impedance spectroscopy as an indicator for successful in vivo electric field mediated gene delivery in a murine model
- 1 June 2017
- Published by Elsevier in Bioelectrochemistry
- Vol. 115, 33-40
Impedance spectroscopy as an indicator for successful in vivo electric field mediated gene delivery in a murine model
- 1 January 2017
- Published by Begell House Inc. Publishers in Plasma Medicine
- Vol. 7 (3) , 261-271
Direct Current Helium Plasma for In vivo Delivery of Plasmid DNA Encoding Erythropoietin to Murine Skin
The use of electric fields in vivo to deliver DNA, called electroporation, has the potential to broadly impact vaccination and disease treatment. The evidence for this has emerged from a large number of recently completed and ongoing clinical trials. The methods for applying electric fields to tissues traditionally involve contact between metal electrodes and the tissue. In this study, we investigated the use of helium plasma as a noncontact method for electrically treating tissue in a manner that results in the uptake and expression of foreign DNA in murine skin. More specifically, our goal was to demonstrate that DNA encoding a model-secreted protein could be delivered, detected in the blood, and remain functional to produce its known biological effect. Murine erythropoietin (EPO) was the model-secreted protein. Results clearly demonstrated that an intradermal DNA injection followed by plasma treatment for 2 min resulted in elevated levels of EPO in the blood and corresponding hemoglobin increases that were statistically significant relative to DNA injection alone.
- 1 January 2017
- Published by Begell House Inc. Publishers in Plasma Medicine
- Vol. 7 (3) , 261-271
Direct Current Helium Plasma for In vivo Delivery of Plasmid DNA Encoding Erythropoietin to Murine Skin
The use of electric fields in vivo to deliver DNA, called electroporation, has the potential to broadly impact vaccination and disease treatment. The evidence for this has emerged from a large number of recently completed and ongoing clinical trials. The methods for applying electric fields to tissues traditionally involve contact between metal electrodes and the tissue. In this study, we investigated the use of helium plasma as a noncontact method for electrically treating tissue in a manner that results in the uptake and expression of foreign DNA in murine skin. More specifically, our goal was to demonstrate that DNA encoding a model-secreted protein could be delivered, detected in the blood, and remain functional to produce its known biological effect. Murine erythropoietin (EPO) was the model-secreted protein. Results clearly demonstrated that an intradermal DNA injection followed by plasma treatment for 2 min resulted in elevated levels of EPO in the blood and corresponding hemoglobin increases that were statistically significant relative to DNA injection alone.
- 1 January 2017
- Published by PHM Society in International Journal of Prognostics and Health Management
- Vol. 8 (1)
An Integrated Architecture for Corrosion Monitoring and Testing, Data mining, Modeling and Diagnostics/Prognostics
It has been established that corrosion is one of the most important factors causing deterioration and decreased performance and reliability in critical aerospace and industrial systems. Corrosion monitoring, detection, and quantification are recognized as key enabling technologies to reduce the impact of corrosion on the integrity of aircraft and industrial assets. Accurate and reliable detection of corrosion initiation and propagation, with specified false alarm rates, requires novel tools and methods, including verifiable simulation and modeling methods. This paper reports an experimental investigation of the detection and quantification of pitting corrosion on aluminum alloy panels using 3D surface metrology methods and image processing techniques. Panel surfaces were evaluated by laser microscopy and stylus-based profilometry to characterize global and local surface features. Promising imaging and texture features were extracted and compared between coated and uncoated aluminum panels at different exposure times under accelerated corrosion conditions. Image processing, information processing, and data mining techniques were utilized to evaluate the presence and extent of pitting corrosion. A new modeling framework for corrosion stages is introduced that emphasizes the representation of pitting corrosion and ultimately the crack formation process. Detection and prediction of the evolution of corrosion stages relies on data, a particle filtering method, and the corrosion propagation model. Results from these experimental studies demonstrate the efficacy of this proposed methodology.
- 1 January 2017
- Published by PHM Society in International Journal of Prognostics and Health Management
- Vol. 8 (1)
An Integrated Architecture for Corrosion Monitoring and Testing, Data mining, Modeling and Diagnostics/Prognostics
It has been established that corrosion is one of the most important factors causing deterioration and decreased performance and reliability in critical aerospace and industrial systems. Corrosion monitoring, detection, and quantification are recognized as key enabling technologies to reduce the impact of corrosion on the integrity of aircraft and industrial assets. Accurate and reliable detection of corrosion initiation and propagation, with specified false alarm rates, requires novel tools and methods, including verifiable simulation and modeling methods. This paper reports an experimental investigation of the detection and quantification of pitting corrosion on aluminum alloy panels using 3D surface metrology methods and image processing techniques. Panel surfaces were evaluated by laser microscopy and stylus-based profilometry to characterize global and local surface features. Promising imaging and texture features were extracted and compared between coated and uncoated aluminum panels at different exposure times under accelerated corrosion conditions. Image processing, information processing, and data mining techniques were utilized to evaluate the presence and extent of pitting corrosion. A new modeling framework for corrosion stages is introduced that emphasizes the representation of pitting corrosion and ultimately the crack formation process. Detection and prediction of the evolution of corrosion stages relies on data, a particle filtering method, and the corrosion propagation model. Results from these experimental studies demonstrate the efficacy of this proposed methodology.
- 1 June 2015
- Published by Elsevier in Bioelectrochemistry
- Vol. 103, 15-21
Optimization of a plasma facilitated DNA delivery method
- 1 June 2015
- Published by Elsevier in Bioelectrochemistry
- Vol. 103, 15-21
Optimization of a plasma facilitated DNA delivery method
- 30 November 2014
- Published by Springer Nature
- p. 673-685
Corrosion Detection on Buried Transmission Pipelines with Micro-Linear Polarization Resistance Sensors
- 30 November 2014
- Published by Springer Nature
- p. 673-685
Corrosion Detection on Buried Transmission Pipelines with Micro-Linear Polarization Resistance Sensors
- 30 November 2014
- Published by Springer Nature
- p. 661-671
Universal Wireless System for Bridge Health Monitoring
- 30 November 2014
- Published by Springer Nature
- p. 661-671
Universal Wireless System for Bridge Health Monitoring
- Open Access
- 29 September 2014
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 6 (1)
A Novel Linear Polarization Resistance Corrosion Sensing Methodology for Aircraft Structure
A direct method of measuring corrosion on a structure using a micro-linear polarization resistance (μLPR) sensor is presented. The new three-electrode μLPR sensor design presented in this paper improves on existing LPR sensor technology by using the structure as part of the sensor system, allowing the sensor electrodes to be made from a corrosion resistant or inert metal. This is in contrast to a two- electrode μLPR sensor where the electrodes are made from the same material as the structure. A controlled experiment, conducted using an ASTM B117 salt fog, demonstrated the three-electrode μLPR sensors have a longer lifetime and better performance when compared to the two-electrode μLPR sensors. Following this evaluation, a controlled experiment using the ASTM G85 Annex 5 standard was performed to evaluate the accuracy and precision of the three-electrode μLPR sensor when placed between lap joint specimens made from AA7075-T6. The corrosion computed from the μLPR sensors agreed with the coupon mass loss to within a 95% confidence interval. Following the experiment, the surface morphology of each lap joint was determined using laser microscopy and stylus-based profilometry to obtain local and global surface images of the test panels. Image processing, feature extraction, and selection tools were then employed to identify the corrosion mechanism (e.g. pitting, intergranular).
- 29 September 2014
- Published by PHM Society in Annual Conference of the PHM Society
- Vol. 6 (1)
Open AccessA Novel Linear Polarization Resistance Corrosion Sensing Methodology for Aircraft Structure
A direct method of measuring corrosion on a structure using a micro-linear polarization resistance (μLPR) sensor is presented. The new three-electrode μLPR sensor design presented in this paper improves on existing LPR sensor technology by using the structure as part of the sensor system, allowing the sensor electrodes to be made from a corrosion resistant or inert metal. This is in contrast to a two- electrode μLPR sensor where the electrodes are made from the same material as the structure. A controlled experiment, conducted using an ASTM B117 salt fog, demonstrated the three-electrode μLPR sensors have a longer lifetime and better performance when compared to the two-electrode μLPR sensors. Following this evaluation, a controlled experiment using the ASTM G85 Annex 5 standard was performed to evaluate the accuracy and precision of the three-electrode μLPR sensor when placed between lap joint specimens made from AA7075-T6. The corrosion computed from the μLPR sensors agreed with the coupon mass loss to within a 95% confidence interval. Following the experiment, the surface morphology of each lap joint was determined using laser microscopy and stylus-based profilometry to obtain local and global surface images of the test panels. Image processing, feature extraction, and selection tools were then employed to identify the corrosion mechanism (e.g. pitting, intergranular).