Kazunaga Ueda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kazunaga Ueda has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Toshiyuki Hayashi
National Metrology Institute of Japan (NMIJ), AIST
10 shared publications - Atsuhiro Nishino
National Metrology Institute of Japan, AIST
7 shared publications - Koji Ogushi
National Metrology Institute of Japan, AIST, Tsukuba, Japan
6 shared publications - Shigeki Mizushima
National Metrology Institute of Japan/National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan
5 shared publications Yoshihisa Katase
National Metrology Institute of Japan (NMIJ), AIST, 1-1-1 Central 3, Umezono, Tsukuba, Ibaraki 305-8563, Japan
5 shared publicationsYukio Yamaguchi
National Metrology Institute of Japan (NMIJ), AIST, 1-1-1 Central 3, Umezono, Tsukuba, Ibaraki 305-8563, Japan
4 shared publications
Latest Publications
- 1 January 2018
- Published by Elsevier in Measurement
- Vol. 114, 203-207
Miniaturization of a 50 N tuning-fork type force transducer by adopting a simplified Roberval mechanism
- 1 January 2018
- Published by Elsevier in Measurement
- Vol. 114, 203-207
Miniaturization of a 50 N tuning-fork type force transducer by adopting a simplified Roberval mechanism
- 1 January 2017
- Published by Elsevier in Measurement
- Vol. 95, 260-265
Remaining differences among precision strain-gauge amplifiers for force transducers after compensation with reference to a common bridge calibration unit
- 1 January 2017
- Published by Elsevier in Measurement
- Vol. 95, 260-265
Remaining differences among precision strain-gauge amplifiers for force transducers after compensation with reference to a common bridge calibration unit
- 1 January 2017
- Published by Elsevier in Measurement
- Vol. 95, 418-423
Development of a high-accuracy 500 kg mass comparator for improved weight calibration capability
- 1 January 2017
- Published by Elsevier in Measurement
- Vol. 95, 418-423
Development of a high-accuracy 500 kg mass comparator for improved weight calibration capability
- 20 December 2016
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 28 (2) , 025005
Design of a new torque standard machine based on a torque generation method using electromagnetic force
To allow the application of torque standards in various industries, we have been developing torque standard machines based on a lever deadweight system, i.e. a torque generation method using gravity. However, this method is not suitable for expanding the low end of the torque range, because of the limitations to the sizes of the weights and moment arms. In this study, the working principle of the torque generation method using an electromagnetic force was investigated by referring to watt balance experiments used for the redefinition of the kilogram. Applying this principle to a rotating coordinate system, an electromagnetic force type torque standard machine was designed and prototyped. It was experimentally demonstrated that SI-traceable torque could be generated by converting electrical power to mechanical power. Thus, for the first time, SI-traceable torque was successfully realized using a method other than that based on the force of gravity.
- 20 December 2016
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 28 (2) , 025005
Design of a new torque standard machine based on a torque generation method using electromagnetic force
To allow the application of torque standards in various industries, we have been developing torque standard machines based on a lever deadweight system, i.e. a torque generation method using gravity. However, this method is not suitable for expanding the low end of the torque range, because of the limitations to the sizes of the weights and moment arms. In this study, the working principle of the torque generation method using an electromagnetic force was investigated by referring to watt balance experiments used for the redefinition of the kilogram. Applying this principle to a rotating coordinate system, an electromagnetic force type torque standard machine was designed and prototyped. It was experimentally demonstrated that SI-traceable torque could be generated by converting electrical power to mechanical power. Thus, for the first time, SI-traceable torque was successfully realized using a method other than that based on the force of gravity.
- 21 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 768-773
Experimental verification of the evaluation method of creep uncertainty from reversibility error prescribed in ISO 376:2011
ISO 376:2011 prescribes two ways of evaluating creep uncertainty in calibrations of force proving instruments: (a) one is to evaluate it from the relative creep error and (b) the other from the reversibility error. The reversibility error is a function of calibration forces, while the creep error is one single value and is not depend on the calibration forces, because the creep test is performed only once during the calibration procedure and the test result is applicable to all of the calibration forces. When the creep uncertainty is simply calculated from the reversibility error as a function of calibration forces, the creep uncertainty becomes zero at the maximum calibration force even though creep phenomenon surely appears at that force in practice. The authors proposed to revise uncertainty estimation method in ISO 376:2011 that the relative creep uncertainty calculated from the reversibility error should be uniform over the calibration range and be calculated from the maximum reversibility error expressed in terms of deflection. This report gives an experimental verification of the authors' proposition.
- 21 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 768-773
Experimental verification of the evaluation method of creep uncertainty from reversibility error prescribed in ISO 376:2011
ISO 376:2011 prescribes two ways of evaluating creep uncertainty in calibrations of force proving instruments: (a) one is to evaluate it from the relative creep error and (b) the other from the reversibility error. The reversibility error is a function of calibration forces, while the creep error is one single value and is not depend on the calibration forces, because the creep test is performed only once during the calibration procedure and the test result is applicable to all of the calibration forces. When the creep uncertainty is simply calculated from the reversibility error as a function of calibration forces, the creep uncertainty becomes zero at the maximum calibration force even though creep phenomenon surely appears at that force in practice. The authors proposed to revise uncertainty estimation method in ISO 376:2011 that the relative creep uncertainty calculated from the reversibility error should be uniform over the calibration range and be calculated from the maximum reversibility error expressed in terms of deflection. This report gives an experimental verification of the authors' proposition.
- 1 September 2016
- Published by Elsevier in Measurement
- Vol. 91, 377-384
Ambient pressure compensation for hermetically sealed force transducers
- 1 September 2016
- Published by Elsevier in Measurement
- Vol. 91, 377-384
Ambient pressure compensation for hermetically sealed force transducers
- 1 January 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (1A) , 07020
Report on the APMP.M.F-S1 supplementary comparison for 2 MN force
This document describes the comparison scheme and reports the results of the APMP.M.F-S1 supplementary comparison for 2 MN Force, in which two force transducers of 2 MN capacity were used. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (1A) , 07020
Report on the APMP.M.F-S1 supplementary comparison for 2 MN force
This document describes the comparison scheme and reports the results of the APMP.M.F-S1 supplementary comparison for 2 MN Force, in which two force transducers of 2 MN capacity were used. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 16 June 2015
- Published by IOP Publishing in Metrologia
- Vol. 52 (4) , 522-527
Determination of the amount of physical adsorption of water vapour on platinum–iridium surfaces
This paper presents the measurement of the physical adsorption of water vapour on platinum–iridium surfaces using a vacuum mass comparator. This value is of importance for redefining the kilogram, which will be realized under vacuum in the near future. Mirror-polished artefacts, consisting of a reference artefact and a test artefact, were manufactured for this experiment. The surface area difference between the reference and test artefacts was 226.2 cm 2 . This surface area difference was approximately 3.2 times the geometric surface area of the prototype of the kilogram made of platinum–iridium (71.7 cm 2 ). The measurement results indicate that the amount of physical adsorption at a relative humidity of 50% is 0.0129 μg cm , with a standard uncertainty of 0.0016 μg cm . This value is 0.03 to 0.16 times that observed in other studies.
- 16 June 2015
- Published by IOP Publishing in Metrologia
- Vol. 52 (4) , 522-527
Determination of the amount of physical adsorption of water vapour on platinum–iridium surfaces
This paper presents the measurement of the physical adsorption of water vapour on platinum–iridium surfaces using a vacuum mass comparator. This value is of importance for redefining the kilogram, which will be realized under vacuum in the near future. Mirror-polished artefacts, consisting of a reference artefact and a test artefact, were manufactured for this experiment. The surface area difference between the reference and test artefacts was 226.2 cm 2 . This surface area difference was approximately 3.2 times the geometric surface area of the prototype of the kilogram made of platinum–iridium (71.7 cm 2 ). The measurement results indicate that the amount of physical adsorption at a relative humidity of 50% is 0.0129 μg cm , with a standard uncertainty of 0.0016 μg cm . This value is 0.03 to 0.16 times that observed in other studies.
- 1 February 2015
- Published by Elsevier in Measurement
- Vol. 61, 1-8
Calibration of reference torque wrenches using a 10Nm deadweight torque standard machine
- 1 February 2015
- Published by Elsevier in Measurement
- Vol. 61, 1-8
Calibration of reference torque wrenches using a 10Nm deadweight torque standard machine