Ming-You Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ming-You Xu has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Yong-Cheng Hu
Clinical School/College of Orthopedics, Tianjin Medical University, Tianjin, China
8 shared publications - Feng Wang
Graduate School, Tianjin Medical University, Tianjin, China
3 shared publications - Haoran Zhang
Department of Orthopedic Surgery, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, People’s Republic of China
3 shared publications - Xiong-Gang Yang
Graduate School, Tianjin Medical University, 22 Qixiangtai Road, Tianjin, China
3 shared publications - Deng‐Xing Lun
Department of Spinal Surgery, Weifang People’s Hospital, Shandong Second Medical University, Weifang, China
2 shared publications Hao‐Ran Zhang
Department of Bone and Soft Tissue Oncology Tianjin Hospital Tianjin China
2 shared publications
Latest Publications
- Open Access
- 19 March 2026
- Published by Oxford University Press (OUP) in Nucleic Acids Research
- Vol. 54 (6)
Development and application of G4-Flame as a visual biosensor for G4-DNA
G-quadruplex DNA (G4-DNA), a noncanonical tetrahelical nucleic acid structure stabilized by stacked G-quartets via Hoogsteen hydrogen bonding, plays critical roles in genomic regulation and disease pathogenesis. Current methodologies for detecting these structures face limitations in specificity, spatiotemporal resolution, and live-cell applicability. To address these challenges, we engineered G4-Flame, a genetically encoded fluorescent biosensor utilizing circularly permuted fluorescent protein technology. By strategically positioning a G4-specific binding domain proximal to the fluorophore of circularly permuted YFP (cpYFP), G4-Flame achieves real-time, high-resolution visualization of G4-DNA dynamics in living systems, with specificity across diverse G4 conformations. Experimental validation revealed distinct spatiotemporal patterns of G4-DNA during the cell cycle: nuclear G4-DNA levels peaked during the S phase, while mitochondrial G4-DNA was found to suppress the expression of mitochondrial-encoded genes. Clinically, serum analysis revealed significantly elevated G4-DNA levels in cancer patients compared to healthy controls. This work establishes G4-Flame as a transformative tool for investigating G4-DNA spatiotemporal regulation and advances its potential as a biomarker for early cancer detection, bridging fundamental research with clinical translation.
- 19 March 2026
- Published by Oxford University Press (OUP) in Nucleic Acids Research
- Vol. 54 (6)
Open AccessDevelopment and application of G4-Flame as a visual biosensor for G4-DNA
G-quadruplex DNA (G4-DNA), a noncanonical tetrahelical nucleic acid structure stabilized by stacked G-quartets via Hoogsteen hydrogen bonding, plays critical roles in genomic regulation and disease pathogenesis. Current methodologies for detecting these structures face limitations in specificity, spatiotemporal resolution, and live-cell applicability. To address these challenges, we engineered G4-Flame, a genetically encoded fluorescent biosensor utilizing circularly permuted fluorescent protein technology. By strategically positioning a G4-specific binding domain proximal to the fluorophore of circularly permuted YFP (cpYFP), G4-Flame achieves real-time, high-resolution visualization of G4-DNA dynamics in living systems, with specificity across diverse G4 conformations. Experimental validation revealed distinct spatiotemporal patterns of G4-DNA during the cell cycle: nuclear G4-DNA levels peaked during the S phase, while mitochondrial G4-DNA was found to suppress the expression of mitochondrial-encoded genes. Clinically, serum analysis revealed significantly elevated G4-DNA levels in cancer patients compared to healthy controls. This work establishes G4-Flame as a transformative tool for investigating G4-DNA spatiotemporal regulation and advances its potential as a biomarker for early cancer detection, bridging fundamental research with clinical translation.
- Open Access
- 4 March 2025
- Published by Elsevier in Materials Today Bio
- Vol. 31, 101629
Peptide-modified mesoporous silica nanoparticles for the coordinated regulation of macrophage polarization and pyroptosis in the treatment of implant-related infections
- 4 March 2025
- Published by Elsevier in Materials Today Bio
- Vol. 31, 101629
Open AccessPeptide-modified mesoporous silica nanoparticles for the coordinated regulation of macrophage polarization and pyroptosis in the treatment of implant-related infections
- Open Access
- 24 August 2022
- Published by Wiley in Orthopaedic Surgery
- Vol. 14 (10) , 2657-2668
Effects of Chemical Sterilization and Gamma Irradiation on the Biochemical and Biomechanical Properties of Human Tendon Allografts In Vitro Study
Objective: Pre‐implantation sterilization procedures for tendons are important measures to reduce the risk of disease transmission, however these procedures may compromise tendon microarchitecture and biomechanical properties to varying degrees. We explore the effects of different sterilization procedures on the micro‐histology, biomechanical strength and biochemical properties of human tendon allografts in vitro study.Methods: The tendon allografts were harvested from cadaveric donors after the donors were serologically screened by antibody or nucleic acid testing of infectious agents. All samples were divided into five groups, which were fresh‐frozen group (control group), 15 kGy gamma irradiation group, 25 kGy gamma irradiation group, 70% ethanol group, and peracetic acid‐ethanol group. Each group included 10 tendons for testing. Histological staining and transmission electron microscopy were applied to observe the internal structure and arrangement of tendon collagen fibers, while the machine learning classifier was trained to distinguish the darker cross‐sections of collagen fibers and brighter backgrounds of the electron micrograph to detect the distribution of diameters of tendon collagen fibers. The viscoelasticity, mechanical properties and material properties of tendon allografts were examined to detect the influence of different intervention factors on the biomechanical properties of tendons.Results: Histological staining and transmission electron microscopy showed that the structure of fresh‐frozen tendons was similar to the structures of other experimental groups, and no obvious fiber disorder or delamination was observed. In the uniaxial cyclic test, the cyclic creep of 25 kGy irradiation group (1.5%) and peracetic acid‐ethanol group (1.5%) were significantly lower than that of the control group (3.6%, F = 1.52, P = 0.039) while in the load‐to‐failure test, the maximum elongation and maximum strain of the peracetic acid‐ethanol group were significantly higher than those of the control group (F = 4.60, P = 0.010), and there was no significant difference in other biomechanical indicators. According to the experimental results of denatured collagen, it could be seen that no matter which disinfection procedure was used, the denaturation of the tendon sample would be promoted (F = 1.97, P = 0.186), and high‐dose irradiation seemed to cause more damage to collagen fibers than the other two disinfection procedures (296.2 vs 171.1 vs 212.9 μg/g).Conclusion: Biomechanical experiments and collagen denaturation tests showed that 15 kGy gamma irradiation and 70% ethanol can preserve the biomechanical strength and biochemical properties of tendons to the greatest extent, and these two sterilization methods are worthy of further promotion.
- 24 August 2022
- Published by Wiley in Orthopaedic Surgery
- Vol. 14 (10) , 2657-2668
Open AccessEffects of Chemical Sterilization and Gamma Irradiation on the Biochemical and Biomechanical Properties of Human Tendon Allografts In Vitro Study
Objective: Pre‐implantation sterilization procedures for tendons are important measures to reduce the risk of disease transmission, however these procedures may compromise tendon microarchitecture and biomechanical properties to varying degrees. We explore the effects of different sterilization procedures on the micro‐histology, biomechanical strength and biochemical properties of human tendon allografts in vitro study.Methods: The tendon allografts were harvested from cadaveric donors after the donors were serologically screened by antibody or nucleic acid testing of infectious agents. All samples were divided into five groups, which were fresh‐frozen group (control group), 15 kGy gamma irradiation group, 25 kGy gamma irradiation group, 70% ethanol group, and peracetic acid‐ethanol group. Each group included 10 tendons for testing. Histological staining and transmission electron microscopy were applied to observe the internal structure and arrangement of tendon collagen fibers, while the machine learning classifier was trained to distinguish the darker cross‐sections of collagen fibers and brighter backgrounds of the electron micrograph to detect the distribution of diameters of tendon collagen fibers. The viscoelasticity, mechanical properties and material properties of tendon allografts were examined to detect the influence of different intervention factors on the biomechanical properties of tendons.Results: Histological staining and transmission electron microscopy showed that the structure of fresh‐frozen tendons was similar to the structures of other experimental groups, and no obvious fiber disorder or delamination was observed. In the uniaxial cyclic test, the cyclic creep of 25 kGy irradiation group (1.5%) and peracetic acid‐ethanol group (1.5%) were significantly lower than that of the control group (3.6%, F = 1.52, P = 0.039) while in the load‐to‐failure test, the maximum elongation and maximum strain of the peracetic acid‐ethanol group were significantly higher than those of the control group (F = 4.60, P = 0.010), and there was no significant difference in other biomechanical indicators. According to the experimental results of denatured collagen, it could be seen that no matter which disinfection procedure was used, the denaturation of the tendon sample would be promoted (F = 1.97, P = 0.186), and high‐dose irradiation seemed to cause more damage to collagen fibers than the other two disinfection procedures (296.2 vs 171.1 vs 212.9 μg/g).Conclusion: Biomechanical experiments and collagen denaturation tests showed that 15 kGy gamma irradiation and 70% ethanol can preserve the biomechanical strength and biochemical properties of tendons to the greatest extent, and these two sterilization methods are worthy of further promotion.
- Open Access
- 3 September 2021
- Published by Wiley in Orthopaedic Surgery
Peracetic Acid‐Ethanol Processed Human Tendon Allograft: A Morphological, Biochemical, and Biomechanical Study In Vitro
Objective To clarify the morphological, biochemical, and biomechanical effects of peracetic acid-ethanol sterilization processing to human hamstring tendon allografts for different time periods. Methods Thirty-two fresh-frozen human hamstring tendon allografts obtained from an allograft supplier were prepared and incubated in peracetic acid-ethanol solution (PES) containing 1% v/v peracetic acid and 24% v/v ethanol. Specimens were randomly classified into four groups according to the PES processing time (untreated as the control group, 30 min as the PES30 group, 120 min as the PES120 group, and 240 min as the PES240group). Light microscopy with hematoxylin–eosin and toluidine blue were performed, along with transmission electron microscopy (TEM) to measure the collagen fibril diameters and their distributions, from which the collagen fibril index (CFI) and mass average diameter (MAD) were calculated. The thermal stability and collagen denaturation were analyzed by differential scanning calorimetry (DSC) and collagen denaturation test by α-chymotrypsin. Cyclic loading and failure testing were applied on five tendons from each group, from which the cyclic creep strain, elastic modulus, maximum stress, maximum strain, and strain energy density were calculated. Results Tendons in the control, PES30, PES120 groups showed similar regularly aligned collagen fibers in light microscopy images, while the images from the PES240 group revealed relatively disordered and heterogeneous collagen bundles with larger interfiber spaces. TEM analysis showed that the mean diameter (F = 3.09, P = 0.04) was lower in the PES120 group (87.15 ± 4.76 nm) than it was in the control group (99.39 ± 9.19 nm) but not statistically (P = 0.05). Moreover, the CFI value in the PES30 group (65.37 ± 4.14%) was the lowest among groups (all P ≤ 0.01), while no variance existed in density and MAD among groups (F = 2.09, P = 0.13, and F = 0.27, P = 0.85, respectively). The onset temperature (H = 8.74, P = 0.03) and peak temperature (H = 9.97, P = 0.02) were decreased in the PES30 group compared to the control group (P = 0.02 and P = 0.01, respectively), but there were no differences in enthalpy of denaturation among groups (F = 2.20, P = 0.17). The collagen denaturation test revealed lower hydroxyproline concentrations in PES-treated specimens with no statistical differences among groups (H = 8.86, P = 0.07). The maximum stress showed variance (F = 10.52, P < 0.01) that it was higher in PES30 group (68.29 ± 10.86 MPa) compared to the PES120 and the PES240 group, while it was lower in the PES120 group (19.40 ± 4.94 MPa) compared to the control and the PES30 group (all P < 0.05). The strain energy density (F = 7.34, P < 0.01) was over 4 times higher in the PES30 group (7.39 ± 2.51 MPa) than it was in the PES120 group (1.56 ± 0.64 MPa, P < 0.01). Conclusion PES treatment for 30 min has no adverse effect on the properties of human hamstring tendon allografts, longer processing time could not promise better properties preservation.
- 3 September 2021
- Published by Wiley in Orthopaedic Surgery
Open AccessPeracetic Acid‐Ethanol Processed Human Tendon Allograft: A Morphological, Biochemical, and Biomechanical Study In Vitro
Objective To clarify the morphological, biochemical, and biomechanical effects of peracetic acid-ethanol sterilization processing to human hamstring tendon allografts for different time periods. Methods Thirty-two fresh-frozen human hamstring tendon allografts obtained from an allograft supplier were prepared and incubated in peracetic acid-ethanol solution (PES) containing 1% v/v peracetic acid and 24% v/v ethanol. Specimens were randomly classified into four groups according to the PES processing time (untreated as the control group, 30 min as the PES30 group, 120 min as the PES120 group, and 240 min as the PES240group). Light microscopy with hematoxylin–eosin and toluidine blue were performed, along with transmission electron microscopy (TEM) to measure the collagen fibril diameters and their distributions, from which the collagen fibril index (CFI) and mass average diameter (MAD) were calculated. The thermal stability and collagen denaturation were analyzed by differential scanning calorimetry (DSC) and collagen denaturation test by α-chymotrypsin. Cyclic loading and failure testing were applied on five tendons from each group, from which the cyclic creep strain, elastic modulus, maximum stress, maximum strain, and strain energy density were calculated. Results Tendons in the control, PES30, PES120 groups showed similar regularly aligned collagen fibers in light microscopy images, while the images from the PES240 group revealed relatively disordered and heterogeneous collagen bundles with larger interfiber spaces. TEM analysis showed that the mean diameter (F = 3.09, P = 0.04) was lower in the PES120 group (87.15 ± 4.76 nm) than it was in the control group (99.39 ± 9.19 nm) but not statistically (P = 0.05). Moreover, the CFI value in the PES30 group (65.37 ± 4.14%) was the lowest among groups (all P ≤ 0.01), while no variance existed in density and MAD among groups (F = 2.09, P = 0.13, and F = 0.27, P = 0.85, respectively). The onset temperature (H = 8.74, P = 0.03) and peak temperature (H = 9.97, P = 0.02) were decreased in the PES30 group compared to the control group (P = 0.02 and P = 0.01, respectively), but there were no differences in enthalpy of denaturation among groups (F = 2.20, P = 0.17). The collagen denaturation test revealed lower hydroxyproline concentrations in PES-treated specimens with no statistical differences among groups (H = 8.86, P = 0.07). The maximum stress showed variance (F = 10.52, P < 0.01) that it was higher in PES30 group (68.29 ± 10.86 MPa) compared to the PES120 and the PES240 group, while it was lower in the PES120 group (19.40 ± 4.94 MPa) compared to the control and the PES30 group (all P < 0.05). The strain energy density (F = 7.34, P < 0.01) was over 4 times higher in the PES30 group (7.39 ± 2.51 MPa) than it was in the PES120 group (1.56 ± 0.64 MPa, P < 0.01). Conclusion PES treatment for 30 min has no adverse effect on the properties of human hamstring tendon allografts, longer processing time could not promise better properties preservation.
- 1 April 2020
- Published by Elsevier in Cancer Letters
- Vol. 475, 136-142
Percutaneous vertebral augmentation procedures in the management of spinal metastases
- 1 April 2020
- Published by Elsevier in Cancer Letters
- Vol. 475, 136-142
Percutaneous vertebral augmentation procedures in the management of spinal metastases
- Open Access
- 18 March 2020
- Published by Wiley in Orthopaedic Surgery
- Vol. 12 (2) , 617-630
Assessment of the Defatting Efficacy of Mechanical and Chemical Treatment for Allograft Cancellous Bone and Its Effects on Biomechanics Properties of Bone
Objective To assess the defatting efficacy of high pressure washing and gradient alcohol and biomechanical properties of defatted bone. Methods Fresh cancellous bone was obtained from the femoral condyle and divided into six groups according to different defatting treatments, which were: high pressure washing for 10 s (10S group), 20 s (20S group), and 30 s (30S group), gradient alcohol immersion (Alcohol group), acetone immersion (Acetone group), and non‐defatted (Fresh group). The appearance of six groups was observed, and the appearance of defatted bone and fresh bone was compared. The residual lipid content and infrared spectrum were used to compare the efficacy of defatting, the DNA content was used to compare the cell content after defatting, and the maximum stress and elastic modulus were used to compare the effects of defatting treatment on biomechanical properties. Results The fresh bone was yellow and the pores contained a lot of fat. The defatted bone was white and the porous network was clear. There was no difference in residual lipid content among the three groups with high pressure washing (1.45% ± 0.16%, 1.40% ± 0.13%, and 1.46% ± 0.11%, respectively) (P = 0.828). There was no difference in residual lipid content among the 10S, alcohol, and acetone groups (1.45% ± 0.16%, 1.28% ± 0.07%, and 1.13% ± 0.22%, respectively) (P = 0.125). Infrared spectra showed that the fat content of the five defatting groups was significantly lower than that of the fresh group. There was no difference in residual lipid content among the three groups with high pressure washing (4.53 ± 0.23 ug/mL, 4.61 ± 0.18 ug/mL, and 4.66 ± 0.25 ug/mL, respectively) (P = 0.645). There was no difference in residual lipid content among the 10S, alcohol, and acetone groups (4.53 ± 0.23 ug/mL, 4.29 ± 0.24 ug/mL, and 4.27 ± 0.29 ug/mL, respectively) (P = 0.247). The maximum stress of the bone decreased significantly with the increase of the washing time (9.95 ± 0.31 Mpa, 9.07 ± 0.45 Mpa, and 8.17 ± 0.35 Mpa, respectively) (P = 0.003). The elastic modulus of the bone decreased significantly with the increase of the washing time (116.40 ± 3.54 Mpa, 106.10 ± 5.29 Mpa, and 95.63 ± 4.08 Mpa, respectively) (P = 0.003). There was no statistical difference in the maximum stress between the fresh group, the 10S group, the alcohol group, and the acetone group (10.09 ± 0.67 Mpa, 9.95 ± 0.31 Mpa, 10.11 ± 0.07 Mpa, and 10.09 ± 0.39 Mpa, respectively) (P = 0.963). There was no statistical difference in the maximum stress between the fresh group, the 10S group, the alcohol group and the acetone group (119.93 ± 4.94 Mpa, 116.40 ± 3.54 Mpa, 118.27 ± 0.85 Mpa, 118.10 ± 4.52 Mpa, respectively) (P = 0.737). Conclusion The defatting efficiency was satisfactory at a time of 10 s under high pressure washing. In terms of defatting efficiency and its effect on biomechanical properties of bone, high pressure washing and gradient alcohol were similar to conventional acetone solvent extraction defatting.
- 18 March 2020
- Published by Wiley in Orthopaedic Surgery
- Vol. 12 (2) , 617-630
Open AccessAssessment of the Defatting Efficacy of Mechanical and Chemical Treatment for Allograft Cancellous Bone and Its Effects on Biomechanics Properties of Bone
Objective To assess the defatting efficacy of high pressure washing and gradient alcohol and biomechanical properties of defatted bone. Methods Fresh cancellous bone was obtained from the femoral condyle and divided into six groups according to different defatting treatments, which were: high pressure washing for 10 s (10S group), 20 s (20S group), and 30 s (30S group), gradient alcohol immersion (Alcohol group), acetone immersion (Acetone group), and non‐defatted (Fresh group). The appearance of six groups was observed, and the appearance of defatted bone and fresh bone was compared. The residual lipid content and infrared spectrum were used to compare the efficacy of defatting, the DNA content was used to compare the cell content after defatting, and the maximum stress and elastic modulus were used to compare the effects of defatting treatment on biomechanical properties. Results The fresh bone was yellow and the pores contained a lot of fat. The defatted bone was white and the porous network was clear. There was no difference in residual lipid content among the three groups with high pressure washing (1.45% ± 0.16%, 1.40% ± 0.13%, and 1.46% ± 0.11%, respectively) (P = 0.828). There was no difference in residual lipid content among the 10S, alcohol, and acetone groups (1.45% ± 0.16%, 1.28% ± 0.07%, and 1.13% ± 0.22%, respectively) (P = 0.125). Infrared spectra showed that the fat content of the five defatting groups was significantly lower than that of the fresh group. There was no difference in residual lipid content among the three groups with high pressure washing (4.53 ± 0.23 ug/mL, 4.61 ± 0.18 ug/mL, and 4.66 ± 0.25 ug/mL, respectively) (P = 0.645). There was no difference in residual lipid content among the 10S, alcohol, and acetone groups (4.53 ± 0.23 ug/mL, 4.29 ± 0.24 ug/mL, and 4.27 ± 0.29 ug/mL, respectively) (P = 0.247). The maximum stress of the bone decreased significantly with the increase of the washing time (9.95 ± 0.31 Mpa, 9.07 ± 0.45 Mpa, and 8.17 ± 0.35 Mpa, respectively) (P = 0.003). The elastic modulus of the bone decreased significantly with the increase of the washing time (116.40 ± 3.54 Mpa, 106.10 ± 5.29 Mpa, and 95.63 ± 4.08 Mpa, respectively) (P = 0.003). There was no statistical difference in the maximum stress between the fresh group, the 10S group, the alcohol group, and the acetone group (10.09 ± 0.67 Mpa, 9.95 ± 0.31 Mpa, 10.11 ± 0.07 Mpa, and 10.09 ± 0.39 Mpa, respectively) (P = 0.963). There was no statistical difference in the maximum stress between the fresh group, the 10S group, the alcohol group and the acetone group (119.93 ± 4.94 Mpa, 116.40 ± 3.54 Mpa, 118.27 ± 0.85 Mpa, 118.10 ± 4.52 Mpa, respectively) (P = 0.737). Conclusion The defatting efficiency was satisfactory at a time of 10 s under high pressure washing. In terms of defatting efficiency and its effect on biomechanical properties of bone, high pressure washing and gradient alcohol were similar to conventional acetone solvent extraction defatting.
- Open Access
- 25 February 2020
- Published by Wiley in Orthopaedic Surgery
- Vol. 12 (2) , 366-371
Optical Microscopy and Electron Microscopy for the Morphological Evaluation of Tendons: A Mini Review
The morphological characteristics of tendons have been thoroughly evaluated via microscopy. Optical microscopy and electron microscopy are the most commonly used techniques for tendon tissue observation. According to the principles of both microscopy types, preparation and evaluation methods vary. Simple optical microscopy is commonly used in the observation of cells and extracellular matrix, and many stains, including hematoxylin–eosin, Van Gieson, Prussian blue, Alcian blue, and toluidine blue, are used for evaluating cells, collagen fiber arrangement, and noncollagenous proteins. Histological scoring systems have been used in many studies for semi‐quantification. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) are the most commonly used electron microscopy types, and special consideration is needed for the fixation and embedding protocols. Glutaraldehyde followed by osmium is most commonly used in the chemical fixation of tendon tissue, followed by epoxy resin embedment. Longitudinal sections captured in SEM images show the arrangement of collagen fibrils and the cells and lipid drops among them, while cross sections captured in TEM images show the diameter and distribution of collagen fibrils. SEM and TEM are used together for comprehensive evaluations. This mini review is focused on the preparation methodology and related evaluation indexes for the morphological evaluation of tendons.
- 25 February 2020
- Published by Wiley in Orthopaedic Surgery
- Vol. 12 (2) , 366-371
Open AccessOptical Microscopy and Electron Microscopy for the Morphological Evaluation of Tendons: A Mini Review
The morphological characteristics of tendons have been thoroughly evaluated via microscopy. Optical microscopy and electron microscopy are the most commonly used techniques for tendon tissue observation. According to the principles of both microscopy types, preparation and evaluation methods vary. Simple optical microscopy is commonly used in the observation of cells and extracellular matrix, and many stains, including hematoxylin–eosin, Van Gieson, Prussian blue, Alcian blue, and toluidine blue, are used for evaluating cells, collagen fiber arrangement, and noncollagenous proteins. Histological scoring systems have been used in many studies for semi‐quantification. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) are the most commonly used electron microscopy types, and special consideration is needed for the fixation and embedding protocols. Glutaraldehyde followed by osmium is most commonly used in the chemical fixation of tendon tissue, followed by epoxy resin embedment. Longitudinal sections captured in SEM images show the arrangement of collagen fibrils and the cells and lipid drops among them, while cross sections captured in TEM images show the diameter and distribution of collagen fibrils. SEM and TEM are used together for comprehensive evaluations. This mini review is focused on the preparation methodology and related evaluation indexes for the morphological evaluation of tendons.
- 2 January 2020
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 21 (1) , 17-29
The influence of donor and recipient characteristics on allograft tendons: a systematic review
Tendon allograft has been an important alternative graft option aside from autograft. The outcome of reconstruction surgery is determined by donor and recipient related factors. The purpose of this article was to identified all studies reporting donor and recipient characteristics, including the age and gender of donors, along with the age, gender, activity level and smoking status of recipients, that affect the biomechanical properties and post-transplantation outcomes of allograft tendons. The systematic study search was based on MEDLINE via PubMed, Embase and the Cochrane Library databases. The reference lists of the included studies were used for hand searching (snowballing). The searching process was performed by two independent investigators, using search MESH term: “tendon”, “allograft”, and “person”. Studies evaluating the influence of donor and recipient biological characteristics on the mechanical property and transplantation outcome of allograft were included. A total of 12 studies were selected for qualitative synthesis, including 6 studies evaluated the influence of donor characteristics, including age and gender, on the mechanical strength of tendon allograft. 6 studies assessed the influence of recipient characteristics, including age, gender, smoking status, and activity level, on the clinical outcome. As a conclusion, tendon allografts from donor younger than 40 years old were expected to have a higher mechanical property. Young patients or patients with a high level of activity were not recommended to receive allograft tendon when autograft is optional. There is no strong evidence supporting that neither donor or recipient gender affects the tendon allograft transplantation outcomes. Smoking history could increase the risk of complications.
- 2 January 2020
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 21 (1) , 17-29
The influence of donor and recipient characteristics on allograft tendons: a systematic review
Tendon allograft has been an important alternative graft option aside from autograft. The outcome of reconstruction surgery is determined by donor and recipient related factors. The purpose of this article was to identified all studies reporting donor and recipient characteristics, including the age and gender of donors, along with the age, gender, activity level and smoking status of recipients, that affect the biomechanical properties and post-transplantation outcomes of allograft tendons. The systematic study search was based on MEDLINE via PubMed, Embase and the Cochrane Library databases. The reference lists of the included studies were used for hand searching (snowballing). The searching process was performed by two independent investigators, using search MESH term: “tendon”, “allograft”, and “person”. Studies evaluating the influence of donor and recipient biological characteristics on the mechanical property and transplantation outcome of allograft were included. A total of 12 studies were selected for qualitative synthesis, including 6 studies evaluated the influence of donor characteristics, including age and gender, on the mechanical strength of tendon allograft. 6 studies assessed the influence of recipient characteristics, including age, gender, smoking status, and activity level, on the clinical outcome. As a conclusion, tendon allografts from donor younger than 40 years old were expected to have a higher mechanical property. Young patients or patients with a high level of activity were not recommended to receive allograft tendon when autograft is optional. There is no strong evidence supporting that neither donor or recipient gender affects the tendon allograft transplantation outcomes. Smoking history could increase the risk of complications.
- Open Access
- 13 December 2018
- Published by Springer Nature in BMC Cancer
- Vol. 18 (1) , 1-15
Prognostic effect of factors involved in revised Tokuhashi score system for patients with spinal metastases: a systematic review and Meta-analysis
Cancer patients’ survival time has obviously improved, with the development of systemic treatment techniques. However, the probability of metastases to the vertebrae has also been increased which makes some adverse effects on patients’ quality of life. The prediction of survival plays a key role in choosing therapeutic modality, and Tokuhashi Score was established as one of the most commonly used predictive systems for spinal metastases. Thus, this study was conducted to identify the prognostic effect of factors involved in revised Tokuhashi Score (RTS). Two investigators independently retrieved relevant literature on platforms of PubMed, Embase and Cochrane Library. We identified eligible studies through title/abstract and full-text perusing. Data was extracted including general information of studies, participants’ characteristics, therapeutic modality, overall survival and prognostic effect of factors. Hazard ratio (HR) for each factor was synthesized if available through fixed- or random-effect models as appropriate. A total of 63 eligible studies with 10,411 participants were identified. Overall, cases with thyroid cancer had the highest survival rate, while the ones with non-small cell lung cancer and hepatocellular carcinoma lived for the shorted survival time. Performance status, bone metastasis, number of involved vertebrae, visceral metastasis, primary tumor and neurological status were regarded as significant predictors in 71.4, 40.0, 18.2, 63.4, 73.1 and 44.7% of the involved studies respectively. Thirty-eight articles were included in meta-analysis, and prognostic effects of five factors (apart from primary tumor) were analyzed. Factors were all proved to be significant except comparisons between KPS (Karnofsky Performance Status) 10–40 VS. 50–70 and single VS. multiple spinal metastases. All factors of RTS were significant on prognosis predicting and should be considered when choosing therapeutic modality for spinal metastases. What’s more, we believe that more accurate prognosis may be obtained after removal of the cut-offs for KPS 10–40 VS. 50–70 and single VS. multiple involved vertebrae.
- 13 December 2018
- Published by Springer Nature in BMC Cancer
- Vol. 18 (1) , 1-15
Open AccessPrognostic effect of factors involved in revised Tokuhashi score system for patients with spinal metastases: a systematic review and Meta-analysis
Cancer patients’ survival time has obviously improved, with the development of systemic treatment techniques. However, the probability of metastases to the vertebrae has also been increased which makes some adverse effects on patients’ quality of life. The prediction of survival plays a key role in choosing therapeutic modality, and Tokuhashi Score was established as one of the most commonly used predictive systems for spinal metastases. Thus, this study was conducted to identify the prognostic effect of factors involved in revised Tokuhashi Score (RTS). Two investigators independently retrieved relevant literature on platforms of PubMed, Embase and Cochrane Library. We identified eligible studies through title/abstract and full-text perusing. Data was extracted including general information of studies, participants’ characteristics, therapeutic modality, overall survival and prognostic effect of factors. Hazard ratio (HR) for each factor was synthesized if available through fixed- or random-effect models as appropriate. A total of 63 eligible studies with 10,411 participants were identified. Overall, cases with thyroid cancer had the highest survival rate, while the ones with non-small cell lung cancer and hepatocellular carcinoma lived for the shorted survival time. Performance status, bone metastasis, number of involved vertebrae, visceral metastasis, primary tumor and neurological status were regarded as significant predictors in 71.4, 40.0, 18.2, 63.4, 73.1 and 44.7% of the involved studies respectively. Thirty-eight articles were included in meta-analysis, and prognostic effects of five factors (apart from primary tumor) were analyzed. Factors were all proved to be significant except comparisons between KPS (Karnofsky Performance Status) 10–40 VS. 50–70 and single VS. multiple spinal metastases. All factors of RTS were significant on prognosis predicting and should be considered when choosing therapeutic modality for spinal metastases. What’s more, we believe that more accurate prognosis may be obtained after removal of the cut-offs for KPS 10–40 VS. 50–70 and single VS. multiple involved vertebrae.