JLJuslan Lo

Juslan Lo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Juslan Lo has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Low-Voltage Plasma Jet With Piezoelectric Generator: Preliminary Evaluation of Decontamination Capabilities

    by Jordan Stekke, Claire Tendero, Pascal Tierce, Christian Courtois, Gaetan Rauwel, Juslan Lo, Philippe Guillot, Francois Pigache

    This article deals with the proof of concept and the preliminary evaluation of decontamination performances obtained with a plasma jet generated by a piezoelectric transformer (PT). This low-voltage supply solution (<; 10 V) is investigated as a plasma jet device, compact and safe solution for the decontamination of medical thermo-sensitive devices. The principle of the piezoelectric generator is presented, followed by the optical s-protocol conditions for the bactericidal effect observations, and finally the reduction rates obtained on Pseudomonas aeruginosa and Staphylococcus aureus bacteria strains with an argon plasma jet at atmospheric pressure about 2.5-W electrical input power.


  • Heating power at the substrate, electron temperature, and electron density in 2.45 GHz low-pressure microwave plasma

    by A. Kais, J. Lo, L. Thérèse, Ph. Guillot

    To control the temperature during a plasma treatment, an understanding of the link between the plasma parameters and the fundamental process responsible for the heating is required. In this work, the power supplied by the plasma onto the surface of a glass substrate is measured using the calorimetric method. It has been shown that the powers deposited by ions and electrons, and their recombination at the surface are the main contributions to the heating power. Each contribution is estimated according to the theory commonly used in the literature. Using the corona balance, the Modified Boltzmann Plot (MBP) is employed to determine the electron temperature. A correlation between the power deposited by the plasma and the results of the MBP has been established. This correlation has been used to estimate the electron number density independent of the Langmuir probe in considered conditions.


  • 2.45-GHz microwave plasma sources using solid-state microwave generators. Collisional-type plasma source

    by Louis Latrasse, Marilena Radoiu, Juslan Lo, Philippe Guillot

    The availability of high power solid-state microwave generators opens new directions in plasma generation with applications in industrial plasma processing at low pressure. The optimization of the plasma production line, i.e. from the microwave generator to the plasma source, is a requisite to enable the scaling-up while ensuring a robust control of the equipment. In addition to the electron cyclotron resonance (ECR) coaxial microwave plasma source previously reported, a collisional plasma source was developed for processing at 1–100 Pa. Similar to the ECR plasma source, the results of measurements performed with the collisional plasma source demonstrate that plasma density and uniformity are highly dependent on the microwave power, the reactor pressure and the distance to and between plasma sources. It was demonstrated that the collisional plasma source can attain very high plasma densities, i.e. >1012 cm−3 in argon and >1011 cm−3 in molecular gases like O2, N2, air, H2, making it suitable for high deposition rate plasma-enhanced chemical vapour deposition or for high density production of reactive species. A comparison of the two microwave plasma sources is given for the main plasma parameters; the choice of one plasma source over the other depends on the intended process/operating pressure.


  • 2.45-GHz microwave plasma sources using solid-state microwave generators. ECR-type plasma source

    by Louis Latrasse, Marilena Radoiu, Juslan Lo, Philippe Guillot

    To meet industrial requirements for large-scale processing with high-density and uniform plasma, mandatory for surface treatments to get uniform etching and high deposition rates, we have conceived a new electron cyclotron resonance (ECR) coaxial microwave plasma source which can sustain stable plasmas from 10−2 Pa to a few Pa, whatever the processing gas, the minimum sustaining microwave power being only a few watt. Furthermore, because the plasma source is powered by its own microwave solid-state generator, multiple ECR plasma sources operating in different conditions of gas type and microwave power can be distributed together in the same reactor. In this design, the solid-state microwave generator produces a forward wave with variable frequency from 2400 to 2500 MHz; this feature is used in an automatic adjustment loop which enables to lower the reflected power created occasionally by changes in the operating conditions. The advantages of the new technology are reported in connection with the plasma scaling-up requirements to distribute uniformly the electric field over large areas. Optical emission spectroscopy and Langmuir probe have been used for the measurement of plasma density, uniformity and electron temperature in argon, oxygen and nitrogen. The results are reported in as a function of the gas type, number of sources and their distribution inside the plasma reactor. The new plasma source enables the production of plasma densities >1011 cm−3 in all tested gases – Ar, O2, N2, air – at d = 85 mm.


  • Comparison of plasma sources for surface treatment applications: Radiofrequency inductively coupled and surface-wave microwave plasma sources

    by Christopher Laurent, Juslan Lo, Bruno Caillier, Laurent Therese, Phillipe Guillot

    Summary form only given. This work was conducted within the framework of PAUD (Plasma Airborne molecular contamination Ultra Desorption), a collaborative program funded by OSEO and certified by French global competitive clusters Minalogic and Trimatec. The main object of interest is to develop new technology bricks for next generation molecular decontamination systems. As part of our research effort in evaluating the potential of plasma treatment as a solution, the performance of different plasma sources was evaluated.Here, we will show the electronic density and temperature radial profiles, as well as plasma emission at different locations obtained with both plasma sources. The results will be presented as a function of sources injected power (up to 2 kW), argon gas flow (10 ~ 300 sccm) and pressure (5 10-3 ~5 10-1 mbar).


  • Non-thermal plasma potentialities for microwave device reconfigurability

    by Jérôme Sokoloff, Olivier Pascal, Thierry Callegari, Romain Pascaud, Francisco Pizarro, Laurent Liard, Juslan Lo, Asma Kallel

    Three examples of results achieved from cooperative works with microwave and plasma research groups in Toulouse (France) are presented in this paper. They are focused on the use of few non-thermal plasmas to make a microwave device reconfigurable. The relative permittivity of such a plasma medium can be tuned from unity to negative values. This special feature appears to be very attractive, although the electromagnetic losses are significant. The use of plasmas with planar waveguides and within metamaterials is discussed. In addition, the basic principles of a scanning antenna built with a leaky wave in a plasma layer are presented.


  • Experimental and numerical characterization of an argon RF inductively coupled plasma for surface treatment

    by Christopher Laurent, Juslan Lo, Bruno Caillier, Laurent Therese, Philippe Guillot, Diana Mihailova, Gerjan Hagelaar, Philippe Belenguer

    Summary form only given. Plasma-surface interactions depend highly on plasma parameters offering an appreciable versatility on the use of plasma discharges for surface treatment applications including surface cleaning, surface etching, wettability and adhesion increase, friction reduction, cell attachment improvement and surface-protein interactions alteration. This work is supported by the French public funding agency OSEO and aims to provide surface treatment solutions with an Inductively Coupled Plasma (ICP) source. Prior to any treatment attempt, experimental and numerical diagnostics have been conducted on an ICP discharge in argon in order to obtain a better understanding of the plasma behavior and properties. In our experimental setup, the discharge is generated with a 13.56 MHz radiofrequency ICP source within a cylindrical quartz tube. The tube is connected to a separate process chamber where samples to be treated may be inserted. The gas parameters are the argon flow rate (<; 500 sccm) and the pressure (<; 1 mbar). Optical emission spectroscopy diagnostics are conducted with an Automated Imaging Spectrometer (iHR320 Horiba Jobin Yvon) and a Princeton Instruments PI-MAX intensified CCD camera. Moreover, Langmuir Double Probe diagnostics are done with an Impedans ALP Sytem (Impedans Ltd). Simultaneous measurements are performed through different reactor openings for spatio-temporal characterization. In parallel, a time dependent 2 dimensional fluid model is developed for comparison purpose1. The numerical model is applied to a simplified 2D geometry corresponding to the experimental chamber with pure Ar gas. In both numerical and experimental domain, the influence of various parameters, particularly gas pressure and injected power, are studied. In this work, basic plasma characteristics such as optical emission and electron temperature in the chamber will be provided. In addition, comparison between the experimental and simulation results will be presented.

  • Reconfigurable electromagnetic band gap device using plasma as a localized tunable defect

    by J. Lo, J. Sokoloff, Th. Callegari, J. P. Boeuf

    Electromagnetic band gap (EBG) structures have interesting properties in terms of electromagnetic wave propagation. Using a plasma discharge in an EBG structure may increase its reconfigurability. The use of microplasma arrays in the design of EBG structures is however complex and may cause energy losses. In this paper, we show through experiments and simulations that EBG effects can be obtained in structures where a single discharge plasma is used to create a defect in a periodic structure of metallic rods.


  • Empirical electron cross-field mobility in a Hall effect thruster

    by L. Garrigues, J. Pérez-Luna, J. Lo, G. J. M. Hagelaar, J. P. Boeuf, S. Mazouffre

    Electron transport across the magnetic field in Hall effect thrusters is still an open question. Models have so far assumed 1∕B2 or 1∕B scaling laws for the “anomalous” electron mobility, adjusted to reproduce the integrated performance parameters of the thruster. We show that models based on such mobility laws predict very different ion velocity distribution functions (IVDF) than measured by laser induced fluorescence (LIF). A fixed spatial mobility profile, obtained by analysis of improved LIF measurements, leads to much better model predictions of thruster performance and IVDF than 1∕B2 or 1∕B mobility laws for discharge voltages in the 500–700V range.