Vahit Çorumlu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vahit Çorumlu has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Ahmet Ozsoy
Isparta University of Applied Sciences
4 shared publications M. Arı
Erciyes University
3 shared publications- Murat Ozturk
Isparta University of Applied Sciences
3 shared publications - İsmail Ermiş
Sinop University
3 shared publications A. Çetin
Department of Physics, Faculty of Art and Science, Manisa Celal Bayar University
2 shared publications- Barbaros Çetin
Bilkent University
2 shared publications
Latest Publications
- 24 September 2026
- Published by Taylor & Francis in Heat Transfer Engineering
- p. 1-10
Pseudo-3D Modeling of Grooved Heat Pipes with Arbitrary Groove Geometries
- 24 September 2026
- Published by Taylor & Francis in Heat Transfer Engineering
- p. 1-10
Pseudo-3D Modeling of Grooved Heat Pipes with Arbitrary Groove Geometries
- Open Access
- 26 June 2026
- Published by Elsevier in SSRN Electronic Journal
Experimental Assessment of Gravity- and Capillary-Driven Cylindrical Heat Pipes for Thermal Management of Li-ion Batteries
This study experimentally investigates the thermal performance of a capillary-drivenheat pipe (CDHP) and a gravity-driven heat pipe (GDHP) developed for cylindricallithium-ion battery thermal management. Experiments were conducted at seven fill-ing volumes ranging from 5 to 35 mL and heat inputs from 10 to 90 W. The thermalperformance was evaluated using axial temperature distributions, thermal resistance, ef-fectiveness, source-to-vapor temperature difference, and vapor-to-sink temperature differ-ence. The results showed that thermal resistance decreased and effectiveness increasedwith increasing heat input for both heat pipes. Under most operating conditions, theCDHP exhibited lower thermal resistance and higher effectiveness than the GDHP. Theoptimum filling volume was found to depend strongly on the applied heat input ratherthan remaining constant. While higher filling volumes provided superior performance atlow heat inputs, lower filling volumes became more favorable as the heat input increased.Analysis of the temperature differences revealed that the performance differences betweenthe two heat pipes were primarily associated with the source-to-vapor temperature differ-ence, whereas similar trends were observed for the vapor-to-sink temperature difference.The improved performance of the CDHP was attributed to the capillary-assisted liquidreturn provided by the groove structures, which reduced the temperature driving forcerequired for evaporation. The findings demonstrate that capillary-driven cylindrical heatpipes can enhance thermal performance and represent a promising passive cooling solutionfor lithium-ion battery thermal management applications.
- 26 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExperimental Assessment of Gravity- and Capillary-Driven Cylindrical Heat Pipes for Thermal Management of Li-ion Batteries
This study experimentally investigates the thermal performance of a capillary-drivenheat pipe (CDHP) and a gravity-driven heat pipe (GDHP) developed for cylindricallithium-ion battery thermal management. Experiments were conducted at seven fill-ing volumes ranging from 5 to 35 mL and heat inputs from 10 to 90 W. The thermalperformance was evaluated using axial temperature distributions, thermal resistance, ef-fectiveness, source-to-vapor temperature difference, and vapor-to-sink temperature differ-ence. The results showed that thermal resistance decreased and effectiveness increasedwith increasing heat input for both heat pipes. Under most operating conditions, theCDHP exhibited lower thermal resistance and higher effectiveness than the GDHP. Theoptimum filling volume was found to depend strongly on the applied heat input ratherthan remaining constant. While higher filling volumes provided superior performance atlow heat inputs, lower filling volumes became more favorable as the heat input increased.Analysis of the temperature differences revealed that the performance differences betweenthe two heat pipes were primarily associated with the source-to-vapor temperature differ-ence, whereas similar trends were observed for the vapor-to-sink temperature difference.The improved performance of the CDHP was attributed to the capillary-assisted liquidreturn provided by the groove structures, which reduced the temperature driving forcerequired for evaporation. The findings demonstrate that capillary-driven cylindrical heatpipes can enhance thermal performance and represent a promising passive cooling solutionfor lithium-ion battery thermal management applications.
- 30 September 2024
- Published by Celal Bayar University Journal of Science in Celal Bayar Üniversitesi Fen Bilimleri Dergisi
- Vol. 20 (3) , 91-99
The Thermal Performance of The Plate-fin Heat Sink under Natural Convection at Different Power Levels and Ambient Temperatures
The thermal performance of a flat heat sink and a plate-fin heat sink was experimentally compared under natural convection conditions at thermal powers of 16.5 W and 33 W and ambient temperatures of 30°C and 40°C. For the same heating powers, surface and junction temperatures increased as the ambient temperature rose from 30°C to 40°C, but the increase was not as much as the ambient temperature change. For the flat heat sink, the increase in junction temperature was 5°C at 16.5 W and 6.68°C at 33 W. For the plate-fin heat sink, the increase in junction temperature was 3.55°C at 16.5 W and 4.47°C at 33 W. The increase in surface temperature for the flat heat sink was 5.35°C at 16.5 W and 5.91°C at 33 W, while for the plate-fin heat sink, the surface temperature increase was 4.76°C at 16.5 W and 2.22°C at 33 W. The thermal resistance of the flat heat sink was around 4 K/W, while for the plate-fin heat sink, it ranged between 2-2.5 K/W, providing approximately twice the advantage in thermal resistance for the plate-fin model compared to the flat model. Under all conditions, the Rayleigh number (Ra) significantly decreased with the increase in ambient temperature but increased with the applied thermal power. Thus, the increase in Rayleigh number with power was more pronounced in the plate-fin model, indicating a more significant effect. In the plate-fin model, the fin efficiency slightly decreased with the increase in ambient temperature, from 0.63 to 0.62 at 16.5 W and from 0.65 to 0.64 at 33 W.
- 30 September 2024
- Published by Celal Bayar University Journal of Science in Celal Bayar Üniversitesi Fen Bilimleri Dergisi
- Vol. 20 (3) , 91-99
The Thermal Performance of The Plate-fin Heat Sink under Natural Convection at Different Power Levels and Ambient Temperatures
The thermal performance of a flat heat sink and a plate-fin heat sink was experimentally compared under natural convection conditions at thermal powers of 16.5 W and 33 W and ambient temperatures of 30°C and 40°C. For the same heating powers, surface and junction temperatures increased as the ambient temperature rose from 30°C to 40°C, but the increase was not as much as the ambient temperature change. For the flat heat sink, the increase in junction temperature was 5°C at 16.5 W and 6.68°C at 33 W. For the plate-fin heat sink, the increase in junction temperature was 3.55°C at 16.5 W and 4.47°C at 33 W. The increase in surface temperature for the flat heat sink was 5.35°C at 16.5 W and 5.91°C at 33 W, while for the plate-fin heat sink, the surface temperature increase was 4.76°C at 16.5 W and 2.22°C at 33 W. The thermal resistance of the flat heat sink was around 4 K/W, while for the plate-fin heat sink, it ranged between 2-2.5 K/W, providing approximately twice the advantage in thermal resistance for the plate-fin model compared to the flat model. Under all conditions, the Rayleigh number (Ra) significantly decreased with the increase in ambient temperature but increased with the applied thermal power. Thus, the increase in Rayleigh number with power was more pronounced in the plate-fin model, indicating a more significant effect. In the plate-fin model, the fin efficiency slightly decreased with the increase in ambient temperature, from 0.63 to 0.62 at 16.5 W and from 0.65 to 0.64 at 33 W.
- Open Access
- 28 December 2023
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 11 (4) , 951-965
Plaka Kanatlı Isı Dağıtıcı Termal Performansının Deneysel Olarak Zorlanmış Konveksiyonda İncelenmesi
Bu çalışmada, plaka kanatlara (PID) sahip ısı dağıtıcının karşılaştırmalı olarak kanatsız düz ısı dağıtıcı (DID) ile termal performansı 30 ℃ ortam sıcaklığında, 33-66-99 W ısıl güçlerinde ve 2000-16000 Reynolds sayısı aralıklarında deneysel olarak incelenmiştir. Güç ortalaması dikkate alınarak plaka model düze göre yüzey sıcaklıklarında 57 ℃ ve eklem sıcaklıklarında 30.5 ℃’lik avantaj sağlamıştır. Nu sayısında plakalı model düze göre güçler için sırasıyla %79, %35 ve %38 daha yüksek olup buradan bariz olarak 33 W’ta oldukça iyi bir ısı transfer performansı sergilemiştir. Termal dirençte plakalı model düze göre güçler için sırasıyla 0.61, 0.50 ve 0.39 K/W daha düşük değerlere sahip olup güç artışıyla azalan bir eğilim göstermiştir. Plakalı modelin basınç kaybı düze göre güçler için sırasıyla 0.88, 0.75 ve 1.13 Pa yüksek gerçekleşmiştir. Basınç kaybındaki bu küçük farkların, plakalı modelin akışa paralel kanatlara sahip olmasının payı büyüktür. THP’de ise plakalı model düze göre güçler için sırasıyla %40, %10 ve %10 avantaj sağlamış ve özellikle 33 W için bariz yüksek bir performans sergilemiştir. Güç artışıyla THP’deki plakalı modelin avantajı azalmıştır.
- 28 December 2023
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 11 (4) , 951-965
Open AccessPlaka Kanatlı Isı Dağıtıcı Termal Performansının Deneysel Olarak Zorlanmış Konveksiyonda İncelenmesi
Bu çalışmada, plaka kanatlara (PID) sahip ısı dağıtıcının karşılaştırmalı olarak kanatsız düz ısı dağıtıcı (DID) ile termal performansı 30 ℃ ortam sıcaklığında, 33-66-99 W ısıl güçlerinde ve 2000-16000 Reynolds sayısı aralıklarında deneysel olarak incelenmiştir. Güç ortalaması dikkate alınarak plaka model düze göre yüzey sıcaklıklarında 57 ℃ ve eklem sıcaklıklarında 30.5 ℃’lik avantaj sağlamıştır. Nu sayısında plakalı model düze göre güçler için sırasıyla %79, %35 ve %38 daha yüksek olup buradan bariz olarak 33 W’ta oldukça iyi bir ısı transfer performansı sergilemiştir. Termal dirençte plakalı model düze göre güçler için sırasıyla 0.61, 0.50 ve 0.39 K/W daha düşük değerlere sahip olup güç artışıyla azalan bir eğilim göstermiştir. Plakalı modelin basınç kaybı düze göre güçler için sırasıyla 0.88, 0.75 ve 1.13 Pa yüksek gerçekleşmiştir. Basınç kaybındaki bu küçük farkların, plakalı modelin akışa paralel kanatlara sahip olmasının payı büyüktür. THP’de ise plakalı model düze göre güçler için sırasıyla %40, %10 ve %10 avantaj sağlamış ve özellikle 33 W için bariz yüksek bir performans sergilemiştir. Güç artışıyla THP’deki plakalı modelin avantajı azalmıştır.
- 22 April 2020
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 45 (7) , 5729-5740
Thermodynamic Performance Evaluation of Concentrating Solar Collector with Supercritical Carbon Dioxide (sCO2) Base Nanofluids
- 22 April 2020
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 45 (7) , 5729-5740
Thermodynamic Performance Evaluation of Concentrating Solar Collector with Supercritical Carbon Dioxide (sCO2) Base Nanofluids
- Open Access
- 31 January 2020
- Published by El-Cezeri: Journal of Science and Engineering in El-Cezeri Fen ve Mühendislik Dergisi
- Vol. 7 (1)
Hidrojen Üretimi için Üç Adımlı Cu-Cl Termokimyasal Sistemin Enerji ve Ekserji Analizi
Termokimyasal çevrim sistemleri yenilenebilir enerji kaynaklarından elde edilen ısı ve elektrik enerjisini kullanarak sera gazları salınımı olmadan hidrojen üretimi yaparlar. Sunulan çalışmada tasarlanan yüksek sıcaklık Cu-Cl termokimyasal çevrim sisteminin enerji ve ekserji analizleri gerçekleştirilmiştir. Yapılan analizler farklı referans sıcaklık değerleri ve değişen reaksiyon sıcaklıklarına göre incelenerek parametrik çalışmalar oluşturulmuştur. Çevrimin her bir adımı için ekserji hızları, ekserji yıkımları ve tüm çevrimin ekserji verimi araştırılmıştır. 25 o C referans çevre sıcaklığında Cu-Cl termokimyasal çevrimin enerji ve ekserji verimleri sırasıyla 55.41% ve 66.09% bulunmuştur. Ayrıca incelenen sistemdeki en büyük ekserji yıkımı hidrojen üretim adımında gerçekleşmiştir.
- 31 January 2020
- Published by El-Cezeri: Journal of Science and Engineering in El-Cezeri Fen ve Mühendislik Dergisi
- Vol. 7 (1)
Open AccessHidrojen Üretimi için Üç Adımlı Cu-Cl Termokimyasal Sistemin Enerji ve Ekserji Analizi
Termokimyasal çevrim sistemleri yenilenebilir enerji kaynaklarından elde edilen ısı ve elektrik enerjisini kullanarak sera gazları salınımı olmadan hidrojen üretimi yaparlar. Sunulan çalışmada tasarlanan yüksek sıcaklık Cu-Cl termokimyasal çevrim sisteminin enerji ve ekserji analizleri gerçekleştirilmiştir. Yapılan analizler farklı referans sıcaklık değerleri ve değişen reaksiyon sıcaklıklarına göre incelenerek parametrik çalışmalar oluşturulmuştur. Çevrimin her bir adımı için ekserji hızları, ekserji yıkımları ve tüm çevrimin ekserji verimi araştırılmıştır. 25 o C referans çevre sıcaklığında Cu-Cl termokimyasal çevrimin enerji ve ekserji verimleri sırasıyla 55.41% ve 66.09% bulunmuştur. Ayrıca incelenen sistemdeki en büyük ekserji yıkımı hidrojen üretim adımında gerçekleşmiştir.
- 12 February 2019
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 44 (6) , 5195-5213
Evaluation of Heat Transfer Mechanisms in Heat Pipe Charged with Nanofluid
- 12 February 2019
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 44 (6) , 5195-5213
Evaluation of Heat Transfer Mechanisms in Heat Pipe Charged with Nanofluid
- 4 September 2018
- Published by Pleiades Publishing Ltd in Russian Journal of Physical Chemistry A
- Vol. 92 (9) , 1762-1771
Optimizing Optical and Structural Properties of Nanocomposites by ZnO and BP-3
This study aims to find out usage of zinc oxide (ZnO) and 2-hydroxy-4-methoxybenzophenone (BP-3) for getting better optical and structural properties of nanocomposites. Polymer nanocomposites...
- 4 September 2018
- Published by Pleiades Publishing Ltd in Russian Journal of Physical Chemistry A
- Vol. 92 (9) , 1762-1771
Optimizing Optical and Structural Properties of Nanocomposites by ZnO and BP-3
This study aims to find out usage of zinc oxide (ZnO) and 2-hydroxy-4-methoxybenzophenone (BP-3) for getting better optical and structural properties of nanocomposites. Polymer nanocomposites...